Loading...
HomeMy WebLinkAboutAPPLICATION tcv � FOR OFFICE USE ONLY I 0 ; �� I ( � P8Z CASE NO.: I _ DATE SUBMITTED: cI - O 3 COLLEGE STATION I 0 � , SITE PLAN APPLICATION MINIMUM SUBMITTAL REQUIREMENTS Yr Site plan application completed in full. 21 $200.00 Application Fee. 21 $200.00 Development Permit Application Fee. I® $600.00 Public Infrastructure Inspection Fee if applicable. (This fee is payable if construction of a public waterline, sewerline, sidewalk, street or drainage facilities is involved.) ► l Ten (10) folded copies of site plan. A copy of the attached site plan checklist with all items checked off or a brief explanation as to why they are not checked off. ligq Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of approval (if applicable). NAME OF PROJECT Chicken Express ADDRESS 800 Earl Rudder Freeway LEGAL DESCRIPTION Lot 2RE, Block 1 Gateway Subdivison APPLICANT (Primary Contact for the Project): Name Veronia Morgan /Mitchell & Morgan, LLP E -Mail v(Wmitchellandmorgan.com Street Address 511 University Drive East, Suite 204 City College Station State TX Zip Code 77840 Phone Number (979) 260 -6963 Fax Number (979) 260 -3564 PROPERTY OWNER'S INFORMATION: Name Clayton W. Rhoades E -Mail claytonrhoades(Whotmail.com Street Address 800 Earl Rudder Freeway City College Station State TX Zip Code 77840 Phone Number (979) 731 -1894 Fax Number (979) 731 -1894 ARCHITECT OR ENGINEER'S INFORMATION: Name , Same as Applicant E -Mail Street Address City State Zip Code Phone Number Fax Number OTHER CONTACTS (Please specify type of contact, i.e. project manager, potential buyer, local contact, etc.) Name Larry Weatherly E -Mail Larry(Wldwandassoc.com Street Address 6813 Franwood Terrance City Fort Worth State TX Zip Code 76112 Phone Number (817) 457 -1954 Fax Number (817) 457 - 1954 Site Plan.DOC 08/01/02 1 of 3 CURRENT ZONING C -1 w/ O -V PRESENT USE OF PROPERTY vacant PROPOSED USE OF PROPERTY restaurant w/ drive -thru VARIANCE(S) REQUESTED AND REASON(S) none # OF PARKING SPACES REQUIRED 23 # OF PARKING SPACES PROVIDED 23 MULTI - FAMILY RESIDENTIAL PARKLAND DEDICATION otal Acreage , # of ■' Iti- Family Dwelling Units Floodplain Acreage 1i-t x $3. • = $ Housi 'g Units # of acres • floodplain ' f A K1-71L # if 1 Bedroom Units # of acres in det- •tion # of ' Bedroom Units # of acres in greenwa # of 3 : -droom Units date dedication approved by 'arks Board # of 4 Bed •om Units COMMERCIAL FOR 2 BEDROO UNITS ONLY Total Acreage .586 acres # Bedrooms = ' 32 sq. ft. Building Square Feet 2325 sf # Bedrooms < 13: sq. ft. Floodplain Acreage _ CW 0(.10- NOTE: Parkland Dedication fee is due prior to the issuance of a Building Permit. The plicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto true and correct. ! ).;^‘ i,4k_ f ' , l i" ) :), ' \ +, "----------- Signature of Owm 'r, Ag ` o�\Applicant Date 1 I SITE PLAN CHECKLIST 2 of 3 Site Plan.DOC 08/01/02 SUBMIT APPLICATION AND THIS ~ CA LIST CHECKED OFF WITH 10 FOLDED COPIES OF SITE PLAN FOR REVIEW COLLEGE STATION SITE PLAN MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: NO 1. Sheet size - 24" x 36" (minimum). NO 2. ,/key map (not necessarily to scale). \LI 3. Ti block to include: \ il ame, address, location, and legal description `F] me, address, and telephone number of applicant ' J me, address, and telephone number of developer /owner (if differs from applicant) til ame, address, and telephone number of architect/engineer (if differs from applicant) b gate of submittal 4Jfotal site area N ri.1 4. %rth arrow. I \ii 5. ,,Scale should be largest standard engineering scale possible on sheet. r o b 6. ownership and current zoning of parcel and all abutting parcels. N W 7. Existing locations of the following on or adjacent to the subject site: NUJ \ Streets and sidewalks (R.O.W.). \ \O Driveways (opposite and adjacent per Section 7.3 of the Unified Development Ordinance). iI4 Buildings. DIA Water courses. '911 \ Show all easements clearly designating as existing and type (utility, access, etc.). "QI \ \\ 100 yr. floodplain and floodway (if applicable) on or adjacent to the proposed project site, note if ( there is none on the site. \ID \ Utilities (noting size and designate as existing) within or adjacent to the proposed site, including building transformer locations, above ground and underground service connections to buildings, and drainage inlets. \ E] Meter locations. \i Topography (2' max or spot elevations) and other pertinent drainage information. (If plan has \too much information, show drainage on separate sheet.) 