Loading...
HomeMy WebLinkAbout12-00400004- 00077282 Page 1 of 1 Ms. Walz, Please see our answers below in red along with the attachment. Please let me know if you have any additional questions. Kristen Hejny '08 Staff Assistant Planning & Development Services City of College Station P.O. Box 9960 1101 Texas Avenue College Station, TX 77842 Office: 979.764.3570 Fax: 979.764.3496 City of College Station Home of Texas A &M University »> "Laurie Walz" <lwalz@consultmcclain.com> 1/9/2012 2:04 PM »> Hello, I would like to know for 2301 Earl Rudder Freeway, S: 1. Are there currently any outstanding building code violations on file for the property? No 2. What is the zoning of the property and is it a conforming use? It's zoned C - General Commercial 3. Are there any planned upgrades or retrofits scheduled? There aren't any plans for anv changes that we know of at this time 4. Copies of the Certificate of Occupancy and the original building construction permit. See attached file: / /C: \Documents and Settings \khejny \Local Settings \Temp \XPgrpwise \4F0B1BFECity ... 1/10/2012 City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date 6/28/07 Parcel Number . . . . 004601- 0014 -0041 Property Address . . 2301 EARL RUDDER FWY S COLLEGE STATION TX 77840 Subdivision Name . . . M RECTOR (ICL) Legal Description . . . A004601 M RECTOR (ICL), TRACT 14.41, (IMP ONLY TO TR 14.4 SE E R13183) Property Zoning . . . GENERAL COMMERCIAL Owner CLINE, DAVID Contractor RYAN COMPANIES US, INC 612 492 -4000 Application number . . 06- 00003750 000 000 Description of Work . . COMMERCIAL, STORES & CUSTOMER SERVICE Construction type . . . NON - COMBUSTIBLE Occupancy type . . . MERCANTILE Flood Zone Approved Building Official VOID UNLESS SIGNED BY BUILDING OFFICIAL ttl?)( BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764 -3570 FAX: (979)764 -3496 http: / /bpinspect.cstx.gov Application Number 06- 00003750 Date 1/09/12 Property Address 2301 EARL RUDDER FWY S Tenant nbr, name GANDER MOUNTAIN Application type description COMMERCIAL, STORES & CUSTOMER SERVICE Subdivision Name M RECTOR (ICL) Proppert Use Application valuation . . . 3969000 Owner Contractor CLINE, DAVID RYAN COMPANIES US, INC 2301 SH 6 S 50 SOUTH TENTH STREET, STE 300 COLLEGE STATION TX 77845 MINNEAPOLIS MN 55403 (612) 492 -4000 - -- Structure Information 000 000 NEW RETAIL BUILDING Construction Type NON - COMBUSTIBLE Occupancy Type MERCANTILE Other struct info EXTERIOR WALL TYPE BRICK IMPACT /PRORATA FEES PAID NA FOUNDATION TYPE SLAB HEATED AREA 67849.00 INTERIOR WALL TYPE STEEL STUD SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 285.00 Permit BUILDING PERMIT Additional desc . GS Permit pin number 476986 Permit Fee . . . 8598.00 Issue Date . . . 1/05/07 Valuation . . . . 3969000 Expiration Date . 8/07/07 Qty Unit Charge Per Extension BASE FEE 1660.00 3469.00 2.0000 THOU BLDG, VAL 500001 & UP 6938.00 Special Notes and Comments PROVIDE ADDRESS ON COMMERCIAL BUILDINGS -FRONT 5" NUMBERS REAR - 2" HIGH NUMBERS WITH NAME OF BUSINESS Permit Number provided by the COCS shall be conspicuously S posted in the lower right hand corner of the banner. hall be mounted parallel to the face of a building or permanent structure. Shall advertise only,the name of uses of, or goods or services available within the building or tenant lease space to which the banner is attached. Shall not be located within public road ROW (State or FILE COPY BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764 -3570 FAX: (979)764 -3496 http: / /bpinspect.cstx.gov Page 2 Application Number 06- 00003750 Date 1/09/12 Special Notes and Comments Local) . Shall not obstruct any window, door, stairway, or other opening inteded for ingress or for needed ventilation or light. Shall not exceed the top of the structure to which it is attached. Shall advertise only,the name of uses of, or goods or services available within the building, or tenant lease space, to which the banner is attached. Shall be mounted parallel to the face of the building. Shall not be cantilevered away from the structure. Shall not extend more than one foot from any exterior building face, mansard, awning, or canopy. Shall not obstruct any window, door, stairway, or other opening intended for ingress or for needed ventilation or light. Shall not be attached to any tree, fence, or public utility pole. NOTE FROM WATER DEPT -- REDUCED PRESSURE ASSEMBLY REQUIRED FOR CAR WASH, POSTMIX CARBONATER, AND HEATING /AC WITH DIRECT CONNECTION TO WATER SUPPLY AND LAWN IRRIGATION SYSTEMS. ALL DEVICES MUST BE TESTED UPON INSTALLATION BY CERTIFIED TESTER REGISTERED WITH THE CITY OF COLLEGE STATION PUBLIC UTILITIES DEPT. LAWN IRRIGATION MAY USE A PRESSURE VACCUM BREAKER INSTALLED PER AWWA STANDARDS AND CITY'S ORD #2394. ALL DEVICES MUST BE INSTALLED PER AWWA AND CITY'S ORD #2394 ELETRIC UTILITIES COMMENTS DEVELOPER INSTALLS CONDUIT PER CITY SPECS & DESIGN DEVELOPER PROVIDES TEMP BLANKET EASEMENT FOR CONSTRUCTION DEVELOPER POURS TRANSFORMER PAD PER CITY SPECS (IF NECESSARY) DEVELOPER PROVIDES 30' RIGID CONUDIT FOR RISER POLE (IF NECESSARY) DEVELOPER INSTALLS FIRST 10' OF CONDUIT ON RISER POLE. CITY INSTALLS REMAINING 20'. DEVELOPER PROVIDES EASEMENTS FOR ELECTRIC INFRASTRUCTURE AS INSTALLED FOR ELECTRIC LINES. DEVELOPER PROVIDES DIGITAL SITE PLAN IN AUTOCADE 14 VERSION. EMAIL TO RBOLIN@CI.COLLEGE- STATION.TX.US DEVELOPER IS REPSONSIBLE FOR THE INSTALLATION OF SERVICE FROM TRANSFORMER TO BUILDING FOR QUESTIONS CONTACT RONNIE BOLIN AT 979 - 764 -3614 PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS FILE COPY BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764 -3570 FAX: (979)764 -3496 http: / /bpinspect.cstx.gov Page 3 Application Number 06- 00003750 Date 1/09/12 Special Notes and Comments METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Underground electrical conduit installation shall be installed per city specs and is the responsibility of the owner and /or contractor. Contact the electrical division at (979) 764 -6314 for more information. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR REQUIRED EXIT DOOR(S) SUBMIT FIRE ALARM PLANS WITH PRODUCT DATA SHEETS - DESIGN AND INSTALL AS PER NFPA 72 NO WORK SHALL START UNTIL PLANS HAVE BEEN REVIEWED AND RETURNED PROVIDE FIRE EXTINGUISHER(S) - VERIFY LOCATION AND PLACEMENT WITH THE FIRE MARSHALL'S OFFICE (MIN. 2A1OBC) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND SUBMIT FIRE SPRINKLER PLANS AND CALCULATIONS FOR REVIEW NO WORK ON SPRINKLER SYSTEM SHALL BEGIN UNTIL PLANS HAVE BEEN REVIEW AND RETURNED. SPRINKLER SYSTEM CONTROLS AND WATER FLOW SWITCHES ARE REQUIRED TO BE MONITORED BY AN APPROVED MONITORING COMPANY. A COPY OF THE MONITORING CONTRACT SHALL BE SENT TO THE COLLEGE STATION FIRE DEPARTMENT, FIRE PREVENTION DIVISION. GUARDS SHALL COMPLY WITH SECTION R -312 (2003 IRC) OR SECTION 1012 IN (2003 IBC) AS