HomeMy WebLinkAboutAPPLICATION R fIa '
FOR OFFICE USE ^ ) N / i � Y
/V
P&Z CASE NO.: ��? 3
COIUGE ^ STAY_ ION
DATE SUBMITTED: 04
FINAL PLAT APPLICATION DP-- / -
(Check one) _ Minor Amending X Final Vacating Replat
($300.00) ($300.00) ($400.00) ($400.00) ($400.00)
The following items must be submitted by an established filing deadline date for P &Z Commission consideration.
MINIMUM SUBMITTAL REQUIREMENTS:
x Filing Fee (see above) NOTE: Multiple S - -ts - $55.00 per additional sheet
X Development Permit Application Fee o $200.00 if applicable).
X Infrastructure Inspection Fee of $600.00 applicable if any public infrastructure is being constructed.).
X Application completed in full.
X Thirteen (13) folded copies of plat. (A signed mylar original must be submitted after staff review.)
X One (1) copy of the approved Preliminary Plat and /or one (1) Master Plan (if applicable). - Already Submitted.
X Paid tax certificates from City of College Station, Brazos County and College Station I.S.D. Attached.
X A copy of the attached checklist with all items checked off or a brief explanation as to why they are not.
x Two (2) copies of public infrastructure plans associated with this plat (if applicable).
X Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of
approval (if applicable). Already Submitted.
NAME OF SUBDIVISION Westfield Addition - Phase 2B
SPECIFIED LOCATION OF PROPOSED SUBDIVISION 5 Blocks, 49 Lots/ Robert Stevenson Survey.
Abstract No. 54 College Station, Brazos County, Texas
APPLICANT /PROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name Rick Jenkins Main Street Homes CS, Ltd.
Street Address 900 Congress Ave. , 1 #L -100 City Austin .
State Texas Zip Code 78701 E -Mail Address rickjenkins@pruowens.com
Phone Number (512) 801 -8832 Fax Number (512) 478 -5678
PROPERTY OWNER'S INFORMATION:
Name Main Street Homes- CS, Ltd.
Street Address 900 Congress Ave.. #L -100 City Austin
State Texas Zip Code 78701 E -Mail Addr ess rickjenkins @pruowens.com
Phone Number (512) 801 -8832 Fax Number (512) 478 -5678
ARCHITECT OR ENGINEER'S INFORMATION:
Name CSC Engineering & Environmental Consultants, Inc./ Riley Engineering Company
Street Address 3407 Tabor Rd/ 7182 Riley Road Cit Bryan
State Texas Zip Code 77808 E -Mail Address csc@txcyber.com
Phone Number (979) 778 -2810 Fax Number (979) 778 -0820
(979) 589 -2457
FNLPAPP.DOC 2/12/02 1 of 3
RECEIVED: 4/17/03 9:3OAM; - >RICK; #921; PAGE 3
04/17/2003 08:41 409 - 778_0820 CSC ENG & ENV PAGE 03
Total Acres Of Subdivision 2.40 Are R -O -W Acreage 11 Total # Of Lots .74 Acre
Number Of Lots By Zoning District 1 / R -
Average Acreage Of Each Residentiall Lot By Zoning District:
I / /
.15 Acre/ R -1 -4__—
/
Floodplain Acreage , None
A Statement Addressing Any Differences Between The Final Plat And Approved Master Development Plan
And /Or Preliminary Plat (If Applicable):
Final Plat has two phases: Phase 2A and Phase 28; Phase 2A already submitted..
Requested Variances To Subdivision Regulations & Reason For Same: None Requested
Requested Oversize Participation: None Reauested.
Total Linear Footage of Parkland Dedication due prior to filing the Final Plat:
Proposed Public: ACREAGE:
Acreage already dedicated.
