Loading...
HomeMy WebLinkAboutSTAFF REVIEW COMMENTS (2) CITY OF COLLEGE STATION ( DEVELOPMENT SERVICES 1 101 Texas Avenue South, PO Box 9960 COLLEGE STATION College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM March 4, 2003 TO: Thomas E. Gessner, P.E., via fax 680 -8841 FROM: Bridgette George, Assistant Development Manager SUBJECT: WEST POINTE BUILDING CENTER (SP) - Site Plan Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review: One (1) revised site and landscaping plan; Easement Dedication Sheet and required documents. Please note that the Easement Dedication Sheet and the necessary documents are required prior to the issuance of a building permit. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call Jennifer Flanery at 764 -3570. Attachments: Staff review comments Curb Details Easement Dedication Sheet cc: Charles Moreau via fax 260 -7203 Case file #03- 00500055 Horne of Texas A &M University STAFF REVIEW COMMENTS NO. 1 Project: WEST POINTE BUILDING CENTER (SP) — 03- 00500055 PLANNING 1. Please call out the zoning and ownership of the subject property, and the current zoning of all abutting parcels. 2. Be aware that the plans cannot be approved prior to the rezoning of this property to C -1 General Commercial. 3. Please locate adjacent driveway / curb cuts or access easements in relation to the proposed curb cuts along Old Wellborn Road. 4. Please show all existing easements on -site, including the 10 -ft Public Utility Easement on all sides of the property (except the front). You must also show the platted 40 -ft by 40 -ft access easement that is shared with the property to the south. 5. The 20 -ft Public Utility Easement at the front of the property is a platted easement. Please remove "proposed." 6. The southern most drive should be shifted to lie within the platted access easement. The minimum driveway width is 24 ft. and the maximum width is 36 ft. 7. In addition to the floodplain note provided, please call out the FIRM map that shows that this is not within the 100 -year floodplain. 8. Please delineate which portions of the building are retail and which are warehouse. 9. Please dimension the typical parking stall and call out any others that vary. If the stalls are only 18 -ft long you must have room for a 2 -ft overhang. If the overhang is onto a sidewalk then the sidewalk must be 6 -ft wide. 10. Please provide a screening gate for the dumpster enclosure because the opening faces directly to the public right -of -way. You may also angle the enclosure so that the dumpster is not seen from the right -of -way (and the gates would not be needed). 11. Please call out the height of the proposed screening fence for the dumpster. (8 -ft) 12. Please dimension the dumpster pad (min. 12' x 12'). 13.You will need to extend the fire lane around the property in order for the entire building to be covered by the 150 -ft arc from a fire lane or provide turnaround. 14. Please show the location of the Fire Department Connection (within 150 feet of the future fire hydrant). 15.AII public lines and meters must be located within public right -of -way or a P.U.E., including the fire line and fire hydrant. 16. Please locate the transformer and NC units. These will need to be screened from the right -of -way and adjacent properties. 17.The minimum concrete surfacing requirement for a fire lane is 6 inches with #4 bars, 18 inches on center. 18.The curb detail provided is not acceptable. Please see the attached curb details that are acceptable. 19. Shrubs used for screening of parking spaces must be at a minimum 3 feet on center. 20. Please recalculate your landscape requirements. Do not subtract the area of the landscape reserve. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 2 of 3 21.Please contact Isabell Cantu with BTU at 821 -5770 for utilities /site plan coordination. Reviewed by: Jennifer Flanery Date: February 28, 2003 ENGINEERING 1. No further comments at this time. Plat faxed 3/3/03. 2. It is our understanding that this project is requesting a variance to the building /fire code ordinance requiring "fire flow" at a hydrant. Reviewed by: Spencer Thompson Date: March 3, 2003 ELECTRICAL 1. BTU service area. Reviewed by: Ronnie Bolin Date:2 -27 -03 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 3 of 3 EASEMENT DEDICATION SHEET To be filled in and submitted with construction plans and specifications for preliminary review (Not to be used where City is purchasing property) THIS SECTION TO BE COMPLETED BY CITY STAFF PROCESSED BY: DEPT. EXT. REQUESTED BY: DEPT. EXT. ACCOUNT NO. PROJECT NO. (For ordering title work, appraisals, etc.) TYPE OF EASEMENT: Public Utilities (PUE) Temporary Blanket PUE Electric Only (prior to building permit) Water Only SPECIAL INSTRUCTIONS: REVIEW AND APPROVAL REQUIRED /GIVEN BY THE FOLLOWING DEPARTMENTS: Approval Required By: Electric Approval Given By: Electric (please initial) Water /WW (please initial) Water /WW Asst. City Engineer Asst. City Engineer Public Works Public Works METES & BOUNDS DESCRIPTION CHECKED FOR CLOSURE BY: (City Staff - Name /Dept.) THIS SECTION TO BE COMPLETED BY APPLICANT PROPERTY OWNER(S): (Names must be exactly as they appear on the deed) ADDRESS: PHONE NUMBER: ALL LENDERS (Please furnish copies of all lien documents): (Names and Addresses) IF OWNER IS A CORPORATION, PARTNERSHIP, OR JOINT VENTURE (also see #5 below): 1. State of Incorporation /Registration 2. Partners' Names (if applicable) 3. Person Authorized to Sign (Name and Title) LEGAL DEPARTMENT MUST BE PROVIDED WITH THE FOLLOWING: (Please check items that are attached) 1. A copy of a recent (within 90 days) deed or title insurance policy showing the names of the grantors /owners; and 2. For unplatted property, a signed, sealed and dated metes and bounds description and a diagram of the property showing the location of the easement; or 3. For platted property, a copy of the plat showing the lot, block, subdivision, and recording information. 