Loading...
HomeMy WebLinkAboutDrawingsr 7wr 7w P.P. STA. 4+66.47: SANITARY SEWER LINE "Sl" 3"0 ADS STA. 4+66.47 to STA. 5+62.13: 4'0 RECEIVING MANHOLE S SEWER SANITARY SEWER LINE "Sl" ANG RT. - 270' 00' / PRIVATE FORCEMAIN IN MARION 1 0 PUGH R.O.W. Z- 6 0 0- NOTE- APPROXIMATE LOCA 60 L.F. OF ROAD BORE (DRY) w/ PRIOR TO CONNECTION OF 4" OF EXISTING 18" PUBLIC .84 L.F. OF 12 STEEL ENCASEMENT PRIVATE FORCEMAIN TO THE PUBLIC WATER LINE (3/8" WALL THICKNESS) & 96 L.F. SANITARY SEWER LINE THE N ' V , � 4" PVC CERTA-LOK (DR 18, CL CONTRACTOR SHALL VERIFY, TO T. M. 2 235) LOCKING JOINT CARRIER PIPE THE SATIFICATION OF THE CITY OF w/CASING & END SEALS 30 60 COLLEGE STATION, THAT THE ELEV. / =324,18' MWb PRIVATE SANITARY SEWER SYSTEM AND LIFT STATION IS WATER-TIGHT 2 A. 1. SCALE: 1" = 30' AND NOT PRODUCING AN INFLOW INFILTRATION PROBLEM. w S L.P. w /V 40' P.U.E (705/619) 00- STA. 3+06.21: SANITARY SEWER LINE "S1" 4'0 STANDARD MANHOLE #1 STA. 5+62.13: SANITARY SEWER LINE "Sl" STA. o+oo: SANITARY SEWER LINE "Sl" / / , ( 5 1-4" (MJ) 45 BEND TIE INTO EXISTING MANHOLE ANG RT.=116* 35' 23" � , P - P. / 'G.V. / ,\ �� �� I/ 0 4 - 1-4" (MJ) 11.25 BEND EXISTING 8" DIP PUBLIC REMOVE & REPLACE w/30 GAL. 1-4" (MJ) GATE VALVE & BOX > REMOVE & REPLACE w/30 GAL. s - 41� SANITARY SEWER LINE 30"0 ADS CALIPER) LIVE OAK (>2" CALIPER) RM SEWER Z LIVE OAK (>2 sio C. \ !Ld ly 25' P.U.E (705/61 8" PVC (SDR-26, D3034) F.H. PROPOSED s SANITARY SEWER LINE ')S1 3? C.O. CD TELEPHONE Ui WATER LINE "W1 VAULTS j"/ SEE SHEET C2.2 \ `'`�- 1��_,, / _ L. �i 2+ E. N 41'21'05" E L.P. T / /�, 1 1 1 3D PROPOSED b, PRIVATE FORCEMAIN, G. V. 3 TRAFFIC BENCHMARK DATA: F.H. SEE SHEET C1.3C q6 7_007- z SIGN Zy- UT T.B.M. ;� R.R. SPIKE IN POWERPOLE LOCATED IN THE SOUTHWEST CORNER OF THE INTERSECTION OF MARION APPROXIMATE LOCATION OF P. A R OA D. PUGH H D R IVE AND LUTHER R AD. UNDERGROUND TELEPHONE (ELEV. = 331.75*-NAD 83) APPROXIMATE LOCATION ELECTRICAL �� // _ AN 'OHe, OF EXISTING 8" PUBLIC HOLLEMAN DRIVE WEST VAULT T.B.M. #2.- SQUARE CHISELED IN SOUTHWEST CORNER OF WATER LINE (60' RIGHT-OF-WAY) TELEPFkNE CURB INLET LOCATED ON THE WEST SIDE OF MARION PUGH MARKER S DRIVE. CURB INLET LOCATED IS LOCATED JUST NORTH OF TELEPH ITS INTERSECTION WITH HOLLEMAN DRIVE. MARKER (ELEV. = 324.18'-NAD 83) APPROXIMATE LOCATION P. P. /*\—OF 10" WELLBORN PLAN NOTES: WATER LINE 1. REFER TO SHEETS COA & CO.2 FOR CONSTRUCTION s (D P, GV NOTES AND SPECIAL SPECIFICATIONS. CALL BEFORE YOU DIG 7 4 S APPROXIMAIE LOCAIION 9. REFER TO DETAIL SHEET C3.5 FOR MISCELLANEOUS TEXAS ONE CALL SYSTEM OF EXISTING 8" PUBLIC UTILITY DETAILS AND B/CS STANDARD DETAILS SHEETS 1-800-245-4545 WATER LINE FOR STREET, SIDEWALK, PAVING, DRAINAGE & UTILITY (AT LEAST 72 POURS PRIOR To DIGGING) : CONSTRUCTION. WARNING!!: THE CONTRACTOR IS TO LOCATE ANY AND ALL UTILITIES PRIOR TO CONSTRUCTION AND IS SOLELY RESPONSIBLE FOR ALL DAMAGES 01 3. THE EXISTING UTILITY LINES SHOWN ARE IN AN r TO EXISTING IfTILITTES TAIR TO AW CONSTRUCTION ACTIVITY, I V APPROXIMATE LOCATION/ f " APPROXIMATE WAY ONLY! NO UTILITY MAPS WERE 1v OF EXISTING 8 PUBLIC WATER LINE 0 F H AVAILABLE, BUT UTILITIES ARE SHOWN BASED FROM 20' P.U.E. . . MEETING(S) WITH THE UTILITY COMPANIES AND ABOVE (2948/89) GROUND UTILITY FEATURES, AS SHOWN. "S1" — PLAN VIEW STA. SCALE: 1 "=30' 0 vv S1 " — FARO HORZ: 1"=3C VERT 1"=3' 7607 EASTMARK DR., STE. 250F <77840> : OFFICE BOX 9253 _'OLLEGE STATION, TEXAS 77842 -'MAIL: civil@,miengineer.com DFFICE - (979) 764-0704 F AX - (979) 764-0704 TEXAS FIRM REGISTRATION No. F-4695 SURVEYOR KERR SURVEYING, LLC 505 CHURCH STREET COLLEGE STATION, TX 77841 OFF: (979) 268-3195 FAX: (979) 691-8904 V) Z> 0 0 cr_ F 2 F 0 W A-0-1- V) Z Lij z 5; 0(/) M < 0 0 :) x 0 Lij Cr -w W Z < 3: �'- x 0 329 U) < z J 0 Ld W + 0 u_ (/) Lij Z 0 L < 00 I U) >_ m C 0 uj N z < 0 Q Uj 0 M C z 329 326 < LLI z 0 00 0 V) _j LLJ 0 Z_ :r 77 < _0 _j _r z < _Z_ < _0 M LAJ U J 326 ----UJ,uj 3: _j 0 1'�j 2 Lo 323 e -r z z FX19TING @ GROUND C/L OF _(0 0 0 ui - [)f - W U) < 0 Z La < C14 F- -n U -14- Of __E­XIS —2 ROUND bi . L U) 0 C) C J LIJ-p fy 1- w -- KA A PIA U + —I0--w F__uj 0 U) 't 7) :2M 1-1-N A 7) m - N 323 x Z —PUGH -D- IRw— 320 < 8" PVC (SDR-26, D3034) �T_f ANITARY SEWER LINE "SI" s 30 ADS �TORM STA. 5+29 nn 3/_u STA. 4+8,' _10" WELL 30RIP WATER S _TA —4-+- 7- 7— SEWER...... F/ L­320.35' 317 0 Z .317 314 -- STA. 5+53 PROPOSED LINE "Wl" ST A .