HomeMy WebLinkAboutStaff Comments STAFF REVIEW COMMENTS NO. 1 Project: Lakeridge Townhomes Ph 1 c (Sp) — 10- 00500259 PLANNING 1. Please indicate how the interior island requirement is being met (180 s.f. for every 15 interior parking spaces). 2. The rear fences of the units in building 5 seem to interfere with the minimum 4 -foot landscaped area (or 6 -foot sidewalk) required for 18 -foot spaces. If the "x" line is not indicating fencing, please disregard comment. 3. Please note the type / location / height of the dumpster screening. 4. Please note that the proposed dumpster location is temporary 5. Please note that any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that the City has not be made of aware of will constitute a completely new review. Reviewed by: Jennifer Prochazka Date: November 30, 2010 LANDSCAPING /STREETSCAPING /BUFFER 1. The minimum shrub size to receive landscape points is 5 gallons. 2. A minimum of 1,116 landscape points need to be earned by canopy trees. Reviewed by: Jennifer Prochazka Date: November 30, 2010 MISCELLANEOUS 1. Irrigation system must be protected by either a Pressure Vacuum Breaker, a Reduced Pressure Principle Back Flow Device, or a Double -Check Back Flow Device, and installed as per City Ordinance 2394. 2. All BackFlow devices must be installed and tested upon installation as per City Ordinance 2394. ENGINEERING COMMENTS NO. 1 1. Please provide a cost estimate, letter of acknowledgement and NOI. 2. Please verify that the previously submitted water, sanitary sewer and drainage reports are still applicable. 3. FYI... PUE dedications will be required prior to issuance of the Letter of Completion or Certificate of Occupancy. 4. Sh.2 — Can all the water meters be clustered in a meter bank? This would allow for less PUE and fewer private lines encroaching in the easements. 5. Sh.3 — Please provide additional silt fencing downstream of proposed water and storm sewer. 6. Sh.6 — Delete text for 30" storm shown at approximate Sta.11 +75. 7. Sh.6 — Please route waterline over the storm sewer as shown on Sh.9. 8. Sh.6 /9 — The flowlines and finished grades needs to match on both sheets. r 9. Sh.7 — The waterline needs to be no deeper than 5 -ft. Please adjust where possible. 10. Sh.9 — Why is the bottom of JB6 shown so deep? 11. Please include all applicable City Standard Details. Reviewed by: Erika Bridges Date: 12/6/10 SANITATION 1. No Comments. Reviewed by: Wally Urrutia Date: December 6, 2010 FIRE COMMENTS 1. No issues. Reviewed by: Eric Dotson Date: December 6, 2010 TxDOT COMMENTS 1. No Comment (no state - system access, no anticipated impact) Reviewed by: Chad Bohne Date: November 22, 2010 ELECTRICAL COMMENTS REQUIRING IMMEDIATE ATTENTION 1. All easements on site are existing. Electric facilities will be designed within existing easements. 2. Developer may be responsible for locating easements on site to insure that electrical infrastructure is installed within easement boundaries. GENERAL ELECTRICAL COMMENTS 1. Developer installs conduit per CSU specs and design. 2. CSU will provide drawings for electrical installation. 3. Developer will intercept existing conduit at designated transformers or other existing devices and extend as required. 4. If conduit does not exist at designated transformer or other existing devices, developer will furnish and install conduit as shown on CSU electrical layout. 5. Developer pours electric device pads or footings (i.e. transformers, pull boxes etc) per CSU specs and design. 6. Developer installs pull boxes per CSU specs and design (pull boxes provided by CSU). 7. Final site plan must show all proposed electrical facilities necessary to provide electrical service, i.e. transformer(s), pull box(es), switchgear(s), meter location and conduit routing as designed by CSU. 8. To discuss any of the above electrical comments please contact Sam Weido at 979.764.6314. Reviewed by: Sam Weido Date: 12 -1 -10