HomeMy WebLinkAboutLetter Ackowledging City Standards Schultz Engineering, LLC Office: 979.764.3900 Fax: 979.764.3910 March 18, 2011 Alan Gibbs, P.E. City Engineer Development Services City of College Station College Station, Texas RE: Letter Acknowledging City Standards — Breezy Heights Addition, Block 4 Lot 8R Dear Mr. Gibbs: The purpose of this letter is to acknowledge that the construction plans for the sanitary sewer and sidewalk for the above - referenced project, to the best of my knowledge, do not deviate from the B /CS Design Guideline Manual except for the existing and proposed sanitary sewer line does have the 2' minimum cover and is not located 5.5' from the edge of the easement. An exception to these requirements is requested due to this unique situation that the existing line does not meet the guidelines, therefore, the proposed 26' extension of the sewer line cannot meet the guidelines. Due to the lack of sufficient cover, the proposed sewer line extension will be constructed of ductile iron pipe instead of PVC and will be backfilled with cement stabilized sand. I also acknowledge that, to the best of my knowledge, the details provided in the construction plans are in accordance with the B /CS Standard Details. Sincerely, /is ffi J = j W . JOSEPH P. SCHULTZ J seph P. Schultz, P.E. \ 65889 Civil Engineer �� F -12327 SCHULTZ ENGINEERING, LLC. P.O. Box 11995 • College Station, Texas 77842 schultzengineeringllc.com