-4;:F F/L=316.89' -----WATER 311 _8 PVC (SDR-26, D3034) SANITARY SEWER LINE "S1 45 v STA. 4+66.47 to STA. 5+62.13: SANITARY SEWER LINE » S1 ». PRIVATE FORCEMAIN IN MARION PUGH R.O.W. 60 L.F. OF ROAD BORE (DRY) w/ 84 L.F. OF 12" STEEL' 308 ENCASEMENT (3/8" WALL THICKNESS) & 96 L.F. OF 4" PVC CERTA LOK (DR 18, CL 235) LOCKING JOINT CARRIER PIPE w/CASING SPACERS & END SEALS. 308 - OF aON 00 ff 474 -Z 305 2 00 Ld 305 00 n I 6 0 _j I- u_ LO _j L 4A _j LL: �0 pry _j LL- m LO _j u_ _j U-1 11- _j Ll�l r- _j L11 0 _j LL� _j U-1 rey 00- ____00__ _j LL_ - _j U- OD 0 _j U- 0') 23-13-L.E. _S1R_U_CnRAL_BAC_KEILL/_' OF It _j _j -IN u_ < 1 0+00 I 1+00 2+00 3 +00 ' 400 vv S1 " — FARO HORZ: 1"=3C VERT 1"=3' 7607 EASTMARK DR., STE. 250F <77840> : OFFICE BOX 9253 _'OLLEGE STATION, TEXAS 77842 -'MAIL: civil@,miengineer.com DFFICE - (979) 764-0704 F AX - (979) 764-0704 TEXAS FIRM REGISTRATION No. F-4695 SURVEYOR KERR SURVEYING, LLC 505 CHURCH STREET COLLEGE STATION, TX 77841 OFF: (979) 268-3195 FAX: (979) 691-8904 CLIENT INFORMATION AMERICAN CAMPUS COMMUNITIES ( OP) , LP c/o CHUCK CARROLL 12700 HILL COUNTRY BLVD., STE- T-200 AUSTIN, TX 78738 CCARROLL@AMERICANCAMPUS.COM PH: (512) 732-1000 �� F'11r: (512) 732-2450 SC& FILENAME: 0418S113 SCALE; AS NOTED w 01 SUBMITTED DATE: 2/23/11, 4/4/11, 4/20/11 Cum!, N CD E DRAWN BY: R.A.M. JAN "I OUR FIELD BOOK: : 13 R .A.M. PAGES: 46-75 COLLEGE sTATION RME CONSULTING ENGINEERS ENGINEERING CLIENT NO. PROJECT NO. - 178 — 0418 12, SHEET 240F 32 V) Z> 0 0 cr_ F 2 F 0 W A-0-1- V) Z Lij z 5; 0(/) M < 0 0 :) x 0 Lij Cr -w W Z < 3: �'- 0 F- 0 U) < z J 0 Ld W + 0 u_ (/) Lij Z 0 L < 00 I U) >_ m C 0 uj N z < 0 Q Uj 0 M z ) 0 CYl < 0 00 0 V) _j LLJ :r F_ CLIENT INFORMATION AMERICAN CAMPUS COMMUNITIES ( OP) , LP c/o CHUCK CARROLL 12700 HILL COUNTRY BLVD., STE- T-200 AUSTIN, TX 78738 CCARROLL@AMERICANCAMPUS.COM PH: (512) 732-1000 �� F'11r: (512) 732-2450 SC& FILENAME: 0418S113 SCALE; AS NOTED w 01 SUBMITTED DATE: 2/23/11, 4/4/11, 4/20/11 Cum!, N CD E DRAWN BY: R.A.M. JAN "I OUR FIELD BOOK: : 13 R .A.M. PAGES: 46-75 COLLEGE sTATION RME CONSULTING ENGINEERS ENGINEERING CLIENT NO. PROJECT NO. - 178 — 0418 12, SHEET 240F 32 30" 0 SANITARY SEWER MANHOLE RIM & COVER CONCRETE MANHOLE CAST /DUCTILE IRON COMBINATION & L MECHANICAL PLUG .° ' C• d -d 4 --/� /-4 " 45' (MJ) BEND MARK SLEEVING LOCATION w/3/8 "x2" GALVANIZED CARRIAGE BOLT :.a GRAVITY SEWER LINE GRAVITY SEWER LINE I \-RESTRAINED JOINT .4' SLEEVING (SEE PLANS FOR SIZE & TYPE) 4 "x 4" (MJ) WATER /SEWER CROSSING NOTES: SWEEPING WYE 1, REPLACE SANITARY SEWER, A MINIMUM OF 18' CENTERED ON THE WATER LINE, WITH SDR -26, CLASS 160, IF SEWER IS DISTURBED OR SHOWS EVIDENCE OF LEAKING. THIS WORK SHALL NOT BE PAID FOR DIRECTLY BUT SHALL BE CONSIDERED SUBSIDIARY TO THE VARIOUS BID ITEMS. 2. BOTH THE WATER LINE AND EXISTING SANITARY SEWER SHALL PASS A PRESSURE TEST IN ACCORDANCE WITH THE SPECIFICATIONS. 3. THIS MINIMUM DISTANCE MAY BE REDUCED TO 6" IF THE SANITARY LINE IS REPLACED WITH A 18' JOINT OF SDR -26 CLASS 160 PIPE AND CENTERED ON THE WATER LINE. BACKFILL NEW SANITARY SEWER LINE w /CEMENT STABILIZED SAND BEDDING A MINIMUM OF 20' CENTERED ON THE WATER LINE. RECEIVING MANHOLE N.T.S. SEAL END w /CEMENT GROUT OR MANUFACTURE'S SEAL F - I WATER LINE ui I I I I -r I \\ zz 9' (MIN I II ° \�\ / z I -- — ENCASEMENT PIPE (IF APPLICABLE), SEE DETAIL THIS SHEET VIA NOTE: WHERE A 9' SEPARATION DISTANCE CANNOT BE ACHIEVED, THE POTABLE WATER LINE SHALL BE ENCASED IN A JOINT OF PRESSURE CLASS PIPE, (SIZE W L 0 + 2 AND TYPE AS SHOWN ON THE PLANS). WHEN THE PIPE SIZES POTABLE WATER LINE IS ENCASED, THE ABSOLUTE MINIMUM SEPARATION DISTANCE SHALL NOT BE LESS THAN FOUR FEET. r PLACE BOLT IN CURB IF NO SIDEWALK IS SPECIFIED •- t e <.i - EXTEND SLEEVING 24" (MIN.) - z BEYOND PAVEMENT & SEAL, 0 0 TAPE OPENING (BOTH ENDS) N W sU) a \- EXI STI N G OR PROPOSED GRADE 18' -0" (MIN) CENTER JOINT OF PIPE OVFR SANITARY SEWER DIP WATER LINE (CLASS 350) EXISTING SANITARY SEWER LINE (SEE NOTE #1) ENCASEMENT PIPE, TRENCH SHORING — MINIMUM REQUIREMENTS _ 4k DEPTH z UPRIGHTS �o CROSS BRACES, WIDTH OF TRENCH z OF TRENCH (ft) cV w MINIMUM MAXIMUM MINIMUM MAXIMUM DIP WATER LINE (CLASS 350) EXISTING SANITARY SEWER LINE (SEE NOTE #1) ENCASEMENT PIPE, TRENCH SHORING — MINIMUM REQUIREMENTS _ SIZE & SPACING OF MEMBERS DEPTH KIND OR CONDITION UPRIGHTS STRINGERS CROSS BRACES, WIDTH OF TRENCH MAXIMUM SPACING OF TRENCH (ft) OF EARTH MINIMUM MAXIMUM MINIMUM MAXIMUM UP TO 3 3 TO 6 6 TO 9 9 TO 12 12 TO 15 AL OR(0 - a -(CLASS 350 ) - o MATCH SIZE OF DIMENSION SPACING DIMENSION SPACING FEET FEET FEET FEET FEET