HomeMy WebLinkAboutRES2008-00287 5300 CONGRESSIONAL DR BUILDING PERMITPREPARED 7/11/08, 12:07:13 INSPECTION TICKET PAGE 2
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/11/08
------------------------------------------------------------------------------------------------
ADDRESS . : 5300 CONGRESSIONAL DR SUBDIV: PEBBLE CREEK
CONTRACTOR CLAY KOLBY HOMEBUILDING, LLP PHONE (979) 777-9840
OWNER CLAY KOLBY HOMEBUILDING LLP PHONE
PARCEL 497900-0025-0870
APPL NUMBER: 08-00000287 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 02 3/03/08 RH BLDG, FOUNDATION -SLAB TIME: 17:00
3/03/08 AP March 3, 2008 11:36:38 AM acarter.
03/03/2008 05:06 PM RH PDA
strings up, slab ground installed.
B100 01 3/03/08 RH BLDG, FOUNDATION -SLAB TIME: 17:00
3/03/08 DP February 29, 2008 8:59:15 AM acarter.
monday morning please
03/03/2008 11:45 AM RH PDA
Need to wrap all pipes passing through beams. Raise beam
steel up off of pipes. Need water out of beams.
B120 01 4/02/08 OC BLDG, FRAMING -PARTIAL TIME: 17:00
4/02/08 CA April 2, 2008 11:23:14 AM kwolfe.
APA FRAMING
04/02/2008 05:13 PM OC PDA
no apa framework here per prints.
B115'01 4/25/08 OC BLDG, FRAMING TIME: 17:00
4/25/08 AE April 24, 2008 10:00:43 AM acarter.
Window in stairwell needs to be 24 " from any step or
landing by insulation inspection.
B130 01 4/30/08 BH BLDG, INSULATION TIME: 17:00
4/30/08 AP April 30, 2008 2:11:13 PM glsouth.
April 30, 2008 2:11:16 PM glsouth.
B125 01 7/ 1/08 BI BLDG, FINAL TIME: 17:00
7 �`(�O?S � �C July 11, 2008 8:50:17 AM glsouth.
----------------------------------- CONTINUED ONTO NEXT PAGE -----------------------------------
�4. % ? I N
fa/1' ,S I f)S4-';1-1Aj ,
'00000000
"0
#"�
PREPARED 7/11/08, 12:07:13 INSPECTION TICKET PAGE 5
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/11/08
------------------------------------------------------------------------------------------------
ADDRESS . : 5300 CONGRESSIONAL DR SUBDIV: PEBBLE CREEK
CONTRACTOR CLAY KOLBY HOMEBUILDING, LLP PHONE (979) 777-9840
OWNER CLAY KOLBY HOMEBUILDING LLP PHONE
PARCEL 497900-0025-0870
APPL NUMBER: 08-00000287 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: PLBG 00 PLUMBING PERMITS SUB: J B PLUMBING, LLC (979)690-5311
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
P100 01 2/14/08 OC PLBG, ROUGH IN TIME: 17:00
2/14/08 AP February 14, 2008 8:59:44 AM acarter.
P105 01 4/25/08 OC PLBG, TOP OUT TIME: 17:00
4/25/08 AP April 24, 2008 4:55:38 PM bcaldwell.
April 25, 2008 1:33:49 PM acarter.
P125 Ol / PLBG, FINAL TIME:
✓ /,j�J�///� GAS AND SEWER MUST BE COMPLETED.
.
July 11, 2008 10:13:37 AM glsouth.
-------------------------------------- COMMENTS AND NOTES--------------------------------------
PREPARED 7/11/08, 12:07:13 INSPECTION TICKET PAGE 4
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/11/08
------------------------------------------------------------------------------------------------
ADDRESS . : 5300 CONGRESSIONAL DR SUBDIV: PEBBLE CREEK
CONTRACTOR CLAY KOLBY HOMEBUILDING, LLP PHONE (979) 777-9840
OWNER CLAY KOLBY HOMEBUILDING LLP PHONE
PARCEL 497900-0025-0870
APPL NUMBER: 08-00000287 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: MECH 00 MECHANICAL PERMIT SUB: SIEGERT HEATING & A/C (979)776-3750
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
M100 01 4/24/08 OC MECH, ROUGH IN TIME: 17:00
4/24/08 AP April 23, 2008 3:04:39 PM acarter.
