Loading...
HomeMy WebLinkAboutDEMO2008-00258 1604 ROCK PRAIRIE RD DEMO PERMITDEMOLITION PERMIT CITY OF COLJ,EGE ,STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #- Tenant nbr, name . . . . . . Application type description Subdivision Name . . . Property Use . . . . . Property Zoning . . . . Application valuation . Owner 08-00000258 Date 1/29/08 375574 1604 ROCK PRAIRIE RD 134500-0203-0010 R80075 2ND FLOOR MAIN HOSPITAL DEMOLITION, COMMERCIAL BELMONT PLACE #2 GENERAL COMMERCIAL 180000 COLLEGE STATION HOSPITAL L.P. 01 COLLEGE STATION MEDICAL CTR 1604 ROCK PRAIRIE RD COLLEGE STATION TX 778458345 Contractor KEYS & WALSH CONSTRUCTION, LLC 232 SOUTHWEST PKWY E COLLEGE STATION TX 77840 (979) 693-3200 Structure Information 000 000 Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . **NEEDS TO BE ENTERED** Other struct info . . . . . TRAFFIC IMPACT ANAL (TAZ) 403.00 ---------------------------------------------------------------------------- Permit . . . . . . DEMOLITION PERMIT Additional desc . . AC Permit pin number . 548198 Permit Fee . . . . 25.00 Plan Check Fee .00 Issue Date . . . . 1/29/08 Valuation . . . . 180000 Expiration Date . . 7/27/08 Qty Unit Charge Per Extension BASE FEE 25.00 ---------------------------------------------------------------------------- Special Notes and Comments *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND 7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA) *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. Shall advertise only the name of, uses of, or goods or --------------------------------------------- C ------------------- BUILDING DEPT yp10ENWI14 VE : -A / J // // APPLICANT: DEMOLITION PERMIT CITY OF COI,IrEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 08-00000258 Date 1/29/08 Application pin number . . . 375574 ---------------------------------------------------------------------------- Special Notes and Comments services available within the building or tenant lease space to which the sign is attached; Shall be parallel to the face of the building; Shall not be cantilevered away from the structure; Shall not extend more than one foot from any exterior building face, mansard, awning, or canopy; Shall not obstruct any window, door, stairway, or other opening intended for ingress or for needed ventilation or light; and Shall not be attached to any tree or public utility pole. *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 25.00 25.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 25.00 25.00 .00 .00 --------------------------------------------- I -------------------- --- BUILDING DEPT REPREZENTATIVE: APPLICANT: Fw Otlttr Use Only APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning d Drvdopment Service , WWW.CSTX.GOV ADDRESS/LOCATION: WVo A EQCf`1�t�C8LE DATED • (�TRCC REG APPLICATION # %O "145O�/ TEMP POLE # LOT BLOCK SUBDIVISION / SEC/PH BUSINESS/OWNER NAME: (%[ (t.E/CSa ra Il/(CL C LNi'P2 PHONE: CONTRACTOR/HOMEOWNER: via., PHONE: _ & 3-32iT2 CONTACT PERSON FOR REVIEW COMMENTS: PHONE: 2WS�Ec� FAX: EMAIL: 1 ELECTRICIAN: w(X.t= X_ PLUMBER: r HVAC: GOOD CENTS (Residential only): ACCESSORY/STORAGE MOVING RE -ROOF ADDITION NEW CONSTRUCTION* SHELL ONLY EMOLITION ASBESTOS SURVEY PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL LOCATION REMODEURENOVATION* TENTS DESCRIPTION OF WORK: PROPOSED USE: pti STRUCTURE USE: VoPrfrl:�L HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ l o, QQ TOTAL AREA: /v._V HEATED AREA:3 S� !