eft} mZ) (in) (ft) (in) (ft) (in) (in) (in) (in) (in) �o 0 p �- 3 x 4 o 0 U m � LLI 0 LJJ I o ® 5 TO 10 HARD, COMPACT OR 6 2 x 6 4 x 4 4 x 6 6 x 6 6 x 8 4 6 J m -' J 2x6 Lij ® 00 0 C) W 3 x 4 LIKELY TO CRACK OR 3 4x6 4 2x6 4x4 4x6 6x6 6x8 4 6 2 x 6 SOFT, SANDY, OR FILLED 3 x 4 OR CLOSE SHEETING 4 x 6 4 4 x 4 4 x 6 6 x 6 6 x 8 8 x8 4 6 2 x 6 HYDROSTATIC PRESSURE 3 x 4 OR CLOSE SHEETING 6 x 8 4 4 x 4 4 x 6 6 x 6 6 x 8 8 x 8 4 6 2 6 3 x 4 10 TO 15 HARD OR 4 4x6 4 4x4 4x6 6x6 6x8 8x8 4 6 2 x 6 3 x 4 LIKELY TO CRACK OR 2 4x6 4 4x4 4x6 6x6 6x8 8x8 6 2 x 6 SOFT, SANDY, OR FILLED 3 x 4 OR CLOSE SHEETING 4 x 6 4 4 x 6 6 x 6 6 x 8 8 x 8 8 x 10 4 6 2 x 6 HYDROSTATIC PRESSURE 3x6 CLOSE SHEETING 8 x 10 4 4x6 6x6 6x8 8x8 8 x 10 4 6 15 TO 20 ALL KINDS OR CONDITIONS 3x6 CLOSE SHEETING 4 x 12 4 4 x 12 6x8 8x8 8 x 10 10x10 4 6 OVER 20 ALL KINDS OR CONDITIONS 3x6 CLOSE SHEETING 6x8 4 4 x 12 8x8 8 x 10 10x10 10x12 1 4 6 1 TRENCH JACKS MAY BE USED IN LIEU OF, OR IN COMBINATION WITH, CROSS BRACES. SHORING IS NOT REQUIRED IN SOLID ROCK, HARD SHALE, OR HARD SLAG. WHERE POSSIBLE, STEEL SHEET PILING AND BRACING OF EQUAL STRENGTH MAY BE SUBSTITUTED FOR WOOD. MJ WYE 18' JOINT OF D.I.P. d w /10 MIL POLYWRAP ° 6,> +18 TYP I { ) N INFLUENT _ LIN x D.I. 0 BANDED ADAPTOR Lii FLOWLINE TO DUCTILE IRON PIPE MATCH SOFFIT OF - a -(CLASS 350 ) - o MATCH SIZE OF Z >x SEWER MAIN a - INFLUENT LINE j D.I.P. \i `•�MJ 90' y = . BEND \/ / EXTEND MANHOLE BASE TO SUPPORT D DROP CONNECTION DROP CONNECTION 24 0 SANITARY SEWER MANHOLE RING & COVER or BOLT DOWN WATERTIGHT RING & COVER ELEVATED 3" (MIN) RING & COVER (WT) ABOVE GRADE IN NON- PAVEMENT AREAS RING & COVER FLUSH w /GRADE IN PAVEMENT AREAS SEE NOTE #1 = PRECAST REINFORCED CONCRETE MANHOLE (ASTM C -478) RUBBER - GASKET JOINTS w /MORTAR SEALANT INSIDE AT ALL JOINTS SEE NOTE #5 9" (MAX) ---I PLUG (SIZE AS REQUIRED) --�� 5" (SEE NOTE #4) _ � 6 » " PER 12" MANHOLE BASE (SEE NOTE #3) MANHOLE FOUNDATION (SEE NOTE #3) SEAL END w /CEMENT GROUT OR MANUFACTURES SEAL •.�,.r.., • '�i /lam! /�� /lei #4 BARS @ 8" O.C.E.W. (NOTE: MANHOLES WITH DEPTHS #4 BARS BENT @ 90' & GREATER THAN 12' WILL REQUIRE 2 TIED TO WALL AND MATS OF REINFORCING STEEL) BASE ( 24" SPACING) STANDARD MANHOLE NOTES: 1. A MAXIMUM OF 4 AND A MINIMUM OF 2 THROAT RINGS SHALL BE USED AT EACH MANHOLE IN NEW OR EXISTING STREETS. 2. USE ADEKA SEALANT OR APPROVED EQUAL BETWEEN RING /COVER, ADJUSTMENT RINGS AND CHIMNEY OR CORBEL /CONE SECTION. 3. MANHOLE BASE THICKNESS AND FOUNDATION AS FOLLOWS: MANHOLE DEPTH BASE THICKNESS (ft) (in) 0 - 6 6" 6 - 12 6" PLUS 1' OF CEMENT STABILIZED SAND 12 & OVER 12" PLUS 1' OF CEMENT STABILIZED SAND 4. CONCRETE SHALL HAVE A STRENGTH OF 4,000 PSI AT 28 DAYS. 5. MANHOLE LOCATION AND COMPACTION AS FOLLOWS: LOCATION COMPACTION REQUIREMENT PAVEMENT 98% STANDARD PROCTOR ASTM D698 LANDSCAPED AREAS 90% STANDARD PROCTOR ASTM D698 ON —SITE PRIVATE STANDARD PRECAST MANHOLE N.T.S. _10) w� > Q a 0 a z Q (n J w > c� J r9 (.D rl) zCO a 0 w 0� Q CL .. U \ R! w a 0 U) ul C) w0 o� z w o� W > 0 z < a l• ato z l-., 0 < 0 1 w 0 d- 0 0 z 0 J r W •• '} N SPECIAL NOTES: 1. CLAYS, SILTS, LOAMS, OR NON- HOMOGENEOUS SOILS REQUIRE SHORING AND BRACING. 2. THE PRESENCE OF GROUND WATER REQUIRES SPECIAL TREATMENT. APPROXIMATE ANGLE OF REPOSE FOR SLOPING OF SIDES OF EXCAVATIONS 1. O.S.H.A. STANDARD 29 C.F.R. 1926.650 SHALL BE USED FOR THE DESIGN OF TRENCH SAFETY REQUIREMENTS. SHOULD THERE BE ANY CONFLICT BETWEEN THIS DRAWING AND C.F.R. 1926.650, THE O.S.H.A. STANDARD SHALL PREVAIL. 2. WHEN CONDITIONS ARE SATURATED OR SUBMERGED, USE THIGH SHEETING. THIGH SHEETING REFERS TO THE USE OF SPECIAL TIMBER PLANKS AT LEAST THREE INCHES THICK, STEEL SHEET PILING, OR SIMILAR CONSTRUCTION, THAT WHEN DRIVEN OR PLACED IN POSITION PROVIDE A TIGHT WALL TO RESIST THE LATERAL PRESSURE OF WATER. CLOSE SHEETING REFERS TO THE PLACEMENT OF PLANKS SIDE -BY -SIDE ALLOWING AS LITTLE SPACE AS POSSIBLE BETWEEN THEM. 3. ALL SPACING INDICATED IS MEASURED CENTER TO CENTER. 4. WALLS ARE TO BE INSTALLED WITH THE GREATER DIMENSION HORIZONTAL. 5. IF THE VERTICAL DISTANCE FROM THE CENTER OF THE LOWEST CROSS BRACE TO THE BOTTOM OF THE TRENCH EXCEEDS TWO AND ONE -HALF FEET, UPRIGHTS SHALL BE FIRMLY EMBEDDED OR A MUD SILL SHALL BE USED. WHERE UPRIGHTS ARE EMBEDDED, THE VERTICAL DISTANCE FROM THE CENTER OF THE LOWEST CROSS BRACE TO THE BOTTOM OF THE TRENCH SHALL NOT EXCEED 36 INCHES. WHEN MUD SILLS ARE USED, THE VERTICAL DISTANCE SHALL NOT EXCEED 42 INCHES. (NOTE: MUD SILLS ARE VALES THAT ARE INSTALLED AT THE TOE OF THE TRENCH SIDE.) 6. TRENCH JACKS MAY BE USED IN LIEU OF OR IN COMBINATION WITH TIMBER CROSS BRACES. 