Loading...
HomeMy WebLinkAboutApplication FOR OFFICE USE ONLY P&Z CASE NO.: b -42.3 DATE SUBMITTED: COLLEGE STATION SITE PLAN APPLICATION MINIMUM SUBMITTAL REQUIREMENTS Site plan application completed in full. ✓ _ $200.00 Application Fee. ✓ $200.00 Development Permit Application Fee. - 7 $600.00 Public Infrastructure Inspection Fee if applicable. (This fee is payable if construction of a public waterline, sewerline, sidewalk, street or drainage facilities is involved.) _ / Eleven (11) folded copies of site plan One (1) folded copy of the landscape plan. NIA One (1) copy of building elevation required for buildings with a footprint of 20,000 sq. ft. or greater N/ V A list of building materials for all facades that are visible from the public right -of -way. A copy of the attached site plan checklist with all items checked off or a brief explanation as to why they are / not checked off. V Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of approval (if applicable). Date of Preapplication Conference: Ongoing Phases NAME OF PROJECT Waterwood Condominimums, Phase 2 -A ADDRESS 1001 Krenek Tap Road LEGAL DESCRIPTION Lot 1 Block 1 E &M Jones Park Place APPLICANT /PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name Veronica J.B. Morgan, P.E., Mitchell & Morgan, LLP Street Address 511 University Drive East, Ste. 204 City College Station State TX Zip Code 77840 E -Mail Address v(mitchellandmorgan.com Phone Number (979) 260 -6963 Fax Number (979) 260 -3564 PROPERTY OWNER'S INFORMATION: Name Jim Stewart Street Address 4200 Woodland Park Court City Arlington State TX Zip Code 76013 E -Mail Address Phone Number (817) 994 -4663 Fax Number (817) 429 -8664 ARCHITECT OR ENGINEER'S INFORMATION: Name Veronica J.B. Morgan, P.E., Mitchell & Morgan, LLP Street Address 511 University Drive East, Ste. 204 City College Station State TX Zip Code 77840 E -Mail Address va.mitchellandmorgan.com Phone Number (979) 260 -6963 Fax Number (979) 260 -3564 6/13/03 1 of 6 OTHER CONTACTS (Please specify type of contact, i.e. project manager, potential buyer, local contact, etc.) Name None Street Address City State Zip Code E -Mail Address Phone Number Fax Number CURRENT ZONING R -4 PRESENT USE OF PROPERTY Vacant PROPOSED USE OF PROPERTY Condominimums VARIANCE(S) REQUESTED AND REASON(S) None # OF PARKING SPACES REQUIRED 88 # OF PARKING SPACES PROVIDED 172 MULTI - FAMILY RESIDENTIAL PARKLAND DEDICATION Total Acreage 13.72 # of Multi - Family Dwelling Units Floodplain Acreage 0 0 X $452 = $ Housing Units 25 0 # of acres in floodplain 0 # of 1 Bedroom Units 0 # of acres in detention 0 # of 2 Bedroom Units 0 # of acres in greenways 12 # of 3 Bedroom Units 0 date dedication approved by Parks Board 13 # of 4 Bedroom Units COMMERCIAL FOR 2 BEDROOM UNITS ONLY Total Acreage N/A N/A # Bedrooms = 132 sq. ft. Building Square Feet N/A N/A # Bedrooms < 132 sq. ft. Floodplain Acreage N/A NOTE: Parkland Dedication fee is due prior to the issuance of a Building Permit. The ap i I ant has prepared this application and certifies that the facts stated herein and exhibits attached hereto . - true and correct. i L f/C+ v, Signature of OwnerAgent •1. p:licant Date 6/13/03 2 of 6 A IA's` —.4/ V O ��// ��'' Q � SUBMIT APPLICATION AND THIS (14114 y V 1 4 LIST CHECKED OFF WITH 10 FOLDED COPIES OF SITE PLAN FOR REVIEW COULCL SIATION — 0 2 - 2 j utt SITE PLAN MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: • 1. /Sheet size - 24" x 36" (minimum). Lie 2. ✓ A key map (not necessarily to scale). 2/ 3. Title block to include: C3� ■dame, address, location, and legal description Ci/ Name, address, and telephone number of applicant CY /(lame, address, and telephone number of developer /owner (if differs from applicant) I /fjYame, address, and telephone number of architect/engineer (if differs from applicant) U1/ pate of submittal 0� VTotal site area lY 4. ✓North arrow. • 5. /Scale should be largest standard engineering scale possible on sheet. 3 6. \/Ownership and current zoning of parcel and all abutting parcels. 4/ 7. xistin locations of the following on or adjacent to the subject site: • Streets and sidewalks (R.O.W.). Apriveways (opposite and adjacent per Section 7.3 of the Unified Development Ordinance). C3 /Buildings. d!