HomeMy WebLinkAboutRES2008-00158 2412 STONE CASTLE CIR BUILDING PERMITPREPARED
7/18/08,
12:02:47
INSPECTION TICKET PAGE 3
City of
College Station
INSPECTOR: BUILDING INSPECTOR DATE 7/18/08
------------------------------------------------------------------------------------------------
ADDRESS
. : 2412 STONE
CASTLE
CIR SUBDIV: CASTLEGATE PH 1 SEC 7
CONTRACTOR
STYLECRAFT BUILDERS
PHONE (979) 690-1222
OWNER .
.
PHONE
PARCEL .
. 184200-1720-0240
APPL NUMBER: 08-00000158
RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING
PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
2/26/08
OC
BLDG, FOUNDATION -SLAB TIME: 17:00
2/26/08
AP
February 26, 2008 9:51:17 AM kwolfe.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01
4/10/08
RH
BLDG, FRAMING TIME: 17:00
4/10/08
DP
April 9, 2008 12:07:37 PM npadilla.
OSB SHEATHING FRONT AND BACK OF HOUSE IS COVERED CANNOT SEE
NAILING PATTERN. ALL OTHER OSB ON INTERIORWALLS EXCEEDS 4"
O.C. AT EDGES AND 12110.C. IN THE FIELD NAILING PATTERN.
NEED TO BLOCK BETWEEN FLOOR JOIST ABOVE WALLS AT GARAGE.
NEED HILTI FASTNERS ON FLOOR PLATES MIN 16" O.C.
"
DRAFTSTOP CHASES UPSTAIRS. BOTTOM PLATES ON 2ND FLOOR SHALL
BE NAILED WITH 16 NAILS EVERY 12". 2ND FLOOR WINDOW WILL
_
NEED TO BE MIN. 24" ABOVE FINISH FLOOR.
B115 02
4/16/08
RH
BLDG, FRAMING TIME: 17:00
4/16/08
DP
April 16, 2008 12:03:34 PM npadilla.
04/16/2008 05:04 PM RH PDA
Need proper nailing pattern for wind bracing on exterior
and interior walls OSB. Need to block between floor joist
above walls between garage and house. Need draft stop for
chase upstairs.
B115 03
4/18/08
RH
BLDG, FRAMING TIME: 17:00
4/18/08
AP
reinspect
April 18, 2008 10:19:14 AM malford.
B130 01
4/23/08
RH
BLDG, INSULATION TIME: 17:00
4/23/08
AP
April 23, 2008 9:37:09 AM acarter.
B132 01
4/28/08
OC
BLDG, SHEETROCK FASTENER TIME: 17:00
4/28/08
AP
April 28, 2008 10:14:54 AM acarter.
B125 01
7/18/08
BI wQ
BLDG, FINAL TIME: 17:00
01
July 18, 2008 8:33:56 AM acarter.
-------------------------------------- COMMENTS AND NOTES --------------------------------------
Q
WF1042796 / 001 City of College,Station PAGE 1
REQ. DATE: 06/04/08 06/04/08 8:56:58
LOCATION: 2412 STONE CASTLE CIR LOC ID: 208148
REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE:
SWR 4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 06/04/08 SCHED COMPLETION: 06/04/08
********************************************************************************
JOB ORDER RESULT COMCMTS
PREPARED 4/10/08, 8:06:49 INSPECTION TICKET PAGE 11
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/09/08
------------------------------------------------------------------------------------------------
ADDRESS . : 2412 STONE CASTLE CIR SUBDIV: CASTLEGATE PH 1 SEC 7
CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222
OWNER . . PHONE
PARCEL . . 184200-1720-0240
APPL NUMBER: 08-00000158 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 2/26/08 OC BLDG, FOUNDATION -SLAB TIME: 17:00
2/26/08 AP February 26, 2008 9:51:17 AM kwolfe.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 4/09/08 BI BLDG, FRAMING TIME: 17:00
q' 0- April 9, 2008 12:07:37 PM npadilla.
-------------------------------------- COMMENTS AND NOTES ----------------------------(----------
OS
,..�-,, ro , I I c� `� s e /�lf1 x� l4 0` & Pry�2
e.<Ce_ek C_110� '_j" "'� 1;2- (.( C;,C. ry q-44,e44
AA,)eJ
:�2�S4cf a
13�m P 1 P�6- d 0'� -P__ NP l J LJJ 4� d
rv'4'1�:5 eu'wa p-11
glqi) P(m t Lff�,dN A_) (,,Z J 1 [ Mltj_�) b-e- MIN Vt
Apr. 4, 2008 9:39AM Stylecraft Builders, ,Inc.