/ (Cost of Labor and Materials) PUBLIC SEWER SEPTIC/TREATMENT SYSTEM SEWER TAP: IZE ❑ WATER TAP: VT OTHER TAP: SIZE TEMP POLE GARAGE TYPE: SINGLE El ATTACHED NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: \ INTERIOR WALL TYPE:v�w}LC, EXTERIOR WALL TYPE: ctSo/V Pay FOUNDATION TYPE: ffiJ�b� ROOF TYPE: LLLT- Up DOUBLE a TRIPLE a DETAC)iED F-] CARPORT SIGNATURE OF APPLICANT: *If proposed work involves new mercial construction or facade improvements/renovations to an existing commercial property, building evations are required. ........................................................... Official Use Only Comments: )nor N0 Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC (Solar Heat Gain Coefficient) Glazing U-Factor R value of ductwork A/C SEER Rating Protection Against Subterranean Termites ❑ Chemical Termiticide Treatment (Soil Treatment) J ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other * Verification of Application shall be submitted to the City of College Station Building Division prior to issuance of the Certificate of Occupancy. LOFLIN ENVIRONMENTAL SERVICES, INC. January 25, 2008 Keys & Walsh Construction 232 Southwest Parkway College Station, Texas 77840 Attention: Mr. Kenn Walsh Subject: Results of Limited Survey for Asbestos Containing Materials ICU in the Center Building, Second Floor at the College Station Medical Center Located at 1604 Rock Prairie Road in College Station, Texas Loftin Environmental Services, Inc. Project Number 1900801 Dear Mr. Walsh, Loftin Environmental Services, Inc. (LOFLIN) has completed a limited asbestos survey of the second floor ICU in the center building of the College Station Medical Center at 1604 Rock Prairie Road in College Station, Texas. The survey was to identify possible asbestos containing materials used in the space and assess those which may become friable during building renovation. This survey was performed by W. Joseph Loftin (DSHS Consultant #10-5140) on January 23, 2008. The unit was visually inspected to identify suspect asbestos containing materials. Suspect materials identified and sampled included HVAC duct mastic (white), pipe insulation sealant (white), HVAC mastic (green), exhaust ducting tape (white), sheet vinyl flooring, ceiling tile, fireproofing, sink coating and wallboard joint compound. Representative samples of these materials were collected and submitted to LOFLiN's Houston laboratory (NVLAP #2044, DSHS Lab # 30-0031). Samples were analyzed using Polarized Light Microscopy coupled with dispersion staining in accordance with the US EPA "Method for the Determination of Asbestos in Bulk Samples" (EPA 600/R-93/116, July 1993). Based upon laboratory analysis, two of the three samples of HVAC duct mastic (white) were determined to be asbestos containing. This material is non -friable and, if not included in the planned renovation, should not become friable during the renovation activities. This survey was conducted in general accordance with the Texas Asbestos Health Protection Rules (TAHPR) and the National Emission Standards for Hazardous Air Pollutants (NESHAP) for the areas being renovated and/or demolished. Loftin Environmental Services, Inc, appreciates this opportunity to provide these testing services. Should you have any further questions regarding this matter, please do not hesitate to contact us. Sincerely, Loftin En vir ent ervic 1 W. Josep Loftin DSHS Consultant # -5140 DSHS Lab # 30-0031 2020 MONTROSE • HOUSTON, TEXAS 77006 ■ (713)521-3300 • FAX (713)523-0829 ■ www.loflinenvironmental.com i Lof n Environmental Services, Inc. 2020 Montrose Blvd., Houston, Texas 77006 (713) 521-3300 Fax (713)523-0829 LOFLIN NVLAP 10-2044 TDH Lab 30-0031 Report of Bulk Sample Analysis For Asbestos Identification Polarized Light Microscopy (PLM) EPA 600/R-93/116, July 1994 Client: KEYS & WALSH CONSTRUCTION Date Received: 11232007 Client Address: 232 SW PARKWAY, COLLEGE STATION, TX Date Analyzed: 112512007 Project No: 190-08-01 Page 1 of 4 Project Name: 1604 ROCK PRAIRIE RD. 2NO FLOOR, COLLEGE STATION TX Lab Field Sample Sample Asbestos Additional Number Number Description Location Detected Constituents (Components) L 142585 Bf BEIGE, FIBROUS NONE DETECTED 40% CELLULOSE, HOMOGENOUS 40% MINERAL WOOL, (CEILING TILE) PERLITE