HomeMy WebLinkAboutRES2008-00224 3319 KEEFER LOOP BUILDING PERMITAmber Carter - Re: CAlling for CO for 3319 Keefer Loop 1
From: Terry Boriskie
To: Amber Carter; Benjamin McCarty; Chris Haver; ...
Date: 4/10/2008 12:00 pm
Subject: Re: CAlling for CO for 3319 Keefer Loop
Contacted Kenny at 587-2275
Terry Boriskie
City of College Station
Residential Plans Examiner
Ofc. 979-764-3744 Fax 979-764-3496
>>> Joe Garcia 4/10/2008 11:47 am >>>
NO FOR CO. SEWER BOX IS BROKEN, AND WILL NEED TO BE REPLACED BEFORE CO IS ISSUED. JMG
>>> Amber Carter 04/10/08 8:17 AM >>>
by 08-224
Any issues?
WF0999968 / 001 City of Coklege.Station PAGE 1
REQ. DATE: 01/28/08 01/28/08 12:59:32
LOCATION: 3319 KEEFER LOOP LOC ID: 207834
REQUESTOR: K M CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE:
SWR 4"
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 01/28/08 SCHED COMPLETION: 01/28/08
********************************************************************************
JOB ORDER RESULT COMIENTS
May 06 08 1132a MACIAS 9797744736 p.4
twa -jp
TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT
Properly Owner: KM CUSTOM HOMES
Location to be Treated: 3319 KEEFER ST. LOOP
Approximate Measures to be Treated: H A 720
Percentage of Termticide(a) toheap In led at th1s1geation= 0..46% Br GAL.
Tyne of Treatment: Full Partial XX Vertical X
Horizontal/Perimeter Beam XX
Foundation: SLAB Siding: BRICK
Primary Use: RESIDENCE Roof: COMPOSITION
A LABEL FOR ANY OTHER PESTICIDE RECOMENDED OR USED HAS BEEN ATTACHEDAS PART OF THIS DOCUMENT WARRANTY INFORMATION (IF ANY)
WCLUDING AREA COVERED. TIME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE-
TREAT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERM ITE GESTATIONS WITH IN THE WARRANTY PERIOD. AND THE CONDITIONS THAT
COULD DEVELOP AS A RESULT OF THE OWNER'S ACTION OR INACTION THAT WOULD VOID THE VMRR/V•ITY HAS ALSO BEEN ATTACHED.
SEE ATTACHED SKETCH
BUILDERS SUPPLIES SKETCH/ PLAN
Charges for pre treat: $297.90
NOTES: Annual re-newal: $120.00
G
Q 3 �,D
32129 PT 1/30/2008
Ca w Twhku*m SPC8 11eeeae0 Srb PT
PREPARED
4/10/08, 8:06:49
INSPECTION TICKET
PAGE 13
City of
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 4/09/08
------------------------------------------------------------------------------------------------
ADDRESS
. : 3319 KEEFER LOOP
SUBDIV: WILLIAMSGATE PH 1
CONTRACTOR
K M CUSTOM HOMES
PHONE (979) 589-3739
OWNER
ROBBIE ROBINSON,
LTD PHONE
PARCEL
660030-0104-0020
APPL NUMBER: 08-00000224 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
2/04/08 RH
BLDG, FOUNDATION -SLAB TIME: 17:00
2/04/08 AP
February 1, 2008 1:49:33 PM kwolfe.
February 4, 2008 9:29:17 AM kwolfe.
B115 01
2/29/08 RH
BLDG, FRAMING TIME: 17:00
2/29/08 DP
February 29, 2008 9:14:53 AM glsouth.
Need apa nailing at garage. Need max 41 wall at
front
bedroom and porch area.
B115 02
3/04/08 TB
BLDG, FRAMING TIME: 17:00
3/04/08 AP
March 4, 2008 3:04:13 PM acarter.
Garage APA Framing redone correctly, Front Door
Area that
did not get moved to 4' of front wall was allowed
to remain
unchanged on this house and will not be allowed
to happen
again per Terry Boriskie.
B130 01
3/05/08 OC
BLDG, INSULATION TIME: 17:00
3/05/08 AP
March 4, 2008 3:04:33 PM acarter.
B125 01
4/09/08 BI
BLDG, FINAL TIME: 17:00
7g
{
April 9, 2008 2:24:37 PM glsouth.
-------------------------------------- COMMENTS AND NOTES --------------------------------------
k10 TaL&7 CI P l-T..0a
Date: 4/10/2008
Inspection Comments for Final
Permit Year: 8 permit Number: 224
Address: 3319 KEEFER LOOP
Insp.
Type
Inspection Type Code
Description
insP
status
Inspection Result Comments
B100
BLDG, FOUNDATION-SL,
IC
February 4, 2008 9:29:17 AM kwolfe.