No. 8561
P. 15
"Shielding & Protecting
Homes Against Pests"
Renewable S Year
Subterranean
Termite Retreatment
Agreement
(Does not cover any other species of Termites)
This agreement provides for retreatment only of the infested areas covered under the original treatment areas (See Graph).
illlt!"/l T/ Jf11rlj
CustotherName Date Billing Name if different
,� y12 � lure C4 -.7- C
Street Address of treated structure
Billing Address if different
City State Zip Code City State gg Zip Code
)(nitial Termite Cost S
Home Phone Work Phone Additional Renewals Paid
Other
Type of Treatment Partial Bait Yrm-rreat Tax
Treatment for. )( Prevention Control of Subterranean CashiCheck# Total S .�
Termites Payment S
Not": Balance S
Credit Card:
Type Exp. Date Card Number
5 Year Subterranean Termitlagm ,tment Guarantee: RP Lee Termite and Pest Control will retreat the structure for Subterranean
Termites at no cost to the customer, if an infestation of Subterranean Termites is found, as long as the original treatment is paid in full
and the customer is current on their yearly renewals_ This Agreement will expire in one (1) year unless the customer elects to pay
the yearly warranty fee. The guarantee can be renewed for up to five (5) years by paying the yearly warranty fcc. RP Lcc Termite
and Post Control may approve additional warranty years 4cr the five (5) years with an additional increase in the yearly warranty fee.
The guarantee does not cover any damages to the structure or contents of the customer. The customer agrees to control all condusive
conditions that may cause reinfestation. If the structure is modified, added onto, altered, or if the soil treatment around the structure
is removed the customer must contact RP Lcc Termite and Pest Control and pay for additional treatment in order to keep the guarantee
in effect. 1£tbe customer does not pay for additional treatment the retreatmeut guarantee can be cancelled. V,
WaLwaLFee: Customer may elect to renew the retreatment guarantee for additional years. The renewal fee is S SU, ' plus tax.
The renewal fee is due on or before the annual anniversary date or paid SZ plus tax every third (3) month with inspection.
Mgigtgining the Guarantee: The customer agrees to comet all condusivc conditions, at owner's expense, as they exist or as they
occur in the future in order for the guarantee not to be cancelled. Customer will make the structure available for inspections and
treatments as requested by RP Lcc Termite and Pest Control.
Reineneetlon_ RP Lee Termite and Pest Control will reinspect the structure at customers request or any other times RP Lee Termite
and Pest Control deems necessary. RP Lee Termite and Pest Control recommends that the customer call and set up an annual inspec-
tion at the time of customers yearly renewal.
Transfer: This agreement maybe transferred to anew owacr with the payment of a transfer fee of S '1� , copy of the Wood
Destroying Insect Report from the sell, and approval of RP Lcc Termite and Pest Control.
Ter itc
Formosan Wood Boring Reetles. CnMentpr Ants. or any other
wood destro3 ft insects qr organisms.
Arbitration: In the event of any dispute arising out of this agreement or any other services performed or not performed the parties
above agree to participate in mediation through and in accordance with the commercial mediation rules of the American Arbitration
Association. The Arbitrator shall consider the legal defenses raised in the arbitration, and the decision of the arbitrator shall be final,
binding, non -appealable and may be entered and enforced in any court having jurisdiction in accordance with the Federal Arbitration
Act.
Limitation of Llahility: Landscaping and grass next to the slab may be damaged during treatment, carpet may need to be pulled
up in certain arras around the home, drill holes may need to be made in Boor coverings such as tilt or linoleum or in cabinets next
to pipe areas, and holes may need to be cut in walls. Caetomer agrees not to hold RP Lcc Tcrmitc and Pest Control liable for these
damages, or treatment techniques, or other damages that may occur during treatment.
Agreement: This Agreement shall be the entire agreement between customer and RP LeeTermite and Pest Control. If any partof
this agreement is found to be imalid it shall not affect the validity of any other part of the Agreement.
We are Ucennd by the Structural Pest Control Board - 333-Guadalupe. STtke I-530
A.10.si2L=Tl711_SI2405-5250
RP Lee Term�WPest Control Cert. Apl.# Customer Signature Date
�'• Apr. 4. 2008 9:39AM Stylecraft Builders, ,Inc. No.8561 P. 14
New Construction Subterranean Termite �'11 � �pui°"� "°. i (exp. iar3112(X15;
Soft Treatment Record
TIVS form IS cDm=touA by tho tln&mod Poot CQntrd COn MY
jyu11C nlppl�lry0 burden for tb* Colod i d Ydoenatim it Osornam to owomO16 Mminuhu -.----p If�o tiro foi �ynamrrj r>i rucCult. ►uitekiL+yT
odWn7 data aour.as, 4aMorin0 and mal =WflO Via Cala neWud. and OMVIOdK and f0i"Iny dta oollecOW M lydwmalm. tha Omm slim w mandatory and a
fs4tmd to eb" bbn95te. HUD My nal odW he idormaclon, and you are trot nqulrnd to amalots tlli:; town, urlo;,a it ul joys a cvrratV crrld CUB rencot
nuatbo:. ,
C O:kn 24 CFA MOMOM) revs diet"r tos to HO loused 0mciumo meet bo bog ut larmlto h=fdt. Thar hIMMtwn CoWIM'Miu s trle WAOU' to
+erWy ttw an mel:artiod Pent CjxdM rw4wy parlamed all requtrad U1f:urarlt Cr WOW. and that Hju boxer yuaragow dta umed area apal= ueocrae'n Wr
ores you, Dutdara, pest COIttn7) aampnr6m• mortl]apo Iandore, hmWlfyw-% and I LAG Aa a reead of troMW. er qA&A%: Femme Mh uae au, Jllu'rM U GOICued.
