Loading...
HomeMy WebLinkAboutRES2008-00296 236 PASSENDALE LN BUILDING PERMITMay 28 08 11:20a Charles Thomas 979 693-1726 p.2 TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT 1 prQRedy Owner: CHARLES THOMAS HOMES, INC. Location to be Treated: 236 PASSENDAL.E Approximate Measures to be Treated: 2190 Percentage of Termtidde(s) to be applied at this location• 0.06% 73 GAL. Type of Treatment: Full Partial XXyertical-xx HorizontaIlPerimeter Beam_)C Foundation: SLAB Siding• BRICK_ Primary Used RESIDENCE Roof• COMPOSITION A label of Talstar One inse *����� ti 4 hpen attache as Ds'�rt of this document. A LABEL FOR ANY OTHER PESTICIDE RECOMENDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ANY) INCLUDING AREA COVERED, TIME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST. THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE- TREAT FOR TERMRE INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONDITIONS THAT COULD DEVELOP AS A RESULT OF THE OWNER'S ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED. Charges for pre -treat: NOTES: Annual re-newal: SEE ATTACHED SKETCH BUILDERS SUPPLIES SKETCH/ PLAN $308.13 $125.00 32129 PT 2!=< W Cn orTaahincim SPCB liens / =29 PT (5/22/2008) Gina Southerland -'-Re: CAlling for CO ger2t8 Passen'dale Ln Page 1 From: Paul Schoenfeld To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G... Date: 5/12/2008 9:45 AM Subject: Re: CAlling for CO for 236 Passendale Ln ALL OK. PAUL >>> Amber Carter 5/12/2008 8:25 AM >>> by 08-296 Any issues? (3/17/2008) Kim Wolfe - Insulation request inspection result, 236 Passendale, #08-296 Page 1 From: Brian Henry To: Southerland, Gina Date: 3/17/2008 2:46 PM Subject: Insulation request inspection result, 236 Passendale, #08-296 CC: Carter, Amber; Wolfe, Kim Print for file Inspected insulation, 236 Passendale, #08-296, Thomas Homes, 3-17-08 Inspection result: Inspected OK for Good Cents PREPARED 5/09/08, 12:07:44 INSPECTION TICKET PAGE 10 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 5/09/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 236 PASSENDALE LN SUBDIV: EDELWEISS GARTENS PH 7 CONTRACTOR : CHARLES THOMAS HOMES, INC PHONE (979) 696-4384 OWNER . . PHONE PARCEL . . 244030-0719-0070 APPL NUMBER: 08-00000296 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 2/21/08 TB BLDG, FOUNDATION -SLAB TIME: 17:00 2/21/08 AP February 21, 2008 12:06:57 PM glsouth. February 21, 2008 4:49:14 PM kwolfe. strings up, setbacks okay slab ground left side of garage B120 01 2/28/08 RH BLDG, FRAMING -PARTIAL TIME: 17:00 2/28/08 AP February 27, 2008 12:21:39 PM acarter. apa inspection B115 01 3/14/08 RH BLDG, FRAMING TIME: 17:00 3/14/08 AE March 13, 2008 4:32:08 PM glsouth. March 14, 2008 11:49:34 AM kwolfe. need all nail plates for plumbing tape seal all holes through tyvek before foam insulation B130 01 3/17/08 BH BLDG, INSULATION TIME: 17:00 3/17/08 AP March 17, 2008 3:34:46 PM kwolfe. March 17, 2008 3:34:57 PM kwolfe. B125 01 (ZED BI BLDG, FINAL TIME: 17:00 An May 9, 2008 11:49:30 AM ACARTER. 1 -------------------------------------- COMMENTS AND NOTES ----------------------------- r ov U WF1001740 / 001 City of College Station PAGE 1 REQ. DATE: 02/04/08 02/04/08 10:53:34 LOCATION: 236 PASSENDALE LN LOC ID: 208910 REQUESTOR: CHARLES THOMAS ORIGIN: CUSTOMER -WALK IN REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE: SWR 4" WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 02/04/08 SCHED COMPLETION: 02/04/08 ******************************************************************************** JOB ORDER RESULT COMMENTS BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 08-00000296 Date 2/04/08 Application pin number . . . 866976 Property Address . . . . . . 236 PASSENDALE LN Property ID: 244030-0719-0070 R #. Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . EDELWEISS GARTENS PH 7 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 105000 Owner Contractor ------------------------ ------------------------ CHARLES THOMAS HOMES, INC P.O. BOX 10106 COLLEGE STATION TX 77842 (979) 696-4384 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1504.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number . 549170 Permit Fee . . . . 475.00 Plan Check Fee .00 Issue Date . . . . 2/04/08 Valuation . . . . 105000 Expiration Date . . 8/02/08 Qty Unit Charge Per Extension BASE FEE 460.00 5.00 3.0000 THOU BLDG, VAL 100001-500000 15.00 ---------------------------------------------------------------------------- Special Notes and Comments -Add Smoke Detectors -Narrow Wall Bracing Fully Sheathed wi h Interior Anchors ----------------------------------------- BUILDING DEPT/ R-`EPR�SENTATIVE: - -- - ---- ----------- APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 08-00000296 Date 2/04/08 Application pin number . . . 