Loading...
HomeMy WebLinkAboutRES2008-00158 2412 STONE CASTLE CIR BUILDING PERMITPREPARED 7/18/08, 12:02:47 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/18/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 2412 STONE CASTLE CIR SUBDIV: CASTLEGATE PH 1 SEC 7 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER . . PHONE PARCEL . . 184200-1720-0240 APPL NUMBER: 08-00000158 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 2/26/08 OC BLDG, FOUNDATION -SLAB TIME: 17:00 2/26/08 AP February 26, 2008 9:51:17 AM kwolfe. Strings On Setbacks O.K. Slab Ground Installed B115 01 4/10/08 RH BLDG, FRAMING TIME: 17:00 4/10/08 DP April 9, 2008 12:07:37 PM npadilla. OSB SHEATHING FRONT AND BACK OF HOUSE IS COVERED CANNOT SEE NAILING PATTERN. ALL OTHER OSB ON INTERIORWALLS EXCEEDS 4" O.C. AT EDGES AND 12110.C. IN THE FIELD NAILING PATTERN. NEED TO BLOCK BETWEEN FLOOR JOIST ABOVE WALLS AT GARAGE. NEED HILTI FASTNERS ON FLOOR PLATES MIN 16" O.C. " DRAFTSTOP CHASES UPSTAIRS. BOTTOM PLATES ON 2ND FLOOR SHALL BE NAILED WITH 16 NAILS EVERY 12". 2ND FLOOR WINDOW WILL _ NEED TO BE MIN. 24" ABOVE FINISH FLOOR. B115 02 4/16/08 RH BLDG, FRAMING TIME: 17:00 4/16/08 DP April 16, 2008 12:03:34 PM npadilla. 04/16/2008 05:04 PM RH PDA Need proper nailing pattern for wind bracing on exterior and interior walls OSB. Need to block between floor joist above walls between garage and house. Need draft stop for chase upstairs. B115 03 4/18/08 RH BLDG, FRAMING TIME: 17:00 4/18/08 AP reinspect April 18, 2008 10:19:14 AM malford. B130 01 4/23/08 RH BLDG, INSULATION TIME: 17:00 4/23/08 AP April 23, 2008 9:37:09 AM acarter. B132 01 4/28/08 OC BLDG, SHEETROCK FASTENER TIME: 17:00 4/28/08 AP April 28, 2008 10:14:54 AM acarter. B125 01 7/18/08 BI wQ BLDG, FINAL TIME: 17:00 01 July 18, 2008 8:33:56 AM acarter. -------------------------------------- COMMENTS AND NOTES -------------------------------------- Q WF1042796 / 001 City of College,Station PAGE 1 REQ. DATE: 06/04/08 06/04/08 8:56:58 LOCATION: 2412 STONE CASTLE CIR LOC ID: 208148 REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: SWR 4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 06/04/08 SCHED COMPLETION: 06/04/08 ******************************************************************************** JOB ORDER RESULT COMCMTS PREPARED 4/10/08, 8:06:49 INSPECTION TICKET PAGE 11 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/09/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 2412 STONE CASTLE CIR SUBDIV: CASTLEGATE PH 1 SEC 7 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER . . PHONE PARCEL . . 184200-1720-0240 APPL NUMBER: 08-00000158 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 2/26/08 OC BLDG, FOUNDATION -SLAB TIME: 17:00 2/26/08 AP February 26, 2008 9:51:17 AM kwolfe. Strings On Setbacks O.K. Slab Ground Installed B115 01 4/09/08 BI BLDG, FRAMING TIME: 17:00 q' 0- April 9, 2008 12:07:37 PM npadilla. -------------------------------------- COMMENTS AND NOTES ----------------------------(---------- OS ,..�-,, ro , I I c� `� s e /�lf1 x� l4 0` & Pry�2 e.<Ce_ek C_110� '_j" "'� 1;2- (.( C;,C. ry q-44,e44 AA,)eJ :�2�S4cf a 13�m P 1 P�6- d 0'� -P__ NP l J LJJ 4� d rv'4'1�:5 eu'wa p-11 glqi) P(m t Lff�,dN A_) (,,Z J 1 [ Mltj_�) b-e- MIN Vt Apr. 4, 2008 9:39AM Stylecraft Builders, ,Inc. No. 8561 P. 15 "Shielding & Protecting Homes Against Pests" Renewable S Year Subterranean Termite Retreatment Agreement (Does not cover any other species of Termites) This agreement provides for retreatment only of the infested areas covered under the original treatment areas (See Graph). illlt!"/l T/ Jf11rlj CustotherName Date Billing Name if different ,� y12 � lure C4 -.7- C Street Address of treated structure Billing Address if different City State Zip Code City State gg Zip Code )(nitial Termite Cost S Home Phone Work Phone Additional Renewals Paid Other Type of Treatment Partial Bait Yrm-rreat Tax Treatment for. )( Prevention Control of Subterranean CashiCheck# Total S .