7. IF SHORING IS THE CHOSEN SUPPORT SYSTEM, THE INSTALLATION IS TO START FROM THE TOP OF THE TRENCH OR EXCAVATION AND WORK DOWNWARD. 8. SPOIL MUST BE STORED TWO FEET OR MORE FROM THE EDGE OF THE EXCAVATION, AND BE RETAINED IN AN EFFECTIVE MANNER. 9. WHEN HEAVY LOADS MUST BE LOCATED NEAR AN EXCAVATION, THE WALLS MUST BE BRACED, SHEET PILED OR SHORED TO SAFELY SUPPORT THE EXTRA WEIGHT. 10. DIVERSION DIKES AND DITCHES OR OTHER SUITABLE MEANS MUST BE USED TO PREVENT SURFACE WATER FROM ENTERING AN EXCAVATION AND TO PROVIDE ADEQUATE DRAINAGE OF THE AREA ADJACENT TO THE EXCAVATION. WATER IS NOT ALLOWED TO ACCUMULATE IN A TRENCH OR EXCAVATION. 11. AN ADEQUATE MEANS OF EXIT, SUCH AS A LADDER OR STEPS MUST BE PROVIDED AN LOCATED SO AS TO REQUIRE NO MORE THAN 25 FEET OF LATERAL TRAVEL. -A 7607 EASTMARK DR., STE_ 250F <77840> POST OFFICE SOX 9253 COLLEGE STA'T'ION, TEXAS 77842 EMAIL: civil. @rmengineer.com OFFICE - (979) 764 -0704 FAX - (979) 764 -0704 TEXAS FIRM REGISTRATION No. F4695 SURVEYOR KERR SURVEYING, LLC 505 CHURCH STREET COLLEGE STATION, TX 77841 OFF: (979) 268 -3195 FAX: (979) 691 -8904 W _ x 0 a Lii w = a� Z >x �� zx O ~ 0< �__0 mZ) o I— .3 0 — w Z < �o 0 p �- o 0 U m � LLI 0 LJJ I o ® o F-- ®� Ld z _j Y W W _ 0 J m -' J Lij ® 00 0 C) W CLIENT INFORMATION AMERICAN CAMPUS COMMUNITIES (OP), LP c/o CHUCK CARROLL 12700 HILL COUNTRY BLVD., STE. T -200 AUSTIN, TX 78738 CCARROLL@AMERICANCAMPUS.COM PH: (512) 732 -1000 F,•:: (51 q) 132 -2450 FILENAME: 0418CV1 B SCALE:AS NOTED SUBMITTED DATE: 2/23/11, 4/4/11, 4/20/11 DRAWN BY: R.A.M. CIILCKLD BY: R.A.M. FIELD BOOK: 13 PAGES: 46 -75 RME CONSULTING ENGINEERS CLIENT NO. PROJECT NO. 178 0418 SHEET �� OF 32 Sam r x a \\ a W w 0< o Sam r EXISTING 8" DIP PUBLIC SANITARY SEWER LINE 25' P.U.E (705/619) "SS File', ma STA. 4+66.47: SANITARY SEWER LINE "S1" P.P. �� STA. 4+66.47 to STA. 5+62.13: l 30" 0 ADS 4'0 RECEIVING MANHOLE #2STORM SEWER I / SANITARY SEINER LINE "S1" J / ANIG RT.=270' 00' 00" PRIVATE FOR(�EMAIN IN MARION PUGH R.O.W. APPROXIMATE LOCATION z`' / s .00, 60 L.F. OF ROAD BORE (DRY) w/ NOTE: OF EXISTING '18" PUBLIC r p &0'��y o 84 L.F. OF 1 STEEL ENCASEMENT PRIOR TO CONNECTION OF 4" WATER LINE / £ " PRIVATE FORCEMAIN TO THE PUBLIC / / / X 1 (3/8 WALL THICKNESS) & 96 L.F. SANITARY SEWER LINE THE J ;� /v / / OF 4" PVC CERTA-LOK (DR 18, CL CONTRACTOR SHALL VERIFY, TO p / sass?l 235) LOCKING JOINT CARRIER PIPE THE SATIFICATION OF THE CITY OF T. .M. 2 J e"F f w/CASING SPACL� & END SEALS COLLEGE STATION, THAT THE ELEV.=324.18' / _ / _ 06-N-- PRIVATE SANITARY SEWER SYSTEM 2 / / 4 I A. I. w AND LIFT STATION IS WATER -TIGHT AND NOT PRODUCING AN INFLOW/INFILTRATION PROBLEM. I. \ L.P. 40' P.U.E (705/619) /J / O - - ` - w C.I. r STA. 3+06.21: SANITARY SEWER LINE "S1" Q � j/ `�/ / STA. 5+62.13: SANITARY SEWER LINE "S1" STA. Q+OO: SANITARY SEWER LINE "S1" 4'0 STANDARD MANHOLE #1 TIE INTO EXISTING MANHOLE ANG RT.=116' 35' 23" / Pp .J �"� j // �,`� GV / 1-4",> (MJ) 45 BEND f � �� � 1-4" (MJ) GATE • BEND &BOX REMOVE & REPLACE w/30 GAL. REMOVE & REPLACE w/30 GAL. � ( ) LIVE OAK >2" CALIPER / 3o"b ADS,�►Z LIVE OAK (>2" CALIPER) ( ) S1 -ORM SEWER �yr / /q� ; � /^'3 F.H. 8" PVC (SDR -26, D3034) PROPOSEDiw G o 30 SCALE: I" = 30' w "1 WI _ W SANITARY SEWER LINE S1 6 p / WATER LINE "W1" ��' i 7 TELEPHONE / � VAULTS / / SEE SHEET C2.2 1+00 -- 2+00 � l y X4-0 // �/ / s L. P. A \ ; E.Tj N 41'21'05" EJ j �� // f f e f PROPOSED \ ,r TRAFFIC 3 PRIVATE . BENCHMARK DATA: $„w 8„w 8 Ww -7_0 UT SIGN J SEE SHEETHEET C13C 3C ° F. H. UT / �` T.B.M.11- R.R. SPIKE IN POWERPOLE LOCATED IN THE SOUTHWEST CORNER OF THE INTERSECTION OF MARION APPROXIMATE LOCAT10N OF �' � / - �_ . -�� -P. ` PUGH DRIVE AND LUTHER ROAD. UNDERGROUND TELEPHONE / / �' // �N `"`� (ELEV. = 331.75' -NAD 83) APPROXIMATE LOCATION TRICAL// _ ...ON `OHe- _ , � OF EXISTING 8' PUBLIC HOLLE AN DRIVE WEST ELECVAULT WATER LINE (60' RIGHT-OF-WAY) TELEMbN E pHE MARKER -0N6- _ j MARKER NE 60 s TSI' j CALL BEFORE YOU DIG TEXAS ONE CALL SYSTEI<I 1-800-245-4545 (AT LEAST 72 I1OURS PRIOR TO DIGGING) WARNING!!: THE CONTRACTOR IS TO LOCATE ANY AND .ALL UTILITIES PRIOR TO CONSTRUCTION AND IS SOLELY RESPONSIBLE FOR ALL DSL\{AGES TO E%ISTING IITTIATIRS DUE TO ;IVY CONSTRUCTTON ACTIVITY. P. P. 11 G.V. APPROXIMAIE LOCATION OF EXISTING 8” PUBLIC WATER LINE I // \ Y / APPROXIMATE LOCATION / \\\---OF 10” WELLBORN -I WATER LINE APPROXIMATE LOCATION OF EXISTING 8" PUBLIC -� WATER LINE 20' P.U.E._j (2948/89) „S1" _ PLAN VIEW - STA. 0+00 to EN® SCALE: 1"=30' T.B.M. -- SQUARE CHISELED IN SOUTHWEST CORNER OF �• 3 CURB INLET LOCATED ON THE WEST SIDE OF MARION PUGH �W DRIVE. CURB INLET LOCATED IS LOCATED JUST NORTH OF ITS INTERSECTION WITH HOLLEMAN DRIVE. (ELEV. = 324.18' -NAD 83) PLAN NOTES: 1. REFER TO SHEETS C0.1 & CO.2 FOR CONSTRUCTION NOTES AND SPECIAL SPECIFICATIONS. 