Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPLICATION
FOR OFFICE USE ONLY P&Z CASE NO.: DATE SUBMITTED: - ' 01 ( COLLEGE STATION FINAL PLAT APPLICATION (Check one) ❑ Minor ❑ Amending ❑ Final ❑ Vacating ® Replat ($300.00) ($300.00) ($400.00) ($400.00) ($600.00)* *Includes public hearing fee The following items must be submitted by an established filing deadline date for P&Z Commission consideration. MINIMUM SUBMITTAL REQUIREMENTS: Ai Filing Fee (see above) NOTE: Multiple Sheets - $55.00 per additional sheet n/a Variance Request to Subdivision Regulations - $100 (if applicable) Al Development Permit Application Fee of $200.00 (if applicable). n/a Infrastructure Inspection Fee of $600.00 (applicable if any public infrastructure is being constructed) Al Application completed in full. n/a Copy of original deed restrictions /covenants for replats (if applicable). �l Thirteen (13) folded copies of plat. (A signed mylar original must be submitted after staff review.) n/a One (1) copy of the approved Preliminary Plat and /or one (1) Master Plan (if applicable). Al Paid tax certificates from City of College Station, Brazos County and College Station I.S.D. Al A copy of the attached checklist with all items checked off or a brief explanation as to why they are not. n/a Two (2) copies of public infrastructure plans associated with this plat (if applicable). n/a Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of approval (if applicable). Date of Preapplication Conference: December 15, 2003 NAME OF SUBDIVISION Herman F. Krenek, Phase II SPECIFIED LOCATION OF PROPOSED SUBDIVISION (Lot & Block) Lot 5 (2.937 ac. Vol. 930, Pq. 653) APPLICANT /PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name Steve E. Duncan, P.E. Street Address 7020 Coyote Run City Bryan State Texas Zip Code 77808 E -Mail Address sed Phone Number (979) 731 -8000 Fax Number (979) 731 -1500 PROPERTY OWNER'S INFORMATION: Name Charles R. & Lucy H. Farrar Street Address P.O. Box 9 City Monument State Texas Zip Code 80132 E -Mail Address Phone Number (719) 488 -0986 Fax Number (719) 481 -2153 ARCHITECT OR ENGINEER'S INFORMATION: Name Steve E. Duncan Street Address 7020 Coyote Run City Bryan State Texas Zip Code 77808 E -Mail Address sedCcpkengineering.com Phone Number (979) 731 -8000 Fax Number (979) 731 -1500 6/13/03 1 of 1 Is there a temporary blanket easement on this property? If so, please provide the Volume 737 and Page # 778 Acreage — Total Property 2.97 Total # Of Lots 2 R -O -W Acreage 0 Existing Use: vacant Proposed Use: hotel Number Of Lots By Zoning District C -1 /2 / / Average Acreage Of Each Residential Lot By Zoning District: C -1 /1.469 / / / Floodplain Acreage 0 A statement addressing any differences between the Final Plat and approved Master Plan and /or Preliminary Plat (if applicable): Property is subdivided into two (2) 1.47 acre lots and a utility easement and a drainage and access easement are added to the front tot 5A Requested Variances To Subdivision Regulations & Reason For Same: n/a Requested Oversize Participation: Total Linear Footage of Parkland Dedication due prior to filing the Final Plat: Proposed Public: ACREAGE: n/a 0 Streets 0 Sidewalks # of acres to be dedicated + $ development fee 0 Sanitary Sewer Lines # of acres in floodplain 390 Water Lines # of acres in detention 0 Channels # of acres in greenways 0 Storm Sewers OR 0 Bike Lanes / Paths FEE IN LIEU OF LAND: # of Single - Family Dwelling Units X $556 = $ (date) Approved by Parks & Recreation Board NOTE: DIGITAL COPY OF PLAT MUST BE SUBMITTED PRIOR TO FILING. The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true, correct, and complete. The undersigned hereby requests approval by the City of College Station of the above - identified final plat and attests that this request does not amend any covenants or restrictions associated with this plat. 3/; Signature and Title Date 6/13/03 2 of 2 SUPPLEMENTAL DEVELOPMENT PERMIT INFORMATION Application is hereby made for the following development specific site /waterway alterations: Comfort Inn, College Station, Texas Herman F. Krenek Phase II Lot 5 ACKNOWLEDGMENTS: I, Steve E. Duncan, P.E. , design engineer /owner, hereby acknowledge or affirm that: Th- infor ation . • conclusions contained in the above plans and supporting documents comply with the current r' quirem- nts •,,//; %City of College Station, Texas City Code, Chapter 13 and its associated Drainage Policy and Design .tandar ►s. condition of approval of this permit application, I agree to construct the improvements proposed in this a. •lica or - . •rding to these documents and the requirements of Chapter 13 of the College Station City Code. Property • ner(s) Contractor CERTIFICATIONS: (for proposed alterations within designated flood hazard areas.) A.I, Steve E. Duncan, P.E. wrl) by certify that any