L 142586 B2 BEIGE, FIBROUS NONE DETECTED 40% CELLULOSE, HOMOGENOUS 40% MINERAL WOOL, (CEILING TILE) PERLITE L 142587 B3 BEIGE, FIBROUS NONE DETECTED 40% CELLULOSE, HOMOGENOUS 40% MINERAL WOOL, (CEILING TILE) PERLITE L 142588' B4 WHITE, GUMMY 24% CHRYSOTILE OTHER HOMOGENOUS (DUCT SEALANT) L 142589 B5 WHITE, GUMMY NONE DETECTED 10% CELLULOSE, OTHER HOMOGENOUS (DUCT SEALANT) L 142590' 86 WHITE, GUMMY 24% CHRYSOTILE OTHER HOMOGENOUS (DUCT SEALANT) L 142591 B7 WHITE, GUMMY NONE DETECTED 10% CELLULOSE, OTHER HOMOGENOUS (PIPE SEALANT) L 142592 88 WHITE, GUMMY NONE DETECTED 10% CELLULOSE, OTHER HOMOGENOUS (PIPE SEALANT) Laboratory Manager Asbestos -containing materials - The type and percentage of various fibrous components was determined by the microscopist in accordance with U.S. Environmental Protection Agency Method For The Determination Of Asbestos In Bulk Samples" EPA/600/R-93/116, July 1993. Departures from the test method: None The above test report must not be used by the client to claim product endorsement by NVLAP or any other agency of the V. S. Government. Analysis results on this test report pertain only to those materials tested. Disclaimers: PLM analysis has been known to be inaccurate for materials with low concentrations of asbestos. Negative PLM results cannot be guaranteed. LES recommends using TEM analysis for materials reported as <i % or none detected, This report may not be reproduced, except in full, without written approval by LES. ' Loftin Environmental Services, Inc. 2020 Montrose Blvd., Houston, Texas 77006 (713) 521-3300 Fax (713)523-0829 L� LOFLIN NVLAP 10-2044 TDH Lab 30-0031 Report of Bulk Sample Analysis For Asbestos Identification Polarized Light Microscopy (PLM) EPA 600/R-931116, July 1994 Client: KEYS & WALSH CONSTRUCTION Date Received: 11232007 Client Address: 232 SW PARKWAY, COLLEGE STATION, TX Date Analyzed: 112512007 Project No: 190-08-01 Page 2 of 4 Pro ect Name: 1604 ROCK PRAIRIE RD. 2"D FLOOR, COLLEGE STATION, TX Lab Field Sample Sample Asbestos Additional Number Number Description Location Detected Constituents (Components) L142593 B9 WHITE, GUMMY NONE DETECTED 10% CELLULOSE, OTHER HOMOGENOUS (PIPE SEALANT) L 142594 B 10 GRA Y, FIBROUS NONE DETECTED 95 % MiNERAL WOOL, HOMOGENOUS OTHER (FIREPROOFING) L 142595 B 11 GRA Y, FIBROUS NONE DETECTED 95 % MINERAL WOOL, HOMOGENOUS OTHER (FIREPROOFING) L142596 B12 GRAY, FIBROUS NONE DETECTED 95% MINERAL WOOL, HOMOGENOUS OTHER (FIREPROOFING) L 142597 B13 WHITE, FIBROUS NONE DETECTED 30% CELLULOSE, CALCITE, HOMOGENOUS VINYL (LINOLEUM) L142598 B14 WHITE, FIBROUS NONE DETECTED 30% CELLULOSE, CALCITE, HOMOGENOUS VINYL (LINOLEUM) L142599 B15 WHITE, FIBROUS NONEDETECTED 30% CELLULOSE, CALCITE, HOMOGENOUS VINYL (LINOLEUM) L 142600 B16 WHITE, POWDERY NONE DETECTED CALCITE, QUARTZ, MICA, HOMOGENOUS OTHER (JOINT COMPOUND) Laboratory M nager 'Asbestos -containing materials - The type and percentage of various fibrous components was determined by the microscopist in accordance with U.S. Environmental Protection Agency "Method For The Determination Of Asbestos In Bulk Samples" EPA/600/R-931116, July 1993. Departures from the test method: None The above test report must not be used by the client to claim product endorsement by NVLAP or any other agency of the U. S. Government. Analysis results on this test reportpertain only to those materials tested. Disclaimers: PLM analysis has been known to be inaocurate for materials with low concentrations of asbestos. Negative PLM results cannot be guaranteed. LES recommends using TEM analysis for materials reported as <1 % or none detected This report may not be reproduced, except in full, without written approval by LES. ' Loftin Envlronmental Services, Inc. 2020 Montrose Blvd., Houston, Texas 77006 (713) 521-3300 Fax (713)523-0829 L.