2. REFER TO DETAIL SHEET C3.5 FOR MISCELLANEOUS UTILITY DETAILS AND B/CS STANDARD DETAILS SHEETS FOR STREET, SIDEWALK, PAVING, DRAINAGE & UTILITY CONSTRUCTION. 3. THE EXISTING UTILITY LINES SHOWN ARE IN AN APPROXIMATE WAY ONLY! NO UTILITY MAPS WERE AVAILABLE, BUT UTILITIES ARE SHOWN BASED FROM F. H. MEETINGS) WITH THE UTILITY COMPANIES AND ABOVE GROUND UTILITY FEATURES, AS SHOWN. 1 485179 PROF HORZ: 1"=30' VERT. 1"=3' r � 7607 EASTMAItK UK., STE. 250E <77846> POST OFFICE BOX 9253 COLLEGE STATION, TEXAS 77842 EMAIL: civil(a)rmengineerxom OFFICE - (979) 764-0704 FAX - (979) 764-0704 TEXAS FIRM REGISTRATION No. F-4695 SURVEYOR KERR SURVEYING, LLC 505 CHURCH STREET COLLEGE STATION, TX 77841 OFF: (979) 268-3195 FAX: (979) 691-8904 Z 1 'S/1� MAARION PUGH, TO 4^ PRIVATE FORCE GRADING ADJUSTMENTS THROUGH T 1 5/20/11 (+0.85') AND OTHER VARIOUS CHA C MARK DATE DESCRIPTION SUBSTANTIALLIF C UM Allhumm PETE ISSWED FOR CONSTRUCTION 12AftA 1' CONSTRUCTION DRAWING ISSUED PRIOR TO THIS DATE ARE REPLACED BY THIS SET & SHOULD NO BE USED FOR CONSTRUCTION. OF TE.i-� l� .. tt �....8... ...... ....� 8583 •� ,� N r — ' o w n W Z A UJ C) OW Zuj -� :2 Z 0 x W = � Q H 0 i-- 0 �- z W 0 0 Z (!i o W W W I O LL Q • 0 s�W Cm F_(n �0 Z 0 0 t�00 C W CLIENT INFORMATION AMERICAN CAMPUS COMMUNITIES (OP) LP c/o CHUCK CARROLL 12700 HILL COUNTRY BLVD_, STE- T-200 AUSTIN, TX 78738 CCARROLL@AMERICANCAMPUS.COM PH: (512) 732-1000 FX: (512) 732-2150 �Cfi .l.�jY `%� FILENAME: 0418S1 B SCALE: AS NO ED 1wV1 4� SUBMITTED DATE: 2/23/11, 4/4/11, 4/20;/11 '� � DRAWN BY: R.A.M. t JR4 i y CHECKED BY: R.A.M. 13 ! 1 FIELD BOOK: 13 PAGES: 46-75 )LLEGE STATIONRME CONSULTING ENGINEER ENGINEERINGCLIENT NO. PROJECT NIJ. 178 - 0418 SHEET 24 OF 32 —'< — 329 -- __ -- ___ _ __ _ __-_ __ - _ _ m_ - _ -_ 329 3� Z _ �_ _ o + -—I`>.-� t¢-- V) _ Lj ___ _ _ - - _— _ �_� �_ ...�-- _ ---. _-_ _ _ 326 L —_. __. J 323 — (n e z Q z 1= --_ _ - EXISTING @ ---5AT>fFA_R I ROUND �� C/L OF � - _ -SEWER"__ _. _ , — — Lil -z- �- W �_ to Q Q 0-0------ ¢ ►" tN �_Z � � _-_-_ d- fr_ - �XISTIN SANCTA_ -GROUND - I F . Y_SEaIVER-- ' --z — ---i-W_ Lil —� �_ • Lr► Q323 to 0 - O - Lo W-�rNj- Lr_ b1 � d- 0�_AA - — A 0to _ _ - - __ -_ -____ .-UJ z + �[3 �W Q ,�W to d Ca . r _.. s- - _,_,_,._-_-- _ _ �- 320 ..x 320 Q W �) ------------- - - .STA. - 8" PVC (SDR -26, D3034) SANITARY SEWER LINE "S1" _._- 30"0 ADS -� — - 5+ 9 _ h -.--- - . -• - - -_ __ STA. 4+8 10" WELL ORt WATER - - - -S-TA.--4-1 TORM SEWER _ _. -..1 r 8 1 ATE LIN �� LM321. • - - -- I -- -- --- --- FA -320.35 317 - -- - -- _WA -- 31. 31i 314LLA 311 ,� `�"" - --- STA. 5+53 -PROPOSED - WATER LINE "W1" -WATER ---F/L=316.89' 11 --� ��-�-- STA: 472:80- F- -BEM-- - _�__ - - 8" PVC (SDR -26, D3034) SANITARY SEWER LINE "S1" - ___� __- — - - --- — - _- 308 u 3®� STA. 4+66.47 to STA. 5+62.13: SANITARY SEWER LINE "S1" - PRIVATE FORCEMAIN IN MARION PUGH R.O.W. 60 L.F. OF ROAD BORE (DRY) w/ 84 L.F. OF 12" STEEL ENCASEMENT (3/8" WALL THICKNESS) & 96 L.F. OF 4" PVC. CERTA-LOK (DR 18, CL 235) LOCKING JOINT CARRIER PIPE w/CASING SPACERS & END SEALS. — ---- -- - - .-% ---^- — - - _-) -- - -- �- - �- - _ - - - -- RUCTUR-AL IZCKFILL - 00 - - 474. -1 -1 -C -OF -N -ON -S - - - -- -- - - �_ ^ �'� 305 305 M Co M ��.I�— ic) I� :- N - 1 ao II- d -� II - �- II i� - —� — - I I- J u r� - J .� r �,✓ J d a- 1 i-- _j� o i� �r —00 �- II �:- J CO - M _j d' °' ar 23_ 5� U C 3�.E.-OE _ RAL�ACKEI _ N L to -I P� •= _ uj- '� _I LL_ � LL -- Li _ t -- - .- lei J I�� L L. L' L� L� Li U- L1_ L� Q 0+00 1 +00 2+00 3+00 4+00 485179 PROF HORZ: 1"=30' VERT. 1"=3' r � 7607 EASTMAItK UK., STE. 250E <77846> POST OFFICE BOX 9253 COLLEGE STATION, TEXAS 77842 EMAIL: civil(a)rmengineerxom OFFICE - (979) 764-0704 FAX - (979) 764-0704 TEXAS FIRM REGISTRATION No. F-4695 SURVEYOR KERR SURVEYING, LLC 505 CHURCH STREET COLLEGE STATION, TX 77841 OFF: (979) 268-3195 FAX: (979) 691-8904 Z 1 'S/1� MAARION PUGH, TO 4^ PRIVATE FORCE GRADING ADJUSTMENTS THROUGH T 1 5/20/11 (+0.85') AND OTHER VARIOUS CHA C MARK DATE DESCRIPTION SUBSTANTIALLIF C UM Allhumm PETE ISSWED FOR CONSTRUCTION 12AftA 1' CONSTRUCTION DRAWING ISSUED PRIOR TO THIS DATE ARE REPLACED BY THIS SET & SHOULD NO BE USED FOR CONSTRUCTION. OF TE.i-� l� .. tt �....8... ...... ....