� Termites Payment S Not": Balance S Credit Card: Type Exp. Date Card Number 5 Year Subterranean Termitlagm ,tment Guarantee: RP Lee Termite and Pest Control will retreat the structure for Subterranean Termites at no cost to the customer, if an infestation of Subterranean Termites is found, as long as the original treatment is paid in full and the customer is current on their yearly renewals_ This Agreement will expire in one (1) year unless the customer elects to pay the yearly warranty fee. The guarantee can be renewed for up to five (5) years by paying the yearly warranty fcc. RP Lcc Termite and Post Control may approve additional warranty years 4cr the five (5) years with an additional increase in the yearly warranty fee. The guarantee does not cover any damages to the structure or contents of the customer. The customer agrees to control all condusive conditions that may cause reinfestation. If the structure is modified, added onto, altered, or if the soil treatment around the structure is removed the customer must contact RP Lcc Termite and Pest Control and pay for additional treatment in order to keep the guarantee in effect. 1£tbe customer does not pay for additional treatment the retreatmeut guarantee can be cancelled. V, WaLwaLFee: Customer may elect to renew the retreatment guarantee for additional years. The renewal fee is S SU, ' plus tax. The renewal fee is due on or before the annual anniversary date or paid SZ plus tax every third (3) month with inspection. Mgigtgining the Guarantee: The customer agrees to comet all condusivc conditions, at owner's expense, as they exist or as they occur in the future in order for the guarantee not to be cancelled. Customer will make the structure available for inspections and treatments as requested by RP Lcc Termite and Pest Control. Reineneetlon_ RP Lee Termite and Pest Control will reinspect the structure at customers request or any other times RP Lee Termite and Pest Control deems necessary. RP Lee Termite and Pest Control recommends that the customer call and set up an annual inspec- tion at the time of customers yearly renewal. Transfer: This agreement maybe transferred to anew owacr with the payment of a transfer fee of S '1� , copy of the Wood Destroying Insect Report from the sell, and approval of RP Lcc Termite and Pest Control. Ter itc Formosan Wood Boring Reetles. CnMentpr Ants. or any other wood destro3 ft insects qr organisms. Arbitration: In the event of any dispute arising out of this agreement or any other services performed or not performed the parties above agree to participate in mediation through and in accordance with the commercial mediation rules of the American Arbitration Association. The Arbitrator shall consider the legal defenses raised in the arbitration, and the decision of the arbitrator shall be final, binding, non -appealable and may be entered and enforced in any court having jurisdiction in accordance with the Federal Arbitration Act. Limitation of Llahility: Landscaping and grass next to the slab may be damaged during treatment, carpet may need to be pulled up in certain arras around the home, drill holes may need to be made in Boor coverings such as tilt or linoleum or in cabinets next to pipe areas, and holes may need to be cut in walls. Caetomer agrees not to hold RP Lcc Tcrmitc and Pest Control liable for these damages, or treatment techniques, or other damages that may occur during treatment. Agreement: This Agreement shall be the entire agreement between customer and RP LeeTermite and Pest Control. If any partof this agreement is found to be imalid it shall not affect the validity of any other part of the Agreement. We are Ucennd by the Structural Pest Control Board - 333-Guadalupe. STtke I-530 A.10.si2L=Tl711_SI2405-5250 RP Lee Term�WPest Control Cert. Apl.# Customer Signature Date �'• Apr. 4. 