8. Proposed location, type and dimensions of the following.: SA , 'Phasi ch phase must be able to stand alone to meet ordinance requirements. y gross square footage of all buildings and structures and the proposed use of each. If different uses are to be located in a single building, show the location and size of the uses within the building. Building separation is a minimum of 15 feet w/o additional fire protection. X IZI • ,,Setcks. Show building setbacks as outlined in the Unified Development Ordinance, Article 5. \O Street parking areas with parking spaces drawn, tabulated, and dimensioned. Minimum parking space is 9' x 20', or on a perimeter row 9' x 18' with a 2' overhang. Designate number ,ofp�arking spaces required by ordinance and provided by proposal. '- Handicap parking spaces. SITE PLAN CHECKLIST 1 of 3 SITECK 06/17/03 NI /arking Islands. Raised landscape islands, (6" raised curb) a minimum of 180 sq. ft. are required at both ends of every parking row (greenspace area contiguous to the end island maybe applied toward the required 180 sq. ft.). Additibnally, 180 sq. ft. of landscaping for every 15 interior parking spaces must be provided. All required islands must be landscaped or set vyith decorative pavers, or stamped dyed concrete or other decorative materials as approved. "] Vbrives. Minimum drive aisle width. Ro Curb cuts. For each proposed curb cut (including driveways, streets, alleys, etc.) locate existing curb cuts on the same opposite side of the street to determine separation distances between existing and proposed curb cuts. Indicate driveway throat length as measured in the Unified Development Ordinance, Section 7.3 Access Management and Circulation. \ — i�'q Security gates (show swing path and design specs with colors). `4 ,— Sidewalks (both public and private). Sidewalks are required at time of development if property —per T s has frontage on a street shown on the Sidewalk Master Plan or if the review staff determines a ' w rocpzirre1 the necessity. � �/A Medians. Show any and all traffic medians to be constructed on site. (/kfifteen foot parking setback from R.O.W. to curb of parking lot is required. Pavement may encroach into this 15' setback by up to 7 contiguous parking spaces. A double parking island (360 square feet) must be provided between each group of seven spaces. In no case may the pavement be Tess than 6' from the property line. El■ rnon open spaces sites WA o ding docks 63 /A yntention ponds w/A ardrai I Q ,p, t vaining walls IZ,bA required and other types of fences (a 6' privacy fence is required between industrial /commercial and residential developments as well as between multi - family and single fajnily developments). / QP -1\ 61 oi bites for solid waste containers with screening. Locations of dumpsters are accessible but not e visible from streets or residential areas. Gates are discouraged and visual screening 4tact^Dci (1/46;)3101 IAcf refired. (Minimum 12 x 12 pad required.) iC1 Show all easements clearly designating as proposed and type (utility, access, etc.). If dedicated b - - pavate instrument list by volume and page. NO o f tilities (noting size and designate as proposed) within or adjacent to the proposed site, Including building transformer locations, above ground and underground service connections to I mo ' 1. • tidings. arik Meter locations (must be located in public R.O.W. or public utility easement.). Vi roposed grading (1' max for proposed or spot elevations) and other pertinent drainage information. (If plan has too much information, show drainage on separate sheet.) 