Loading...
HomeMy WebLinkAboutRES2007-01563 2081 RAVENSTONE LOOP BUILDING PERMITWF0909697 / 001 City of College Station PAGE 1 REQ. DATE: 05/29/07 05/29/07 12:27:06 LOCATION: 2081 RAVENSTONE LOOP LOC ID: 191002 REQUESTOR: KEITH DOWNS CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE: 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 05/29/07 SCHED COMPLETION: 05/29/07 ******************************************************************************** JOB ORDER RESULT CONIl4=S City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning 4/16/08 184200-1102-0060 2081 RAVENSTONE LOOP COLLEGE STATION TX 77845 CASTLEGATE SEC 1 PH 1 CASTLEGATE SEC 1, PH 1, BLOCK 2, LOT 6 PLANNED DEVL HOUSING Owner . . . . . . . . . GREENS PRAIRIE INVESTORS LTD Contractor . . . . . . KEITH DOWNS CUSTOM HOMES 936 597-4871 Application number 07-00001563 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . . . r� Approved . . . . . . . Belding Official VOID UNLESS SIGNED BY BUILDING OFFICIAL City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 T E M P O R A R Y C O T E M P O R A R Y Issue Date . . . . . . Expiration Date . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning 4/15/08 4/25/08 184200-1102-0060 2081 RAVENSTONE LOOP COLLEGE STATION TX 77845 CASTLEGATE SEC 1 PH 1 CASTLEGATE SEC 1, PH 1, BLOCK 2, LOT 6 PLANNED DEVL HOUSING Owner . . . . . . . . . GREENS PRAIRIE INVESTORS LTD Contractor . . . . . . KEITH DOWNS CUSTOM HOMES 936 597-4871 Application number 07-00001563 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . . . Special conditions . . 1. Mount address block. 2. Post insulatI certificate in attic. Z-) xz'7 - Approved . . . . . ficial VOID UNLESS SIGNED BY BUILDING OFFICIAL PREPARED 4/14/08, 8:07:16 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/11/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 2081 RAVENSTONE LOOP SUBDIV: CASTLEGATE SEC 1 PH 1 CONTRACTOR KEITH DOWNS CUSTOM HOMES PHONE (936) 597-4871 OWNER GREENS PRAIRIE INVESTORS LTD PHONE PARCEL 184200-1102-0060 APPL NUMBER: 07-00001563 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 1/02/08 BI BLDG, FOUNDATION -SLAB TIME: 17:00 1/02/08 CA January 2, 2008 8:59:38 AM acarter. B100 02 1/03/08 RH BLDG, FOUNDATION -SLAB TIME: 17:00 1/03/08 DP January 2, 2008 4:42:53 PM kwolfe. 01/03/2008 10:36 AM RH PDA Need slab ground and clean dirt out of beams. B100 03 1/08/08 RH BLDG, FOUNDATION -SLAB TIME: 17:00 1/08/08 AP January 8, 2008 8:07:24 AM glsouth. 01/08/2008 09:45 AM RH PDA Slab survey on file. Slab ground installed. B115 01 2/15/08 RH BLDG, FRAMING TIME: 17:00 2/15/08 AE February 13, 2008 8:05:19 AM glsouth. Add bolts for braced wall. Sheetrock fireplace. Bond gas pipe. Tape seal doors & penetrations through tyvek. B130 01 2/21/08 OC BLDG, INSULATION TIME: 17:00 _ 2/21/08 AP February 21, 2008 7:56:22 AM kwolfe. B125 01 4/11/08 B�I �g BLDG, FINAL TIME: 17:00 r['ri April 11, 2008 3:23:54 PM glsouth. -------------------------------------- COMMENTS AND NOTES -------------------------------------- IL C-0> "i0 "t7:.)M-7- ADUESS 1JWGC. d ►Fbs'( CC 9fF_. F-j 4TT'LC . S4Zk-CCr.,15,�, ' "L-AJSTafL40C' . ` Amber Carter - Re: Calling for C.O. @'2081 Raventsone Loop _ 1 From: Paul Schoenfeld To: Amber Carter; Benjamin McCarty; Chris Haver; ... Date: 4/14/2008 10:57:57 am Subject: Re: Calling for C.O. @ 2081 Raventsone Loop NO for CO. Water and Sewer both need to be raised to grade. Paul >>> Gina Southerland 4/14/2008 8:25 AM >>> BP# 07-1563 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.cstx.gov TRANSMISSION VERIFICATION REPORT DATE J I ME FAX NO./NAME DURATION PAGE(S) RESULT MODE TIME 04/11/2008 15:36 NAME FAX TEL SER.