2008 9:39AM Stylecraft Builders, ,Inc. No.8561 P. 14 New Construction Subterranean Termite �'11 � �pui°"� "°. i (exp. iar3112(X15; Soft Treatment Record TIVS form IS cDm=touA by tho tln&mod Poot CQntrd COn MY jyu11C nlppl�lry0 burden for tb* Colod i d Ydoenatim it Osornam to owomO16 Mminuhu -.----p If�o tiro foi �ynamrrj r>i rucCult. ►uitekiL+yT odWn7 data aour.as, 4aMorin0 and mal =WflO Via Cala neWud. and OMVIOdK and f0i"Iny dta oollecOW M lydwmalm. tha Omm slim w mandatory and a fs4tmd to eb" bbn95te. HUD My nal odW he idormaclon, and you are trot nqulrnd to amalots tlli:; town, urlo;,a it ul joys a cvrratV crrld CUB rencot nuatbo:. , C O:kn 24 CFA MOMOM) revs diet"r tos to HO loused 0mciumo meet bo bog ut larmlto h=fdt. Thar hIMMtwn CoWIM'Miu s trle WAOU' to +erWy ttw an mel:artiod Pent CjxdM rw4wy parlamed all requtrad U1f:urarlt Cr WOW. and that Hju boxer yuaragow dta umed area apal= ueocrae'n Wr ores you, Dutdara, pest COIttn7) aampnr6m• mortl]apo Iandore, hmWlfyw-% and I LAG Aa a reead of troMW. er qA&A%: Femme Mh uae au, Jllu'rM U GOICued. LN iaroMATW . c mA d,truldimW ar_f.,dwdnL_ This rapo.K iCaubnrlttaXtor. Informational purposas io the bWtdur on proposed (now) r:a Mloc4lor CWVS. WhV, ^roa tras;rfont tar praVantlon a c„btprrunpa,n lwmitrr infscwa )n to opeclflod by yto S:,ddor, wcwtoot, ur requitud by thu Imrdur, ivehilem. FF:A. nr V.4. A;l r1 '=fads for sOrtrM WO DOtwoor.'lm Yoal Control Operator and OUldar, unlots SWad uthon�aa. Saviloa 1: General InformMlon (Treating CCihpgrq hddo rne;ionj ;% C.omllvty NAMO: „ �. P �C c 7erPW iT C IL ?,es 1 eflv7l'l company Addr000 -?,. P . -8ot F_y//_Z3 --city . e.f s4rla . TX ap 77v YS CpmpanY guslnatc ! mnse ta0. R4 Company Ftlarm No. ^�(v Z. Z fR WA Cana Nb. (I! OM f*aflan 21 l;lulider Information CompanyNamo -_._ ld •7F+jtana�Na. —-- $eelteA 3: Areparh Intormarttan ,•.•M �O"• 7 �G•��"'a"C G� �`��� Lovitlon of Seuctiao is) Tioutod (Slrval A4&os3 cr Lood Da'+alpllon. City. We And ZIP) C • - 9i' 71 y 7M of CbAsbuolion (Mmo U*n Ono ilex may bo obod.co) 8I41) 'r G►aoma.t L Crx A Otter Apprp hAbDoprri of FoM,q; OiAWdr.,_ — Intlds — Typo of Fill Sodfwr 4: TnatOM t lnfarradlon Date(e) of TrwdMongo) &and Name of Pmd=fr,) VrAd EPA AeAlW*Son No. Approximala FM Wx Solution % Approxlrnato SItA of Troelmont Aron: n. _ r Uaear R ' �P uresr t . of Merartry Vo'rsa _ —_ __ AMxwtlrr+alo Total Gallons of Sduttorl Wed was lr"Marf. co Woted an uxMdor7 0 Yas M No 8enlraAgranmauAtralteAlv7 Ya>; L NO Note: $Onto stole lawn roquiro Al sgroemants to bs iser�md Thio turn duos ntu DroeMPt state low. Atuo"Ortb Ni3l) Frame ut Applk a- gs) CerOcadon No. (!! rcauked by WIx utw) z % ? 7__ Tho appocalor has usod s prodtrst in awv dlwns vAh the product Iabal and slate reyulYomanif Ajl tra44-mil rnalorLelt AM MOMQ s vsoJ COmply WKh rusts and fadsrol r,4sVwh ionr. Authorized Vj)Antum Own wOrlrtt}� HUD rt! proracula fafsa �d�r4':,eur fill—v.Grnm3,m mAy!m31121 i, cMwtnl.jv'Y.v nal rur,vtr.'In (id,U_f• t:. t+n1 rein 7rJtl;:it 11;,•(:, 7 x Y�?j — Folrn NPCA-" may $02 bo toot± Ice ia twaHFCa-90-3 jwluaa) h " Apr. 4. 2008 9:39AM S t y I e c r a f t Builders, Inc. No.8561 P. 16 SUBTERRANEAN TERMITE PRE -CONSTRUCTION TREATMENT DISCLOSURE FOR EACH ESTIMATE Licensed and regulated under the Texas Structural Pest Control Act RP LEE TERMITE & PEST CONTROL PO Box 9423 • College Station, TX 77842 • (972) 690-8622 , TPCL #11486 —CUSTOMER INFORYAT)ON: Name; 5 U//e ea,,4 F7 Aalxw Phone #1: Phone #2: Address: �City State: Zip Code: ^ Location to be Treated; �� J /4wc CR 3 71 C - 3 . 