HomeMy WebLinkAboutApplication - ' ate
<0
FOR OFFICE USE ONLY
CASE NO.:
1111 DATE SUBMITTED: li - 1- 4'
COILI (F STATION N
e t z DESIGN DISTRICT SITE PLAN REVIEW APPLICATION
Design Review Board
(Check one) I I NG -1 n NG -2 1 I NG -3 ig, WPC n OV
Staff Review Only
MINIMUM SUBMITTAL REQUIREMENTS
—" Special District site plan application completed in full.
Y $200.00 Application Fee.
V $200.00 Special District Review Fee (not required for OV district)
$200.00 Development Permit Application Fee.
$600.00 Public Infrastructure Inspection Fee if applicable. (This fee is payable if construction of a public
/ waterline, sewerline, sidewalk, street or drainage facilities is involved.)
r/ Ten (10) folded copies of site plan, landscape plan, and dimensioned building elevations (including
signage)
V Color and material samples.
�/ A copy of the site plan checklist with all items checked off or a brief explanation as to why they are not
checked off.
Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of
approval (if applicable).
Date of Required Preapplication Conference: fig/ i I - 1 C - C
NAME OF PROJECT 02t,NA Oftl L-- Po.-4 W Att, - '[ _c A 1 -r C�
ADDRESS SW /4Al2, Cove *et G S THTiC►c-! 7 8 4
■
LEGAL DESCRIPTION
.APPLICANT /PROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name SKYL..A - 2_ u —) ai is (y imA at__( Ma
Street Address j'2-O 4 Vf Y D-v. City C o1-1- 7 � aT rrjJ
State T. Zip Code -7 78 4 40 E -Mail Address �,
Phone Number q n - /.0 p /8 Fax Number - / �''
PROPERTY OWNER'S INFORMATION: -1
Name _ F :)17.--p IEIS:rA V12A0.-J1 T -000
Street Address / 57 OA-A/ 0Y RLA j 1,20 lj. City 0STi f-4
State 1 Zip Code 7g '13 E -Mail Address
Phone Number 5 2.10 ' 04 1 2ft Fax Number - 5 12. " 2.6 2, -- 11 jt2.
ARCHITECT OR ENGINEER'S INFORMATION: /�,,, , I , )
Name _ l/C 4r-� <Livt Il'1� t i Ck Cacb
j Street Address (dp (71..A r ✓/u 4 N'.E • D 7 City /7A e-64-.5,
r ` State y zot Zip Code /�
��� /p E -Mail Address /V� ("- 4 q� �// cTaik€ , Cd M.
Phone Number /�� 3(v/ 1 ° J�/ Fax Number _ ?/L/ $b / - / /e4/
6/13/03 Page 1 of 6
OTHER CONTACTS jPlease specify type of contact, i.e. project manager, potential buyer, local contact, etc.)
Name - - - /A' -- - — - - -- -- - - - - - - - -- - - -. - .
Street Address - -- — -- — -- - — City - -- - - --
State -- Zip Code E -Mail Address -
Phone Number - - -_ Fax Number
PRESENT USE OF PROPERTY 02Dx/ er — eq z1 /L ZaESTA- Vz - v/7-,
PROPOSED USE OF PROPERTY - _ ,rz0 /e, V C/L,g -. /A/ e,,,4, . — - -_
VARIANCE(S) REQUESTED AND REASON(S) _ -- -- _ -_ —�
# OF PARKIN; SPACES REQUIRED aii # OF PARKING SPACES PROVIDED /Z
MULTI- FAMILY RESIDENTIAL PARKLAND DEDICATION l
Total Acreage # of Multi - Family Dwelling Units
Floodplain Acreage - X $452 = $
Housing Units _ - # of acres in floodplain
# of 1 Bedroom Units # of acres in detention
# of 2 Bedroom Units # of acres in greenways
# of 3 Bedroom Units date dedication approved by Parks Board
I _ # cf 4 Bedroom Units COMMERCIAL
FOR 2 BEDROOM UNITS ONLY Total Acreage _ / $
# Bedrooms = 132 sq. ft. Building Square Feet / j 1 0 7 .
_ # Bedrooms < 132 sq. ft. Floodplain Acreage 4/A
NOTE: Parkland Dedication fee is due prior to the issuance of a Building Permit.
