HomeMy WebLinkAboutSTAFF REPORT STAFF REPORT
Project Manager: Molly Hitchcock Date: December 11, 2003
Email: mhitchcock @cstx.gov
Item: Consideration, discussion, and possible action on:
1) a variance request to Section 8 -G.6 of the Subdivision Regulations concerning
minimum turnaround dimensions of cul -de -sacs,
2) a variance request to Section 12 -1.4 concerning street jogs, and
3) a preliminary plat
for The Glade Section 12 consisting of 17 lots on 3.03 acres generally located off
of Southwest Parkway across from Southwood Drive.
Applicant: S.M. Kling of Kling Engineering and Surveying as agent for Charles
Bergstrom, III
Staff Recommendations: If the Commission rules in favor of the variance
requests, Staff recommends approval of the preliminary plat. If the Commission
denies one or both of the variance requests, the plat shall be denied.
Item Summary: This preliminary plat consists of 17 lots on 3.03 acres zoned R -1
Single Family Residential. The property is surrounded by developed single family
to the west, north, and east, and Southwest Parkway to the south. The preliminary
plat is in preparation of a single family infill development.
Section 8 -G.6 of the Subdivision Regulations states:
Cul -de -sacs shall have twenty -four (24) or fewer lots, and shall terminate in a
turnaround not less than one hundred feet (100') in diameter, with a pavement
diameter of eighty feet (80').
The cul -de -sac turnaround is not configured with a consistent diameter; thus the
ROW and pavement width do not meet the minimum requirements. The cul -de-
sac does meet the minimum requirements for a fire truck turnaround. The City Fire
Marshall has approved the configuration for Fire purposes. It may be determined
at a later date that parking will be prohibited at the end of the cul -de -sac due to the
decreased turnaround area.
Section 12 -1.4 states:
Whenever possible, street jogs with centerline offsets of less than one hundred
twenty -five feet (125') shall be avoided.
The proposed right -of -way has been moved as far west as possible from
Southwood Drive (120 feet) in consideration of the minimum lot depths for the lots
on the western side of the street and the location of existing residential streets to
the west. Development engineering staff and the Transportation Planner have
reviewed the proposed location of the street and agree that the street as shown is
in the most appropriate location.
Please note Staff does not support or oppose variance requests. Staff provides
technical information to the Commission to assist in analyzing whether the
variance is necessary and the impacts if the variance is granted.
Although setbacks are shown on the preliminary plat, approval of the plat does not
confirm these distances. The UDO at this time allows for a different front setback
depending on the configuration of a home's parking. If such a setback may be
allowed will be determined at the time of building permit.
Comprehensive Plan Considerations: The property is shown on the Land Use
Plan as Single Family Medium Density (3 -6 dwelling units /acre) and is in
compliance with the plan (5.61 DU /acre). The subdivision will access Southwest
Parkway, which is a minor arterial on the Thoroughfare Plan.
Item Background: The subject property was annexed into the city in 1968 and
has always been zoned for single family. A rezoning to R1 -A was requested in
March 2003, but the request was pulled before it went to the City Council.
Related Advisory Board Recommendations: On October 14, 2003, the Parks
Board agreed to a cash dedication in lieu of land for the proposed plat.
Supporting Materials:
1. Location Map
2. Application
3. Infrastructure and Facilities
4. Copy of Preliminary Plat
INFRASTRUCTURE AND FACILITIES
Water required for plat: Domestic water and fire flow capacity are
required in order to plat the property as shown.
Water Service: Domestic service is required to all platted lots.
Sewer required for plat: Existing sewer is available to the site.
Sewer Service: Sewer is required to be extended to all platted lots.
Street(s) required for plat: The plat shows the construction of Limestone
Drive.
Streets /Access: Access from residential properties will be restricted to
Limestone.
Off -site Easements required for plat: None
Drainage: The development is required to comply with the City's Drainage
Policy. The City storm sewer system, including street and pipe capacity, is
designed for the 10 -yr storm. Capacity of the existing system will have to
be ensured by the project engineer.
Flood Plain: None.
Oversize request: None.
Impact Fees: None.
Parkland Dedication Fees: Parkland and development fees will be
required for the 16 new Tots to be platted ($556.00/lot).
STAFF REPORT
Project Manager: Jennifer Reeves Date: December 11, 2003
Email: jreeves @cstx.gov
Item: Public hearing, discussion, and possible action on a preliminary plat for The
Glade Section 12 consisting of 17 lots on 3.03 acres generally located off of
Southwest Parkway across from Southwood Drive.
Applicant: S.M. Kling of Kling Engineering and Surveying as agent for Charles
Bergstrom, 111
Staff Recommendations: Staff recommends approval of the preliminary plat as
submitted.
Item Summary: This preliminary plat consists of 17 lots on 3.03 acres zoned R -1
Single Family Residential. The property is surrounded by developed single family
to the west, north, and east, and Southwest Parkway to the south. The preliminary
plat is in preparation of a single family infill development.
Although setbacks are shown on the preliminary plat, approval of the plat does not
confirm these distances. The UDO at this time allows for a different front setback
depending on the configuration of a home's parking. Such a setback may be
allowed, and will be determined at the time of building permit.
Previously two variances were being requested, one to Section 8 -G.6 of the
Subdivision Regulations concerning minimum turnaround dimensions of cul -de-
sacs, and the other variance request was to Section 12 -1.4 concerning street jogs.
Since the first submittal these two requests have been retracted and are no longer
needed.
Comprehensive Plan Considerations: The property is shown on the Land Use
Plan as Single Family Medium Density (3 -6 dwelling units /acre) and is in
compliance with the plan (5.61 DU /acre). The subdivision will access Southwest
Parkway, which is a minor arterial on the Thoroughfare Plan.
Item Background: The subject property was annexed into the city in 1968 and
has always been zoned for single family. A rezoning to R1 -A was requested in
March 2003, but the request was pulled before it went to the City Council.
Related Advisory Board Recommendations: On October 14, 2003, the Parks
Board agreed to a cash dedication in lieu of land for the proposed plat.
Supporting Materials:
1. Location Map
2. Application
� � J e ,
%
L , 4 r L •
�O� i BOO b0 bN1 � 301 P`' � � N Atil -% \ L %
Ar da %or .4% ,s'
i 4 1
ki O Ar*tt
4P to 4 V ® 0 -r
/ liiiikofitAbL.'_' *IV
N "
-1S-4 �.100 c, I
, ■ oos Q c AT -- ' ° '' 4 I ANT 1 8
,, ,L,. t A # u)
_- -i .:- IA Aor ■,.- _ , A w
-0 4 1 Q
41P'
1.1‘' # Nrt - /- -1
ti cc 4r k ztAfk L11441110 0 W
ko4 :& ,,■■■,4"4744 •V'',,alan i
s t* cA N o -241W4,40 VIVA
i g 2,9 At* #
cr3),= 1 1■41jAri i
A; AIT,71,_,_ ,o u_o
ig 7444,11 z N
.. °G� °G� c °� o°'� F" W
�P �
4 ° P
G� o_� �G 4444
a � . - � Q � pi „ „I��ii � � Z irits, , s,000,,,,0471.4r # ° � -1i s rnW :-crart. o LZ1 N
mii
m — AlitIMA#4._cA � °j � - lF� � d
c#