nonresidential structure on or proposed to be on this site as part of this application- iesignated to prevent damage to the structure or its contents as a result of flooding from the 100 years rm. '/ Engineer Date * w ;'l be B. I, Steve E. Duncan, P.E. certify that the finished floor ele ation of the lowest floor, including any basement, of any residential structure, proposed as part of this application • t or above the base flood elevation established in the latest Federal Insurance Administration Flood Hazard Study and maps, as amended. .g 42/ ' Engineer Date C. I, Steve E. Duncan, P.E. , certify that the alterations or development covered by this permit shall not diminish the flood- carrying capacity of the waterway adjoining or crossing this permitted site and that such alterations or development are consistent with requirements of the City of College Station City Code, Chapter 13 concerning encroachments of floodways and of floodway fringes. _ 12 I-,r/ Engineer Date D.I, Steve E. Duncan, P.E. , do certify that the proposed alterations do not raise the level of the 100 year flood bove ele tion established in the latest Federal Insurance Administration Flood Hazard Study. Engineer Date , A31 01 "/ Conditions or comments as part of approval: In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall apply. 6/13/03 3 of 3 SUBMIT APPLICATION AND THIS LIST CHECKED OFF WITH 13 FOLDED COPIES OF PLAT FOR REVIEW COLLEGE STATION FINAL PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: (Requirements based on field survey and marked by monuments and markers.) ▪ 1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. 1 2. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. ® 3. Title Block with the following information: E Name and address of subdivider, recorded owner, planner, engineer and surveyor. ® Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) (Replats need to retain original subdivision name.) p Date of preparation. E Engineer's scale in feet. ® Total area intended to be developed. ® 4. North Arrow. © 5. Subdivision boundary indicated by heavy lines. © 6. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. © 7. All applicable certifications based on the type of final plat. © Ownership and Dedication ® Surveyor and /or Engineer © City Engineer (and City Planner, if a minor plat) Fl Planning and Zoning Commission (delete if minor plat) © Brazos County Clerk © Brazos County Commissioners Court Approval (ETJ Plats only) ® 8. Paid tax certificates. • 9. If submitting a replat where there are existing improvements, submit a survey of the subject property showing the improvements to ensure that no encroachments will be created. • 10. If using private septic systems, add a general note on the plat that no private sewage facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioner's Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code. • 11. Location of the 100 Year Floodplain and floodway, if applicable, according to the most recent available data. • 12. Lot corner markers and survey monuments (by symbol) and clearly tied to basic survey data. • 13. Matches the approved preliminary plat and /or master development plan. 6/13/03 4 of4 [I 14. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as well as, those within the subdivision). Existing Proposed ® ® Streets. Continuous or end in a cul -de -sac, stubbed out streets must end into a temp turn around unless they are shorter than 100 feet. © p Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to meet Thoroughfare Plan.) © p Street offsets and /or intersection angles meet ordinance. • El Alleys. • p Easements. • © A number or letter to identify each lot or site and each block. ® ® Greenbelt area /park linkages /parkland dedication ( All proposed dedications must be reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.) x 15. Construction documents for all public infrastructure drawn on 24" x 36" sheets and properly sealed by a Licensed Texas Professional Engineer that include the following: N/A ❑ Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall street, alley and /or sidewalk layout of the subdivision. (may be combined with other utilities). N/A ❑ Sanitary sewer plan and profile showing depth and grades. One sheet must show the overall sewer layout of the subdivision. (Utilities of sufficient size /depth to meet the utility master plan and any future growth areas.) FUILRE ❑ Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing depth and grades. One sheet must show the overall water layout of the subdivision. (Utilities of sufficient size /depth to meet the utility master plan and any future growth areas.) N/A ❑ Storm drainage system plan with contours, street profile, inlets, storm sewer and drainage channels, with profiles and sections. Drainage and runoff areas, and runoff based on 5, 10, 25, 50 and 100 year rain intensity. Detailed drainage structure design, channel lining design & detention if used. One sheet must show the overall drainage layout of the subdivision. N/A ❑ Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E. N/A ❑ Drainage Report. N / A ❑ Erosion Control Plan (must be included in construction plans). 