The a plicanl has prepared this application and certifies that the facts stated herein and exhibits attached
heret 11 , 7 true and correct.
171i1
Sign RI i i e gent or App!Icant Date - -- - -- -- - -
6/13/03
Page 2 of 6
, op,
1
II
,,, - iv-i
COILEGE STATION
1
SUBMIT APPLICATION AND THIS LIST CHECKED OFF WITH 10 FOLDED COPIES OF SITE PLAN FOR REVIEW
SITE PLAN MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
)4 � 1. Sheet size - 24" x 36" (minimum).
A 2. A key map (not necessarily to scale). r (Pt l/tl" it 4
1. 3. Title block to include:
A Name, address, location, and legal description
' Name, address, and telephone number of applicant
cat Name, address, and telephone number of developer /owner (if differs from applicant)
Al Name, address, and telephone number of architect/engineer (if differs from applicant)
Kf Date of submittal
fit Total site area 1
pg / 4. North arrow.
W 5. Scale should be largest standard engineering scale possible on sheet.
Cil 6. Ownership and current zoning of parcel and all abutting parcels.
7. Existing locations of the following on or adjacent to the subject site:
ai Streets and sidewalks (R.O.W.).
4 Driveways (opposite and adjacent per Section 7.3 of the Unified Development Ordinance).
ji Buildings.
Z Water courses.
0 Show all easements clearly designating as existing and type (utility, access, etc.).
f4 100 yr. floodplain and floodway (if applicable) on or adjacent to the proposed project site, note if
there is none on the site.
j../ IA JIi Utilities (noting size and designate as existing) within or adjacent to the proposed site, including
0 .( v,�'' 41 Q 2 building transformer locations, above ground and underground service connections to buildings,
r 1 C2t ' and drainage inlets.
u t . ?
Ar Ii1 Meter locations.
`Q Topography (2' max or spot elevations) and other pertinent drainage information. (If plan has too
much information, show drainage on separate sheet.)
A4 8. Proposed location, type and dimensions of the following.:
ltd vhasing. Each phase must be able to stand alone to meet ordinance requirements.
A/ /pt IU i The gross square footage of all buildings and structures and the proposed use of each. If
different uses are to be located in a single building, show the location and size of the uses within
the building. Building separation is a minimum of 15 feet w/o additional fire protection.
CW' Setbacks. Show building setbacks as outlined in the Unified Development Ordinance,
Article 5.
NilA [4 Off - Street parking areas with parking spaces drawn, tabulated, and dimensioned. Minimum
parking space is 9' x 20', or on a perimeter row 9' x 18' with a 2' overhang. Designate number of
parking spaces required by ordinance and provided by proposal.
6/13/03
Page 4 of 6
• X Handicap parking spaces.
M Parking Islands. Raised landscape islands, (6" raised curb) a minimum of 180 sq. ft. are required
at both ends of every parking row (greenspace area contiguous to the end island maybe applied
toward the required 180 sq. ft.). Additionally, 180 sq. ft. of landscaping for every 15 interior
parking spaces must be provided. All required islands must be landscaped or set with decorative
pavers, or stamped dyed concrete or other decorative materials as approved.
Z. „'brives. Minimum drive aisle width.
,Curb cuts. For each proposed curb cut (including driveways, streets, alleys, etc.) locate existing
curb cuts on the same opposite side of the street to determine separation distances between
existing and proposed curb cuts. Indicate driveway throat length as measured in the Unified
Development Ordinance, Section 7.3 Access Management and Circulation.
IUft -7 c'Security gates (show swing path and design specs with colors).
14 Sidewalks (both public and private). Sidewalks are required at time of development if property has
frontage on a street shown on the Sidewalk Master Plan or if the review staff determines the
necessity.
lil. ' Medians. Show any and all traffic medians to be constructed on site.
gl A fifteen foot parking setback from R.O.W. to curb of parking lot is required. Pavement may
encroach into this 15' setback by up to 7 contiguous parking spaces. A double parking island
(360 square feet) must be provided between each group of seven spaces. In no case may the
pavement be less than 6' from the property line.
4 4 al Oommon open spaces sites
til c- Loading docks
cit Detention ponds
ie ✓Guardrails
p. ` Re ining walls
el ites for solid waste containers with screening. Locations of dumpsters are accessible but not
visible from streets or residential areas. Gates are discouraged and visual screening is required.