7el %a For all treatments there will be a diagram showing exactly what will be treated priorto the beginning of treatment. Review the pesticide label pmvldedteyouatthis time for minimum treatment standards. Remember that your architects or design engineers specifications must also be followed, unless they are in violation of the law. Review the consumer Information sheet for further information. If you have any questions, contact the pest co I eom irly or the Texas Structural Pest Control Board, P 0 Box 1927, Austin, TX 78767.1927. Telephone number (512) 305-8250. Before conducting a termite preconstruction treatment, the company will present a complete diagram of the structure Including construction details. When construction prevents performance of a full treatment, In accordance with a bid for full treatment any change to a partial treatment by the company provtd'mg the treatment will be permitted if the owner of the structure or the person in Charge of the construction and the certified applicator for the pest control company sign a statement attesting to the construction conditions. The agreement must be attached to the contract with an amended diagram showing the exact areas to be treated Copies must be sent to the owner of the property within seven days of the application, notes: Xo'/lwe4,ec Diagraiii of Propose(I Area(s) To Be G� I� eI ��tto�l■trl�■� t�. W—M rim 4e e asp �vvv X 1,2 06 Type of treatment proposed: (check all that apply); 0 Full YPartial f(Wood'1 ❑ Bait 0 Commercial YSingle Family Total square feet to be treated: Total linear feet to be treated: Approximate measurements of structures) to be treated;Z� E A label of & A c4 ✓J c termiticide(s) is attached. The percentage of the termlttcide(s) to be applied at this location Estimated amount of terrniilcide to be applied i!yy / / gallon(s), THE SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE 18 ATTACHED ON BACK (8PCBID-4). THE BOARD APPROVED SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE MUST BE PROVIDED TO, AND SIGNED BY THE CONTRACTOR OR PURCHASER OF THE PRECONSTRUCTION TREATMENT SERVICE. Complete detalls of warranty (II any) Including time period of warranty, renewal options and cost, and obligations of the contracting parties Is attached. If the warranty does not include the entire structure treated, the areas included in the warranty are (specify): N A consuNnfonnation sheet is also attached. lee 3-27-06' oeew < < el't.;—./ 3 • z 7-r�G Signature of CA or nician Printed Name Date Si nature of Cu st er Verifying Receipt of This Document Date ITEMo STPRM-2-� O+A&Dr Natik Copy. Service Provider Yellow Copy• Customer rpm, 0WFW,,, RhWby Lnv&-u,k CWnW 2m IMVE4 s, D,As, rx ytum Service Treatment Invoice 3-7 7-11.5' , Date: Appoiot'1Time: �T nmfpm r EE Route: hlap Code: H+Y Frequency: M L;hl Q S Y Stmil"me: mI FinlsYTime. amlpm r 1 Structure: / ail} Crawl PlB Combo a '4pe of Servile: nitial Regular Folkww Up Ouc Time Charily Pets: Dogs Cat(s) Birds} fish ASV-' IL "Shielding & Protecting � Homes Against Pests" q �, �� ' (1, Service Add Cost of service $ ti 7PCL #1 146 Q?*7G kr t-T Name: _il ?eJ , - Billing: Tax $ Payment by: - -^�� Address:' J Lac irl�T�f Total Due Cash a City: . 5 TX 7 7,,L Y-T Payment $ Check L3 # Phone: Balance S ��fi• Credit Card CI PEST PROBLEMS:. ��3r/P'- �rrAf7"1t"xt+7 DIRECTIONS I INSTRUCTIONS: PAYMENT DUE EQUIP. MUFIL LOCATION(S) PRODUCT QTY TARGET PEST(S) UPON RECEIPT WOOD DESTROYING INSECTS _ '1'trmWor SCWipruoil A6% SublerryaeanTerndtes, Ants Sise ofTiank Posted ¢' 'UrmWur NW-Flpronll .96% SuhterryntanlLrmitca. Size ol"rank rusted I.J Bury-conoDhorllumOctabomicletrabyJaleSD% tr/f SuLlcrnoeanfFurnosaafDrywrooJlermites[orpenfer,lnls,Htetles, Poe led W c GENERAL PESTS Invader HPH-Baygoa 1% CarpenterAnlr, Spiders, Crickets, Millipedes, Hceucr, termites. � Demon WP-Cywlo-PhenoocyphcvgI Cockrvuha, Millipedes, Smwbugs, Flies, licks,141osquitos, Pillb•gr. Dimethpcyleyclopropaworlstaybtte 1% 5ihxr/ish, Bu-m,Acts, Carpenter Ants, Sevrpions, Spidem— - 7enpo Ullm WP-Cyttulhrin .WS9: (Rcsl) Ants (Except Pharaoh),CocLmndws, Crickets, Earwlgs,A1L0Iipcdes. hlics, Fruit Flics, Bettles, (gca sorfacespray, spot, mist, crock & crevice) PillbuM Silverfish, Spiders. Gnah.Bamels,'"'eeps,VeLlow Jackels. lidslerEZWfiatitris.2% Ants, Cendpedca,Cuckroachcs,Crbclets,G�atislroppers�Scorp3ons,7'1eYs,5r11ertish Spidcrr. Mlacrorce4lydmimlhylont%-2.l5% PharaebAnh.Crickets CorpecterAats,Lg.kosebes,VariclyofAnls. Cykidt CS Cylluthrin M91a Spider; Scorpiaor,Aots, CmrpealerAuh, Carpenter Bees, Raotches, Crickets, Silvm&k. Pbanton .5% Pharoh Anls,variely of Ants, poaches. FLEAS leiq arJ PermetArin S'4 Fleas,licks,Aids, Cestipcelm CarpeolerAals, Bees, V1Lsps, Carpenter Bears, Cockreselres, Crickets, Flics, Earwig:, Millipedes, Beelles, Pillbugs. Saapeod SC-Dehaaetarin 4.75°% (RES]) Fleas, Bees, Berner, Ltaaches, Crickets, L1ce, Mies, Scorp9on36'1'ick8, Wasps. Nyguard-'sielhyktnony 10% (RES.1) [Cp-0rmvt1i RegulstorFlw, Roaches, Crickets, Hying ]reeds, Sload Yroduct Pests. Ercile R Pyretlrin A5% Fkas. MICE. RODENTS, RATS. MONITORS Faslrso-Bromctlsytln Aly. M11ce,Rolknls, Ratr, Bait SlaOua-LorgelSmyli Glue Busuds Mlles, kodeot% Halo, Bog Alonilon. OTHER Speckowl'yrocide .50% Kaasdlles, Moselultos, Moths, Fleas, ►Allsps, 1lornels,Tlcks, Carckroaches. z Bl&a 14 Bireylbria .06% Spider; Ants, Roaches, Silverfish, Earwigs, Flms, Scorplom o CDO Equip A -Compressed Sprayer P-PowerSptayer B-Bait Dispenser BS-Bait Slation ST-Bait Trap D-Aerosol Can G-Ghw Board 11-Hand Duster S-Spreader F-Fogger Fbf-Foarner AC-ACtlsol unit Other rn Locadan : 1-Kitcbm bBatli(s) 3-Bc&uurm 4-Dining Room 5-Uttl]ty f-Stmage 7-CommonArew 8-Garap 9-forester of Structure liLAWC 11-Yard 12-Uader Hunic 13-1Va dmiso 14-01lice 1 S-Bxposud Ubod 2' up from Slab Othcr Mediod oflWatments: CC -Crack & Crevice SS -Sub -Slab Injeetion WNW Treatment UP -Bait Placement HS-Broadcast Spray PB-Perimeter Barder BV-1lrick Venirc WT-Wood Treatment � PRECAUTIONS: Do not touch treated areas till dry. Do not tamper with bait stations. 'Ventilate rooms after treatment. Keep pets. away until pesticides have dried. —� Licenced by the Structural Pest Control Board - 333 Guadalupe, Suite I-530 • Austin, TX 78701 •512-3054250 SERVICE TECHNICIAN: !/ r CUSTOMER SIGNATURE: ,� ��l J��� ar • %C DATE- Plellse review the Customer Iurormitiion on (lie olhcr side of [moice P.O. Box 9423 • College Station, TX 77842 • (979) 690-8622 • Fax (979) 690-8840 WFI001218 / 001 City of College Station PAGE 1 REQ. DATE: 01/31/08 C "01/31/08 15:35:58 LOCATION: 2412 STONE CASTLE CIR LOC ID: 208148 REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE: SWR 4" WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 01/31/08 SCHED COMPLETION: 01/31/08 ******************************************************************************** JOB ORDER RESULT COMMENTS AREA M FMSHING NOTES SUMMARY -IY11IR [I I 1 Notes LL w w w .)v0!:.]wwv] i wc Ig 01 M -�MN�OiCwl1' MASTER BEDROOM More Home, Less Money 13'419�:•16-0• Q�Q i VU¢ O WNr i � P•r/ a' Q QiLY 0OL1 �aF OW�//wwV)LL MQIE O c 04 ww�w¢¢Q� PORCH MBvTH �j QU>04 1r-r z 10-r ^ BREAKFAST�� N Q U C7 a LOCATION 10'.!• x 10'-0• SUBDIV. CG7 �� — — — — — — PHASE 1 BLOCK 2 °�' I L 24 IIIGAME ROOM BEDROOM 2 II LIE 'x1 °x11 16'-9• x 175' 11'-10' x 175• LIVING I �I I BATH �I r II KITCHEN y-0• I ,v-s z s'a1 o UTILITY TANDEM GARAGE . m �nI o A11LHE - -( MEDIA ROOM - - i °-0 0 `, ll'3' : 12'-B' IWI U pp FORMAL DINING ® BEDROOM 3 V U 9. -0 N 1'E• x 11'-10• GALLERY BATH 17-11' x 12'J' ry POWDER ® re iel l( � F Wz TWO CAR GARAGE FU'�ER _— OPEN TO BELOW COMMENTS O I I I� I BEDROOM 4 STUDY Y I 11'4 17-0• 10'-119x •12'i' PORCH N U �x I I 7'-6' x 7'-„• N a BUILDING ENVELOPE [- I NOTICE ST PLAN PREVIEW ND PLAN PREVIEW THIS SET OF DRAWINGS FOR A HOME IS THE 1 SCALE:3/32"=1'-O" - L 2SCAI.F:3/32"=1'-0" COPYRIGHTED PROPERTY OF STYLECRAFT - — BUILDERS, INC. THIS SINGLE COPY IS LICENSED AND NO RIGHT TO REPRODUCE, COPY OR DUPLICATE ALL OR ANY PORTION OF THE LICENSED PLANS IS GRANTED, EITHER EXPRESSLY OR IMPLIED. 