866976 ---------------------------------------------------------------------------- Special Notes and Comments and Bracing to the Left of Front Door Area. Also Modified Living Room Windows to get 32" Minimum OSB at Back Porch. *ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) *PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY *PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. *PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE *Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS *ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET *MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND *Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) *ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE *PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER *ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED *Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit - -------------------------------------------- L ----- ------------ BUILDING DEPT REPI�SSENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Page 3 Application Number . . . . . 08-00000296 Date 2/04/08 Application pin number . . . 866976 ---------------------------------------------------------------------------- Special Notes and Comments *PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES *PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION *Wall and Ceiling Insulation are as follows respectively. If Wall to Window Ratio is up to 1501 the Values Shall be R-13 and R-30, above 150-o the Ceiling Insulation is Increased to R-38. *ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING *IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. *REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT *A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 *THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' *ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP *MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI *RECESSED LIGHTING INSTALLED IN THE BIJILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT R LE;5GE BUILDING DEPT REPRESENTATIVE: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 08-00000296 Date 2/04/08 Application pin number . . . 866976 ---------------------------------------------------------------------------- Special Notes and Comments *For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. *PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. *ADD SMOKE DETECTOR(S) PER NOTES ON PLANS *SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR *PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES *THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET. *ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY *SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS *REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. *WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS *TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS *AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE *U-Factor Ratings for Window % up to 15% is .65, from 15% to 20% is .55, from 20% to 25% is .54 and above 25% is .46 or lower. *RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC *ALL PLUMBING, ELECTRICAL, AND HVAC ( chanic 1) WORK MUST BUILDING DEPT RESENTATIVE: n I I _. APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 08-00000296 Date 2/04/08 Application pin number . . . ---------------------------------------------------------------------------- 866976 Special Notes and Comments BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK *GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged --------------------------- Paid Credited Due ------------------------------ Permit Fee Total 475.00 475.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1225.00 1225.00 .00 .00 ---------------------------------------- - - -- ---- I. -- ----------- BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 08-00000297 021932 236 PASSENDALE LN 244030-0719-0070 Date 2/04/08 TEMP POLE EDELWEISS GARTENS PH 7 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Owner Contractor ------------------------ ------------------------ CHARLES THOMAS HOMES, INC P.O. BOX 10106 COLLEGE STATION TX 77842 (979) 696-4384 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GS Permit pin number . 549188 Permit Fee . . . . 20.00 Issue Date . . . . 2/04/08 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged ---------- Paid Credited ------------------------------ Due Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------------------------------- --- id- ------------------ BUILDING DEPT-,REP ENTATIVE APPLICANT: \Y _ `1)- \ - ( It *Or" CITY OF COLLEGE STATION Planning cd Development Services ADDRESS/LOCATION: APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CSTX.GOV R-A.5szrJJQIE- LOT _J_!