HomeMy WebLinkAboutResponse to Staff Comments Schultz Engineering, LLC
Office: 979.764.3900
Fax: 979.764.3910
September 28, 2011
Planning & Development Services
City of College Station
1101 Texas Avenue
College Station, TX 77840
Re: Re -Plat — North Forest Subdivision — Lot 1E -R
The proposed re -plat of Lot 1 E -R is to create 3 lots from this lot. Within this lot, 1
Shared Parking Access Easement will be removed and 1 new Shared Parking Access
Easement will be created by the re -plat. The 3 proposed lots each have existing
public water, sanitary sewer and electrical services in place so no new public utility
easement are proposed.
If you have any questions, please do not hesitate to call.
Very truly yours,
Schultz Engineering, LLC.
1
At II -1 ti `�
Joe Sch f z, P.E.
Civil Engineer
P.O. Box 11995 • College Station, Texas 77842
schultzengineeringllc.com
Schultz Engineering, LLC
Office: 979.764.3900
Fax: 979.764.3910
November 4, 2011
Jason Schubert, AICP
Principal Planner
City of College Station
1101 Texas Avenue
College Station, TX 77840
Re: North Forest Subdivision — Lots 1E-R1 — 1E-R3 Final Plat
Dear Mr. Schubert:
Attached are a mylar copy and an electronic copy of the revised Final Plat of the North Forest
Subdivision, Block 1, Lots 1E -R1 — 1E-R3.
If you have any questions, please do not hesitate to call.
Very truly yours,
Schultz Engineering, LLC.
Atj",
A( 11 t
Joe S • ltz, P.E.
Civil gineer
P.O. Box 11995 • College Station, Texas 77842 6°
1 schultzengineeringllc.com 1/
\ $
•
RESPONSE TO STAFF REVIEW COMMENTS NO. 1
Project: NORTH FOREST L1 -ER (FP- REPLAT) - 11- 00500150
PLANNING
1. Please note that you may be required to submit paid tax certificates if they are not current
prior to the filing of your plat.
Noted.
ENGINEERING COMMENTS NO. 1
1. Lot R1 & R2 do not appear to have access to a public sanitary sewer main. Please
demonstrate /explain how these 2 lots will sewer without additional easement dedication or
extension of public sewer main.
See the attached exhibit for water & sewer services to Lots 1E -R1 & R2.
Lot R1 has an existing water service as shown and 2 sewer services installed with the
original construction. Lot R1 was originally designed for 2 buildings before the
parking lot was expanded is why there are 2 sewer services. The exhibit also shows
the proposed water and sewer services to be extended for Lot R2. If these are not
acceptable, the lot line between R2 and R3 can be moved to put some of the public
waterline and sewer manhole on Lot R2 and the services added with the Site Plan for
those lots.
2. Please demonstrate /explain the location of the water and sanitary sewer services needed to
serve these 2 new lots. If these services are not installed at this time, they will be the
responsibility of the future property owner during the site plan process, in either case it will
likely require the open cutting of the existing parking and drive isles.
See the attached exhibit for water & sewer services to Lots 1E -R1 & R2.
The following changes have also been made to the replat:
• The 10' private drainage easement on the north side of Lot 1D has been extended
across Lot 1 E -R2 to provide drainage for Lot 1 E -R1
The following changes have been made to the plat at the request of the surveyor:
• The distances along the north sides of Lots 1E-R1 — 1E-R3 have been added.
• Ownership information for Lots 1A — 1C have been added.
• The Original Plat and Replat window have been flipped.
• The chord directions for C1 -C3 have been reversed.