LN iaroMATW . c mA d,truldimW ar_f.,dwdnL_
This rapo.K iCaubnrlttaXtor. Informational purposas io the bWtdur on proposed (now) r:a Mloc4lor CWVS. WhV, ^roa tras;rfont tar praVantlon a c„btprrunpa,n
lwmitrr infscwa )n to opeclflod by yto S:,ddor, wcwtoot, ur requitud by thu Imrdur, ivehilem. FF:A. nr V.4.
A;l r1 '=fads for sOrtrM WO DOtwoor.'lm Yoal Control Operator and OUldar, unlots SWad uthon�aa.
Saviloa 1: General InformMlon (Treating CCihpgrq hddo rne;ionj ;%
C.omllvty NAMO: „ �. P �C c 7erPW iT C IL ?,es 1 eflv7l'l
company Addr000 -?,. P . -8ot F_y//_Z3 --city . e.f s4rla . TX ap 77v YS
CpmpanY guslnatc ! mnse ta0. R4 Company Ftlarm No. ^�(v Z. Z
fR WA Cana Nb. (I! OM
f*aflan 21 l;lulider Information
CompanyNamo -_._ ld •7F+jtana�Na. —--
$eelteA 3: Areparh Intormarttan ,•.•M �O"• 7 �G•��"'a"C G� �`���
Lovitlon of Seuctiao is) Tioutod (Slrval A4&os3 cr Lood Da'+alpllon. City. We And ZIP) C • - 9i' 71 y
7M of CbAsbuolion (Mmo U*n Ono ilex may bo obod.co) 8I41) 'r G►aoma.t L Crx A Otter
Apprp hAbDoprri of FoM,q; OiAWdr.,_ — Intlds — Typo of Fill
Sodfwr 4: TnatOM t lnfarradlon
Date(e) of TrwdMongo)
&and Name of Pmd=fr,) VrAd
EPA AeAlW*Son No.
Approximala FM Wx Solution %
Approxlrnato SItA of Troelmont Aron: n. _ r Uaear R ' �P uresr t . of Merartry Vo'rsa _ —_ __
AMxwtlrr+alo Total Gallons of Sduttorl Wed
was lr"Marf. co Woted an uxMdor7 0 Yas M No
8enlraAgranmauAtralteAlv7 Ya>; L NO
Note: $Onto stole lawn roquiro Al sgroemants to bs iser�md Thio turn duos ntu DroeMPt state low.
Atuo"Ortb Ni3l)
Frame ut Applk a- gs)
CerOcadon No. (!! rcauked by WIx utw) z % ? 7__
Tho appocalor has usod s prodtrst in awv dlwns vAh the product Iabal and slate reyulYomanif Ajl tra44-mil rnalorLelt AM MOMQ s vsoJ COmply WKh
rusts and fadsrol r,4sVwh ionr.
Authorized Vj)Antum
Own
wOrlrtt}� HUD rt! proracula fafsa �d�r4':,eur fill—v.Grnm3,m mAy!m31121 i, cMwtnl.jv'Y.v nal rur,vtr.'In (id,U_f• t:. t+n1 rein 7rJtl;:it 11;,•(:, 7 x Y�?j —
Folrn NPCA-" may $02 bo toot± Ice ia twaHFCa-90-3 jwluaa)
h
" Apr. 4. 2008 9:39AM S t y I e c r a f t Builders, Inc. No.8561 P. 16
SUBTERRANEAN TERMITE PRE -CONSTRUCTION TREATMENT DISCLOSURE FOR EACH ESTIMATE
Licensed and regulated under the Texas Structural Pest Control Act
RP LEE TERMITE & PEST CONTROL
PO Box 9423 • College Station, TX 77842 • (972) 690-8622 , TPCL #11486
—CUSTOMER INFORYAT)ON:
Name; 5 U//e ea,,4 F7 Aalxw Phone #1: Phone #2:
Address: �City State: Zip Code:
^
Location to be Treated; �� J /4wc CR 3 71 C - 3 . 7el %a
For all treatments there will be a diagram showing exactly what will be treated priorto the beginning of treatment. Review the pesticide label pmvldedteyouatthis time for minimum treatment standards.
