HomeMy WebLinkAboutWastewater Letter November 11, 2011 HAGOOD
`NSINInuNS AUOCIATU
City of College Station
1 101 Texas Avenue
College Station, Texas 77842
Re: Wastewater Letter
Taco Bell (SP) — 1 1- 005001 43
To Whom It May Concern:
The Taco Bell site is located on Lot 18, Block 3 of the Tower Point Subdivision Phase 8A. This project is
proposing to construct 2,949 SF building with associated utilities and parking. The service lateral for
project is proposed to connect to the existing 6" wastewater line stubout on the northeast area of the
project site. The existing 6" wastewater stub -out connects to a 10" wastewater main which was
constructed with the Tower Point Infrastructure Development, Private Drive G & H.
The maximum wastewater flow for Taco Bell is 70 gpm based on fixture unit count. The 6" wastewater
service pipe has a slope of 5.50% which is less than the maximum slope of 12.35% per TCEQ Chapter
217 requirement. Therefore, the existing sanitary sewer system constructed with the Tower Point
Infrastructure Development, Private Drive G & H, has adequate capacity to handle the new sanitary
sewer flows for the Taco Bell development.
I hope that you find this information adequate. Should you need anything further, please contact me at
your earliest convenience at (512) 244 -1546.
Sincerely,
Hagood Engineering Associates �'�" pF '� *
rickson B. Men.gza P.E. I ' •'• *
Manager ERICKSON B. MENDOZA�
: ) / A 98086
eS �ONAL E�
Alkvik\vbr
It
One Chisholm Trail, Suite 5200 • Round Rock, Texas 78681 • P: 512.244.1546 • F: 512.244.1010 • www.hea.eng.pro
Registration No. F -12709
11 IC13
Pi IS''
cC 60