HomeMy WebLinkAboutAPPLICATION FOR OFFICE USE NLY
` `•# D . '� . \ l �� P &Z Case No: 0 3
cf3/ Date Submitted: g - )1 - 0 3
COLLEGE STATION
PRELIMINARY PLAT APPLICATION
(check one) ® Preliminary Plat El Master Preliminary Plat
The following items must be submitted by an established filing deadline date for Planning & Zoning
Commission consideration.
MINIMUM SUBMITTAL REQUIREMENTS:
® $400 Application, review, and filing fee.
❑ Variance Request to Subdivision Regulations - $100 (if applicable)
Z Thirteen (13) folded copies of plat. (A revised mylar original must be submitted after staff review.)
® One (1) copy of the approved Master Development Plan or Master Preliminary Plat if applicable.
A copy of the attached checklist with all items checked off or a brief explanation as to why they are not.
❑ Rezoning Application if zone change is proposed.
❑ Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of
approval (if applicable).
NAME OF SUBDIVISION Bentwood Estates - Phase II
SPECIFIED LOCATION OF PROPOSED SUBDIVISION B.B.B. & C.R.R. Survey, A -82 and B. McGreqor
Survey, A -170
APPLICANT /PROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name MLS Development Corporation E -Mail info(victoryhomemortgage.com
Street Address P.O. Box 292
City Wellborn State Texas Zip Code 77881
Phone Number (888) 828 -0895 Fax Number (888) 441 -9604
PROPERTY OWNER'S INFORMATION: (ALL owners must be identified. Please attach an additional sheet
for multiple owners):
Name Same as Above E -Mail
Street Address
City State Zip Code
Phone Number Fax Number
ARCHITECT OR ENGINEER'S INFORMATION:
Name Rick Conlin E -Mail rconlin @txcyber.com
Street Address 3407 Tabor Road
City Bryan State Texas Zip Code 77808
Phone Number (979) 778 -2810 Fax Number (979) 778 -0820
Total'Acres Of Subdivision 126.63 R -O -W Acreage 12.79 Total # Of Lots 48
Number Of Lots By Zoning District 48 / A -O / /
Average Acreage Of Each Residential Lot By Zoning District:
2.366 /A -O / / /
Floodplain Acreage None
Parkland dedication by acreage or fee? NA
A statement addressing any differences between the preliminary plat and approved master development plan
and /or master preliminary plat (if applicable): Realignment of Street to accomidate the current
Thoroughfare plan and adjusted lot boundaries.
Requested variances to subdivision regulations & reason for same None
Requested oversize participation No
Parkland Dedication due prior to filing the Final Plat:
ACREAGE:
NA # of Acres to be dedicated NA # of acres in floodplain
NA # of acres in detention NA # of acres in greenways
OR
FEE IN LIEU OF LAND:
NA # of Single - Family Dwelling Units X $556 = $ NA
NA # of Multi - Family Dwelling Units X $452 = $ NA
NA (date) Approved by Parks & Recreation Board
The applicant has prepared this application and certifies that the facts stated herein and exhibits attached
hereto are true and correct. The undersigned hereby requests approval by the City of College Station of the
above identified plat and attests that all respective owners have been identified on this application.
y7 fc (e � ��� 9 d
S gignature and Title Date
SUBMIT APPLICATION AND THIS
`` LIST CHECKED OFF WITH 13
FOLDED COPIES OF PLAT FOR REVIEW
COLLEGE S1 HON
PRELIMINARY PLAT MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Include the words "PRELIMINARY
PLAT - NOT FOR RECORD" in letters 1/2" high. If more than 1 sheet, an index sheet showing
entire subdivision at a scale of 500 feet per inch or larger.
® 2. Vicinity map which includes enough of surrounding area to show general location of subject
property in relationship to College Station and its City Limits. No scale required but include north
arrow.
® 3. Title Block with the following information:
® Name and address of subdivider, recorded owner, planner, engineer and surveyor.
® Proposed name of subdivision. (Subdivision name & street names will be approved
through Brazos County 911.) (Replats need to retain original subdivision name.)
® Date of preparation. (INCLUDE DATE THE PLAT WAS SUBMITTED AND THE
DATES OF ANY REVISIONS ON THE PLAT)
Z Engineer's scale in feet.
® Total area intended to be developed.
® 4. North Arrow.
® 5. Location of current city limit lines and current zoning district boundary.
Z 6. Subdivision boundary indicated by heavy lines. Boundary must include all of parent tract.
® 7. Descriptions by metes and bounds of the subdivision which shall close within accepted land
survey standards. (Labeled on boundary lines, not separate metes and bounds description.)