� LOFLIN NVLAP 10-2044 TDH Lab 30-0031 Report of Bulk Sample Analysis For Asbestos Identification Polarized Light Microscopy (PLM) EPA 600/R-93/116, July 1994 Client: KEYS & WALSH CONSTRUCTION Date Received: 11232007 Client Address: 232 SW PARKWAY, COLLEGE STATION, TX Date Analyzed. 112512007 Project No: 190-08-01 Page 3 of 4 Pro ect Name: 1604 ROCK PRAIRIE RD. 2ND FLOOR, COLLEGE STATION, TX Lab Field Sample Sample Asbestos Additional Number Number Description Location Detected Constituents (Components) L142601 816 WHITE, POWDERY NONE DETECTED CALCITE, QUARTZ, MiCA, HOMOGENOUS OTHER (JOINT COMPOUND) L 142602 817 WHITE, POWDERY NONE DETECTED CALCITE QUARTZ, MiCA, HOMOGENOUS OTHER (JOINT COMPOUND) L 142603 618 WHiTE, POWDERY NONE DETECTED CALCITE, QUARTZ, MICA, HOMOGENOUS OTHER (JOINT COMPOUND) L142604 819 GREEN, GUMMY NONE DETECTED OTHER HOMOGENOUS (HVAC MASTIC) L142605 B20 GREEN, GUMMY NONE DETECTED OTHER HOMOGENOUS (HVAC MASTIC) L 142606 821 GREEN, GUMMY NONE DETECTED OTHER HOMOGENOUS (HVAC MASTIC) L142607 822 WHITE, GUMMY NONE DETECTED 10% CELLULOSE, HOMOGENOUS 5% WOLLASTONiTE, (DUCT TAPE SEALANT) AGGREGATE, OTHER L 142608 B23 WHITE, GUMMY NONE DETECTED 10 % CELLULOSE, HOMOGENOUS 5% WOLLASTONiTE (DUCT TAPE SEALANT) AGGREGATE, OTHER La ratory Manager 'Asbestos -containing materials - The type and percentage of various fibrous components was determined by the microscopist in accordance with U.S. Environmental Protection Agency "Method For The Determination Of Asbestos in Bulk Samples" EPA/600/R-93/116, July 1993. Departures from the test method: None The above test report must not be used by the client to claim product endorsement by NVLAP or any other agency of the U. S. Government. Analysis results on this test report pertain only to those materials tested. Disclaimers: PLM analysis has been known to be inaccurate for materials with low concentrations of asbestos. Negative PLM results cannot be guaranteed. LES recommends using TEM analysis for materials reported as <1 % or none detected. This report may not be reproduced, except in full, without written approval by LES. M ' Lofln Environmental Services, Inc. 2020 Montrose Blvd., Houston, Texas 77006 (713) 521-3300 Fax (713)523-0829 LOFLiN NVLAP 10-2044 7DH Lab 30-0031 Report of Bulk Sample Analysis For Asbestos identification Polarized Light Microscopy (PLM) EPA 600/R-93/116, July 1994 Client: KEYS & WALSH CONSTRUCTION Date Received: 11232007 Client Address: 232 SW PARKWAY, COLLEGE STATION, TX Date Analyzed. 1/25&007 Project No: 190-08-01 Page 4 of 4 Project Name: 1604 ROCK PRAIRIE RD. 2N' FLOOR, COLLEGE STATION, TX Lab Field Sample Sample Asbestos Additional Number Number Description Location Detected Constituents (Components) L142609 B24 WHITE, GUMMY NONE DETECTED 10% CELLULOSE, HOMOGENOUS 5% WOLLASTONiTE, (DUCT TAPE SEALANT) AGGREGATE, OTHER L142610 B25 GRAY, CRUMBLY NONE DETECTED 15% CELLULOSE, CALCITE, HOMOGENOUS OTHER (SINK COATING) L142611 B26 GRAY, CRUMBLY NONE DETECTED 15% CELLULOSE, CALCITE, HOMOGENOUS OTHER (SINK COATING) L142612 B27 GRAY, CRUMBLY NONEDETECTED 15% CELLULOSE, CALCITE, HOMOGENOUS OTHER (SINK COATING) L oratory Manager Asbestos -containing materials - The type and percentage of various fibrous components was determined by the microscopist in accordance with U.S. Environmental Protection Agency "Method For The Determination Of Asbestos in Bulk Samples" EPA/600/R-93/116, July 1993. Departures from the test method: None The above test report must not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government. Analysis results on this test report pertain only to those materials tested. Disclaimers: PLM analysis has been known to be inaccurate for materials with low concentrations of asbestos. Negative PLM results cannot be guaranteed. LES recommends using TEM analysis for materials reported as <i % or none detected. This report may not be reproduced, except in full, without written approval by LES.