1i] —Show proposed and existing fire hydrants. Fire hydrants must be located on the same side of a major street as a project, and shall be in a location approved by the City Engineer. Any structure in any zoning district other than R -1, R -1A, or R -2 must be within 300 feet of a fire drant as measured along a public street, highway or designated fire lane. I /q Show fire department connections. FDC's should be within 150' of the fire hydrant. In no case shall they be any further than 300' apart, and they shall be accessible from the parking lot without being blocked by parked cars or a structure. ' J mow fire lanes. Fire lanes a minimum of 20 feet in width with a minimum height clearance of 14 feet must be established if any portion of the proposed structure is more than 150 feet from the curb line or pavement edge of a public street or highway. NOTE: Fire hydrants must be operable and accepted by the City, and drives must have an all weather surface as defined in the Zoning Ordinance Section 9 before a building permit can be issued. No 9. -Will building be sprinkled? Yes ❑ No NU If the decision to sprinkle is made after the site plan has been approved, then the plan must be resubmitted. SITE PLAN CHECKLIST 2of3 SITECK 06/17/03 /p 10. elstops may be required when cars overhang onto property not owned by the applicant or where there may be conflict with handicap accessible routes or above ground utilities, signs or other conflicts. 1 11. t�how curb and pavement detail. A 6" raised curb is required around all edges of all parts of all paved areas without exception. (To include island, planting areas, access ways, dumpster locations, utility pads, etc.) Curb details may be found in the Section 7.2 of the Unified Development Ordinance and alternatives to those standards must be approved by the City Engineer. No exception will be made for areas designated as "reserved for future parking ". 12. Landscape plans as required in Section 7.5 of the Unified Development Ordinance. The landscaping plan can be shown on a separate sheet if too much information is on the original site plan. If requesting protected tree points, then those trees need to be shown appropriately barricaded on the landscape plan. Attempt to reduce or eliminate plantings in easements. Include information on the plans such as: ed point calculations dditional streetscape points required. Streetscape compliance is required on all p3ticulations for # of street trees required and proposed (proposed street tree points will accrue toward total landscaping points.) \ `6tj i p,cdposed new plantings with points earned dosed locations of new plantings ci 4 screening of parking Tots screening of dumpsters, detention ponds, transformers, A/C units, loading docks, propane tanks, utility demarcation point on buildings, or other areas potentially visually offensive. cad ,existing landscaping to remain VI/q , show existing trees to be barricaded and barricade plan. Protected points will only be awarded V[f barricades are up before the first development permit is issued. suffer as required in Section 7.6 of the Unified Development Ordinance. 13. , irrigation system plan. (or provide note on how irrigation system requirement will be met prior to issuance of C.O.) All plans must include irrigation systems for landscaping. Irrigation meters are separate from the regular water systems for buildings and will be sized by city according to irrigation demand submitted by applicant and must include backflow prevention protection. \ \ti7 14. Is there any landscaping in TxDOT R.O.W.? Yes ❑ No 'E] If yes, then TxDOT permit must be submitted. \ 15. Will there be any utilities in TxDOT R.O.W.? Yes CI No `O If yes, then TxDOT permit must be submitted. \ �tc7 16. Will there be access from a TxDOT R.O.W.? Yes ❑ No L7 If yes, then TxDOT permit must be submitted. .VP 17. The total number of multi - family buildings and units to be constructed on the proposed project site. WA 18. The density of dwelling units per acre of the proposed project. 19. Provide a water and sanitary sewer legend to include water demands (minimum, maximum and average demands in gallons per minute) and sewer loadings (maximum demands in gallons per day). �CII 20. Are there impact fees associated with this development? Yes ❑ No `E] NOTE: Signs are to be permitted separately. SITE PLAN CHECKLIST 3 of 3 SITECK 06/17/03