Remember that your architects or design engineers specifications must also be followed, unless they are in violation of the law. Review the consumer Information sheet for further information. If you
have any questions, contact the pest co I eom irly or the Texas Structural Pest Control Board, P 0 Box 1927, Austin, TX 78767.1927. Telephone number (512) 305-8250.
Before conducting a termite preconstruction treatment, the company will present a complete diagram of the structure Including construction details. When construction prevents performance of a full
treatment, In accordance with a bid for full treatment any change to a partial treatment by the company provtd'mg the treatment will be permitted if the owner of the structure or the person in Charge of
the construction and the certified applicator for the pest control company sign a statement attesting to the construction conditions. The agreement must be attached to the contract with an amended
diagram showing the exact areas to be treated Copies must be sent to the owner of the property within seven days of the application,
notes: Xo'/lwe4,ec
Diagraiii of
Propose(I
Area(s)
To Be
G�
I�
eI
��tto�l■trl�■�
t�.
W—M
rim
4e e asp
�vvv X 1,2
06
Type of treatment proposed: (check all that apply); 0 Full YPartial f(Wood'1 ❑ Bait 0 Commercial YSingle Family
Total square feet to be treated: Total linear feet to be treated: Approximate measurements of structures) to be treated;Z� E
A label of & A c4 ✓J c termiticide(s) is attached. The percentage of the termlttcide(s) to be applied at this location
Estimated amount of terrniilcide to be applied i!yy / / gallon(s),
THE SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE 18 ATTACHED ON BACK (8PCBID-4). THE BOARD APPROVED SUBTERRANEAN TERMITE
PRECONSTRUCTION TREATMENT BUILDERS GUIDE MUST BE PROVIDED TO, AND SIGNED BY THE CONTRACTOR OR PURCHASER OF THE PRECONSTRUCTION TREATMENT
SERVICE. Complete detalls of warranty (II any) Including time period of warranty, renewal options and cost, and obligations of the contracting parties Is attached. If the warranty does not
include the entire structure treated, the areas included in the warranty are (specify): N
A consuNnfonnation sheet is also attached.
lee 3-27-06' oeew < < el't.;—./ 3 • z 7-r�G
Signature of CA or nician Printed Name Date Si nature of Cu st er Verifying Receipt of This Document Date
ITEMo STPRM-2-� O+A&Dr Natik Copy. Service Provider Yellow Copy• Customer rpm, 0WFW,,, RhWby Lnv&-u,k CWnW 2m IMVE4 s, D,As, rx ytum
Service Treatment Invoice 3-7 7-11.5'
, Date: Appoiot'1Time: �T nmfpm
r
EE
Route: hlap Code: H+Y Frequency: M L;hl Q S Y
Stmil"me: mI FinlsYTime. amlpm r 1 Structure: / ail} Crawl PlB Combo
a
'4pe of Servile: nitial Regular Folkww Up Ouc Time Charily Pets: Dogs Cat(s) Birds} fish ASV-' IL
"Shielding & Protecting
�
Homes Against Pests" q �, �� ' (1,
Service Add Cost of service $
ti
7PCL #1 146 Q?*7G
kr t-T
Name: _il ?eJ , - Billing: Tax $ Payment by: -
-^��
Address:' J Lac irl�T�f Total Due Cash a
City: . 5 TX 7 7,,L Y-T Payment $ Check L3 #
Phone: Balance S ��fi• Credit Card CI
PEST PROBLEMS:. ��3r/P'- �rrAf7"1t"xt+7 DIRECTIONS I INSTRUCTIONS:
PAYMENT DUE
EQUIP. MUFIL LOCATION(S) PRODUCT QTY TARGET PEST(S) UPON RECEIPT
WOOD DESTROYING INSECTS
_
'1'trmWor SCWipruoil A6% SublerryaeanTerndtes, Ants Sise ofTiank Posted
¢'
'UrmWur NW-Flpronll .96% SuhterryntanlLrmitca. Size ol"rank rusted
I.J Bury-conoDhorllumOctabomicletrabyJaleSD% tr/f SuLlcrnoeanfFurnosaafDrywrooJlermites[orpenfer,lnls,Htetles, Poe led
W
c
GENERAL PESTS
Invader HPH-Baygoa 1% CarpenterAnlr, Spiders, Crickets, Millipedes, Hceucr, termites.
�
Demon WP-Cywlo-PhenoocyphcvgI Cockrvuha, Millipedes, Smwbugs, Flies, licks,141osquitos, Pillb•gr.