� 8583 •� ,� N r — ' o w n W Z A UJ C) OW Zuj -� :2 Z 0 x W = � Q H 0 i-- 0 �- z W 0 0 Z (!i o W W W I O LL Q • 0 s�W Cm F_(n �0 Z 0 0 t�00 C W CLIENT INFORMATION AMERICAN CAMPUS COMMUNITIES (OP) LP c/o CHUCK CARROLL 12700 HILL COUNTRY BLVD_, STE- T-200 AUSTIN, TX 78738 CCARROLL@AMERICANCAMPUS.COM PH: (512) 732-1000 FX: (512) 732-2150 �Cfi .l.�jY `%� FILENAME: 0418S1 B SCALE: AS NO ED 1wV1 4� SUBMITTED DATE: 2/23/11, 4/4/11, 4/20;/11 '� � DRAWN BY: R.A.M. t JR4 i y CHECKED BY: R.A.M. 13 ! 1 FIELD BOOK: 13 PAGES: 46-75 )LLEGE STATIONRME CONSULTING ENGINEER ENGINEERINGCLIENT NO. PROJECT NIJ. 178 - 0418 SHEET 24 OF 32 30" 0 SANITARY SEWER MANHOLE RIM & COVER CONCRETE MANHOLE d 4 45' _(MJ) BEND CAST/DUCTILE IRON' -.A COMBINATION & MECHANICAL PLUG d a 4- RESTRAINED JOINT _4SWEEPING WYE tm ° d . GRAVITY SEWER LINE °a a RECEIVING MANHOLE N.T.S. MARK SLEEVING LOCATION PLACE BOLT IN CURB w/3/8"x2" GALVANIZED IF NO SIDEWALK IS SPECIFIED CARRIAGE BOLT EXTEND SLEEVING 24" (MIN.) _ Z /\/\\ b — BEYOND PAVEMENT &SEAL, 00 �N,1\1 TAPE OPENING (BOTH ENDS) WATER LINE/SANITARY SEWER -MANHOLE SEPARATION SLEEVING (SEE PLANS FOR SIZE & TYPE) U.T.S.IRRIGATION SLEEVING_ WATER /SEWER CROSSING NOTES: 1. REPLACE SANITARY SEWER, A MINIMUM OF 18' CENTERED ON THE WATER LINE, WITH SDR -26, CLASS 160, IF SEWER IS DISTURBED OR SHOWS EVIDENCE OF LEAKING. THIS WORK SHALL NOT BE PAID FOR DIRECTLY BUT SHALL BE CONSIDERED SUBSIDIARY TO THE VARIOUS BID ITEMS. 2. BOTH THE WATER LINE AND EXISTING SANITARY SEWER SHALL PASS A PRESSURE TEST IN ACCORDANCE WITH THE SPECIFICATIONS. 3. THIS MINIMUM DISTANCE MAY BE REDUCED TO 6" IF THE SANITARY LINE IS REPLACED WITH A 18' JOINT OF SDR -26 CLASS 160 PIPE AND CENTERED ON THE WATER LINE. BACKFILL NEW SANITARY SEWER LINE w/CEMENT STABILIZED SAND BEDDING A MINIMUM OF 20' CENTERED ON THE WATER LINE. N W J W � a- n C, r-1 SEAL END w/CEMENT z u BE ANY GROUT OR MANUFACTURE'S DEPTH KIND OR CONDITION UPRIGHTS STRINGERS CROSS BRACES, WIDTH OF ENCH SEAL r OF TRENCH OF EARTH MINIMUM MAXIMUM MINIMUM MAXIMUM UP TO 3 3 TO 6 6 TO 9 9 T (ft} cy � i TO 15 WATER LINE I I r I 0 z VERTICAL (ft} HORIZONTAL (ft) (In) (ft) (in) (ft) (in) (in) (in) ) zz i i(in) i 9' (MIN) I' `l 1l 0 � T - i D .., z ATER DIMENSION 1 11 0 0 ER OFjHE LOWEST CROSS BRACE TO -co LLJ D ONE; HALF FEET, UPRIGHTS SHALL w USED: WHERE UPRIGHTS ARE z 1 5 TO 10 !� w 0 6 LACHES. WHEN MUD SILLS ARE USED, THE VERTICAL DISTANCE SHALL NO 2 x 6 —ENCASEMENT PIPE (IF APPLICABLE), 4 x 6 6 j SEE DETAIL THIS SHEET 6 x 8 NOTE: WHERE A 9' SEPARATION DISTANCE CANNOT BE 6 ACHIEVED, THE POTABLE WATER LINE SHALL BE 2 x 6 ENCASED IN A JOINT OF PRESSURE CLASS PIPE, (SIZE STALLATION IS TO START W.L.0 + 2 'l AND WORK AND TYPE AS SHOWN ON THE PLANS). WHEN THE PIPE SIZES - FROM THE POTABLE WATER LINE IS ENCASED, THE ABSOLUTE AND BE RETAINED IN AN EFFECTIVE MANNER. MINIMUM SEPARATION DISTANCE SHALL NOT BE LESS R AN EXCAVATION, THE WALLS MUST THAN FOUR FEET. WATER LINE/SANITARY SEWER -MANHOLE SEPARATION SLEEVING (SEE PLANS FOR SIZE & TYPE) U.T.S.IRRIGATION SLEEVING_ WATER /SEWER CROSSING NOTES: 1. REPLACE SANITARY SEWER, A MINIMUM OF 18' CENTERED ON THE WATER LINE, WITH SDR -26, CLASS 160, IF SEWER IS DISTURBED OR SHOWS EVIDENCE OF LEAKING. THIS WORK SHALL NOT BE PAID FOR DIRECTLY BUT SHALL BE CONSIDERED SUBSIDIARY TO THE VARIOUS BID ITEMS. 2. BOTH THE WATER LINE AND EXISTING SANITARY SEWER SHALL PASS A PRESSURE TEST IN ACCORDANCE WITH THE SPECIFICATIONS. 3. THIS MINIMUM DISTANCE MAY BE REDUCED TO 6" IF THE SANITARY LINE IS REPLACED WITH A 18' JOINT OF SDR -26 CLASS 160 PIPE AND CENTERED ON THE WATER LINE. BACKFILL NEW SANITARY SEWER LINE w/CEMENT STABILIZED SAND BEDDING A MINIMUM OF 20' CENTERED ON THE WATER LINE. N W J W � a- n C, DIP WATER LINE (CLASS 350) •\�,�\,/�\��\ ��\��\��� \— EXI STING OR PROPOSED GRADE M 18'-0" (MIN) CENTER JOINT OF PIPE OVER SANITARY SEWER WATER LINE —EXISTING SANITARY SEWER LINE (SEE NOTE #1) /—ENCASEMENT PIPE, 10—V kMIN) ULN i tKtU UN JANI I ANY StWEH WATER LINE -SANITARY SEWER CROSSING( N. T.S. TRENCH SHORING - M-INIMUM REQUIREMENTS r-1 r z u BE ANY �C DEPTH KIND OR CONDITION UPRIGHTS STRINGERS CROSS BRACES, WIDTH OF ENCH cn ^ MAXIMUM SPACING OF TRENCH OF EARTH MINIMUM MAXIMUM MINIMUM MAXIMUM UP TO 3 3 TO 6 6 TO 9 9 T (ft} cy � 12 TO 15 L<1-!y\�i\%1i�%r�%r�!1� THICK, STEEL