M110 01 7/11/08 e MECH, FINAL TIME: 17:00
-0C& July 11, 2008 11:56:21 AM ccourt.
----------------------------------- CONTINUED ONTO NEXT PAGE-----------------------------------
PREPARED
7/11/08, 12:07:13
INSPECTION TICKET PAGE
3
City of
College Station
INSPECTOR: BUILDING INSPECTOR DATE
7/11/08
------------------------------------------------------------------------------------------------
ADDRESS
. : 5300 CONGRESSIONAL DR SUBDIV: PEBBLE CREEK
CONTRACTOR
CLAY KOLBY HOMEBUILDING,
LLP PHONE : (979) 777-9840
OWNER
CLAY KOLBY HOMEBUILDING
LLP PHONE
PARCEL
497900-0025-0870
APPL NUMBER: 08-00000287 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
ELEN 00 NEW ELECTRIC PERMIT SUB: HILLCO ELECTRIC (979)412-5063
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
E110 01
4/23/08 OC
ELEC, ROUGH IN TIME: 17:00
4/23/08 AP
April 23, 2008 9:36:38 AM acarter.
E150 01
7/11/08 B
ELEC, FINAL TIME: 17:00
July 10, 2008 5:00:51 PM ccourt.
{ Vey a,+- 4m
-----------------------------------
CONTINUED ONTO NEXT PAGE -----------------------------------
IVIrs4. Gfx Av5 /11 �rss c 1 /M,//7�_ y-�.�/ w d4,vt-
1 I
a� Glass � Zd
�V ow� d Jf ",j Pe
(4/30/2008) Gina Southerland - Insulation request inspection result Congressional Ct. #08-287 Page 1
From: Brian Henry
To: Southerland, Gina
Date: 4/30/2008 9:25 AM
Subject: Insulation request inspection result Congressional Ct. #08-287
CC: Carter, Amber
Print for File
Inspected insulation, 5300 Congressional Ct. #08-287, Clay Kolby Homes, 4-30-08
Inspection result: Inspected OK for Good Cents
Notes:
Replace insulation in entry at front door by ceiling.
Jul 14 08 06:26p MACIAS 9797744736 p.2
4
Ace Pest Control
PO Box 4474
Bryan TX 77805
Bill To
CLAY KOLBY HOMEBUILDING, INC.
426 TARROW, SUITE 10T
COLLEGE STATION, TX. 77840
Date: July 14, 2008
979-823-7777
TPCL 712OPT
Protess;ona; Services At- An Affomm :e mice
All bills DUE on or before the i ah of the month
fogowing date of service. Service Charge of
1 '/2 % per month (18% per year)
Added to Past Dues Accounts. THIS PORTION IS
FOR YOUR RECORDS. YOUR CHECK IS YOUR
RECIEPT
Service Linear Square Check* Amount
Date Type Of Service ft tt
I .
2/2712008 5300 CONGRESSIONAL SLAB PRETREAT 300 4445 4241 3/7/08
200 GALS SOLUTION BIFENTHRIN ,06
Please return this portion with payment
Remittance Address:
Dale
Amount Due ACE PEST CONTROL -TPCL#7120PT
- — - P.O. BOX 4474
Amount enclosed BRYAN, TX. 77805
CLAY KOLBY HOMEBUILDING, INC.
Thank you for your business
WF1001175 / 001 City of College Station'
PAGE 1
REQ. DATE: 01/31/08 01/31/08 14:28:15
LOCATION: 5300 CONGRESSIONAL DR LOC ID: 195426
REQUESTOR: CLAY KOLBY HOMEBUILDING ORIGIN: CUSTOMER -WALK IN
REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE:
WTR 3/4" SWR 4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 01/31/08 SCHED COMPLETION: 01/31/08
********************************************************************************
JOB ORDER RESULT CON14EPTrS
BUILDING- PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
Owner
CLAY KOLBY HOMEBUILDING LLP
426 TARROW
STE 101
COLLEGE STATION TX 77840
08-00000287 Date 1/31/08
537179
5300 CONGRESSIONAL DR
497900-0025-0870
R112668
RESIDENTIAL, 1 UNIT DETACHED NEW
PEBBLE CREEK
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
375000
Contractor
CLAY KOLBY HOMEBUILDING, LLP
P.O. BOX 8
NAVASOTA TX 77868
(979) 777-9840
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
STONE
IMPACT/PRORATA FEES PAID
N/A
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
3.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
3340.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
4.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TRAFFIC IMPACT ANAL (TAZ)
426.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
AC
Permit pin number .