606 Streets N/A # of acres to be dedicated + $ development fee
598 Sidewalks # of acres in floodplain
0 Sanitary Sewer Lines # of acres in detention
871 Water Lines # of acres in greenways
0 Channels OR
0 Storm Sewers FEE IN LIEU OF LAND:
$ i3d7
0 Bike Lanes / Paths 11 # of Single - Family Dwelling Units X $ .7 = $ 339'9"
(date) Approved by Parks & Recreation Board
NOTE: DIGITAL COPY OF PLAT MUST BE SUBMITTED PRIOR TO FILING.
The applicant has prepared this application and certifies that the facts stated herein and exhibits attached
hereto are true, correct and complete. The undersigned hereby requests approval by the City of College
Station of the above - identified final plat.
V(et 2 j j o� T r ,72- 1 , 1-003
Signet and Title Date
FNIPAPP.DOC 2/12/02 2 of 3
RECEIVED: 4/17/03 9:31AM; - BRICK; #921; PAGE 4
04/17/2003 08:41 409 - 778 -0820 CSC ENG & ENV PAGE 04
SUPPLEMENTAL DEVELOPMENT PERMIT INFORMATION
Application is hereby made for the following development specific site /waterway alterations:
/Jo
ACKNOWLEDQMENT$;
1 . design engineer /owner, hereby acknowledge or affirm that:
The information and conclusions contained In the above plans and supporting documents comply with the current
requirements of the City of College Station, Texas City Code, Chapter 13 and its associated Drainage Policy and Design
Standards. As a condition of approval of this permit application, I agree to construct the improvements proposed in this
application . , cording to these documents and the requirements of Chapter 13 of the College Station City Code.
Pro -rty er(s) Contractor
ill CERTIFI • TIONS: (for proposed alterations within designated flood hazard areas.)
A I m t= . L r lt C* irk T certify that any nonresidential structure on or proposed to be on this site
as part of this application Is designated to prevent dam ge to th structure or its contents as a result of flooding from the
100 year storm. -Ten wal. os 'nc� vutov'eside' 4 Xe c b
q�y� 'atA 0 3
Engineer Date
B. I, M. K'►ck C.eml.;%n lit certify that the finished floor elevation of the lowest floor, including any
basement, of any residential structu proposed as part of this application is at or above the base flood elevation
established in the latest Federal Insurance Administration Flood Hazard Study and maps, as amended.
°)')1 44-11 =ALS
Engineer Date
C. I, M,Fvw,JP■iok C,011.irOi , certify that the alterations or development covered by this permit shall
not diminish the flood- carrying capacity of the waterway adjoining or crossing this. permitted site and that such alterations
or development are consistent with requirements of the City of College Station City Code, Chapter 13 concerning
encroachments of floodways and of floodway fringes.
.14. o4. 1 s f A3
Engineer Date
D. I, Pfd. t J> c1. C'n1.i'1, arc''. , do certify that the proposed alterations do not raise the level of the 100
year flood above elevation established in the latest Federal Insurance Administration Flood Hazard Study.
m. C'.;,, P 044 t_s /as
Engineer Date
Conditions or comments as part of approval: ,
In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure
that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage
facilities. All development shall be in accordance with the plans and specifications submitted to and approved by the City
Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall
apply -
FNLPAPP.DOC 2/12/02 3 of 3
SUBMIT APPLICATION AND THIS
LIST CHECKED OFF WITH 13
FOLDED COPIES OF PLAT FOR REVIEW
COLLEGE STATION
FINAL PLAT MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
(Requirements based on field survey and marked by monuments and markers.)
• 1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger.
• 2. Vicinity map which includes enough of surrounding area to show general location of subject
property in relationship to College Station and its City Limits. No scale required but include north
arrow.
• 3. Title Block with the following information:
Name and address of subdivider, recorded owner, planner, engineer and surveyor.
5i Proposed name of subdivision. (Subdivision name & street names will be approved
through Brazos County 911.) (Replats need to retain original subdivision name.)
® Date of preparation.
Engineer's scale in feet.
It Total area intended to be developed.
4. North Arrow.
L1 5. Subdivision boundary indicated by heavy lines.