�BLOCK __j_,9/SUBDIVISION For OfrV Use Only DATE: APPLICATION # TEMP POLE # BUSINESS/OWNER NAME: CHARLES THOMAS HOMES, INC-PHONE Ku. t3ux 10106 CONTRACTOR/HOMEOWNER: COLLEGE STATION, TX 77842 PHONE CONTACT PERSON FOR REVIEW COMMENTS: r,I,5 FAX: 3 i Z. Le It ELECTRICIAN: �j �t£(_j12-LC_ HVAC: A t"?, C" C M SE PH 07 22°a - fx) -- PHONE: --_�Oo EMAIL: PLUMBER: GOOD CENTS (Residential only): ACCESSORY/STORAGE LOCATION ADDITION MOVING DEMOLITION (Asbestos Survey) NEW CONSTRUCTION DUPLEX (Landscape Plans) REMODEURENOVATION* DESCRIPTION OF WORK: ' V FEW) 40"JE- PROPOSED USE: RE -ROOF SHELL ONLY SLAB ONLY SWIMMING POOL TENT/CANOPY �� HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: �S TEXAS ACCESSIBILITY STANDARD (TAS) PROJ CT REGISTRATION# EABPRJ �� .. VALUATION: $ 1 o 5. 0 DO TOTAL AREA: .,:2 1!30 HEATED AREA: I d (Cost of Labor and Materials) dPUBLIC SEWER SEPTIC/TREATMENT SYS EM d 35� - SEWER TAP: IZE 'S{ E:�Yf/WATER TAP: LL tIZE OTHER TAP: JIZE 10 0 -[�f TEMP POLE GARAGE TYPE: SINGLE ATTACHED d NUMBER OF BEDROOMS NUMBER OF BATHROOMS INTERIOR WALL TYPE: EXTERIOR WALL TYPE FOUNDATION TYPE ROOF TYPE: DOUBLE d TRIPLE ETACHED F__j CARPORT a SIGNATURE OF APPLICANT: K *If proposed work involves new commercial constructlo ade I provements/renovations to an existing commercial property, building elevations are required. 13 Official Use Only t�cfio Plans Examiner t Zoning Official , ,.a �kas ire Marshall ESments: — 1�U 1 � � SZ^.�i¢CJ( �- �'�'�^-� Y S r N O •� 13/L' a"O j 'f0 left 6+ t L*J' Alw("Pa L/vI),C A't GtJy'1'% C A%ef -71. 416 EnqgyCode Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC (Solar Heat Gain Coefficient) Glazing U-Factor R value of ductwork A/C SEER Rating Protection Against Subterranean Termites M Chemical Termiticide Treatment (Soil Treatment) Lk( tST ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other *Verification of Application shall be submitted to the City of College Station Building Department prior to issuance of the Certificate of Occupancy. O N SATE �la�'► 4f.,- Lo� q 19 2-31D Pax���a`E LaNE 3 log s' s P-45,sv4d.alr Lary 6-,,, 51de 1Z.;51-k o p . CHARLES THOMAS HOMES, INC. P.O. BOX 10106 COLLEGE STATION, TX 77842 R34N vr3ok-L Sca\�.; 1� -m-20' PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning & Development Service; COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# 06 ^ a y,6 DATE: BUILDING ADDRESS: 1�3(o eA SS a LAI, I. Foundation Requirements- Minimum City Foundation Standards NA/ ) A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements K A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex K 1. One -hour rated extending to roof deck QK E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. K OK PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& Development Service; COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements A. Stairway Details OK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements NqqLK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NA 1. Electrical fixtures & switches indicated 2. Smoke detector location(s) indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW (*f/"" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning dDevelopment Services COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N K A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements NA(OK) A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/04 Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NAMW Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 NAM Approved subdivision Plat filed Floodplain- Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed OK "APPROVED PLANS PER IRC SECTION R106.3.1." JAC.'a-1.0 J - I -,0B LANS E7,AMINER DATE MECcheck Compliance Report 2000 IECC MECcheck Software Version 3.2 Release lb TITLE: College Station Building Permits CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 01/30/08 DATE OF PLANS: 01/30/2008 PROJECT INFORMATION: 236 Passendale Lane - Edlws Grtns-Phs 7 COMPANY INFORMATION: Charles Thomas Homes, Inc. COMPLIANCE: Passes Maximum UA = 752 Your Home = 515 31.5% Better Than Code Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame, Double Pane with Low-E Door 1: Solid Door 2: Solid Door 3: Glass Slab 1: Unheated, 0.0' insul. Air Conditioner 1: Electric Central Air, 14 SEER Furnace 1: Forced Hot Air, 80 AFUE Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1504 0.0 30.0 47 1696 13.4 0.0 119 167 0.540 90 20 0.130 3 17 0.130 2 17 0.440 7 237 0.0 247 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 000 IECC requireme n MECcheck Version 3.2 Release b. Builder/Designer , Date t CHARLES THOMAS HOMES, INC. P.O. BOX 10106 COLLEGE STATION, TX 77842