13115
BLDG, FRAMING
IC
Need apa nailing at garage. Need max 4' wall at front
6115
BLDG, FRAMING
IC
bedroom and porch area.
13115
BLDG, FRAMING
IC
Garage APA Framing redone correctly, Front Door Area
B115
BLDG, FRAMING
IC
did not get moved to 4' of front wall was allowed to remain
13115
BLDG, FRAMING
IC
unchanged on this house and will not be allowed to happen
B115
BLDG, FRAMING
IC
again per Terry Boriskie.
E110
ELEC, ROUGH IN
IC
Need proper meter height at final.
E150
ELEC, FINAL
IC
March 31, 2008 4:41:10 PM kwolfe.
E150
ELEC, FINAL
IC
not ready
E150
ELEC, FINAL
IC
April 2, 2008 12:40:34 PM kwolfe.
E150
ELEC, FINAL
IC
Add dirt for proper meter height of 56" max at center of
E150
ELEC, FINAL
IC
meter and label all breakers in panel by building final.
P105
PLBG, TOP OUT
IC
February 29, 2008 7:59:48 AM kwolfe.
Page 1
BLK-4
LOT-2
0
3119 KEEFER LOOP
SITE PLAN
SCALE: 1"=20'-0"
M
Lo
I
I
BUILDING PERMIT
CITY OF'COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
08-00000224 Date 1/28/08
424192
3319 KEEFER LOOP
660030-0104-0020
R304778
RESIDENTIAL, 1 UNIT DETACHED NEW
WILLIAMSGATE PH 1
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
113520
Owner Contractor
ROBBIE ROBINSON, LTD
K M CUSTOM HOMES
3800 SH-6 S
232 SOUTHWEST PKWY
E
STE 104
COLLEGE STATION
TX 77840
COLLEGE STATION
TX 778455840 (979) 589-3739
--- Structure Information 000 000 SINGLE FAMILY
Construction Type .
. . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . .
. . . . RESIDENTIAL-SFR/DUPLEX
Other struct info .
. . . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
DUE
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET) -ATT
HEATED AREA
1720.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TRAFFIC IMPACT ANAL (TAZ)
406.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
AC
Permit pin number .
547794
Permit Fee . . . .
502.00 Plan Check Fee
.00
Issue Date . . . .
1/28/08 Valuation . . .
. 113520
Expiration Date . .
7/26/08
Qty Unit Charge Per Extension
BASE FEE 460.00
14.00 3.0000 THOU BLDG, VAL 100001-500000 42.00
----------------------------------------------------------------------------
Special Notes and Comments
-Add Smoke Detectors inside and outsid Bedroom #4
-
-------------------- --
-- ----------------------=�--- --=---.------------
BUILDING DEPT R
APPLICANT:
BUILDING PERMIT
CITY OF'COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 08-00000224
Application pin number . . . 424192
Page 2
Date 1/28/08
Special Notes and Comments
-Narrow Wall Bracing Fully Sheathed with 16" Minimum APA
Garage Framing and Make sure Front Door is Max. 4' Offset
*ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
*PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
*PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
*PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
*Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
*ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
*ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
*MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
*Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
*ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL
RESIDENTIAL CODE
*PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
*ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
*Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
--------------- - -- --------- - -ii
--------- ------ --- ----- -------BUILDING DEPT E SIVE:
v- y
APPLICANT:
BUILDING PERMIT
CITY OF'COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 08-00000224
Application pin number . . . 424192
Page 3
Date 1/28/08
Special Notes and Comments
*PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
*PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
*Wall and Ceiling Insulation are as follows respectively.
If Wall to Window Ratio is up to 15% the Values Shall be
R-13 and R-30, above 15% the Ceiling Insulation is Increased
to R-38.
*ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED
IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
*IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
*REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
*A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
*THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
*ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
*MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
*If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
*RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Ir
-------------------------------------------- ------ ---- -----:-----------
BUILDING DEPT -'ePRf SE `IA JIVE : .
APPLICANT:
BUILDING PERMIT
CITY OF -COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 4
Application Number . . . . . 08-00000224 Date 1/28/08
Application pin number . . . 424192
----------------------------------------------------------------------------
Special Notes and Comments
*For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
*PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
*ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
*SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
*PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
*SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
*THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL
TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND
ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET.
*ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
*SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
*REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
*WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
*TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
*AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
*PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
*U-Factor Ratings for Window % up to 15% is .65, from 15% to
20% is .55, from 20% to 25% is .54 and ove 25% is .46 or
-------------------------------- ----------------�----- -- -- ------------
BUILDING DEPT F f R�SE T�) I `'1.
APPLICANT:
BUILDING PERMIT
CITY OF•COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page
5
Application Number . . . . .
08-00000224 Date
1/28/08
Application pin number . . .
----------------------------------------------------------------------------
424192
Special Notes and Comments
lower.