5 ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS _ INDICATED OR REPRESENTED BY THE DRAWING ARE OWNED BY AND THE PROPERTY OF THE DESIGNERS AND WERE CREATED, EVOLVED AND DEVELOPED F FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, 7 E DESIGNS, ARRANGEMENTS OR PLANS SHALL BE ;, ® Z USED BY OR DISCLOSED TO ANY PERSON, FIRM OR O CORPORATION FOR ANY PURPOSE WHATSOEVER _ WITHOUT THE WRITTEN PERMISSION OF THE j ® -- 0 E 0 U e t iDESIGNERS. - - 3 Il oo E i 0 11U1 15TU J® .. . SHEET: AFRO/NT ELEVATION _ G_ 1 COVER SE�ET SHEET INDEX COVER SHEET G-1 GENERAL NOTES G-2 SITE PLAN C-1 FOUNDATION PLAN S-1 DIMENSION PLAN S-2 DETAILS S-3 BRACING PLAN_____ S-4 FRAMING PLAN S-5 ROOF FRAMING PLAN S-6 DECKING LAYOUT S-7 ELEVATIONS S-8 FRAMING DETAILS r��LCTRICAL PLAN S-9 E-1 FLOOR PLAN A-1 FLOORING PLAN A-2 A-3 CABINET LAYOUT PLAN APPROVAL APPROVED INITIALS DATE ADMINISTRATOR / SUPERINTENDENT / CUSTOMER � / AREA SUMMARY t�oV)cnci,u.vi �� ��MNVIMC/�tr 0 �� 1710r- UU 0' QNQ ¢ ¢ O a. Pq a OO�wW[s.va�[i �� 2O,Q lO'Q �NQUOC¢7000. o`)c`y��yJ ry�;�QsF A LOCATION SUBDE . CGl PHA 3,Q BLOCK 2 1 24 ryoLOT od, I 02�o I GIN TI mT Q.L • I FEN E W/ ,••�� (NV O ON� GATE Or c U u m� U a AU ENCE Iu o M In o •o, 1 � cv) w z M O O U x N Uo N a >4 ONT S TBACK WA ` 1 6 '%I s - ° 2412 STONE CASTLE CIRCLE CASTLEGATE 7 5- FRON FUE a ° LOT - 24 BLOCK-2 3.49 PHASE-1 d G d ~ z oQzw-I a � F_ F` 2412 STONE CASTLE Cl CLE aH�v f arz aWW� 1 SITE PLAN SHEET: C_ 1 SCALER"=20'-0" SITE PLAN BUILDING PERMIT CITY OF 9,DLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 08-00000158 Date 1/31/08 Application pin number . . . 503416 Property Address . . . . . . 2412 STONE CASTLE CIR Property ID: 184200-1720-0240 R #• Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE PH 1 SEC 7 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 207174 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 3139.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 441.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit pin number . 548727 Permit Fee . . . . 784.00 Plan Check Fee .00 Issue Date . . . . 1/31/08 Valuation . . . . 207174 Expiration Date . . 7/29/08 Qty Unit Charge Per Extension BASE FEE 460.00 108.00 3.0000 THOU BLDG, VAL 100001-500000 324.00 ---------------------------------------------------------------------------- Special Notes and Comments -Make Sure 2nd Floor Operable Windows are Minimum 24" AFF *ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING ----------------------------------------------- ----- --- -------------- BUILDING DEPT REPRF�fEI�T�j V.F,__ APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 08-00000158 Application pin number . . . 503416 Page 2 Date 1/31/08 Special Notes and Comments UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) *PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY *PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. *Garage ceiling must have 5/8" Type X sheetrock when there is Habitable space above the garage. *PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE *Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS *ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET *MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND *Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) *ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE *PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER *ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED *Assure Proper GFI Locations, Including One Within 25, Of Outside A/C Unit *PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE ------------------------------------------------- ------ ---- ----- -------- BUILDING DEPT REPR TATIVE APPLICANT: n�/ BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 08-00000158 Application pin number . . . 