HomeMy WebLinkAboutRES2008-00299 3916 TOURNAY LN BUILDING PERMITWFl002127 / 001 City of College Station
. -
PAGE 1
REQ. DATE: 02/05/08 02/05/08 10:58:07
LOCATION: 3916 TOURNAY LN LOC ID: 210808
REQUESTOR: MAGRUDER HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 02/05/08 SCHED COMPLETION: 02/05/08
********************************************************************************
JOB ORDER RESULT COMUMTS
PREPARED 5/07/08,
8:02:30
INSPECTION TICKET
PAGE 5
City of
------------------------------------------------------------------------------------------------
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 5/07/08
ADDRESS
. : 3916 TOURNAY LN
SUBDIV: EDELWEISS GARTENS
10
CONTRACTOR MAGRUDER HOMES, LLC PHONE (979) 324-6682
OWNER
. .
PHONE -
PARCEL
. . 244030-1018-0090
APPL NUMBER: 08-00000299 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
2/13/08
OC
BLDG, FOUNDATION -SLAB TIME: 17:00
2/14/08
AP
February 13, 2008 3:50:01 PM acarter.
Please call John @ 324-6682 before you go out.
Thanks!
Strings On Setbacks O.K.
Slab Ground Installed
B115 01
3/12/08
BB
BLDG, FRAMING TIME: 17:00
3/12/08
AE
March 12, 2008 11:27:15 AM glsouth.
03/12/2008 04:18 PM BB PDA
Need joist hangers in front right and back left
bedrooms.
Seal holes in Tyvek.
B130 01
3/14/08
BB
BLDG, INSULATION TIME: 17:00
3/14/08
AE
March 13, 2008 3:13:12 PM kwolfe.
03/14/2008 11:45 AM BB PDA
Tape seal penetrations in Tyvek.
B125 01
5/06/08
BI
BLDG, FINAL TIME: 17:00
5/06/08
CA
May 6, 2008 8:16:49 AM bcaldwell.
May 6, 2008 10:27:36 AM bcaldwell.
B125 02
5/07/08
BI
BLDG, FINAL TIME: 17:00
AP'gg
May 6, 2008 4:54:53 PM bcaldwell.
-------------------------------------- COMMENTS AND NOTES --------------------------------------
f 3�
Date: 5/7/2008
Inspection Comments for Final
Permit Year: 8 'ermit Number: 29E
Address: 3916 TOURNAY LN
Insp,
Inspection Type Code Description
siat�s
Inspection Result Comments
B100
BLDG, FOUNDATION -SLR
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION-SLi
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
03/12/2008 04:18 PM BB PDA
B115
BLDG, FRAMING
IC
Need joist hangers in front right and back left bedrooms.
B115
BLDG, FRAMING
IC
Seal holes in Tyvek.
B125
BLDG, FINAL
IC
May 6, 2008 10:27:36 AM bcaldwell.
B130
BLDG, INSULATION
IC
03/14/2008 11:45 AM BB PDA
B130
BLDG, INSULATION
IC
Tape seal penetrations in Tyvek.
M100
MECH, ROUGH IN
IC
03/11/2008 11:54 AM BB PDA
M100
MECH, ROUGH IN
IC
Fix duct in master bath. A/C vent needs min. 3 foot
M100
MECH, ROUGH IN
IC
clearance from smoke detectors by framing.
M110
MECH, FINAL
IC
05/06/2008 12:17 PM BB PDA
M110
MECH, FINAL
IC
Need to vent, vent hood completely out of attic. Need walk
M110
MECH, FINAL
IC
way to equipment, in attic. Both by final.
P100
PLBG, ROUGH IN
IC
February 11, 20084:52:05 PM kwolfe.
P125
PLBG, FINAL
IC
04/30/2008 10:52 AM RH PDA
P125
PLBG, FINAL
IC
Need complete walkway for w/h by building final.
Page 1
n
ACE PEST CONTROL
T.P.C.L. # 7120 PT
PO BOX 4474
BRYAN, TX 77805
(979) 823-7777
(979) 774-4736
CERTIFICATE
The following property 3916 TOURNAY
built by
MAGRUDER HOMES LLC State of Texas
County of BRAZOS the city of COLLEGE STATION
Mailing Address SAME Zip code 77845
was treated for subterranean termites on this day FEBRUARY 12, 2008 and has met
with approval. Cost of initial treatment, $313.19, is payable upon completion of work.