® 8. Primary control points or descriptions and ties to such control point, to which , later, all
dimensions, angles, bearings, block numbers, and similar data shall be referred. The plat shall be
located with respect to a comer of the survey or tract, or an original comer of the original survey
of which it is a part.
Z 9. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided
land, and an indication whether or not contiguous properties are platted.
® 10. Location of the 100 Year Floodplain and Floodway, if applicable, according to the most recent
available data.
® 11. Topographic information, including contours at two foot (2 ft.) intervals, wooded areas, and
flowline elevation of streams.
® 12. Proposed land uses (In compliance with Land Use Plan).
• 93. Proposed zoning changes, if any, submit formal rezoning request.
• 14. The location and description with accurate dimensions, bearings or deflection angles and radii,
area, center angle, degree of curvature, tangent distance and length of all curves for all of the
following: (Show existing items that are intersecting or contiguous with the boundary of or
forming a boundary with the subdivision, as well as, those within the subdivision).
Existing Proposed
® Streets. Continuous or end in a cul -de -sac, stubbed out streets must end into a temp.
turn around unless they are shorter than 100 feet.
Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s
sufficient to meet Thoroughfare Plan.)
❑ Z Street offsets and /or intersection angles meet ordinance.
❑ ❑ Alleys.
❑ ❑ Reserve tracts.
❑ ❑ Well site locations.
Z ❑ Pipelines. If carrying flammable gas or fuel, also show size of line, design pressure and
product transported through the line.
® ® Utility Services. (Water & Sanitary Sewer) All existing and proposed utilities of sufficient
size /depth to meet the utility master plan and any future growth areas.
® ® Easements.
® ® Drainage Structures and improvements including underground storm sewer and all
overland systems (flow line of existing watercourses) and showing where these will
discharge. Proposed channel cross sections, if any.
® A number or letter to identify each lot or site and each block.
❑ ❑ Greenbelt area /park linkages /parkland dedication ( All proposed dedications must be
reviewed by the Parks and Recreation Board prior to P & Z Commission
consideration.)
❑ ❑ Public areas
❑ ❑ Other public improvements, including but not limited to parks, schools and other public
facilities
® 15. Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and
infrastructure costs should be distributed evenly throughout the subdivision..
® 16. Are there impact fees associated with this development? ❑ Yes Z No
® 17. If requesting oversize participation items, are the necessary impact studies included?
❑Yes
❑No
ZN /A
k Std 4 / 07 FOR OFFICE USE ONLY
P8Z Case No: 0 3 -(28
Date Submitted j 1' 6
COLLEGE STATION
PRELIMINARY PLAT APPLICATION
(check one) ® Preliminary Plat ❑ Master Preliminary Plat
The following items must be submitted by an established filing deadline date for Planning & Zoning
Commission consideration.
MINIMUM SUBMITTAL REQUIREMENTS:
® $400 Application, review, and filing fee.
❑ Variance Request to Subdivision Regulations - $100 (if applicable)
® Thirteen (13) folded copies of plat. (A revised mylar original must be submitted after staff review.)
® One (1) copy of the approved Master Development Plan or Master Preliminary Plat if applicable.
® A copy of the attached checklist with all items checked off or a brief explanation as to why they are not.
❑ Rezoning Application if zone change is proposed.
❑ Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of
approval (if applicable).
NAME OF SUBDIVISION Bentwood Estates - Phase II
SPECIFIED LOCATION OF PROPOSED SUBDIVISION B.B.B. & C.R.R. Survey, A-82 and B. McGregor
Survey, A -170
APPLICANT /PROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name MLS Development Corporation E -Mail infona victoryhomemortgage.com
Street Address P.O. Box 292
City Wellborn State Texas Zip Code 77881
Phone Number (888) 828 -0895 Fax Number (888) 441 -9604
PROPERTY OWNER'S INFORMATION: (ALL owners must be identified. Please attach an additional sheet
for multiple owners):
Name Same as Above E -Mail
Street Address
City State Zip Code
Phone Number Fax Number
ARCHITECT OR ENGINEER'S INFORMATION:
Name Rick Conlin E -Mail rconlin.txcyber.com
Street Address 3407 Tabor Road
City Bryan State Texas Zip Code 77808
Phone Number (979) 778 -2810 Fax Number (979) 778 -0820
Total Acres Of Subdivision 126.63 R -O -W Acreage 12.79 Total # Of Lots 48
Number Of Lots By Zoning District 48 / A -O / /
Average Acreage Of Each Residential Lot By Zoning District:
2.366 /A -O / / /
Floodplain Acreage None
Parkland dedication by acreage or fee? NA
A statement addressing any differences between the preliminary plat and approved master development plan
and /or master preliminary plat (if applicable): Realignment of Street to accomidate the current
Thoroughfare plan and adjusted lot boundaries. —2600' cul- de-sac street (Ripple Wood Ct.). Water
features and adjacent properties preclude tie-in of
Requested variances to subdivision regulations & reason for same cul -de -sac. The number of dwelling units along the
Requested oversize participation No cul- de-sac is 14 which is significantly less than the
permitted maximum of 30.