4. For blanket easements, a signed, sealed and dated metes and bounds description and a diagram of the property. 5. Corporate or partnership owners must furnish a copy of a corporate resolution or other proof of authority to sign on behalf of the corporation, partnership, or joint venture. 6. Name, address and phone number of person who is to receive the easement and be responsible for getting it executed: Any land acquisition resulting from Capital Improvement Projects requires a meeting with the Legal Department. bslp: Igroupllegalleasement infolesmtinJosheetrev2- 26- 03.doc Exhibit A. Figure 1 #4 BAR (TYP) ` 6" #4 ® 24" C —C Pl #4 BARS (TYP) w■ImIlloaammallmmi =mow pip/ 18 8 " 2' 1 18" 8 " CURBING OPTIONS ASPHALT PAVEMENT Zoning Ordinance Page 9 - 5 Exhibit A. Figure 2 , f I t 1 #4 ® 24" C -C 1 Fi #4 BARS (TYP) P 1 8 { I U #4 BAR (TYP) 6" 1 ' 2 ' CURBING OPTIONS CONCRETE PAVEMENT Zoning Ordinance Page 9 - 6 • BROADCAST REPORT TIME : 03/04/2003 17:47 NAME : COCS DEVELOPMENT SER FAX : 9797643496 TEL : 9797643570 SER.# : BR0E2J341073 PAGE(S) 06 DATE TIME FAX NO. /NAME DURATION PAGE(S) RESULT COMMENT 03/04 17:44 96808841 01:24 06 OK ECM 03/04 17:46 92607203 01:26 06 OK ECM BUSY: BUSY /NO RESPONSE NG : POOR LINE CONDITION CV : COVERPAGE PC : PC -FAX } CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 COLLEGE STATION College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM March 25, 2003 TO: Thomas E. Gessner, P.E., via fax 680.8841 FROM: Bridgette George, Assistant Development Manager SUBJECT: WEST POINTE BUILDING CENTER (SP) - Site Plan Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review and approval: Development Permit, required documents, and fees; Six (6) complete sets of construction documents for the proposed development with the revised site and landscaping plans attached; Two (2) revised site plans; and One (1) revised landscaping plan. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 764 -3570. Attachments: Staff review comments cc: Charles Moreau, via fax 260.7203 Case file #03- 00500055 Home of Texas A &M University STAFF REVIEW COMMENTS NO. 2 Project: WEST POINTE BUILDING CENTER (SP) - 03- 00500055 PLANNING 1. After a conversation with Mr. Moreau about potential lease spaces, you will need to delineate the tenant lease spaces. Three or more retail uses will make this a shopping center requiring 1 parking space for every 150 square feet. Two or fewer retail uses require a parking determination of 1 space for every 250 square feet. 2. Please show the zoning of this property as C -2 Commercial Industrial on the site plan. Don't label the zoning as proposed because the zoning must be in place for the plans to be approved. 3. Please show the curb along the southern property line. The curb within the access easement must be a knock off curb to connect to the adjacent property at a later date. 4. The minimum driveway width is 24'. 5. Please dimension the distance from the proposed driveway at the northern end of the property to the platted access easement on the adjacent northern property. Reviewed by: JENNIFER FLANERY Date: March 21, 2003 ENGINEERING 1. A reminder. A Drainage Report was received. However, the report is a requirement of the Development Permit. It appears that one has not been applied for, at this time. Reviewed by: Spencer Thompson Date: March 15, 2003 NOTE: Any changes made to the plans, that have riot been requested by the City of College Station, must be explained in your next transmittal letter and 'bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2 of 2 CITY OF COLLEGE STATION `j DEVELOPMENT SERVICES `� 1101 Texas Avenue South, PO Box 9960 COLLEGE STATION College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM April 22, 2003 TO: Thomas E. Gessner, P.E., Via fax 680.8841 FROM: Bridgette George, Assistant Development Manager SUBJECT: WEST POINTE BUILDING CENTER (SP) - Site Plan Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review: $200 processing fee for the next round of three (3) staff reviews; and, Six (6) complete sets of construction documents for the proposed development with the revised site and landscaping plans attached; Two (2) revised site; and One (1) landscaping plan. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 764 -3570. Attachments: Staff review comments cc: Charles Moreau, Via fax 260.7203 Case file #03- 00500055 Home of Texas A &M University STAFF REVIEW COMMENTS NO. 3 Project: WEST POINTE BUILDING CENTER (SP) - 03- 00500055 PLANNING 1. The minimum driveway width is 24 feet. The driveways are currently shown as smaller than the minimum. (repeat comment) 2. Please either show the curb on the southern property line or call out that there is a curb in this location. Reviewed by: Jennifer Prochazka Date: April 21, 2003 ENGINEERING 1. Development Permit comments will be separate. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and 'bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2 of 2