SHEET PILING, OR SIMILAR CONS r WHEN DRIVEN OR DIP WATER LINE (CLASS 350) •\�,�\,/�\��\ ��\��\��� \— EXI STING OR PROPOSED GRADE M 18'-0" (MIN) CENTER JOINT OF PIPE OVER SANITARY SEWER WATER LINE —EXISTING SANITARY SEWER LINE (SEE NOTE #1) /—ENCASEMENT PIPE, 10—V kMIN) ULN i tKtU UN JANI I ANY StWEH WATER LINE -SANITARY SEWER CROSSING( N. T.S. TRENCH SHORING - M-INIMUM REQUIREMENTS 0 r SIZE & SPACING OF MEMBERS BE ANY //z�� DEPTH KIND OR CONDITION UPRIGHTS STRINGERS CROSS BRACES, WIDTH OF ENCH cn ^ MAXIMUM SPACING OF TRENCH OF EARTH MINIMUM MAXIMUM MINIMUM MAXIMUM UP TO 3 3 TO 6 6 TO 9 9 T (ft} 12 12 TO 15 AT LEAST THREE INCHES THICK, STEEL SHEET PILING, OR SIMILAR CONS DIMENSION SPACING DIMENSION SPACING FEET FEET FEET FEET WHEN DRIVEN OR FEET z VERTICAL (ft} HORIZONTAL (ft) (In) (ft) (in) (ft) (in) (in) (in) ) 04 i(in) n w .. 0 � T >'N � 3 x 4 ATER DIMENSION HORIZONTAL. 5. IF THE VERTICAL DISTANCE FROM THE CEN ER OFjHE LOWEST CROSS BRACE TO THE BOTTOM OF THE TRENCH EXCEEDS TWO A D ONE; HALF FEET, UPRIGHTS SHALL BE FIRMLY EMBEDDED OR A MUD SILL SHALL BE USED: WHERE UPRIGHTS ARE EMBEDDED, THE VERTICAL DISTANCE FROM THE 5 TO 10 HARD, COMPACT OR 6 LACHES. WHEN MUD SILLS ARE USED, THE VERTICAL DISTANCE SHALL NO 2 x 6 4 x 4 4 x 6 6 j 6 6 x 8 4 6 2 x 6 M, THE I, STALLATION IS TO START FROM THE TOP OF THE TRENCH ` OR EXCAVATIO 'l AND WORK DOWNWARD. 8. SPOIL MUST BE STORED TWO FEET OR MOF - FROM THE EDGE OF THE EXCAVATION, AND BE RETAINED IN AN EFFECTIVE MANNER. 9. WHEN HEAVY LOADS MUST BE LOCATED N R AN EXCAVATION, THE WALLS MUST 3 x 4 Y SUPPORT THE EXTRA WEIGHT. 10. DIVERSION DIKES AND DITCHES OR OTHER SUITABLE AEANS MUST BE USED TO PREVENT SURFACE WATER FROM ENTERING AN EXCAVATION AND TO PROVIDE .ADEQUATE DRAINAGE OF THE AREA ADJACENT TO THE EX AVATION. WATER IS NOT ALLOWED TO ACCUMULATE IN A TRENCH OR EX AVATION. LIKELY TO CRACK2 OR 3 4 x 6 4 2 x 6 4 x 4 4 x 6 6 A 6 6' x 8 4 6 6 SOFT, SANDY, OR FILLED 3 x 4 OR CLOSE SHEETING 4 x 6 4 4 x 4 4 x 6 6 x 6 6' 8 8 x 8 4 6 2 x 6 HYDROSTATIC PRESSURE 3 x 4 OR CLOSE SHEETING 6 x 8 4 4 x 4 4 x 6 6 x 6 6 8 8 x 8 4 6 2 x 6 3 x 4 10 TO 15 HARD OR 4 4 x 6 4 4 x 4 4 x 6 6 x 6 6, 8 8x, 8 4 6 2 x 6 3 x 4 LIKELY TO CRACK OR 2 4 x 6 4 4 x 4 4 x 6 6 x 6 6 8 8 x 8 6 2 -x 6 SOFT, SANDY, OR FILLED 3 x 4 OR CLOSE SHEETING 4 x 6 4 4 x 6 6 x 6 6 x 8 81 8 8 x 10 4 6 2 x 6 HYDROSTATIC PRESSURE 3 x 6 CLOSE SHEETING 8 x 10 4 4 x 6 6 x 6 6 x8 8 8 8 x 10 4 6 15 TO 20 ALL KINDS OR CONDITIONS 3 x 6 CLOSE SHEETING 4x12 4 4x12 6 x 8 8 x 8 8x10 10 x10 4 6 OVER 20 ALL KINDS OR CONDITIONS 3 x 6 CLOSE SHEETING 6 x 8 4 4 x 12 8 x 8 8 x 10 10 10 i 10 x 12 4 6 inc!Num UHumo IVIH I DL U3r-U uv utU ur, VK 11V UUMbINA IIUN WI IH, LKU55 HHAGtS. SHUKING IS NOT REQUIRED IN SOLID ROCK, HARD SHALE, OR HARD SLAG. WHERE POSSIBLE, STEEL SHEET PILING AND BRACING OF EQUAL STRENGTH MAY BE SUBSTITUTED FOR WOOD. MJ WYE 18' JOINT OF D.I.P. d w/10 MIL POLYWRAP ( TYP ~� ) INFLUENT LINE BANDED ADAPTOR FLOWLINE TO o 18 DUCTILE IRON PIPE � MATCH �j\j�\jam a M i /j /j ♦ , (CLASS 350) — SOFFIT OF d o MATCH SIZE OF SEWER MAIN fr\/ INFLUENT LINE \\�X _ ra D.I.P. mi 90' BEND 'd a EXTEND MANHOLE BASE TO SUPPORT DROP CONNECTION DROP CONNECTION24" 0 SANITARY SEWER MANHOLE RING & COVER or BOLT DOWN WATERTIGHT RING & COVER ELEVATED 3 (MIN) RING & COVER (WT) ABOVE GRADE IN NON—PAVEMENT AREAS / / RING & COVER FLUSH w/GRADE IN PAVEMENT AREAS SEE NOT PRECAST REINFORCED CONCRETE MANHOLE (ASTM C-478) _ RUBBER—GASKET JOINTS w/MORTAR— SEALANT INSIDE AT ALL JOINTS SEE NOTE #5 — SEAL END w/CEMENT GROUT OR MANUFACTURES SEAL 0 N 4'-0" �\ w ry 5" (SEE NOTE #4) �\ °- W F- 9" (MAX) —•-' �' 0 PLUG (SIZE AS REQUIRED) ""�6" MANHOLE BASE (SEE NOTE #3)— MANHOLE FOUNDATION - _ PER 12" (SEE NOTE #3) #4 BARS Q 8" O.C.E.W. (NOTE: MANHOLES WITH DEPTHS #4 BARS BENT @ 90' & GREATER THAN 12' WILL REQUIRE 2 TIED TO WALL AND MATS OF REINFORCING STEEL) BASE ( 24" SPACING) STANDARD MANHOLE NOTES: 1. A MAXIMUM OF 4 AND A MINIMUM OF 2 THROAT RINGS SHALL BE USED AT EACH MANHOLE IN NEW OR EXISTING STREETS. 2. USE ADEKA SEALANT OR APPROVED EQUAL BETWEEN RING/COVER, ADJUSTMENT RINGS AND CHIMNEY OR CORBEL/CONE SECTION. 3. MANHOLE BASE THICKNESS AND FOUNDATION AS FOLLOWS: MANHOLE DEPTH BASE THICKNESS (ft) (in) 0— 6 6" 6 — 12 6" PLUS 1' OF CEMENT STABILIZED SAND 12 & OVER 12" PLUS 1' OF CEMENT STABILIZED SAND 4. CONCRETE SHALL HAVE A STRENGTH OF 4,000 PSI AT 28 DAYS. 5. MANHOLE LOCATION AND COMPACTION AS FOLLOWS: LOCATION COMPACTION REQUIREMENT PAVEMENT 98% STANDARD PROCTOR ASTM D698 LANDSCAPED AREAS 907 -STANDARD PROCTOR ASTM D698 ON-SITE PRIVATE STANDARD PRECAST MANHOLE N.T.S. 0 w 0) cr) 88 0 z Q V) i TRENCH SAFETY NOTES: 9 w CL 9 , 0 LO C, _j wo w ui w >' . . cr < , 1. CLAYS, SILTS, LOAMS, OR NON—HOMOGENEOUS SOILS REQUIRE SHOR NG AND BRACING. 