APPROPRIATE Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROVIDE MINIMUM 42" CLEARANCE FROM CENTER OF WATER CLOSET TO EDGE OF LAVATORY FILE COP BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764 -3570 FAX: (979)764 -3496 http: / /bpinspect.cstx.gov Pa e 4 Application Number 06- 00003750 Date 1/09/12 Special Notes and Comments HANDRAILS SHALL COMPLY WITH SECTION R -311 (2003 IRC) OR SECTION 1009 (2003 IBC) AS APPROPRIATE PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES INTERIOR BEAMS > 60' MUST BE A MINIMUM OF 30" DEEP PROVIDE A KNOX BOX FOR FIRE DEPARTMENT ACCESS. IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY TOOL OR SPECIAL KNOWLEDGE /EFFORT All outdoor lighting must fie in compliance with Section 7.10 Outdoor lighting Standards of the City's Unified Development Ordinance All roof and ground- mounted mechanical equipment shall be sreened from view or isolated so as not to be visible from any public right -of -wa or residential district within 150 feet of the subject lot, measured from a point five feet above grade. Such screening shall be coordinated with the building architecture and scale to maintain a unified appearance. Acceptable methods of screenin rooftop equipment may include, but are not limited to encasement, C parapet walls, or partition screens. OLLEGE STATION ELECTRICAL DIVISION REQUESTS THAT THE METER CAN /ELECTRICAL SERVICE DISCONNECT BE LOCATED ON THE STRUCTURE AS CLOSE AS POSSIBLE TO THE SECONDARY FEEDER CONDUIT FROM THE TRANSFORMER. (see site plan for location of conduit or contact electrical division) CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND 7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA) PROVIDE PANIC HARDWARE ON EXIT DOORS If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE PROJECTIONS (OVERHANGS) BEYOND THE EXTERIOR WALL SHALL COMPLY WITH ORDINANCE NO. 2713 AND CHAPTER 12 AMENDMENTS TO THE U.D.O. AND EXHIBITS "A ", "B ", AND "C ". WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI FILE COPY BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764 -3570 FAX: (979)764 -3496 http: / /bpinspect.cstx.gov Page 5 Application Number 06- 00003750 Date 1/09/12 Special Notes and Comments RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT -OF -WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL PUBLIC SEWER SERVICE IS PROVIDED OR APPROVED ALTERNATE SEWER SYSTEM IS INSTALLED THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 AS PER THE ZONING ORDINANCE SECTION 12.3.L; ATTACHED SIGNS SHALL NOT EXTEND MORE THAN ONE FOOT AWAY FROM EXTERIOR BUILDING FACE REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R -311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. CONSTRUCTION CONTRACTS OVER $50,000 REQUIRE SUBMISSION TO THE STATE FOR ACCESSIBILITY REVIEW - CONTACT TDLR @ (512) 463 -3211 FOR MORE INFORMATION TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK PROVIDE INTERIOR EMERGENCY LIGHTING THROUGHOUT BUILDING, COMPLY WITH SECTION 1006.3 OF THE 2003 IBC. FIRE TREAT ALL WOOD MATERIAL INSTALLED IN THIS BUILDING. Other Fees WATER TAP 2" 3600.00 Fee summary Charged Paid Credited Due Permit Fee Total 8598.00 8598.00 .00 .00 Other Fee Total 3600.00 3600.00 .00 .00 FIL CG BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (9 FAX: (979)764-3496 .gov Page 6 A G p rand a Total Number 12198.00 0612198.000 1/09/12 .00 Date . 0 0 0 0 FILE COPY BUILDING DEPT REPRESENTATIVE: APPLICANT: