INSPECTION TICKET PAGE 1
City of
College Station
INSPECTOR: BUILDING INSPECTOR DATE 11/17/08
------------------------------------------------------------------------------------------------
ADDRESS
. : 2230 ROCKINGHAM LOOP SUBDIV: CASTLEGATE SEC 3 PH 1
CONTRACTOR CORDOBA
GROUP, INC
PHONE
OWNER
CORDOBA
GROUP INC
PHONE
PARCEL
184200-1302-0100
APPL NUMBER: 08-00000018
RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
2/08/08
OC
BLDG, FOUNDATION -SLAB TIME: 17:00
2/08/08
AP
February 7, 2008 11:19:15 AM kwolfe.
FRIDAY AFTERNOON
Strings On Setbacks O.K.
Slab Ground Installed
B115 01
4/29/08
BI
BLDG, FRAMING TIME: 17:00
5/01/08
CA
April 29, 2008 12:37:57 PM acarter.
B115 02
5/02/08
BB
BLDG, FRAMING TIME: 17:00
5/02/08
DP
May 2, 2008 8:42:56 AM malford.
05/02/2008 12:10 PM BB PDA
Need proper APA. Need anchor bolts on wall in family room.
Need fire blocking at fireplace. Draft stop chases.
B115 03
5/09/08
RH
BLDG, FRAMING TIME: 17:00
5/09/08
DP
May 8, 2008 4:31:43 PM acarter.
Friday afternoon please
05/09/2008 04:22 PM RH PDA
'
Need fireblock on each side of fireplace at arches. Finish
fireplace flue. Need proper APA nailing grid and nuts on
anchors at small garage. Tape seal around windows, doors,
water heaters and penetrations through Tyvek. Need temp
glass on each side of door for sunroom. Joist hangers in
front bathroom. Anchors at doors. Draftstop all chases.
Upstairs bedroom windows exceed 4411 maximum height from
finish floor.
B115 04
5/16/08
RH
BLDG, FRAMING TIME: 17:00
5/16/08
AE
May 15, 2008 3:35:23 PM acarter.
05/16/2008 10:53 AM RH PDA
Need to finish fireplace flue and no screws through flue
pipe. Also need more draftstop at arches by fireplace
flue. By insulation. Need temp glass at sunroom by
building final.
B130 01
5/20/08
RH
BLDG, INSULATION TIME: 17:00
5/20/08
AE
May 19, 2008 11:02:27 AM glsouth.
TUESDAY AFTERNOON
05/20/2008 02:07 PM RH PDA
Need temp glass at sunroom and finish fireplace flue
through chase and cap by building final.
B125 01 10/31/08 BB BLDG, FINAL TIME: 17:00
11/03/08 DP October 31, 2008 2:15:17 PM glsouth.
Re -label electrical panel. Post energy requirements in
panel. Irrigation installed.
B125 02 11/17/08 BI BLDG, FINAL TIME: 17:00
November 17, 2008 8:52:50 AM ccourt.
----------------------- --------------- COMMENTS AND NOTES--------------------------------------
7�.�»,�� 7r�,.11ad 10`6
2828
•
A-i. Termites
P.O. Box 5481, Bryan, TX 77805-5481
979-589-1203 Ofc 979-589-3655 Fax
Certificate of Completion
This certificate verifies the completion of the
preconstruction treatment for subterranean termites for
the property listed below.
Cordoba Group
223o Rockingham Loop
College Station, TX 77845
This property is guaranteed against subterranean termite
infestation from 5 February 20o8 thru 5 February 2010.
