Loading...
HomeMy WebLinkAboutResponse to Staff Comments Planning & Development Services Arr4 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 CITY OF G01,1 .1 ST• \TION Phone 979.764.3570 / Fax 979.764.3496 Home of Texas Aed7111 Univ i ity" MEMORANDUM March 14, 2011 TO: Joe Grasso, P.E., Doucet & Associates, Inc., via email: joe.grasso cnr doucet- austin.com FROM: Jennifer Prochazka, AICP, Senior Planner SUBJECT: COLLEGE STATION SOUTHWOOD (FP) - Final Plat Staff reviewed the above - mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. If all comments have been addressed and the following information submitted by Monday, March 21, 2011 at 10:00 a.m., your project will be placed on the next available Planning and Zoning Commission meeting scheduled for April 7, 2011 at 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue. X One (1) 24 "x36" copy of the revised final plat; X Thirteen (13) 11"x17" copies of the revised final plat; One (1) copy of the digital file of the final plat on diskette or e-mail to: P &DS_Digital_Submittal @cstx.gov. Upon receipt of the required documents for the Planning & Zoning meeting, your project will be considered formally filed with the City of College Station. Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. If all comments have not been addressed your project will not be scheduled for a Planning & Zoning Commission meeting. Your project may be placed on a future agenda once all the revisions have been made and the appropriate fees paid. Once your item has been scheduled for the P &Z meeting, the agenda and staff report can be accessed at the following web site on Monday the week of the P &Z meeting. http: / /www.cstx.gov /pz Please note that a Mylar original of the revised final plat will be required after P &Z approval and prior to the filing of the plat. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 1 of 4 cc: Walmart Real Estate Business Trust & WaI -Mart TRS, LLC, via email: cgerald.tavlor(c�wal- mart.com Case file #10- 00500265 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2 of 4 STAFF REVIEW COMMENTS NO. 2 Project: COLLEGE STATION SOUTHWOOD (FP) - 10- 00500265 PLANNING 1. Repeat Comment: Please include drawings of both the "Original Plat" and "Replat." The original plat should be shown just as it is on the latest platting document for that portion of the property. There have been several replats /amending plats that affect the property. If you need to go to multiple sheets, please provide an index sheet with a minimum 1"=500' scale. To clarify, the "original plat" should be shown exactly as shown on the latest platting documents (including all easements, etc.). Revised plat is attached. 2. Repeat Comment: Sidewalks are required on all roadways adjacent to the plat. The Planning & Zoning Commission may approve a fee -in -lieu of sidewalks if the owner is interested in making the request. Let me know if you would like more information. To clarify, Sidewalks are required along Texas Avenue, 2818 and Brothers Blvd. Either the sidewalks should be installed, a waiver should be requested, or a request should be made to utilize the Sidewalk Fund, if desired. Attached are two Opinion of Probable Cost (OPC)'s for sidewalks. One for the sidewalk along Texas Avenue and FM 2818. Can we discuss further on the options available for the sidewalks along Texas Avenue and FM 2818? 3. Do you have any further information on the Mechanic's Lien? This is being looked into and information will be provided ASAP. 4. I believe that the large lot (labeled as 4F on the original is really 4A. Please clarify. Addressed. 5. Please include a note on the plat regarding "building plot." The note should state that the Tots included in this plat are considered one building plot for the purposes of signage, landscaping and non - residential architectural standards. Note added. 6. Please note that you may be required to submit paid tax certificates if they are not current prior to the filing of your plat. Noted. Reviewed by: Jennifer Prochazka Date: March 11, 2011 ENGINEERING COMMENTS NO. 2 i J lease submit construction documents for the portion of sidewalk missing along Brother's Blvd adjacent to Lot 3, including the appropriate ramp connections and BCS Construction Details. The sidewalk is required to be a 6 foot wide sidewalk with a inimum 3 foot off -set from the street. Sidewalk plans have been revised. Please submit development permit application fees ($600), as well as engineer's cost estimate and letter of acknowledgement for the sidewalk. Check #34449 was submitted on 3/2/11 and has been cashed by the City of College Station. Cost KT stimate and Letter of Acknowledgment are attached. he sidewalk must be built or a surety for the sidewalk filed with the City before the final plat an be filed for record. Walmart will want to provide a surety prior to plat r ordation. . P lease submit development permit application and fees ($600), as well as engineer's cost estimate and letter of acknowledgement for the sidewalk. Development Permit plication is attached, check will be provided separately. If the intent is to request to use the City's sidewalk fund for the frontage along FM 2818 and Texas Avenue, please provide the documentation for the total amount of frontage NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 3 of 4 along both thoroughfares. The fee is calculated by taking the linear footage of frontage x 6 foot wide sidewalk x $5 /sf. Fee estimate is attached. Reviewed by: Josh Norton Date: March 11, 2011 Please contact Joe Grasso, P.E. at (512) 583 -2636 if you have any questions regarding this submittal or need anything further at this time. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 4 of 4 4.-e" Planning & Development Services 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 CITY or C(/I A ,EGF. ST NT ION Phone 979.764.3570 / Fax 979.764.3496 Home of Texas AdM Universttf MEMORANDUM December 23, 2010 TO: Joe Grasso, P.E., Doucet & Associates, Inc., via email: joe.grasso(a�doucet- austin.com FROM: Jennifer Prochazka, AICP, Senior Planner SUBJECT: COLLEGE STATION SOUTHWOOD (FP) - Final Plat Staff reviewed the above - mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. If all comments have been addressed and the following information submitted by Tuesday, January 4, 2011 at 10:00 a.m., your project will be placed on the next available Planning and Zoning Commission meeting scheduled for January 20, 2011 at 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue. X One (1) 24 "x36" copy of the revised final plat; X Nineteen (19) 11 "x17" copies of the revised final plat;l) One (1) Mylar original of the revised final plat (required after P &Z approval); and One (1) copy of the digital file of the final plat on diskette or e-mail to: P &DS_Digital_Submittal @cstx.gov. Upon receipt of the required documents for the Planning & Zoning meeting, your project will be considered formally filed with the City of College Station. Please note that if all comments have not been addressed your project will not be scheduled for a Planning & Zoning Commission meeting. Your project may be placed on a future agenda once all the revisions have been made and the appropriate fees paid. Once your item has been scheduled for the P &Z meeting, the agenda and staff report can be accessed at the following web site on Monday the week of the P &Z meeting. http://www.cstx.gov/pz Please note that a Mylar original of the revised final plat will be required after P &Z approval and prior to the filing of the plat. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments cc: Walmart Real Estate Business Trust & Wal -Mart TRS, LLC, via email: gerald.taylor @wal- mart.com Case file #10- 00500265 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 1 of 3 STAFF REVIEW COMMENTS NO. 1 Project: COLLEGE STATION SOUTHWOOD (FP) - 10- 00500265 PLANNING 1. The title of the plat should be "Final Plat of College Station Southwood Subdivision, being 3 lots on XX acres, and including a replat of Lot X, Block X of the Southwood Plaza Subdivision Phase I and Lot X, Block X of the Southwood Plaza Subdivision Phase 2." Done. 2. Please include drawings of both the "Original Plat" and "Replat." The original plat should be shown just as it is on the latest platting document for that portion of the property. There have been several replats /amending plats that affect the property. If you need to go to multiple sheets, please provide an index sheet with a minimum 1 " =500' scale. Done. 3. All certificates on the plat should be exactly as shown in the Subdivision Regulations (Unified Development Ordinance Section 8). Please only use the required certificates. Done. 4. Please provide a survey that verifies that no encroachment is being created or legitimized with this plat. See attached "Building Exhibit ". 5. Sidewalks are required on all roadways adjacent to the plat. The Planning & Zoning Commission may approve a fee -in -lieu of sidewalks if the owner is interested in making the request. Let me know if you would like more information. Estimate will be provided via email. 6. What is the status of the "Mechanic's and Materialman's Lien ?" This is being looked into and information will be provided ASAP. 7. Please note that any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that the City has not been made aware of will constitute a completely new review. Noted. 8. Please note that you may be required to submit paid tax certificates if they are not current prior to the filing of your plat. Noted. Reviewed by: Jennifer Prochazka Date: December 15, 2010 ENGINEERING COMMENTS NO. 1 ase provide a 20 foot PUE along the rear lot line of Lot 3. Provided. here appears to be a gap in easement between Lot 3 and the existing sanitary sewer main which will serve this lot. Please provide the appropriate easement in order for Lot 3 to access the existing sanitary sewer main. I believe this stub has already been constructed, so the easement in question needs to cover the stubs location or the property line needs to jog to incorporate this portion of sanitary sewer main. Done. Please submit construction documents for the portion of sidewalk missing along • did ck. Brother's Blvd adjacent to Lot 3. Provided. '))• aPlease submit development permit application and fees ($600), as well as engineer's cost estimate and letter of acknowledgement for the sidewalk. Development Permit application is attached, check will be provided separately. The sidewalk must be built or a surety for the sidewalk filed with the City before the final plat can be filed for record. Noted. Reviewed by: Josh Norton Date: December 22, 2010 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2 of 3 SANITATION 1. Sanitation is ok with this project. Thank you. Reviewed by: Wally Urrutia Date: December 15, 2010 TxDOT Comments 1. No Comment (no additional access, no anticipated impact Noted. Reviewed by: Chad Bohne Date: December 17, 2010 GENERAL ELECTRICAL COMMENTS 1. No comments at this time. Noted. 2. Drawings reflect current conduit routing. 3. To discuss please contact Sam Weido at 979.764.6314. Reviewed by: Sam Weido Date: 12 -16 -10 Please contact Joe Grasso, P.E. at (512) 583 -2636 if you have any questions regarding this submittal or need anything further at this time. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 3 of 3