The treatment is guaranteed for 12 months from the date of treatment. Thereafter, this
contract is subject to annual renewal (OPTIONAL) upon payment of annual inspection
and renewal fee of $ 125 plus tax, for a period ofr�+e�• ( see attached letter ) If
at any time during this contract a reinfestation of subterranean termites should occur, the
above said property will be treated at no additional cost to the owner. ACE PEST
CONTROL does not accept any liability for any subterranean termite damage repair.
Failure to pay the annual renewal fee within thirty days after the inspection date shall be
construed as a cancellation of this contract. Any alteration or addition to the foundation
of the above described property without proper termite treatment by ACE PEST
CONTROL Services shall nullify this contract.
Licensed and Regulated by the
Texas Department of Agriculture,
Structural Pest Control Service,
PO Box 12847, Austin, Texas 78711-2847
(512)305-8250
Tournay Dr.
c
Site Plan I " = 10'
QQj
►R
Designs That Work!
Dave and Teresa Wheaton
4031 Austin's Landing ph. 919-220-0857
e 10
:: _ Bryan, TX 11808 fax. 9'T9-�18-3199
d g ,jqq
7, Z�,--
'a
BUILDING PERMIT
/ CITY OF COLLEGE STATION -�
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 08-00000299 Date 2/05/08
Application pin number . . . 717366
Property Address . . . . . . 3916 TOURNAY LN
Property ID: 244030-1018-0090
R ## .
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . EDELWEISS GARTENS 10
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 113586
Owner
------------------------
Contractor
------------------------
MAGRUDER HOMES,
LLC
P.O. BOX 10572
COLLEGE STATION
TX 77842
(979) 324-6682
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1721.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
----------------------------------------------------------------------------
TRAFFIC IMPACT ANAL (TAZ)
405.00
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
AC
Permit pin number .
549691
Permit Fee . . . .
502.00 Plan Check Fee
.00
Issue Date . . . .
2/05/08 Valuation . .
. . 113586
Expiration Date . .
8/03/08
Qty Unit Charge
Per
Extension
BASE FEE
460.00
14.00 3.0000
----------------------------------------------------------------------------
THOU BLDG, VAL 100001-500000
42.00
Special Notes and Comments
-Make sure to have 20'
Driveway length from property
line on
side entry garage.
--------------------------------- ----- --
BUILDING DEPT REPRESENTATIVE:
---'-----------
-�r
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 08-00000299
Application pin number . . . 717366
Page 2
Date 2/05/08
Special Notes and Comments
-Narrow Wall Framing Fully Sheathed with 18" Minimum APA
Dining Room Window Area Framing.
*ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
*PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
*PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
*PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
*Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
*DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY
SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE
CORNER OF A STREET INTERSECTION. THIS MEASUREMENT
SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES
AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN
THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION.
*ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
*ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
*MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
*Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
*ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -1` •- -}J - - - - - - - -
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 08-00000299 Date 2/05/08
Application pin number . . . 717366
----------------------------------------------------------------------------
Special Notes and Comments
RESIDENTIAL CODE
*PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
*ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
*Assure Proper GFI Locations, Including One Within 25, Of
Outside A/C Unit
*Wall and Ceiling Insulation are as follows respectively.
If Wall to Window Ratio is up to 15% the Values Shall be
R-13 and R-30, above 15% the Ceiling Insulation is Increased
to R-38.
*ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED
IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
*IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
*REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
*A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
*THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
*ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
*MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
*If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
-------------------------------------------- !01-------a --- &-- 'd-----------
r BUILDING DEPT REP-R.E.SENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 08-00000299
Application pin number . . . 717366
Page 4
Date 2/05/08
Special Notes and Comments
*RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
*For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
*PROVIDE SANITARY FACILITIES
FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
*SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
*PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
*SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
*THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL
TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND
ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET.
*ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
*SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
*REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
*WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
*TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
*AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
*PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC )
*U-Factor Ratings for Window % up to 15% is .65, from 15% to
------------------------------— ------ --- --�-
BUILDING DEPT REPRESENTATIVE- - - - - - --------- : ._
APPLICANT:
---- - - - - - -
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page
5
Application Number . . . . .
08-00000299
Date
2/05/08
Application pin number . . .
717366
----------------------------------------------------------------------------
Special Notes and Comments
20% is .55, from 20% to 25% is
.54 and above 25%
is .46 or
lower.