2 ws-s,elLL C . t3 re/LwwcL
RUSSELL C. BRELAND, CA
WF0994347 / 001 City of College Station PAGE 1
REQ. DATE: 01/07/08 01/07/08 13:07:46
LOCATION: 2230 ROCKINGHAM LOOP LOC ID: 192378
REQUESTOR: CORDOBA GROUP, INC ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
4" SWR TAP 3/4" WTR TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 01/07/08 SCHED COMPLETION: 01/07/08
********************************************************************************
JOB ORDER RESULT COMMTrS
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEQE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
08-00000018 Date 1/07/08
522962
I2230 ROCKINGHAM LOOP
184200-1302-0100
R110372
RESIDENTIAL, 1 UNIT DETACHED NEW
CASTLEGATE SEC 3 PH 1
RESIDENTIAL
PLANNED DEVL HOUSING
275000
Owner Contractor
------------------------ ------------------------
CORDOBA GROUP INC CORDOBA GROUP, INC
1920 W VILLA MARIA RD 1920 W. VILLA MARIA #301
STE 301 BRYAN TX 77807
BRYAN TX 778074858
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
3.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
4042.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TRAFFIC IMPACT ANAL (TAZ)
441.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
KW
Permit pin number .
543470
Permit Fee . . . .
985.00 Plan Check Fee
.00
Issue Date . . . .
1/07/08 Valuation . .
. . 275000
Expiration Date . .
7/05/08
Qty Unit Charge Per Extension
BASE FEE 460.00
175.00 3.0000 THOU BLDG, VAL 100001-500000 525.00
----------------------------------------------------------------------------
Special Notes and Comments
-Be Aware that right side of property has 10' PUE.
--------------------------------------------- ----- - --------------
BUILDING DEPT REPRES VE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 08-00000018
Application pin number . . . 522962
Special Notes and Comments
"'4-Spoke with Rahan about ceiling joist spans.
�-Need to assure proper GFI placements.
Page 2
Date 1/07/08
-Narrow Wall Bracing Fully Sheathed with APA 18" Minimum
Framing on Single Garage and Interior Anchors and Bracing at
Family Room Wall.
*ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
*PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
*PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
*Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
*PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
*Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
*ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
*ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
*MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
*Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
*ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL
RESIDENTIAL CODE
------------------------------ -----------------------A-
-- ---- �---------
BUILDING DEPT REP ENTAT VE:_ f
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 08-00000018 Date 1/07/08
Application pin number . . . 522962
----------------------------------------------------------------------------
Special Notes and Comments
*PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
*ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
*Assure Proper GFI Locations, Including One Within 25, Of
Outside A/C Unit
*PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
*ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED
IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
*IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
*REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
*A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
*THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
*ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
*MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
*If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
*RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
*For residential applications with_.a_glazi g area that
-
------------------------------------
---------
----lf�J• --------
BUILDING DEPT REP. TkTIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 4
Application Number . . . . . 08-00000018 Date 1/07/08
Application pin number . . . 522962
----------------------------------------------------------------------------
Special Notes and Comments
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
*PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
*SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
*PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
*SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
*THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 200-. A .40 OR LOWER FACTOR AND ABOVE 200
TO 3001 A .35 FACTO OR LOWER SHALL BE MET.
*ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
*SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
*REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
*STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
*WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
*TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
*AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
*PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
----------------------------------------------------12-- --- - --------
BUILDING DEPT REPR VE:
v
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 5
Application Number . . . . . 08-00000018 Date 1/07/08
Application pin number . . . 522962
----------------------------------------------------------------------------
Special Notes and Comments
IRC)
*RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
*IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR
FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING
MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE
ROOM.
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
----------------------------------------------------------------------------
Fee summary
-----------------
Permit Fee Total
Plan Check Total
Other Fee Total
Grand Total
Charged
985. 0
.00
750.00
1735.00
Paid Credited Due
985.00 .00 .00
.00 .00 .00
750.00 .00 .00
1735.00 .00 .00
------------------------------------------------ ----- - -- - --------
BUILDING DEPT RE :��
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101,TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R. #•
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
08-00000019
607571
2230 ROCKINGHAM LOOP
184200-1302-0100
R110372
TEMP POLE
CASTLEGATE SEC 3 PH 1
RESIDENTIAL
PLANNED DEVL HOUSING
0
Owner Contractor
Date 1/07/08
CORDOBA GROUP INC
CORDOBA GROUP, INC
1920 W VILLA MARIA
RD
1920 W. VILLA MARIA
#301
STE 301
BRYAN
TX 77807
BRYAN
TX 778074858
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE PERMIT
Additional desc .
