HomeMy WebLinkAboutResponse to staff commentsErika Bridges - Fwd: FW: McDonald's Comments From: Erika Bridges To: Hovde, Lauren Date: 7/29/2011 3:35 PM Subject: Fwd: FW: McDonald's Comments Attachments: REVISED C1.2.pdf; C- 5.pdf; REVISED C1.1.pdf »> "George Torres" <gtorres @kcunited.com> 7/28/2011 4:22 PM »> Erika, Attach is the revised Site plans and detail sheet. Relocated the FDC shown on plans. Please let me know if this will work or you suggest a better location for FDC. Thanks, George Torres K. Chen Engineering 6161 Savoy From: Lauren Hovde [mailto:Lhovde @cstx.gov] Sent: Thursday, July 28, 2011 1:50 PM To: George Torres Subject: Fwd: McDonald's Comments George, Page 1 of 2 Below are the remaining engineering comments. Lauren Lauren Amelia Hovde '06 file: / /C: \Documents and Settings \ebridges \Local Settings \Temp \XPgrpwise \4E32D347City of C81946 El Staff Planner Planning & Development Services Department 979 -764 -3570 »> Erika Bridges 7/28/2011 11:34 AM »> Lauren, Here re my remaining comments for McDonald's: . (Repeat) C -1 — Provide a note with minimum, average, and maximum water and sanitary sewer emands. Why is the average water demand less than the minimum? How is the maximum d omestic demand 1500gpm? ( Repeat) C -1 — Signs, light fixtures, and other private infrastructure are not permitted within PUEs. Please remove. FYI...The McDonald's monument sign will not be permitted within a PUE with future sign permit application. ,(Repeat) C -2 — Private grate inlets need to be located outside of PUE's and privately maintained. The storm grate inlets need to be shown on Sheets C -1 and C -2 as well. (Repeat) C -1.2 — The FDC needs to be relocated so that it is not blocked by parking. If a remote FDC is roposed, it needs to be a separate line originating in the building and terminating with the FDC. It should be located along the fire line and not blocked by parking. (Repeat) C -5 — Please remove the Roll -Up Curb and Gutter Detail. The roll -up curb does not meet the City's Site Design Standards. Please revise. (Repeat) Please provide a Letter of Acknowledgment and sealed Engineer's Cost Estimate for the proposed fire line. A Letter of Acknowledgment was not included in the submittal. A standard form for this letter can be found at www.cstx.gov. Thanks, Erika Erika Bridges, EIT, CFM Graduate Civil Engineer Department of Public Works 1101 Texas Ave. College Station, TX 77842 Phone: 979.764.3570 Fax: 979.764.3496 ebridges(a,cstx.gov * * * * * * * * * * * * * * * * * * ** City of College Station Home of Texas A &M University Page 2 of 2 file: / /C: \Documents and Settings \ebridges \Local Settings \Temp \XPgrpwise \4E32D347City of amp Bi