548768
Permit Fee . . . .
1285.00 Plan Check Fee
.00
Issue Date . . . .
1/31/08 Valuation . .
. . 375000
Expiration Date . .
7/29/08
Qty Unit Charge
Per
Extension
BASE FEE
460.00
275.00 3.0000
THOU BLDG, VAL 100001-500000
825.00
----------------------------------------------------------------------------
Special Notes and Comments
-Add Smoke Detector
Outside Master Bedr om
------------------------------------ ------ --
BUILDING DEPT REPRESENTATIVE:
-- ----------
APPLICANT:
wm
I
25building line
------- -- — — — — — — — —
I
I
I
I
I
I
concrete drive
15'
I �
_ I —
�
I 5 I cal
FOUNDATION I � �
OUTLINE I -
I I
I I
I I I
I I
I
4' wa Ik
I I
I I
I I
- - - - - - - - - - - - - - - - - - -
25 building line
85.00
,5f TE FLAN
Scale : 1/16' = 1'-0'
LOT: 8-1
BLOCK: 25
SECTION: 9-A
FEBBLEGREEK
d)
3
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 08-00000287 Date 1/31/08
Application pin number . . . 537179
----------------------------------------------------------------------------
Special Notes and Comments
-Make Sure 2nd Floor Operable Windows are 24" AFF
-Be Aware of 10' Left Side PUE
-Narrow Wall Bracing Fully Sheathed with 18" Minimum APA on
the outside corners of garage openings and 2nd Floor
Gameroom windows. Also Interior Anchors and Bracing at the
inside Garage Corners.
*ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
*PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
*PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
*Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
*PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
*Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls. -
*DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY
SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE
CORNER OF A STREET INTERSECTION. THIS MEASUREMENT
SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES
AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN
THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION.
*ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
*ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
*MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDAR AS PER CITY'S
-------------------------------------------- ----- --- - -._------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: Cs;z� �L
BUILDING -PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 08-00000287
Application pin number . . . 537179
Page 3
Date 1/31/08
Special Notes and Comments
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
*Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (121, side & 201,
front)
*ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL
RESIDENTIAL CODE
*PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
*ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
*Assure Proper GFI Locations, Including One Within 25, Of
Outside A/C Unit
*PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
*Wall and Ceiling Insulation are as follows respectively.
If Wall to Window Ratio is up to 1501 the Values Shall be
R-13 and R-30, above 15% the Ceiling Insulation is Increased
to R-38.
*ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED
IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
*IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
*REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
*A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
*THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
*ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
*MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
*If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
-------------------------------------------- ------------------
BUILDING DEPT�_ �SEN7ATI E :
APPLICANT:
BUILDING•PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 08-00000287
Application pin number . . . 537179
Page 4
Date 1/31/08
Special Notes and Comments
Also assure proper protection of pipe to U.V. light.
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
*RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
*For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
*PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
*ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
*SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
*PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
*SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
*THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL
TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND
ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET.
*ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
*SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
*REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
*STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
-------------------------------------------- ------- •-----------
BUILDING DEPT REPRESENTAT�V,E:
APPLICANT:
BUILDING,PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page
5
Application Number . . . . . 08-00000287 Date
1/31/08
Application pin number . . . 537179
----------------------------------------------------------------------------
Special Notes and Comments
1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
*WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
*TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
*AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
*PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
*U-Factor Ratings for Window % up to 15% is .65, from 15%
to
20% is .55, from 20% to 25% is .54 and above 25% is .46 or
lower.
*RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
*IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR
FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING
MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE
ROOM.