L 6. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or
larger.
❑ 7. All applicable certifications based on the type of final plat.
El Ownership and Dedication
of Surveyor and /or Engineer
City Engineer (and City Planner, if a minor plat)
N/A ❑ Planning and Zoning Commission (delete if minor plat)
EN Brazos County Clerk
N/A ❑ Brazos County Commissioners Court Approval (ETJ Plats only)
• 8. Paid tax certificates.
❑N /A 9. If submitting a replat where there are existing improvements, submit a survey of the subject
property showing the improvements to ensure that no encroachments will be created.
❑ N/A 10. If using private septic systems, add a general note on the plat that no private sewage facility may
be installed on any lot in this subdivision without the issuance of a license by the Brazos County
Health Unit under the provisions of the private facility regulations adopted by the Commissioner's
Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code.
CJ 11. Location of the 100 Year Floodplain and floodway, if applicable, according to the most recent
available data.
• 12. Lot corner markers and survey monuments (by symbol) and clearly tied to basic survey data.
FINAL PLAT CHECKLIST 1 of 2
FNLPCK.DOC 02/12/02
. It 13. Matches the approved preliminary plat and /or master development plan.
x' 14. The location and description with accurate dimensions, bearings or deflection angles and radii,
area, center angle, degree of curvature, tangent distance and length of all curves for all of the
following: (Show existing items that are intersecting or contiguous with the boundary of or forming
a boundary with the subdivision, as well as, those within the subdivision).
Existing Proposed
❑ Streets. Continuous or end in a cul -de -sac, stubbed out streets must end into a temp
turn around unless they are shorter than 100 feet.
❑ IR Public and private R.O.W. locations and widths. (AII existing and proposed R.O.W.'s
sufficient to meet Thoroughfare Plan.)
❑ Street offsets and /or intersection angles meet ordinance.
❑ ❑N /A Alleys.
E Easements.
❑ A number or letter to identify each lot or site and each block.
❑ ❑N /A Greenbelt area /park linkages /parkland dedication ( All proposed dedications must be
reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.)
15. Construction documents for all public infrastructure drawn on 24" x 36" sheets and properly sealed
by a Licensed Texas Professional Engineer that include the following:
M Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall
street, alley and /or sidewalk layout of the subdivision. (may be combined with other
utilities).
IJ Sanitary sewer plan and profile showing depth and grades. One sheet must show the
overall sewer layout of the subdivision. (Utilities of sufficient size /depth to meet the
utility master plan and any future growth areas.)
It Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing
depth and grades. One sheet must show the overall water layout of the subdivision.
(Utilities of sufficient size /depth to meet the utility master plan and any future growth
areas.)
Storm drainage system plan with contours, street profile, inlets, storm sewer and
drainage channels, with profiles and sections. Drainage and runoff areas, and runoff
based on 5, 10, 25, 50 and 100 year rain intensity. Detailed drainage structure design,
channel lining design & detention if used. One sheet must show the overall drainage
layout of the subdivision.
Di Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E.
Drainage Report.
tl Erosion Control Plan (must be included in construction plans).
16. All off -site easements necessary for infrastructure construction must be shown on the final plat
with a volume and page listed to indicate where the separate instrument easements were filed.
Separate instrument easements must be filed prior or concurrently with Final Plat.
• 17. Are there impact fees associated with this development? Yes No
Impact fees for R -1, R -2, & R -3 zoned final plats, must be paid prior to filing.
❑ 18. Will any construction occur in TexDOT rights -of -way? Yes No
If yes, TexDOT permit must be submitted along with the construc ion documents.
NOTE:
1. We will be requesting the corrected Final Plat to be submitted in digital form if available prior to
filing the plat at the Courthouse.
2. If the construction area is greater than 5 acres, EPA Notice of Intent (NOI) must be submitted prior
to issuance of a development permit.
FINAL PLAT CHECKLIST 2 of 2
FNLPCK.DOC 02/12/02