16. All off -site easements necessary for infrastructure construction must be shown on the final plat with a volume and page listed to indicate where the separate instrument easements were filed. Separate instrument easements must be filed prior or concurrently with Final Plat. • 17. Are there impact fees associated with this development? ['Yes ® No Impact fees for R -1, R -2, & R -3 zoned final plats, must be paid prior to filing. • 18. Will any construction occur in TexDOT rights -of -way? ❑ Yes © No If yes, TexDOT permit must be submitted along with the construction documents. NOTE: 1. We will be requesting the corrected Final Plat to be submitted in digital form if available prior to filing the plat at the Courthouse. 2. If the construction area is greater than 5 acres, EPA Notice of Intent (NOI) must be submitted prior to issuance of a development permit. 6/13/03 5 of 5 P Pledger Kalkomey, Inc. Bryan, Bryan, 7808 979- 731 -8000, 979 - 731 -1500 (Fax) K Consulting Engineers www pkengineering.com February 23, 2004 Ms. Bridgette George City of College Station P.O. Box 9960 College Station, Texas 77842 Re: Patel Comfort Inn PK Job No. 47504 -251 Dear Mrs. George, Enclosed please find the following: 1. Final Plat Application 2. Check No. 1022 dated February 19, 2004 in the amount of $800.00 for the $600.00 replat fee and the $200.00 development permit application fee. 3. Thirteen (13) copies of replat dated today. 4. Brazos County Appraisal District Statement of Account showing taxes paid on subject property for the past three years. Very Truly Yours, Steve E. Duncan, P.E. sedgpkengineeing.com SED /bap Enclosures CC: Craig Brown Nitin Patel Curtis Strong S. 200447504 -251 PA TEL- Comfort Inn :transmit rcplat.doc Brenham • Bryan • Rosenberg FOR OFFICE USE ONLY P &Z CASE NO.: DATE SUBMITTED: COLLEGE STATION FINAL PLAT APPLICATION (Check one) ❑ Minor ❑ Amending ❑ Final ❑ Vacating a Replat ($300.00) ($300.00) ($400.00) ($400.00) ($600.00)* *Includes public hearing fee The following items must be submitted by an established filing deadline date for P &Z Commission consideration. MINIMUM SUBMITTAL REQUIREMENTS: ■ Filing Fee (see above) NOTE: Multiple Sheets - $55.00 per additional sheet n/a Variance Request to Subdivision Regulations — $100 (if applicable) ti Development Permit Application Fee of $200.00 (if applicable). n/a Infrastructure Inspection Fee of $600.00 (applicable if any public infrastructure is being constructed) ti Application completed in full. n/a Copy of original deed restrictions /covenants for replats (if applicable). ti Thirteen (13) folded copies of plat. (A signed mylar original must be submitted after staff review.) n/a One (1) copy of the approved Preliminary Plat and /or one (1) Master Plan (if applicable). ti Paid tax certificates from City of College Station, Brazos County and College Station I.S.D. ti A copy of the attached checklist with all items checked off or a brief explanation as to why they are not. n/a Two (2) copies of public infrastructure plans associated with this plat (if applicable). n/a Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of approval (if applicable). Date of Preapplication Conference: December 15, 2003 NAME OF SUBDIVISION Herman F. Krenek, Phase II SPECIFIED LOCATION OF PROPOSED SUBDIVISION (Lot & Block) Lot 5 (2.937 ac. Vol. 930, Pq. 653) APPLICANT /PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name Steve E. Duncan, P.E. Street Address 7020 Coyote Run City Bryan State Texas Zip Code 77808 E -Mail Address sedpkenqineerinq.com Phone Number (979) 731 -8000 Fax Number (979) 731 -1500 PROPERTY OWNER'S INFORMATION: Name Charles R. & Lucy H. Farrar Street Address P.O. Box 9 City Monument State Texas Zip Code 80132 E -Mail Address Phone Number (719) 488 -0986 Fax Number (719) 481 -2153 ARCHITECT OR ENGINEER'S INFORMATION: Name Steve E. Duncan Street Address 7020 Coyote Run City Bryan State Texas Zip Code 77808 E - Mail Address sedCcilpkengineerinq.com Phone Number (979) 731 -8000 Fax Number (979) 731 -1500 ' i ()ri Is there a temporary blanket easement on this property? If so, please provide the Volume 737 and Page # 778 Acreage -V Total Property 2.97 Total # Of Lots 2 R -O -W Acreage 0 Existing Use: vacant Proposed Use: hotel Number Of Lots By Zoning District C -1 /2 / / Average Acreage Of Each Residential Lot By Zoning District: C -1 /1.469 / / / Floodplain Acreage 0 A statement addressing any differences between the Final Plat and approved Master Plan and /or