(Minimum 12 x 12 pad required.)
G i / i 6 S Ce Show all easements clearly designating as proposed and type (utility, access, etc.). If dedicated
��� by separate instrument list by volume and page. rio
Util (noting size and designate as proposed) within or adjacent to the proposed site, including
building transformer locations, above ground and underground service connections to buildings. 1
4 Meter locations (must be located in public R.O.W. or public utility easement.).
o Proposed grading (1' max for proposed or spot elevations) and other pertinent drainage
9 Uad t l L information. (If plan has too much information, show drainage on separate sheet.)
NI4 Ik) pr oposed and existing fir nts. Fire hydrants must be located on the same side of a
major street as a project, and shall be in a location approved by the City Engineer. Any structure
f
WA, in any zoning district other than R -1, R -1A, or R -2 must be within 300 feet of a fire hydrant as
measured along a public street, highway or designated fire lane. 1
fif 4 A Show fire department connections. FDC's should be within 150' of the fire hydrant. In no case
shall they be any further than 300' apart, and they shall be accessible from the parking lot without
being blocked by parked cars or a structure.
W A 01 Show fire lanes. Fire lanes a minimum of 20 feet in width with a minimum height clearance of 14
feet must be established if any portion of the proposed structure is more than 150 feet from the
curb line or pavement edge of a public street or highway.
NOTE: Fire hydrants must be operable and accepted by the City, and drives must have an all weather
HA GO as defined in the Zoning Ordinance Section 9 before a building permit can be issued.
® 9. Will building be sprinkled? Yes ❑ No ❑
If the decision to sprinkle is made after the site plan has been approved, then the plan must be
resubmitted.
10. Wheelstops may be required when cars overhang onto property not owned by the applicant or
where there may be conflict with handicap accessible routes or above ground utilities, signs or
other conflicts.
6/13/03
Page 5 of 6
0 '11. Show curb and pavement detail. A 6" raised curb is required around all edges of all parts of all
paved areas without exception. (To include island, planting areas, access ways, dumpster
hI /LY locations, utility pads, etc.) No exception will be made for areas designated as `reserved for
future parking ".
tilA 12. Landscape plans as required in Section 7.5 of the Unified Development Ordinance. The
landscaping plan can be shown on a separate sheet if too much information is on the original site
plan. If requesting protected tree points, then those trees need to be shown appropriately
barricaded on the landscape plan. Attempt to reduce or eliminate plantings in easements. Include
information on the plans such as:
N I Ar
required point calculations
1 C4 additional streetscape points required. Streetscape compliance is required on all streets.
calculations for # of street trees required and proposed (proposed street tree points will accrue
toward total landscaping points.)
proposed new plantings with points eamed
proposed locations of new plantings
screening of parking lots, 50 % of all shrubs used for screening shall be evergreen.
screening of dumpsters, concrete retaining walls, off street loading areas, utility connection points,
or other areas potentially visually offensive.
existing landscaping to remain
show existing trees to be barricaded and barricade plan. Protected points will only be awarded
if barricades are up before the first development permit is issued.
Buffer as required in Section 7.6 of the Unified Development Ordinance.
14 /A J 13. Show irrigation system plan. (or provide note on how irrigation system requirement will be met
prior to issuance of C.O.) All plans must include irrigation systems for landscaping. Irrigation
A .0JS Y. meters are separate from the regular water systems for buildings and will be sized by city
according to irrigation demand submitted by applicant and must include backflow prevention
(X)--0-9k protection.
4 4 4 14. Is there any landscaping in TxDOT R.O.W.? Yes ❑ No ❑
If yes, then TxDOT permit must be submitted.
JAI 15. Will there be any utilities in TxDOT R.O.W.? Yes ❑ No ❑
If yes, then TxDOT permit must be submitted.
16. Will there be access from a TxDOT R.O.W.? Yes ❑ No ❑
If yes, then TxDOT permit must be submitted.
17. The total number of multi - family buildings and units to be constructed on the proposed project
site.
18. The density of dwelling units per acre of the proposed project.
19. Provide a water and sanitary sewer legend to include water demands (minimum, maximum and
average demands in gallons per minute) and sewer loadings (maximum demands in gallons per
day).
20. Are there impact fees associated with this development? Yes ❑ No eel
NOTE: Signs are to be permitted separately.
6/13/03
Page 6 of 6