Dimethpcyleyclopropaworlstaybtte 1% 5ihxr/ish, Bu-m,Acts, Carpenter Ants, Sevrpions, Spidem—
-
7enpo Ullm WP-Cyttulhrin .WS9: (Rcsl) Ants (Except Pharaoh),CocLmndws, Crickets, Earwlgs,A1L0Iipcdes. hlics, Fruit Flics, Bettles,
(gca sorfacespray, spot, mist, crock & crevice) PillbuM Silverfish, Spiders. Gnah.Bamels,'"'eeps,VeLlow Jackels.
lidslerEZWfiatitris.2% Ants, Cendpedca,Cuckroachcs,Crbclets,G�atislroppers�Scorp3ons,7'1eYs,5r11ertish Spidcrr.
Mlacrorce4lydmimlhylont%-2.l5% PharaebAnh.Crickets CorpecterAats,Lg.kosebes,VariclyofAnls.
Cykidt CS Cylluthrin M91a Spider; Scorpiaor,Aots, CmrpealerAuh, Carpenter Bees, Raotches, Crickets, Silvm&k.
Pbanton .5% Pharoh Anls,variely of Ants, poaches.
FLEAS
leiq arJ PermetArin S'4 Fleas,licks,Aids, Cestipcelm CarpeolerAals, Bees, V1Lsps, Carpenter Bears, Cockreselres,
Crickets, Flics, Earwig:, Millipedes, Beelles, Pillbugs.
Saapeod SC-Dehaaetarin 4.75°% (RES]) Fleas, Bees, Berner, Ltaaches, Crickets, L1ce, Mies, Scorp9on36'1'ick8, Wasps.
Nyguard-'sielhyktnony 10% (RES.1) [Cp-0rmvt1i RegulstorFlw, Roaches, Crickets, Hying ]reeds, Sload Yroduct Pests.
Ercile R Pyretlrin A5% Fkas.
MICE. RODENTS, RATS. MONITORS
Faslrso-Bromctlsytln Aly. M11ce,Rolknls, Ratr,
Bait SlaOua-LorgelSmyli Glue Busuds Mlles, kodeot% Halo, Bog Alonilon.
OTHER
Speckowl'yrocide .50% Kaasdlles, Moselultos, Moths, Fleas, ►Allsps, 1lornels,Tlcks, Carckroaches.
z
Bl&a 14 Bireylbria .06% Spider; Ants, Roaches, Silverfish, Earwigs, Flms, Scorplom
o
CDO
Equip A -Compressed Sprayer P-PowerSptayer B-Bait Dispenser BS-Bait Slation ST-Bait Trap D-Aerosol Can G-Ghw Board 11-Hand Duster S-Spreader F-Fogger Fbf-Foarner AC-ACtlsol unit Other
rn
Locadan : 1-Kitcbm bBatli(s) 3-Bc&uurm 4-Dining Room 5-Uttl]ty f-Stmage 7-CommonArew 8-Garap 9-forester of Structure liLAWC 11-Yard 12-Uader Hunic 13-1Va dmiso 14-01lice 1 S-Bxposud Ubod 2' up from Slab Othcr
Mediod oflWatments: CC -Crack & Crevice SS -Sub -Slab Injeetion WNW Treatment UP -Bait Placement HS-Broadcast Spray PB-Perimeter Barder BV-1lrick Venirc WT-Wood Treatment
�
PRECAUTIONS: Do not touch treated areas till dry. Do not tamper with bait stations. 'Ventilate rooms after treatment. Keep pets. away until pesticides have dried.
—�
Licenced by the Structural Pest Control Board - 333 Guadalupe, Suite I-530 • Austin, TX 78701 •512-3054250
SERVICE TECHNICIAN: !/ r CUSTOMER SIGNATURE: ,� ��l J��� ar • %C DATE-
Plellse review the Customer Iurormitiion on (lie olhcr side of [moice
P.O. Box 9423 • College Station, TX 77842 • (979) 690-8622 • Fax (979) 690-8840
WFI001218 / 001 City of College Station PAGE 1
REQ. DATE: 01/31/08 C "01/31/08 15:35:58
LOCATION: 2412 STONE CASTLE CIR LOC ID: 208148
REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 01/31/08 SCHED COMPLETION: 01/31/08
********************************************************************************
JOB ORDER RESULT COMMENTS
AREA
M FMSHING NOTES SUMMARY
-IY11IR [I I
1 Notes LL w w w
.)v0!:.]wwv]
i wc Ig 01 M
-�MN�OiCwl1'
MASTER BEDROOM
More Home, Less Money 13'419�:•16-0• Q�Q
i VU¢ O WNr
i � P•r/ a' Q QiLY
0OL1 �aF
OW�//wwV)LL
MQIE O c 04
ww�w¢¢Q�
PORCH MBvTH �j QU>04
1r-r z 10-r ^
BREAKFAST�� N Q U C7 a
LOCATION
10'.!• x 10'-0•
SUBDIV. CG7
�� — — — — — — PHASE 1
BLOCK 2
°�' I L 24
IIIGAME ROOM BEDROOM 2
II LIE 'x1 °x11
16'-9• x 175' 11'-10' x 175•
LIVING I �I I BATH
�I r
II KITCHEN
y-0• I
,v-s z s'a1 o UTILITY TANDEM GARAGE . m
�nI
o
A11LHE - -( MEDIA ROOM
- - i °-0 0
`, ll'3' : 12'-B'
IWI U pp
FORMAL DINING ® BEDROOM 3 V U
9. -0 N
1'E• x 11'-10• GALLERY BATH 17-11' x 12'J'
ry POWDER ® re
iel
l( � F
Wz
TWO CAR GARAGE
FU'�ER _— OPEN TO BELOW COMMENTS
O
I I I� I BEDROOM 4
STUDY Y I 11'4 17-0•
10'-119x •12'i'
PORCH N U
�x I I
7'-6' x 7'-„•
N a
BUILDING ENVELOPE [- I
NOTICE
ST PLAN PREVIEW ND PLAN PREVIEW
THIS SET OF DRAWINGS FOR A HOME IS THE 1 SCALE:3/32"=1'-O" - L 2SCAI.F:3/32"=1'-0"
COPYRIGHTED PROPERTY OF STYLECRAFT - —
BUILDERS, INC. THIS SINGLE COPY IS LICENSED AND
NO RIGHT TO REPRODUCE, COPY OR DUPLICATE ALL
OR ANY PORTION OF THE LICENSED PLANS IS
GRANTED, EITHER EXPRESSLY OR IMPLIED. 5
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS _
INDICATED OR REPRESENTED BY THE DRAWING ARE
OWNED BY AND THE PROPERTY OF THE DESIGNERS
AND WERE CREATED, EVOLVED AND DEVELOPED F
FOR USE ON AND IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, 7 E
DESIGNS, ARRANGEMENTS OR PLANS SHALL BE ;, ® Z
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR O
CORPORATION FOR ANY PURPOSE WHATSOEVER _
WITHOUT THE WRITTEN PERMISSION OF THE j ® -- 0 E 0 U e t
iDESIGNERS. - - 3 Il
oo
E i 0 11U1 15TU J® .. . SHEET:
AFRO/NT ELEVATION _ G_ 1
COVER SE�ET
SHEET INDEX
COVER SHEET
G-1
GENERAL NOTES
G-2
SITE PLAN
C-1
FOUNDATION PLAN
S-1
DIMENSION PLAN
S-2
DETAILS
S-3
BRACING PLAN_____
S-4
FRAMING PLAN
S-5
ROOF FRAMING PLAN
S-6
DECKING LAYOUT
S-7
ELEVATIONS
S-8
FRAMING DETAILS
r��LCTRICAL PLAN
S-9
E-1
FLOOR PLAN
A-1
FLOORING PLAN
A-2
A-3
CABINET LAYOUT
PLAN APPROVAL
APPROVED
INITIALS
DATE
ADMINISTRATOR
/
SUPERINTENDENT
/
CUSTOMER
� /
AREA
SUMMARY
t�oV)cnci,u.vi
��
��MNVIMC/�tr
0
��
1710r-
UU
0'
QNQ
¢
¢
O
a.
Pq
a
OO�wW[s.va�[i
��
2O,Q lO'Q
�NQUOC¢7000.
o`)c`y��yJ
ry�;�QsF
A
LOCATION
SUBDE .
CGl
PHA
3,Q
BLOCK
2
1 24
ryoLOT
od,
I
02�o I
GIN
TI mT
Q.L • I
FEN E W/
,••��
(NV
O
ON�
GATE
Or
c
U
u
m�
U a
AU
ENCE
Iu
o
M
In
o
•o,
1
�
cv)
w
z
M
O
O
U
x
N
Uo
N a
>4
ONT S TBACK
WA
`
1
6 '%I
s
-
°
2412 STONE CASTLE CIRCLE
CASTLEGATE 7
5- FRON FUE a °
LOT - 24
BLOCK-2
3.49
PHASE-1
d G d
~
z
oQzw-I
a
�
F_
F`
2412 STONE CASTLE Cl CLE
aH�v
f
arz
aWW�
1 SITE PLAN
SHEET:
C_ 1
SCALER"=20'-0"
SITE PLAN
BUILDING PERMIT
CITY OF 9,DLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 08-00000158 Date 1/31/08
Application pin number . . . 503416
Property Address . . . . . . 2412 STONE CASTLE CIR
Property ID: 184200-1720-0240
R #•
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . CASTLEGATE PH 1 SEC 7
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 207174
Owner Contractor
------------------------ ------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION TX 77845
(979) 690-1222
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 3139.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TRAFFIC IMPACT ANAL (TAZ) 441.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . KW
Permit pin number . 548727
Permit Fee . . . . 784.00 Plan Check Fee .00
Issue Date . . . . 1/31/08 Valuation . . . . 207174
Expiration Date . . 7/29/08
Qty Unit Charge Per Extension
BASE FEE 460.00
108.00 3.0000 THOU BLDG, VAL 100001-500000 324.00
----------------------------------------------------------------------------
Special Notes and Comments
-Make Sure 2nd Floor Operable Windows are Minimum 24" AFF
*ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
----------------------------------------------- ----- --- --------------
BUILDING DEPT REPRF�fEI�T�j V.F,__
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 08-00000158
Application pin number . . . 503416
Page 2
Date 1/31/08
Special Notes and Comments
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
*PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
*PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
*Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
*PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
*Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
*ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
*ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
*MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
*Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
*ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL
RESIDENTIAL CODE
*PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
*ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
*Assure Proper GFI Locations, Including One Within 25, Of
Outside A/C Unit
*PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
------------------------------------------------- ------ ---- ----- --------
BUILDING DEPT REPR TATIVE
APPLICANT: n�/
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 08-00000158
Application pin number . . . 503416
Page 3
Date 1/31/08
Special Notes and Comments
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
*PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
*Wall and Ceiling Insulation are as follows respectively.