Preliminary Plat (if applicable): Property is subdivided into two (2) 1.47 acre lots and a utility easement and a drainage and access easement are added to the front lot 5A Requested Variances To Subdivision Regulations & Reason For Same: n/a Requested Oversize Participation: Total Linear Footage of Parkland Dedication due prior to filing the Final Plat: Proposed Public: ACREAGE: n/a 0 Streets 0 Sidewalks # of acres to be dedicated + $ development fee 0 Sanitary Sewer Lines # of acres in floodplain 390 Water Lines # of acres in detention 0 Channels # of acres in greenways 0 Storm Sewers OR 0 Bike Lanes / Paths FEE IN LIEU OF LAND: # of Single - Family Dwelling Units X $556 = $ (date) Approved by Parks & Recreation Board NOTE: DIGITAL COPY OF PLAT MUST BE SUBMITTED PRIOR TO FILING. The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true, correct, and complete. The undersigned hereby requests approval by the City of College Station of the above - identified final plat and attests that this request does not amend any covenants or restrictions associated with this plat. aft .5/.2 l Signature and Title Date 6/13/03 2 "t SUPPLEMENTAL DEVELOPMENT PERMIT INFORMATION Application is hereby made for the following development specific site /waterway alterations: Comfort Inn, College Station, Texas Herman F. Krenek Phase II Lot 5 ACKNOWLEDGMENTS: I, Steve E. Duncan, P.E. , design engineer /owner, hereby acknowledge or affirm that: Th= infor ation -.. conclusions contained in the above plans and supporting documents comply with the current r' quirem: nts . ,,% rCity of College Station, Texas City Code, Chapter 13 and its associated Drainage Policy and Design ',tandar.s. ' / ondition of approval of this permit application, I agree to construct the improvements proposed in this a..Iica o : ' •rding to these documents and the requirements of Chapter 13 of the College Station City Code. Property • • ner(s) Contractor CERTIFICATIONS: (for proposed alterations within designated flood hazard areas.) A.I, Steve E. Duncan, P.E. w;I s be certify that any nonresidential structure on or proposed to be on this site as part of this application- iesignated to prevent damage to the structure or its contents as a result of flooding from the 100 years rm. •• s f Engineer Date ,,,,;11 be B. I, Steve E. Duncan, P.E. certify that the finished floor ele ation of the lowest floor, including any basement, of any residential structure, proposed as part of this application . t or above the base flood elevation established in the latest Federal Insurance Administration Flood Hazard Study and maps, as amended. .P7'?a•'-- / /B' /Oy Engineer Date // C. I, Steve E. Duncan, P.E. , certify that the alterations or development covered by this permit shall not diminish the flood- carrying capacity of the waterway adjoining or crossing this permitted site and that such alterations or development are consistent with requirements of the City of College Station City Code, Chapter 13 concerning encroachments of floodways and of floodway fringes. ._ An efr Engineer Date D.I, Steve E. Duncan, P.E. , do certify that the proposed alterations do not raise the level of the 100 year flood bove ele tion established in the latest Federal Insurance Administration Flood Hazard Study. 4S1 i i Engineer Date Conditions or comments as part of approval: In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall apply. 6/13'03 3 0i 3 SUBMIT APPLICATION AND THIS (11 LIST CHECKED OFF WITH 13 FOLDED COPIES OF PLAT FOR REVIEW COLLEGE STATION FINAL PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: (Requirements based on field survey and marked by monuments and markers.) x 1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. (J 2. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. 3. Title Block with the following information: Name and address of subdivider, recorded owner, planner, engineer and surveyor. E Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) (Replats need to retain original subdivision name.) © Date of preparation. E Engineer's scale in feet. E Total area intended to be developed. 4. North Arrow. X1 5. Subdivision boundary indicated by heavy lines. n 6. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. (xi 7. All applicable certifications based on the type of final plat. © Ownership and Dedication E Surveyor and /or Engineer © City Engineer (and City Planner, if a minor plat) E Planning and Zoning Commission (delete if minor plat) © Brazos County Clerk © Brazos County Commissioners Court Approval (ETJ Plats only) 8. Paid tax certificates. x 9. If submitting a replat where there are existing improvements, submit a survey of the subject property showing the improvements to ensure that no encroachments will be created. T 10. If using private septic systems, add a general note on the plat that no private sewage facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioner's Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code. x 11. Location of the 100 Year Floodplain and floodway, if applicable, according to the most recent available data. - 12. Lot corner markers and survey monuments (by symbol) and clearly tied to basic survey data. 13. Matches the approved preliminary plat and /or master development plan. 03 4 ul1 14. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as well as, those within the subdivision). Existing Proposed 1 ® Streets. Continuous or end in a cul -de -sac, stubbed out streets must end into a temp turn around unless they are shorter than 100 feet. © F Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to meet Thoroughfare Plan.) x� ❑ Street offsets and /or intersection angles meet ordinance. • C Alleys. • n Easements. • ❑x A number or letter to identify each lot or site and each block. E Greenbelt area /park linkages /parkland dedication ( All proposed dedications must be reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.) [xl 15. Construction documents for all public infrastructure drawn on 24" x 36" sheets and properly sealed by a Licensed Texas Professional Engineer that include the following: N/A ❑ Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall street, alley and /or sidewalk layout of the subdivision. (may be combined with other utilities). N/A ❑ S anitary sewer plan and profile showing depth and grades. One sheet must show the overall sewer layout of the subdivision. (Utilities of sufficient size /depth to meet the utility master plan and any future growth areas.) FURL E ❑ W ater line plan showing fire hydrants, valves, etc. with plan and profile lines showing depth and grades. One sheet must show the overall water layout of the subdivision. (Utilities of sufficient size /depth to meet the utility master plan and any future growth areas.) N/A ❑ Storm drainage system plan with contours, street profile, inlets, storm sewer and drainage channels, with profiles and sections. Drainage and runoff areas, and runoff based on 5, 10, 25, 50 and 100 year rain intensity. Detailed drainage structure design, channel lining design & detention if used. One sheet must show the overall drainage layout of the subdivision. N/A ❑ Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E. N/A ❑ Drainage Report. N/A ❑ Erosion Control Plan (must be included in construction plans). 16. All off -site easements necessary for infrastructure construction must be shown on the final plat with a volume and page listed to indicate where the separate instrument easements were filed. Separate instrument easements must be filed prior or concurrently with Final Plat. 17. Are there impact fees associated with this development? ❑ Yes E No Impact fees for R -1, R -2, & R -3 zoned final plats, must be paid prior to filing. 18. Will any construction occur in TexDOT rights -of -way? ❑ Yes © No If yes, TexDOT permit must be submitted along with the construction documents. NOTE: 1. We will be requesting the corrected Final Plat to be submitted in digital form if available prior to filing the plat at the Courthouse. 2. If the construction area is greater than 5 acres, EPA Notice of Intent (NOI) must be submitted prior to issuance of a development permit. 6/13/03 5 01 Statement Of Account Issue Date : 02/20/2004 This is a statement of taxes paid and due as of 02/20/2004 based upon the tax records of the Brazos County Appraisal District. Gerald L. "Buddy" Winn Brazos County This document is not a tax certificate and does not Tax Assessor / Collector absolve a taxpayer from tax liability in any way. 300 E. William J. Bryan Pkwy Should this document be found to be in error, it may be Bryan, TX 77803 -5397 corrected by the collection office. Responsibility to pay taxes remains with the taxpayer as outlined in the Texas Property Tax Code. Property Information Owner Information Property ID : R81960 Value Information Owner ID : 132154 Cross Ref 375000-0200-0050 Land HS $0 FARRAR, CHARLES R SR & LUCY Land NHS : $224,120 PO BOX 9 H F KRENEK #2, LOT 5, ACRES 2.94 Imp HS $0 MONUMENT, CO 80132 -0009 Imp NHS $0 Situs Addr Ag Mkt $0 Ag Use $0 Appraised : $224,120 HS Cap Adj : Assessed : $224,120 Bills Summary PAID BILLS SUMMARY Bill ID Tax Paid Disc P &I Att Fee Date Paid Amt P C2.01.37937 917.66 0.00 0.00 12/31/2001 917 C2.02.38992 917.66 0.00 0.00 12/19/2002 917 C2.03.40953 1,042.83 0.00 0.00 12/22/2003 1,042 G1.01.37937 806.82 0.00 0.00 12/31/2001 806 G1.02.38992 796.45 0.00 0.00 12/19/2002 796 G1.03.40953 974.92 0.00 0.00 12/22/2003 974 S2.01.37937 3,438.59 0.00 0.00 12/31/2001 3,438 S2.02.38992 3,438.59 0.00 0.00 12/19/2002 3,438 S2.03.40953 3,966.92 0.00 0.00 12/22/2003 3,966 Total Paid on Paid Bills: $16,300. Total Due for Property if Paid Before 03/01/2004: $0.