*RANGE/DRYER DUCT MUST COMPLY
WITH 2O06 IMC
*ALL PLUMBING, ELECTRICAL, AND
HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS
PRIOR TO COVERING ANY WORK
*GAS APPLIANCES HAVING AN IGNITION
SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE
IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES
BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
SEWER TAP 4"
350.00
----------------------------------------------------------------------------
Fee summary Charged
---------------------------
Paid Credited Due
Permit Fee Total 502.00
------------------------------
502.00 .00
.00
Plan Check Total .00
.00 .00
.00
Other Fee Total 350.00
350.00 .00
.00
Grand Total 852.00
852.00 .00
.00
BUILDING DEPT P E I E:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF'COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
08-00000225 Date 1/28/08
524300
3319 KEEFER LOOP
660030-0104-0020
R304778
TEMP POLE
WILLIAMSGATE PH 1
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Owner Contractor
ROBBIE ROBINSON, LTD K M CUSTOM HOMES
3800 SH-6 S 232 SOUTHWEST PKWY E
STE 104 COLLEGE STATION TX 77840
COLLEGE STATION TX 778455840 (979) 589-3739
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . AC
Permit pin number . 547802
Permit Fee . . . . 20.00
Issue Date . . . . 1/28/08 Valuation . . . . 0
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 20.00 20.00 .00 .00
Grand Total 20.00 20.00 .00 .00
--+BUILDING DEPT REftqj'$, JE : �•
APPLICANT:
1 APPLICATION FOR BUILDING PERMIT DATEn / TR'cc REG AVf
CITY OF COLLEGE STATION1101 TEXAS AVENUE APPLICATION #
COLLEGE STATION, TX 77840
TEMP POLE #
C:rrvc�r Ccll.l.l{c,l Sr�'niw (979) 764-3670 (979) 764-3496 FAX
1'Lrvnr��-Ikivkpihnl k, rxn
WWW.CSTX.GOV
MADDRESS/LOCATION: C ,,C� Coo
LOT Z/BLOCK SUBDIVISION W'1L( s G'a SEC/PH
jM �
BUSINESS/OWNER NAME: oW 5 ;r- PHONE: 5 37- 2 2- J
CONTRACTOR/HOMEOWNER: PHONE:
CONTACT PERSON FOR REVIEW COMMENTS: PHONE:
FAX: EMAIL:_ Q
ELECTRICIAN: q PLUMBER: 1,
HVAC: °Gn GOOD CENTS (Residential only):
ACCESSORY/STORAGE M VING RE -ROOF
ADDITION EW CONSTRUCTION* SHELL ONLY
DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL
LOCATION REMODEURENOVATION*
DESCRIPTION OF WORK:
PROPOSED USE:
STRUCTURE USE:
HOMEOWNER ASSOC IATION/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: O a
TEXAS ACCESSIBILITY S ANDAfiD (TAS) PROJECT REGISTRATION# EAIWRJ
VALUATION: $ / I MTUER
REA: Z3� HEATED AREA: 17 Z
(C t � b PU
PI PUBLIC SEWE t OF BEDROOMS: `7
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
SEWER TAP: , INTERIOR WALL TYPE: S�oJ CI VVV
ll
WATER TAP:4 F� EXTERIOR WALL TYPE: f I*�
WIZE�j dy�.,-
O R TAP: - FOUNDATION TYPE:
SIZE �{/)
TEMP POLE Q.�� i 67/& _1� 1, ? ROOF TYPE:
GARAGE TYPE: �/ VSINGLE v► �`D"sOiUBLE TRIPLE E-1
ATTACHED rfD 79CpORT
SIGNATURE OF APPLICANT:
��( jv/
*If proposed work involves new commercial co truction or fa de improvements/renovations to an existing
commercial property, building elevations are required.
............................................................
Official Use Only
28-0,9 C ments:
—. NO
Plans Examiner Zoning Official YE or
— A JAG I N'1D a} Q= j4do s., * y
— 6+LAI, wr H
3acvZ;. �4 «es�
— /No?`f?V" 6111c /,
— /i1,4,R,+�•, u.,, K �ullY SaRao� Ik lb t/^o . G /btxve �omc. Ii�O y'
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
® Chemical Termiticide Treatment (Soil Treatment)
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
* Verification of Application shall be submitted to the City of College Station
Building Division prior to issuance of the Certificate of Occupancy.
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
: CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning cr Development Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER#
DATE:
BUILDING ADDRESS:
I. Foundation Requirements- Minimum City Foundation Standards
NMW
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
O
II. Framing:
Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
QbOK
E.
Header sizes indicated on plans
NA/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q.
Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
OK
OK
.1 (*�
CITY OF COLLEGE STATION
Planning d Development Services
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
OK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
IfA,10K
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
N
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
CITY OF COLLEGE STATION
Planning d' Development Services
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N K
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
JA4 �_ -
PLANS EXAMINER
DATE