503416 Page 3 Date 1/31/08 Special Notes and Comments OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES *PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION *Wall and Ceiling Insulation are as follows respectively. If Wall to Window Ratio is up to 1501 the Values Shall be R-13 and R-30, above 15o the Ceiling Insulation is Increased to R-38. *ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING *IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. *REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT *A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 *THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' *ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UPS *MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI *RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE *For residential applications with a glazing area that ---------- ------------------ ----- - - ---- BUILDING DEPT REPRE NTA ,I- APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEG)E STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 08-00000158 Date 1/31/08 Application pin number . . . 503416 ---------------------------------------------------------------------------- Special Notes and Comments exceeds 151W of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. *PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. *SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR *PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES *THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET. *ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY *SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS *REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. *STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. *WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS *TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS *AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE *PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 08-00000158 Date 1/31/08 Application pin number . . . ---------------------------------------------------------------------------- 503416 Special Notes and Comments IRC) *U-Factor Ratings for Window % up to 1501 is .65, from 150-6 to 20% is .55, from 20% to 25% is .54 and above 25% is .46 or lower. *RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC *IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE ROOM. *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK *GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged ----------------- Paid Credited Due ---------- Permit Fee Total 784.00 ------------------------------ 784.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1534.00 1534.00 .00 .00 ----------------------------------- ------ ----------- BUILDING DEPT REPRESENT : _, _ . _ !/C _ _ �/ • APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 08-00000159 Date 1/31/08 Application pin number . . . 607868 Property Address . . . . . . 2412 STONE CASTLE CIR Property ID: 184200-1720-0240 R #. Application type description TEMP POLE Subdivision Name . . . . . . CASTLEGATE PH 1 SEC 7 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KW Permit pin number . 548735 Permit Fee . . . . 20.00 Issue Date . . . . 1/31/08 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged Paid Credited Due Permit Fee Total ---------- 20.00 ------------------------------ 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ----------------------------------------------- ---- -- �---------- BUILDING DEPT REPRESENTA IV. APPLICANT: 18� APPLICATION FOR BUILDIING PERMIT DATE" TRCC RE f 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 APPLICATION # i CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX TEMP POLE # Planning & DevelopmentSa vice WWW.CSTX.GOV ADDRESS/LOCATION: N1 STONE CASTLE Cl�. ✓ LOT 24 V BLOCK 2✓ SUBDIVISION 61AIT6 / SEC/PH BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTACT PERSON FOR REVIEW COMMENTS: ERIC WIVAGG PHONE: 690-1222 ext. 120 FAX: 690-0348 EMAIL: ewivagg(cDstylecraft-builders.com ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS (Residential only): No ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION ` SLAB ONLY DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL Il TENT/CANOPY DESCRIPTION OF WORK: Conventional Framing PROPOSED USE: Sinale Family Residence WALL BRACING METHOD: PRESCRIPTIVE ❑ APA PORTAL FRAME W/ CSPS`� ENGINEERED HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ W-7 17 � '/ TOTAL