If Wall to Window Ratio is up to 1501 the Values Shall be
R-13 and R-30, above 15o the Ceiling Insulation is Increased
to R-38.
*ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED
IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
*IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
*REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
*A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
*THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
*ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UPS
*MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
*If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD
*WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
*RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
*For residential applications with a glazing area that
----------
------------------ ----- - - ----
BUILDING DEPT REPRE NTA ,I-
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEG)E STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 4
Application Number . . . . . 08-00000158 Date 1/31/08
Application pin number . . . 503416
----------------------------------------------------------------------------
Special Notes and Comments
exceeds 151W of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
*PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
*SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
*PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
*SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
*THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION/WINDOW PRODUCTS DEPENDING ON PERCENTAGE OF WALL
TO GLAZING/WINDOW RATIO UP TO 20% A .40 OR LOWER FACTOR AND
ABOVE 20% TO 30% A .35 FACTOR OR LOWER SHALL BE MET.
*ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
*SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
*REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
*STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
*WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
*TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
*AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
*PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60"
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page
5
Application Number . . . . .
08-00000158 Date
1/31/08
Application pin number . . .
----------------------------------------------------------------------------
503416
Special Notes and Comments
IRC)
*U-Factor Ratings for Window %
up to 1501 is .65, from 150-6 to
20% is .55, from 20% to 25% is
.54 and above 25% is .46 or
lower.
*RANGE/DRYER DUCT MUST COMPLY
WITH 2O06 IMC
*IF AN OPERABLE WINDOW IS MORE
THAN 72" ABOVE EXTERIOR
FINISHED GRADE THEN THE LOWEST
PART OF THE WINDOW OPENING
MUST BE AT LEAST 24" ABOVE THE
FINSHED FLOOR FROM INSIDE THE
ROOM.
*ALL PLUMBING, ELECTRICAL, AND
HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS
PRIOR TO COVERING ANY WORK
*GAS APPLIANCES HAVING AN IGNITION
SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE
IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES
BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
----------------------------------------------------------------------------
Fee summary Charged
-----------------
Paid Credited Due
----------
Permit Fee Total 784.00
------------------------------
784.00 .00
.00
Plan Check Total .00
.00 .00
.00
Other Fee Total 750.00
750.00 .00
.00
Grand Total 1534.00
1534.00 .00
.00
----------------------------------- ------ -----------
BUILDING DEPT REPRESENT : _, _ . _ !/C _ _ �/ •
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 08-00000159 Date 1/31/08
Application pin number . . . 607868
Property Address . . . . . . 2412 STONE CASTLE CIR
Property ID: 184200-1720-0240
R #.
Application type description TEMP POLE
Subdivision Name . . . . . . CASTLEGATE PH 1 SEC 7
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. KW
Permit pin number
. 548735
Permit Fee . . .
. 20.00
Issue Date . . .
. 1/31/08
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
Paid Credited
Due
Permit Fee Total
----------
20.00
------------------------------
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
----------------------------------------------- ---- -- �----------
BUILDING DEPT REPRESENTA IV.
