Loading...
HomeMy WebLinkAboutSTAFF COMMENTS CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 COLLEGE STATION Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM September 11, 2003 TO: Veronica J. B. Morgan, Mitchell & Morgan, LLP, Via fax 979.260.3564 ✓ FROM: Bridgette George, Assistant Development Manager SUBJECT: GATEWAY L10A & 10B (FP) - Final Plat Staff reviewed the above - mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. If all comments have been addressed and the following information submitted by Monday, October 6, 10:00 a.m., your project will be placed on the next available Planning and Zoning Commission meeting scheduled for, October 16, 2003, 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue. Two (2) copies of the revised final plat; One (1) Mylar original of the revised final plat; and One (1) copy of the digital file of the final plat on diskette or e-mail to nmanhart @ci.college- station.tx.us Upon receipt of the required documents for the Planning & Zoning meeting, your project will be considered formally filed with the City of College Station. Please note that if all comments have not been addressed your project will not be scheduled for a Planning & Zoning Commission meeting. Your project may be placed on a future agenda once all the revisions have been made and the appropriate fees paid. If you have any questions or need additional information, please call Spencer Thompson or myself at 764 -3570. Attachments: Staff review comments 5A3 cc: John Keen, Darden Restaurants, Via fax 407.245..4.3*6 Case file #03- 00500222 Home of Texas AB&M University STAFF REVIEW COMMENTS NO. 1 Project: GATEWAY L10A & 10B (FP) - 03- 00500222 ENGINEERING 1. No comments unless Site Plan changes affect plat. Reviewed by: Spencer Thompson Date: September 11, 2003 ELECTRICAL 1. Developer installs conduit per city specs and design. 2. Developer provides 30' of #4 rigid conduit for riser poles. Developer installs first 10'. City installs remainder. 3. Developer pours transformer pad(s) per city specs and design. 4. Developer installs pull boxes as per city specs and design.(pull boxes provided by the city. 5. Developer provides digital AutoCAD 2000i version of plat and /or site plan. email to rbolin(�cstx.gov 6. Developer provides load data for project. 7. Developer provides temporary blanket easement for construction purposes. 8. Developer provides easements for electric infrastructure as installed for electric lines. Reviewed by: Ronnie Bolin Date: 9 -11 -03 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 2 of 2 MEMORANDUM October 7, 2003 TO: Planning and Zoning Commission FROM: Spencer Thompson Email: sthompson@cstx.gov SUBJECT: REPLAT for GATEWAY PHASE 1, LOT 10A & 10B Item: Public hearing, discussion, and possible action on a Replat Gateway Phase 1, Lot 10A & 10B consisting of 2 lots on 3.1 acres generally located at 510 Earl Rudder Freeway South. Applicant: Mitchell and Morgan, Agent Staff Recommendations: Staff recommends approval of the Replat with the conditions set forth in Staff Comments #2. Item Summary: This item is for the consideration of a Replat for Lots 10A and 10B, Gateway Phase 1. The subject property is zoned C -1. All Tots meet City zoning requirements as set out in the UDO. Utilities are existing for Lot 10 and will be extended to create Lots 10A and 10B. The location is technically in the floodplain. However, a LOMR is being processed through FEMA to remove it from the Special Flood Hazard Area. The plat should note this fact as stated in the comments. Comprehensive Plan Considerations: Land Use Plan: Shown as commercial. Thoroughfare Plan: Earl Rudder Freeway is a Freeway/ expressway. Parkland Dedication: N/A on commercial property. Open Space Dedication: None. Special Area Plans: This site is not a part of the University Drive Overlay District. Budgetary & Financial Summary: None Attachments: 1. Area map 2. Application 3. Plat on wall in Council Chambers 4. Staff Comments #2 STAFF REVIEW COMMENTS NO. 2 Project: GATEWAY L10A & 10B (FP) - 03- 00500222 ENGINEERING 1. It appears the note concerning the floodplain is not entirely accurate. The subject property is in the SFHA as shown on FIRM Panel # 48041C0142. Please state such in Note #4. The property will no longer be in the SFHA when a LOMR is issued by FEMA. Reviewed by: Spencer Thompson Date: October 7, 2003