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited
-- - - - - - - -
Due
- - - - - - ------ - - - - ------ - - - - ------ - - - - ------
Permit Fee Total 1285.00 1285.00 .00
- - - - - -
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 2035.00 2035.00 .00
.00
--------
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #•
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
Owner
CLAY KOLBY HOMEBUILDING LLP
426 TARROW
STE 101
COLLEGE STATION TX 77840
08-00000288 Date 1/31/08
640096
5300 CONGRESSIONAL DR
497900-0025-0870
R112668
TEMP POLE
PEBBLE CREEK
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Contractor
CLAY KOLBY HOMEBUILDING, LLP
P.O. BOX 8
NAVASOTA TX 77868
(979) 777-9840
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. AC
Permit pin number
. 548776
Permit Fee . . .
. 20.00
Issue Date . . .
. 1/31/08
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT
POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid
Credited
Due
Permit Fee Total
20.00
----------
20.00
--------------------
.00
.00
Other Fee Total
45.00
45.00
.00
.00
Grand Total
65.00
65.00
.00
.00
-------------------
BUILDING DE
APPLICANT:
. ` APPLICATION $FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
Cn Y OF COLIXZJ& STA17ON (979) 764 4NO (979) 7644496 FAX
1*""td-DwAr-m rw!3w WWW CSTXGOV
ADOREss/LOCATION: 5 3d0 J
LOT S _�BLOCK ZS—/SUBDIVISION P5;6&,t; C";W / SEwPH —A
BUSINESS/OWNER NAME: OU-( V O tZq �6 iaLgW I LID Pb CG P PHONE: n
CONTRACTOR/HOMEOWNER: PHONE:
CONTACT PERSON FOR REVIEW COMMENTS: r c I PHONE: ( i
FAX: 2 Q 0 ai 6-b EMAIL: C 1��22(c L,_ k 0 I h� , Co #A
�-
ELECTRICIAN: ux O PLUMBER: .j
HVAC: 5(�e66.2T GOOD CENTS (Residential only):
ACCESSORY/STORAGE MOVING RE -ROOF
ADDITION NEW CONSTRUCTION' SHELLONLY
DEMOLITION (ASBESTOS SURVEY) -PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL
LOCATION REMODEL/RENOVATION* TENTS
DESCRIPTION OF WORK: uILL) Aly-O rf41µ4—::
PROPOSED USE: sl��E Fiq' L`r i,wr,-
STRUCTURE USE: 6jAjjQ69 644411(GN f)�
HOMEOWNER ASSOCIATIOWARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL
TEXAS ACCESSIBILITY STANDARD (TAB) PROJECT REGISTRATION# EABPRd
VALUATION:$ 3-2Zolr-D ✓ TOTAL AREA: 1-1411(5— HEATED AREA:
(Cost or Labor oral Materbb)
PUBLIC SEWER
SEP=JTREATMENT SYSTEM
,(!(
SEWER TAP: (�
WATERTAP: (�
❑ OTHER TAP:
TEMP POLE
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMs:
INTERIOR WALL TYPE:
ExTERIOR WALL TYPE:
FOUNDATION TYPE.
ROOF TYPE:
GARAGE TYPE: SINGLE ❑ DOUBLE
ATTACHED DETACHED
SIGNATURE OF APPLICANT:
❑ TRIPLE
❑ CARPORT ❑
`( rz- uw_
*If proposed work involves new comrnerc'ta%or>, ctioll "Cade improvements/renovations to an existing
commercial property, building elevations are re4uifed.
Of mial Um only Comments:
-rg 1-31-08S rNO
AP Plans Examiner
PV
— �l4-WLLi AGc-GS S
— �`� ��6 mV G✓i11o�wJ Z `� �f ��
Zoning Official
— Add s) OI>♦^s o(e Mo skk_ 13,eellgobl.
-- IVV11y Sk Q I Aplr Ipl' Ailu, w oohslje
Cot'$) c_oRvyt.. -4o Lu-c l4evu�%L A wPcS
� 62ar-ei *vL Aries a A44,u b.Q.k�„ (
(Lq ( r, C-e / ? �1�, !9 a M 1 el 19A
Ghw,"au-,_ (VkA �✓�G(Ji«.dam
,A
Energy Code Compliance Information
% Glazing of exterior walls 1
Insulation R value of exterior walls 1?'