� - VVater courses. • Show all easements clearly designating as existing and type (utility, access, etc.). 7 a /q /100 yr. floodplain and flood way (if applicable) on or adjacent to the proposed project site, note if there is none on the site.KidL G✓ t, Utilities (noting size and designate as existing) within or adjacent to the proposed site, including building transformer locations, above ground and underground service connections to buildings, and drainage inlets. ( / Meter locations. CiY wTopography (2' max or spot elevations) and other pertinent drainage information. (If plan has too much information, show drainage on separate sheet.) GI 8. Proposed location, type and dimensions of the following.: eS l!`u t r f iv C� o�Pl asing. Each phase must be able to stand alone to meet ordinance requirements. q/ 'the gross square footage of all buildings and structures and the proposed use of each. If different uses are to be located in a single building, show the location and size of the uses within the building. Building separation is a minimum of 15 feet w/o additional fire protection. d \,, Setbacks. Show building setbacks as outlined in the Unified Development Ordinance, icle 5. oi Off - Street parking areas with parking spaces drawn, tabulated, and dimensioned. Minimum parking space is 9' x 20', or on a perimeter row 9' x 18' with a 2' overhang. Designate number of picking spaces required by ordinance and provided by proposal. vt- landicap parking spaces. 6/13/03 4 of 6 VAI — rob) P - where there may be conflict with handicap accessible routes or above ground utilities, signs or — / other conflicts. U3" 11. /Show curb and pavement detail. A 6" raised curb is required around all edges of all parts of all paved areas without exception. (To include island, planting areas, access ways, dumpster locations, utility pads, etc.) No exception will be made for areas designated as "reserved for future parking ". GI/ 12. tandscape plans as required in Section 7.5 of the Unified Development Ordinance. The V landscaping plan can be shown on a separate sheet if too much information is on the original site plan. If requesting protected tree points, then those trees need to be shown appropriately barricaded on the landscape plan. Attempt to reduce or eliminate plantings in easements. Include information on the plans such as: required point calculations \J5 1i 4 /A additional streetscape points required. Streetscape compliance is required on all streets) (\- CV calculations for # of street trees req d and proposed (proposed street tree points will accrue toward total landscaping points.) proposed new plantings with points earned proposed locations of new plantings „/- screening of parking Tots, 50 % of all shrubs used for screening shall be evergreen. scr�een_ing ofd_ u 1p rs, concrete retaining walls, off street loading areasiiitility connection point's, or other areas potentially visually offensive. O'NC4- existing landscaping to remain ,show existing trees to be barricaded and barricade plan. Protected points will only be awarded is issued. - - if barricades are up before the first Buffer as required in Section 7.6 of the Unified Development permit Deve o ment O dinance. : (t' i i 13. Show irrigation system plan. (or provide note on how irrigation system requirement will be met prior to issuance of C.O.) All plans must include irrigation systems for landscaping. Irrigation meters are separate from the regular water systems for buildings and will be sized by city according to irrigation demand submitted by applicant and must include backflow prevention protection. GI/ 14. Is there any landscaping in TxDOT R.O.W.? Yes ❑ 1,Ato If yes, then TxDOT permit must be submitted. 15. Will there be any utilities in TxDOT R.O.W.? Yes ❑ 04o If yes, then TxDOT permit must be submitted. LY 16. Will there be access from a TxDOT R.O.W.? Yes ❑ L.Xo If yes, then TxDOT permit must be submitted. 17. Vthe total number of multi - family buildings and units to be constructed on the proposed project / site. Li 18. /The density of dwelling units per acre of the proposed project. f ,, 19. Provide a water and sanitary sewer legend to include water demands (minimum, maximum and average demands in ga Ions per minute) and sewer loadings (maximum demands in gallons per day). 