APPLICANT:
18�
APPLICATION FOR BUILDIING PERMIT DATE" TRCC RE f
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840 APPLICATION # i
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX TEMP POLE #
Planning & DevelopmentSa vice
WWW.CSTX.GOV
ADDRESS/LOCATION: N1 STONE CASTLE Cl�. ✓
LOT 24 V BLOCK 2✓ SUBDIVISION 61AIT6 / SEC/PH
BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTACT PERSON FOR REVIEW COMMENTS: ERIC WIVAGG PHONE: 690-1222 ext. 120
FAX: 690-0348 EMAIL: ewivagg(cDstylecraft-builders.com
ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing
HVAC: Control Temp GOOD CENTS (Residential only): No
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION ` SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL
Il TENT/CANOPY
DESCRIPTION OF WORK: Conventional Framing
PROPOSED USE: Sinale Family Residence
WALL BRACING METHOD: PRESCRIPTIVE ❑ APA PORTAL FRAME W/ CSPS`� ENGINEERED
HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A
VALUATION: $ W-7 17 � '/ TOTAL AREA: HEATED AREA: 3�
(Cost of Labor and Materials)
[X PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
0 QX SEWER TAP:
4"
SIZE
XX WATER TAP:
3/"
SIZE
OTHER TAP:
7
SIZE
TEMP POLE
S6 GARAGE TYPE:
SINGLE
El
q��
ATTACHED
X
NUMBER OF BEDROOMS: A
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE: Sheet Rock
EXTERIOR WALL TYPE
FOUNDATION TYPE
ROOF TYPE:
DOUBLE F__] TRIPLE
RPORT
SIGNATURE OF APPLICANT: \
*If proposed work involves new commercial 'cbnstrustie r facade it
commercial property, building elevations are required. /
Official USe OnI v
I-22-a8
—F/P Plans Examiner
Siding and/or Masonry
Slab on Grade
Composition
9 17 0 For St lecraft
t v ' nsj leg . ing
so
�+aa�1 1�^`• •Fw,y
v ZfAjA19 Comments:
's7s,'4 �,e,1 i 1� G*.vyc. 1 may'
Energy Code Compliance Information
% Glazing of exterior walls .4 %
Insulation R value of exterior walls R13
Insulation R value of ceiling 1 (flat areas) R30
Insulation R value of ceiling 2 (vaulted areas/no attic) R19 /
Glazing SHGC (Solar Heat Gain Coefficient) .35 /
Glazing U-Factor .53
R value of ductwork R6
A/C SEER Rating 13
Protection Against Subterranean Termites
❑ Chemical Termiticide Treatment (Soil Treatment)
Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
*Verification of Application shall be submitted to the City of College Station
Building Department prior to issuance of the Certificate of Occupancy.
REScheck Software Version 3.7.3
Compliance Certificate,
Project Title: 3135 Plan
Report Date: 01/17/08
Data filename: S:\ACAD\RESCheck\3135.00-2412 Stone Castle.rck
Energy Code:
2003 IECC
Location:
College Station, Texas
Construction Type:
Single Family
Glazing Area Percentage:
14%
Heating Degree Days:
1788
Construction Site:
2412 Stone Castle
College Station, TX 77845
Owner/Agent:
Stylecraft Builders, Inc.
4090 SH 6 South
College Station, TX 77845
979-690-1222 x134
jsaucier@stylecraft-builders.com
Maximum SHGC: 0.40 Your SHGC: 0.35
Wall 1: Wood Frame, 16" o.c.:
Window 1: Metal Frame:Double Pane with Low-E:
SHGC: 0.35
Door 1: Solid:
Door 2: Glass:
SHGC: 0.40
Wall 2: Wood Frame, 16" o.c.:
Ceiling 1: Flat Ceiling or Scissor Truss:
Floor 1: Slab -On -Grade: Unheated: , Insulation Depth: 0.0'
Floor 2: All -Wood Joist/Truss:Over Unconditioned Space:
Furnace 1: Forced Hot Air: 80 AFUE
Air Conditioner 1: Electric Central Air: 13 SEER
Permit #
Permit Date
Designer/Contractor:
Stylecraft Builders, Inc.
4090 SH 6 South
College Station, TX 77845
979-690-1222 x134
jsaucier@stylecraft-builders.com
2130
13.0
0.0
127
508
0.530
269
38
0.500
19
38
0.440
17
1699
13.0
0.0
139
1957
30.0
0.0
68
237
0.0
247
252
13.0
0.0
16
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in
REScheck Version 3.7.3 and to comply with the ma a o requirements I' d in the REScheck Inspection Checklist.
SiYI.eC�e.�f � o$
Builder/Designer Company fiLme Dat
Project Notes:
All U-Factors and SHGC are at entered at higher than actual amounts.
Actual amounts are lower, but are entered higher to account for
differences in ratings per material.
3135 Plan Page 1 of 1
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning trDevelopment Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 1 S $
DATE:
BUILDING ADDRESS:
a q 2DA& &-W4 Ce RL
I. Foundation Requirements- Minimum Ci Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
IMOK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q.
Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
K
K
i (*f/""
CITY OF COLLEGE STATION
Planning d Development Service;
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairwa Details
N
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
CITY OF COLLEGE STATION
Planning d Development Services
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101- TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
T
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NA/
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
.
Plat filed
Flood lain Regulations — Ordinance 1301
NA
Does not block any water course or divert any flow
Elevation certificate needed
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
PLANS EXAMINER
J-23-o6
DATE