Insulation R value of ceiling 1 (flat areas) 3 b
insulation R value of ceiling 2 (vaulted areas/no attic) 11
Glazing SHGC (Solar Heat Gain Coefficient) ,Z
Glazing U-Factor
R value of ductwork
A/C SEER Rating
1
Protection ,against Subterranean Termites
Chemical Termiticide 'Treatment (Soil Treatment)
D Chemical Termiticide Treatment (Field Applied Wood Treatment)
13 Physical Barriers
* Verification of Application sball be submitted to the City of College Station
Building Division prior to issuance of the Certificate of Occupancy.
4 PLAN REVIEW
(*t1q" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning(+ Development Service; COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 05 � 8 7
DATE:
BUILDING ADDRESS: cz
�300 VIC, 4e s s r oK/q,
I. Foundation Requirements- Minimum Ci Foundation Standards
NA/
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
K
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
N
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q.
Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of ro ertline to have rotected o enin s.
OK
0/1
OK
MA
-� PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
planningcdDevelopment Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
N MOK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NAT
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
0
PLAN REVIEW
(*fl"" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning c4Development Servictt COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements - Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations - Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations - Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
A OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
,I , , :L- f - 7 i-or5
wF5-LAT48 1EXAMINER DATE
c
REScheck Compliance Certificate
2000 IECC
REScheck So$ware Version 3.6 Release la
Data filename: C:\Program Files\Check\REScheck\Job 140.rck
PROJECT TITLE: 5300 Congressional
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
WINDOW / WALL RATIO: 0.13
DATE: 01/29/08
DATE OF PLANS: 1/29/2008
PROJECT DESCRIPTION:
Job 140
DESIGNER/CONTRACTOR:
Clay Kolby Homebuilding
COMPLIANCE: Passes
Maximum UA = 1186
Your Home UA = 666
43.8% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.27
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Vinyl Frame:Double Pane with Low-E
SHGC: 0.27
Door 1: Solid
Door 2: Glass
SHGC: 0.30
Furnace 1: Forced Hot Air, 78 AFUE
Air Conditioner 1: Electric Central Air, 14 SEER
Gross
Area or Cavity
Perimeter R-Value
Permit Number
Checked By/Date
Glazing
Cont. or Door
R-ValueU Factor UA
3124 0.0
30.0 97
4523 13.0
0.0 321
540
0.390 211
20
0.300 6
48
0.640 31
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been designed to
meet the 2000 IECC requirements in REScheck Version 3.6 Release la (formerly MECcheck) and to comply with the
mandatory requirements listed in the REScheck Inspection Checklist.
Builder/Designer Date
REScheck Inspection Checklist
2000 IECC
REScheck So$ware Version 3.6 Release la
DATE: 01 /29/08
PROJECT TITLE: 5300 Congressional
Bldg.
Dept.
Use
Ceilings:
1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation
Comments:
Above -Grade Walls:
1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
1. Window 1: Vinyl Frame:Double Pane with Low-E, U-factor: 0.390
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ) No
Comments:
Doors:
1. Door 1: Solid, U-factor. 0.300
Comments:
2. Door 2: Glass, U-factor: 0.640
Comments:
Heating and Cooling Equipment:
1. Furnace 1: Forced Hot Air, 78 AFUE or higher
Make and Model Number
2. Air Conditioner 1: Electric Central Air, 14 SEER or higher
Make and Model Number
Solar Heat- Gain Coefficient:
The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a
3" clearance from insulation.
Materials Identification:
[ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
0
Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R-values, glazing U-fictors, and cooling equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
[ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
[ ] The HVAC system must provide a means 1br balancing air and water systems.
Temperature Controls:
[ ] Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut offthe heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20%
ofthe heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 'F or chilled fluids below 55 T must be insulated to the
levels in Table 2.
6
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non -Circulating Runouts Circulating Mains and Runouts
Temperature (Fl lip to V Up to 1.25" 1.5" to 2.0" Overt
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness
in Inches
by Pipe
Sizes
Piping System Tye
Ranee ( F)
2" Runouts
1" and Less
1.25" to 2"
2 " t "
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)