2. TIE E RESENCE OF GROUND WATER REQUIRES SPECIAL TREATMENT. E OF, REPOSE 1. O.S.H.A. STANDARD 29 C.F.R. 1926.650 SH 0 FOR THE DESIGN OF TRENCH SAFETY REQUIREMENTS. SHOULD THEE BE ANY //z�� DRAWING AND C.F.R. 1926.650, THE O.S.H.A. STANDARD SHALL cn ^ o MERGED, USE d- 114- On _j(0 AT LEAST THREE INCHES THICK, STEEL SHEET PILING, OR SIMILAR CONS UCTION,HAT WHEN DRIVEN OR o z F_ 0 OF a' 04 r n w .. 0 � T >'N � 1. CLAYS, SILTS, LOAMS, OR NON—HOMOGENEOUS SOILS REQUIRE SHOR NG AND BRACING. 2. TIE E RESENCE OF GROUND WATER REQUIRES SPECIAL TREATMENT. E OF, REPOSE 1. O.S.H.A. STANDARD 29 C.F.R. 1926.650 SH LL BE USED FOR THE DESIGN OF TRENCH SAFETY REQUIREMENTS. SHOULD THEE BE ANY CONFLICT BETWEEN THIS DRAWING AND C.F.R. 1926.650, THE O.S.H.A. STANDARD SHALL PREVAIL. 2. WHEN CONDITIONS ARE SATURATED OR SUE MERGED, USE THIGH SHEETING. THIGH SHEETING REFERS TO THE USE OF SPECIAL TI ER PLANKS AT LEAST THREE INCHES THICK, STEEL SHEET PILING, OR SIMILAR CONS UCTION,HAT WHEN DRIVEN OR PLACED IN POSITION PROVIDE A TIGHT WALL T RESIST T�E LATERAL PRESSURE OF WATER. CLOSE SHEETING REFERS TO THE PLACEMENT OF PLANKS SIDE—BY—SIDE ALLOWING AS LITTLE SPACE AS POSSIBLE BET EN THEM. 3. ALL SPACING INDICATED IS MEASURED CEN 'ER TO CE i' TER. 4. WALLS ARE TO BE INSTALLED WITH THE GFE11 ATER DIMENSION HORIZONTAL. 5. IF THE VERTICAL DISTANCE FROM THE CEN ER OFjHE LOWEST CROSS BRACE TO THE BOTTOM OF THE TRENCH EXCEEDS TWO A D ONE; HALF FEET, UPRIGHTS SHALL BE FIRMLY EMBEDDED OR A MUD SILL SHALL BE USED: WHERE UPRIGHTS ARE EMBEDDED, THE VERTICAL DISTANCE FROM THE CENTER 0 THE LOWEST CROSS BRACE TO THE BOTTOM OF THE TRENCH SHALL NOT EXCEED '36 LACHES. WHEN MUD SILLS ARE USED, THE VERTICAL DISTANCE SHALL NO EXCEED 2 INCHES. (NOTE: MUD SILLS ARE VALES THAT ARE INSTALLED AT THE TOE OF THE TRENCH SIDE.) 6. TRENCH JACKS MAY BE USED IN LIEU OF f;R IN COMBINATION WITH TIMBER CROSS BRACES. 7. IF SHORING IS THE CHOSEN SUPPORT SYS M, THE I, STALLATION IS TO START FROM THE TOP OF THE TRENCH ` OR EXCAVATIO 'l AND WORK DOWNWARD. 8. SPOIL MUST BE STORED TWO FEET OR MOF - FROM THE EDGE OF THE EXCAVATION, AND BE RETAINED IN AN EFFECTIVE MANNER. 9. WHEN HEAVY LOADS MUST BE LOCATED N R AN EXCAVATION, THE WALLS MUST BE BRACED, SHEET PILED OR SHORED TO SAF Y SUPPORT THE EXTRA WEIGHT. 10. DIVERSION DIKES AND DITCHES OR OTHER SUITABLE AEANS MUST BE USED TO PREVENT SURFACE WATER FROM ENTERING AN EXCAVATION AND TO PROVIDE .ADEQUATE DRAINAGE OF THE AREA ADJACENT TO THE EX AVATION. WATER IS NOT ALLOWED TO ACCUMULATE IN A TRENCH OR EX AVATION. 11. AN ADEQUATE MEANS OF EXIT, SUCH AS! 1 LADDER � R STEPS MUST BE PROVIDED AN LOCATED SO AS TO REQUIRE NO MORE THA q 25 FEET OF LATERAL TRAVEL. F 7607 EASTMARK DR., STE. 250F <77 POST OFFICE BOX 9253 �'OLLEGE STA'T'ION, TEXAS 77842 EMAIL: civil(iibrmengineer.com DFFICE - (979) 764-0704 FAX - (979) 764-0704 TEXAS FM4 REGISTRATION No. F - SURVEYOR KERR SURVEYING, LLC 505 CHURCH STREET COLLEGE STATION, TX 77841 OFF: (979) 268-3195 FAX: (979) 691-8904 CHANGED MJ BEND AT ENTRY OF 2 1,5,112 RECEIVING MANHOLE GRADING ADJUSTMENTS THROUGH SITIE 1 5/20/11 (+0.85') AND OTHER VARIOUS CHAtIGES MARK DATE DESCRIPTION SUBSTANTIA L LEm. TE SAftAWAS E�Nft Aft, 3% 4/20111 CONSTRUCTION DRAWINGS' ISSUED PRIOR TO THIS DATE ARE REPLACED BY THIS SEI' & SHOULD NO BE USED FOR CONSTRUCTION. OF . B_ 8583 CLIENT INFORMATIORJ AMERICAN CAMPUS COMMUNITIES (OP), c/o CHUCK CARROLL 12700 HILL COUNTRY BLVD., STE. T-20 AUSTIN, TX 78738 CCARROLL@AMERICANCAM PUS.COM PH: (512) 732-1000 FX: (512) 732-2450 FILENAME: 0418CV1 B I SCALE:AS NOTE[ SUBMITTED DATE: 2/23/11, 4/4/11, 4/20, DRAWN BY: R.A.M. CIILCKLD BY: R.A.M. FIELD BOOK: 13 PAGES: 46-75 RME CONSULTING ENGINEERS CLIENT NO. PROJECT NO 175 0418 ■ SHEET 31 OF 32 • W �. .. • ify u) a. • LdLLJ i ! bi .. • CO . ui CLIENT INFORMATIORJ AMERICAN CAMPUS COMMUNITIES (OP), c/o CHUCK CARROLL 12700 HILL COUNTRY BLVD., STE. T-20 AUSTIN, TX 78738 CCARROLL@AMERICANCAM PUS.COM PH: (512) 732-1000 FX: (512) 732-2450 FILENAME: 0418CV1 B I SCALE:AS NOTE[ SUBMITTED DATE: 2/23/11, 4/4/11, 4/20, DRAWN BY: R.A.M. CIILCKLD BY: R.A.M. FIELD BOOK: 13 PAGES: 46-75 RME CONSULTING ENGINEERS CLIENT NO. PROJECT NO 175 0418 ■ SHEET 31 OF 32