Loading...
HomeMy WebLinkAboutResposne to Staff Comments40' X° oV 6 1- 1 1. 2. 3. PLANNING 5. 6. 7. 8. STAFF REVIEW COMMENTS NO. 1 Project: TOWER POINT PH 12 (FP) - 11- 00500184 To increase density by adding a lot, a revised Preliminary Plat must be approved by the Planning and Zoning Commission. A revised preliminary plat is being submitted on Monday, December 19 along with the revisions to the Tower Point Ph. 12 final plat. Please add the public infrastructure information to Page 4 of the application. Public infrastructure information will be provided. There are additional easements mentioned in the title report that are not included on the plat. Also, please confirm that the easement on shown have the correct volume and page number. The information I have available shows that the easement labeled V8002 P249 is V723 P889 and easement V589 P 218 is V589 P 223, but these could be different easements. The title report identifies 10 easements. Of those 10, the following are applicable to Tower Point Subdivision, Phase 12: Vol. 589, Pg. 218 — shown on plat. Vol. 723, Pg. 689 — shown on plat. Vol. 4328, Pg. 164 — shown on plat. Vol. 5247, Pg. 82 — shown on plat. Vol. 8002, Pg. 249 — shown on plat. The easement information you have is incorrect. Vol. 8002, Pg. 249 is a 10' wide PUE adjoining the southeast right of way line of Arrington Road. Vol. 723, Pg. 689 (not 889) is a 20' wide — City of College Station electrical easement adjoining State Highway No. 6, both of which are shown on the final plat of Phase 12. Volume 589, Pg. 218, is a 15' wide City of College Station PUE, adjoining State Highway No. 6 and shown on the final plat of Phase 12. Volume 589, Pg. 223, is "Exhibit A" of Volume 589, Pg. 218. Since this building plot will not be required to provide pedestrian connection due to the size of the building plot, it will be important to note that a waiver to sidewalks along Hwy 6 was approved with the condition that internal pedestrian connectivity is provided according to Non - Residential Architectural Standards for building plots over 50,000 square feet. Acknowledged. Is the Sinclair blanket easement that showed up in the title report still in place? If so, can it be released yet? If not, please show that College Station easement will have priority. The Sinclair pipeline easement is a blanket easement, of which Tower Point is included. However, the pipeline is constructed 1.5 miles west of Tower Point. (See preliminary plat submitted in October, 2010). The blanket easement has not been released and there are no plans to release said blanket easement. Please note that any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that the City has not been made aware of will constitute a completely new review. Please note that you may be required to submit paid tax certificates if they are not current prior to the filing of your plat. The construction documents and reports are still under review and may affect the plat. Reviewed by: Lauren A. Hovde, Staff Planner Date: December 12, 2011 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2 of 3 TxDOT Comments 1. SH 6 frontage length and proximity to Arrington Road do not meet the guidelines for an access drive to the frontage road. All access to these lots should be from Arrington Road. Reviewed by: Chad Bohne Date: December 8, 2011 ENGINEERING COMMENTS NO. 1 1. Please clarify the purpose of the offsite 20'x28' PUE offsite. The 20'x28' PUE offsite is for a storm sewer outfall pipe serving Tower Point, Phase 12. 2. FYI...The public infrastructure plans are still in the process of being reviewed. R[Please note that public infrastructure to support this plat must be built or guaranteed prior to the final plat being forwarded to P &Z. Reviewed by: Erika Bridges Date: 12/12/11 SANITATION 1. Sanitation is ok with this project. Reviewed by: Wally Urrutia Date: December 8, 2011 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 3 of 3