HomeMy WebLinkAboutSTAFF REVIEW COMMENTS CITY OF COLLEGE STATION `I DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 COLLEGE STATION Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM November 4, 2003 TO: Alton Ofczarzak, Oakwood Custom Home Grp, Ltd., Via fax 690.2504 FROM: Bridgette George, Assistant Development Manager SUBJECT: BRIDLE GATE ESTATES PH 2 (FP) - Final Plat Staff reviewed the above - mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. If all comments have been addressed and the following information submitted by Monday, November 10, 10:00 a.m., your project will be placed on the next available Planning and Zoning Commission meeting scheduled for, November 20, 2003, 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue. Two (2) copies of the revised final plat; Parkland Dedication in the amount of $15,012 must be submitted prior to the filing of the final plat; One (1) Mylar original of the revised final plat; and One (1) copy of the digital file of the final plat on diskette or e-mail to nmanhart@ci.college- station.tx.us Upon receipt of the required documents for the Planning & Zoning meeting, your project will be considered formally filed with the City of College Station. Please note that if all comments have not been addressed your project will not be scheduled for a Planning & Zoning Commission meeting. Your project may be placed on a future agenda once all the revisions have been made and the appropriate fees paid. If you have any questions or need additional information, please call Spencer Thompson or myself at 764.3570. Attachments: Staff review comments cc: Michael G. Hester, PE, Via fax 693.1075'/ Case file #03- 00500273 Home of Texas A&M University STAFF REVIEW COMMENTS NO. 1 Project: BRIDLE GATE ESTATES PH 2 (FP) - 03- 00500273 ENGINEERING 1. Please provide at least a 5 -ft PUE on lots along Bridal Court due to proximity of proposed utilities in ROW. Reviewed by: Spencer Thompson Date: October 30, 2003 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 2 of 2 CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 COLLEGE STATION College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM November 4, 2003 TO: Alton Ofczarzak, Oakwood Custom Home Grp, Ltd, Via fax 690.2504 V/ FROM: Bridgette George, Assistant Development Manager SUBJECT: BRIDLE GATE ESTATES PH 2 (FP) — Construction Documents Staff reviewed the above - mentioned engineering documents as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review and approval of the plans: Three (3) sets of revised construction documents. If you have any questions or need additional information, please call Spencer Thompson or myself at 764.3570. Attachments: Staff Review Comments Cc: Michael G. Hester, PE, Via fax 693.1075 v Case file no. 03- 00500273 Home of Texas ABM University i ENGINEERING REVIEW COMMENTS No. 1 These comments are in relation to the required construction documents for Bridal Gate Estates Phase 2. 1. Sheet 1: Please note, plans show existing sewer line section. If this line is NOT in this location, elevation, slope, etc, provisions will need to be made to redesign sewer line to meet TCEQ/ City requirements. 2. Sheet 1: include air relief on water line at high point. 3. Sheet 1: due to proximity of water line to ROW, the fire hydrant should be designed with a horizontal 90 -deg ell so that it is not in a private yard. 4. All infrastructure within 5 -ft of roadway is required to have structural fill embedment. Please add detail depicting structural fill areas and structural fill embedment details. If cement - stabilized sand is specified, include detail. 5. Add 2 -in sand cushion to sidewalk detail. 6. Note states "All sewer services shall be 6 -in dia. And made of the same material as the sewer main." Detail on Sheet 3 shows 4 -in service lines. Service lines are required to be SDR -21 or SCH 40. 7. Show stationing of sewer laterals. Reviewed by: Spencer Thompson Date: November 3, 2003 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City of College Station will constitute a completely new review. Page 2 of 2