AREA: HEATED AREA: 3� (Cost of Labor and Materials) [X PUBLIC SEWER SEPTIC/TREATMENT SYSTEM 0 QX SEWER TAP: 4" SIZE XX WATER TAP: 3/" SIZE OTHER TAP: 7 SIZE TEMP POLE S6 GARAGE TYPE: SINGLE El q�� ATTACHED X NUMBER OF BEDROOMS: A NUMBER OF BATHROOMS: INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE FOUNDATION TYPE ROOF TYPE: DOUBLE F__] TRIPLE RPORT SIGNATURE OF APPLICANT: \ *If proposed work involves new commercial 'cbnstrustie r facade it commercial property, building elevations are required. / Official USe OnI v I-22-a8 —F/P Plans Examiner Siding and/or Masonry Slab on Grade Composition 9 17 0 For St lecraft t v ' nsj leg . ing so �+aa�1 1�^`• •Fw,y v ZfAjA19 Comments: 's7s,'4 �,e,1 i 1� G*.vyc. 1 may' Energy Code Compliance Information % Glazing of exterior walls .4 % Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 / Glazing SHGC (Solar Heat Gain Coefficient) .35 / Glazing U-Factor .53 R value of ductwork R6 A/C SEER Rating 13 Protection Against Subterranean Termites ❑ Chemical Termiticide Treatment (Soil Treatment) Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other *Verification of Application shall be submitted to the City of College Station Building Department prior to issuance of the Certificate of Occupancy. REScheck Software Version 3.7.3 Compliance Certificate, Project Title: 3135 Plan Report Date: 01/17/08 Data filename: S:\ACAD\RESCheck\3135.00-2412 Stone Castle.rck Energy Code: 2003 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 14% Heating Degree Days: 1788 Construction Site: 2412 Stone Castle College Station, TX 77845 Owner/Agent: Stylecraft Builders, Inc. 4090 SH 6 South College Station, TX 77845 979-690-1222 x134 jsaucier@stylecraft-builders.com Maximum SHGC: 0.40 Your SHGC: 0.35 Wall 1: Wood Frame, 16" o.c.: Window 1: Metal Frame:Double Pane with Low-E: SHGC: 0.35 Door 1: Solid: Door 2: Glass: SHGC: 0.40 Wall 2: Wood Frame, 16" o.c.: Ceiling 1: Flat Ceiling or Scissor Truss: Floor 1: Slab -On -Grade: Unheated: , Insulation Depth: 0.0' Floor 2: All -Wood Joist/Truss:Over Unconditioned Space: Furnace 1: Forced Hot Air: 80 AFUE Air Conditioner 1: Electric Central Air: 13 SEER Permit # Permit Date Designer/Contractor: Stylecraft Builders, Inc. 4090 SH 6 South College Station, TX 77845 979-690-1222 x134 jsaucier@stylecraft-builders.com 2130 13.0 0.0 127 508 0.530 269 38 0.500 19 38 0.440 17 1699 13.0 0.0 139 1957 30.0 0.0 68 237 0.0 247 252 13.0 0.0 16 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.7.3 and to comply with the ma a o requirements I' d in the REScheck Inspection Checklist. SiYI.eC�e.�f � o$ Builder/Designer Company fiLme Dat Project Notes: All U-Factors and SHGC are at entered at higher than actual amounts. Actual amounts are lower, but are entered higher to account for differences in ratings per material. 3135 Plan Page 1 of 1 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning trDevelopment Services COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# 1 S $ DATE: BUILDING ADDRESS: a q 2DA& &-W4 Ce RL I. Foundation Requirements- Minimum Ci Foundation Standards N A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated IMOK II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. K K i (*f/"" CITY OF COLLEGE STATION Planning d Development Service; PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements A. Stairwa Details N 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NA/ 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location CITY OF COLLEGE STATION Planning d Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101- TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units) T B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NA/ Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision . Plat filed Flood lain Regulations — Ordinance 1301 NA Does not block any water course or divert any flow Elevation certificate needed OK "APPROVED PLANS PER IRC SECTION R106.3.1." PLANS EXAMINER J-23-o6 DATE