. KW
Permit pin number
. 543488
Permit Fee . . .
. 20.00
Issue Date . . .
. 1/07/08
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . . TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid Credited
Due
-----------------
Permit Fee Total
----------
----------
--------------------
20.00 .00
.00
Other Fee Total
AL
45.00 .00
.00
Grand Total
65.00 .00
.00
------------------------------------------------------ -- - ---------
BUILDING DEPT REP E:
APPLICANT:
APPLICATION FOR BUILDING PERMIT
I CITY OF COLLEGE STATION
1101 TEXAS AVENUE
�i COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning d'DrvrlopmenrServirrr WWW CSTX.GOV
ADDRESS/LOCATION:
223 o fo c Rin
Fw OW Use Only
DATE (� ,O TRCC RE
APPLICATION # '
TEMP POLE #
LOT 10 BLOCK 2 ✓ SUBDIVISION Q)S+4a,CI wl te ✓ $EC/PH- l
BUSINESS/OWNER NAME: C,0CcQ0 b&,_ 6) (o 1n a tyllc. PHONE: 59'7
CONTRACTOR/HOMEOWNER: If
CONTACT PERSON FOR REVIEW COMMENTS:
ELECTRICIAN:
PHONE:
PHONE: ----
EMAIL: Y•P I" • IO I (% (Ofdo 1,C G4 Ke - C rV%
PLUMBER: T"$
HVAC: Q&,,ut°_ rr-•N GOOD CENTS (Residential only):
ACCESSORY/STORAGE MOVING RE -ROOF
ADDITION NEW CONSTRUCTION` SHELL ONLY
DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL
LOCATION REMODEL/RENOVATION" TENTS
DESCRIPTION OF WORK: NeW SE12— .
PROPOSED USE: fZPAtjpry '.I .
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS)/PROJECT REGISTRATION# EABPRJ
VALUATION: $ A-7 oOO ✓ TOTAL AREA: /2_• HEATED AREA: (-10�I Z
(Cost of Lab6r and Materials)
PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
�iX SEWER TAP:
SIZE
Pq WATER TAP. 3I 4
SIZE
❑ OTHER TAP:
Z TEMP POLE
GARAGE TYPE:
SIZE
SINGLE D
ATTACHED Fkl
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS: • 5
INTERIOR WALL TYPE: LI
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE TRIPLE
DETACHED CARPOR
_LA L
SIGNATURE OF APPLICANT:
'If proposed work involves new commercial cons ruction or fa a improvements/renovations to an existing
commercial property, building elevations are required.
............................................................
Official Use Only
C ents:
�� 7v�g ES rN0
Plans Examiner Zoning Official _ rvN s..k&Ak#V (AW+tl s��¢
/.KAAa 44"keW Apo( 18 MciviFfetau/,,(S f zw"h
J
/✓ srww P"W GFr Loc4Aa: 4-m- K;4d,-1 ' �2rk,'►� 07,d 4„l)y /14V AhA
01 94M
i
Energy Code Compliance Information
r
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
�6
Protection Against Subterranean Termites
�] Chemical Termiticide Treatment (Soil Treatment)
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
* Verification of Application shall be submitted to the City of College Station
Building Division prior to issuance of the Certificate of Occupancy.
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning& Development Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# Q _ J a
DATE:
BUILDING ADDRESS:
13 v j�ocfC i �G.w. 1 0
I. Foundation Requirements-- Minimum City Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NKM
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
K
E.
Header sizes indicated on plans
N
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four (44) inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
San exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q.
Tempered Glass required in all hazardous locations
R.
S.
18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
All walls within 3' of property line to have protected openings.
/OK
/OK
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning crDevelopment Service; COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
N
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA4r
1. Electrical fixtures & switches indicated
2. Smoke detector location(sl indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
(*t/q5* ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning 6'Development Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N K
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NAM
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NqqN
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N ffjK
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
N OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
/v 7,06
PLANS EXAMINER DATE