20. Are there impact fees associated with this development? Yes ❑ No r. ,i NOTE: Signs are to be permitted separately. 6/13/03 6 of 6 WAT Wo00 Parking Islands. Raised landscape islands, (6" raised curb) a minimum of 180 sq. ft. are required at both ends of every parking row (greenspace area contiguous to the end island maybe applied toward the required 180 sq. ft.). Additionally, 180 sq. ft. of landscaping for every 15 interior parking spaces must be provided. All required islands must be landscaped or set with decorative ,avers, or stamped dyed concrete or other decorative materials as approved. GY ✓ Drives. Minimum drive aisle width. Uel pc ,Curb cuts. For each proposed curb cut (including driveways, streets, alleys, etc.) locate existing curb cuts on the same opposite side of the street to determine separation distances between existing and proposed curb cuts. Indicate driveway throat length as measured in the Unified Development Ordinance, Section 7.3 Access Management and Circulation. (IN Pt+i) I3:0\ Security gates (show swing path and design specs with colors). q/ ✓Sidewalks (both public and private). Sidewalks are required at time of development if property has I's iffy frontage on a street shown on the Sidewalk Master Plan or if the review staff determines the necessity. 6/At/Medians. Show any and all traffic medians to be constructed on site. 41A vA fifteen foot parking setback from R.O.W. to curb of parking lot is required. Pavement may encroach into this 15' setback by up to 7 contiguous parking spaces. A double parking island (360 square feet) must be provided between each group of seven spaces. In no case may the pavement be less than 6' from the property line. ®JIAri Common open spaces sites WON/Loading docks 0 yl FN 11 Lt //\ (/Detention ponds II:2)0, l/-Guardrails G7/ ✓ Retaining walls It / , fr 24l 4 - L4/' p 1 , 1 /Sites for solid waste con iners with screenin . Locations of dumpsters are accessible but not visible from streets or residential areas. Gates are discouraged and visual screening is required. / ' (Minimum 2x 12 pad required.) (I Show all easements cleanly designating as proposed and type (utility, access, etc.). If dedicated by se instrument list by volume and page. Lif e Utilities (noting size and designate as proposed) within or adjacent to the proposed site, including building transformer locations, above ground and underground service connections to buildings. air t.Meterlocations (must be located in public R.O.W. or public utility easement.). LlY Proposed grading (1' max for proposed or spot elevations) and other pertinent drainage information. (If plan has too much information, show drainage on separate sheet.) CV vbhow proposed and existing fire hydrants. Fire hydrants must be located on the same side of a major street as a project, and shall be in a location approved by the City Engineer. Any structure in any zoning district other than R -1, R -1A, or R -2 must be within 300 feet of a fire hydrant as measured along a public street, highway or designated fire lane. )IA fire department connections. FDC's should be within 150' of the fire hydrant. In no case shall they be any further than 300' apart, and they shall be accessible from the parking lot without being blocked by parked cars or a structure. L , Show fire lanes. Fire lanes a minimum of 20 feet in width with a minimum height clearance of 14 V feet must be established if any portion of the proposed structure is more than 150 feet from the curb line or pavement edge of a public street or highway. NOTE: ✓ Fire hydrants must be operable and accepted by the City, and drives must have an all weather surface as defined in the Zoning Ordinance Section 9 before a building permit can be issued. lii(� 9. V Will building be sprinkled? Yes ❑ No UK" If the decision to sprinkle is made after the site plan has been approved, then the plan must be resubmitted. C�04\' 10. �' Wheelstops may be required when cars overhang onto property not owned by the applicant or `NIA 6/13/03 5 of 6