Parkland Dedication due prior to filing the Final Plat:
ACREAGE:
NA # of Acres to be dedicated NA # of acres in floodplain
NA # of acres in detention NA # of acres in greenways
OR
FEE IN LIEU OF LAND:
NA # of Single - Family Dwelling Units X $556 = $ NA
NA # of Multi - Family Dwelling Units X $452 = $ NA
NA (date) Approved by Parks & Recreation Board
The applicant has prepared this application and certifies that the facts stated herein and exhibits attached
hereto are true and correct. The undersigned hereby requests approval by the City of College Station of the
above identified plat and attests that all respective owners have been identified on this application.
9 a
S gn� and Title Date
SUBMIT APPLICATION AND THIS
LIST CHECKED OFF WITH 13
FOLDED COPIES OF PLAT FOR REVIEW
COLLEGE STATION
PRELIMINARY PLAT MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
® 1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Include the words "PRELIMINARY
PLAT - NOT FOR RECORD" in letters 1/2" high. If more than 1 sheet, an index sheet showing
entire subdivision at a scale of 500 feet per inch or larger.
® 2. Vicinity map which includes enough of surrounding area to show general location of subject
property in relationship to College Station and its City Limits. No scale required but include north
arrow.
® 3. Title Block with the following information:
Z Name and address of subdivider, recorded owner, planner, engineer and surveyor.
® Proposed name of subdivision. (Subdivision name & street names will be approved
through Brazos County 911.) (Replats need to retain original subdivision name.)
® Date of preparation. (INCLUDE DATE THE PLAT WAS SUBMITTED AND THE
DATES OF ANY REVISIONS ON THE PLAT)
•
Z Engineer's scale in feet.
Z Total area intended to be developed.
Z 4. North Arrow.
® 5. Location of current city limit lines and current zoning district boundary.
Z 6. Subdivision boundary indicated by heavy lines. Boundary must include all of parent tract.
• 7. Descriptions by metes and bounds of the subdivision which shall close within accepted land
survey standards. (Labeled on boundary lines, not separate metes and bounds description.)
® 8. Primary control points or descriptions and ties to such control point, to which , later, all
dimensions, angles, bearings, block numbers, and similar data shall be referred. The plat shall be
located with respect to a comer of the survey or tract, or an original comer of the original survey
of which it is a part.
® 9. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided
land, and an indication whether or not contiguous properties are platted.
® 10. Location of the 100 Year Floodplain and Floodway, if applicable, according to the most recent
available data.
® 11. Topographic information, including contours at two foot (2 ft.) intervals, wooded areas, and
flowline elevation of streams.
El 12. Proposed land uses (In compliance with Land Use Plan).
• 13. Proposed zoning changes, if any, submit formal rezoning request.
® 14. The location and description with accurate dimensions, bearings or deflection angles and radii,
area, center angle, degree of curvature, tangent distance and length of all curves for all of the
following: (Show existing items that are intersecting or contiguous with the boundary of or
forming a boundary with the subdivision, as well as, those within the subdivision).
Existing Proposed
® Streets. Continuous or end in a cul -de -sac, stubbed out streets must end into a temp.
tum around unless they are shorter than 100 feet.
® Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s
sufficient to meet Thoroughfare Plan.)
❑ ® Street offsets and /or intersection angles meet ordinance.
❑ ❑ Alleys.
❑ ❑ Reserve tracts.
❑ ❑ Well site locations.
® ❑ Pipelines. If carrying flammable gas or fuel, also show size of line, design pressure and
product transported through the line.
® ® Utility Services. (Water & Sanitary Sewer) All existing and proposed utilities of sufficient
size /depth to meet the utility master plan and any future growth areas.
• ® Easements.
• Z Drainage Structures and improvements including underground storm sewer and all
overland systems (flow line of existing watercourses) and showing where these will
discharge. Proposed channel cross sections, if any.
® ® A number or letter to identify each lot or site and each block.
❑ ❑ Greenbelt area /park linkages /parkland dedication ( All proposed dedications must be
reviewed by the Parks and Recreation Board prior to P & Z Commission
consideration.)
❑ ❑ Public areas
❑ ❑ Other public improvements, including but not limited to parks, schools and other public
facilities
® 15. Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and
infrastructure costs should be distributed evenly throughout the subdivision..
® 16. Are there impact fees associated with this development? ❑ Yes ® No
® 17. If requesting oversize participation items, are the necessary impact studies included?
❑Yes
❑No
®N /A