*RANGE/DRYER DUCT MUST COMPLY
WITH 2O06 IMC
*ALL PLUMBING, ELECTRICAL, AND
HVAC (mechanical)
WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT
BUILDING
DEPARTMENT FOR INSPECTIONS
PRIOR TO COVERING
ANY WORK
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged
---------------------------
Paid Credited
--------------------
Due
----------
Permit Fee Total 502.00
502.00
.00
.00
Plan Check Total .00
.00
.00
.00
Other Fee Total 750.00
750.00
.00
.00
Grand Total 1252.00
1252.00
.00
.00
---------------------------------------------
BUILDING DEPT REPRESENTATIVE: I"--!:o
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
08-00000300
850200
3916 TOURNAY LN
244030-1018-0090
Date 2/05/08
TEMP POLE
EDELWEISS GARTENS 10
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Owner
------------------------
Contractor
------------------------
MAGRUDER HOMES, LLC
P.O. BOX 10572
COLLEGE STATION
TX 77842
(979) 324-6682
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. AC
Permit pin number
. 549709
Permit Fee . . .
. 20.00
Issue Date . . .
. 2/05/08
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
Paid Credited
Due
Permit Fee Total
----------
20.00
------------------------------
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
---------------------------------------------
4 ---- -,6-------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
y� Fa^Of(ficce Use Only
APPLICATION FOR BUILDING PERMIT DATE `!i`VO TRCC REG
CITY OF COLLEGE STATION
t* Rr 1101 TEXAS AVENUE APPLICATION # 6[�
COLLEGE STATION, TX 77840 TEMP POLE #
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning 6 Development Service
WW'W^.CSTX.GOV
ADDRESS/LOCATION: 3CIU W '7�t
LOT �/ BLOCK r g / SUBDIVISION �%S!-Z i_vg7 S SEC/PH % a
BUSINESS/OWNER NAME: �/C�-C %L(,� � 72 / ��-S PHONE:('0/ �- II J 3L �l - G L �l
CONTRACTOR/HOMEOWNER: J;.f-� e
PHONE:
CONTACT PERSON FOR REVIEW COMMENTS: �"a/� 4 1 � /Ztl17ei�HONE: �S �- S 3Z 4 '-la L V2—
FAX: �1Z% ) L 9 0 T 2 L QS
ELECTRICIAN: /3 t %3
HVAC:�I-2i�.�2's
EMAIL:
PLUMBER: �C-o ry�eZ�L
GOOD CENTS (Residential only):
ACCESSORY/STORAGE MOVING RE -ROOF
ADDITION NEW CONSTRUCTION` SHELL ONLY
DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL
LOCATION REMODEURENOVATION` TENTS
DESCRIPTION OF WORK: A4-W % �/C��llJ7/i�L C-,t/S 71ZIf C7/0ter/
PROPOSED USE: / �SI Dd�l7l N—L l -
STRUCTURE USE: S / i� J-;.j?,1�p—Z
HOMEOWNER ASS CIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIB ITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ // 3 , -rb , I �/ TOTAL AREA: L / HEATED AREA:
(Cost of abor and Materials)
501- VUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
SEWER TAP:
t/
ATER TAP:
SIZE
❑ OTHER TAP.
SIZE
TEMP POLE
SIZE
GARAGE TYPE:
SINGLE El
'
ATTACHED
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE EV"TRIPLE
DETACHED � CARPORT
3
Z
S��2o Cie_
SIGNATURE OF APPLICANT: g kc, /1
*If proposed work involves new commerc' construction or ca improvements/renovations to an existing
commercial property, building elevations are required.
............................................................
Official Use Only
�� a-! -0S
Co� Plans Examiner
—aRc.vZLi Acc.eSS
— 10 t bki vle !�-e+ �' A�,d%l
amor
ents: NO
Zoning Official
y J
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
21 Chemical Termiticide Treatment (Soil Treatment)
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
* Verification of Application shall be submitted to the City of College Station
Building Division prior to issuance of the Certificate of Occupancy.
t
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning cr Development Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 8-
DATE:
BUILDING ADDRESS: 3
Dvl2A) a
I. Foundation Requirements- Minimum City Foundation Standa
NA/
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
OK .
II. Framing: Floor, Wall, Ceiling and Roof Requirements
Mail
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
O
E.
Header sizes indicated on plans
N
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
1.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracin if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q.
Tempered Glass required in all hazardous locations
R.
S.
18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
All walls within 3' of property line to have protected openings.
tFOOK
OK
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning dDevelopment Servicet COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
K
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N
K
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
N / K
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
(*f/q"
CITY OF COLLEGE STATION
Planning d Development Services
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NKM
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
AJPjV
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
jgwvlx.�
L XAMINER
DATE