# 000L5J596800 04/11 15:36 919365974459--63801# 00: 00: 19 01 OK STANDARD ECM Energy Code Compliance Information % Glazing of exterior walls 1 Zf Q Insulation R value of exterior walls 1-5 Insulation R value of ceiling 1 (fat areas) 0 Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC 4 q0 Glazing U-Factor r /7 S R value of ductwork f A/C SEER Rating / 3 XO 97 . #f - \'OM,gc j O W E W Viki �IPi��c LOT 4 BLOCK 2 R=6BO.00' D=06.07'53" ------- L=72.77' LC=72.73' CB=S 88'41'57" E t jt��M— 7-So' 8T 6CK 2co LOT 5BLOCK 2 UNDATION FORM SPACE nICLOP£N (PLAT)'ec ErisEld£m File same: 073MDNG Plot dale: 12/19/07 at 11:13 1 SAD' U.E. 04ry 7.6e C51 LOT 7 BLOCK 2 N` (CAUM N BB'28'29' yr 6: N 88'23'24" W 85.16' 1RAvl:�SJ ° o w -OOP CITY OF COLLEGE STATION CITY PARK (PLAT) LOT 8 BLOCK 2 SURVEY LEGEND SEtWECT ,,,aaERTY iffl E <' Et.ECIN,YSIL [aye ® WA M? UETER —ss— B4RDWE PEACE ® E2WnW AfMR — — EVLVN46E E 24MV T i PORW PCA'E —' — — RA2VJrR.CA1 EASEUENT .ss. > FaWAM .— — — — VIAAY EASEaft7rr 0 G4s EIE7ER PAIpaz TANK RESTRA:7m BtmfINNG LM SEPAIC T.WK to 5/9' &%W RW ►OUM 19 AW RW SET M 7E2D:Y a PEDEYM Survey Nowt 1). The basis of this survey Is Pan rods found In Block Two (2), as recorded In Volume 4354. Page 164 of the IMO.R. 2). Droving Scde Is 1'"30' 3). Technician: Jason Ballet', Fled Crew: J.A. & R,R, 2 Sold lot does not appear to be under the 100 year rood plan, as enlS..d byy the Federal Finergeney Management Agency an Communlly Panel N. 4CD41D0205 D. Dated: February 9, 2OW 1, Dante Corlomagno, Regirtered Profesallond Land Surwyor No. 1562, do hereby certily that the above survey Is a true and accurate representation of an actual on the ground survey mode under my supervision and that there are no encroachments or overlaps unless otherwise shoeT, �G OF 1562 Land Surveyor, Number 1552 " $ 19� PLAT OF SURVEY LOT no.: SIX (8) BLOCK No- TWO (2) su6omsioN: CASTLEGATE SUBDIVISION, SECTION 1, PHASE 1 STREET IDDRtSS: 2061 RAVENSTONE LOOP 4354/164 CITY. COLLEGE STATION cmwrY: BRAZOS suRnYtD FOR: KEITH DOWNS CUSTOM HOMES • "u" SLMWY WlS 00WP=W &MOA TeC e0101111' OF A mla aaraazva. Carlomagno Surveying, Inc. 2714 Finfeother Rood, Bryan, Texas 77801 PHONE: (979)775-2873 FAX: (979)775-4787 WtVW.CarIomciunoSu vevinn.eam 6r7-)s-&s Oe7,)S-&,S May 31, 2007 GEOTECHNICAL ENGINEERING STUDY Proposed Downs Residence 2081 Ravenstone Loop Castlegate Subdivision College Station, Texas Prepared for: Ms. Stacy Downs College Station, Texas Prepared by: GESSNER ENGINEERING College Station, Texas Gessner Engineering Job No. 07-0177 Gessner Engineering OF TE, / 5 •s **;LT G. QGERS o°. 80833 •� Q May 31, 2007 13. Ms. Stacy Downs Gessner 2081 Ravenstone Loop Engineering College Station, Texas Zip Re: Geotechnical Engineering Study Proposed Downs Residence 2081 Ravenstone Loop College Station, Texas 77845 Gessner Engineering Job No.: 07-0177 Dear Ms. Downs: This report conveys our geotechnical engineering study conducted for the proposed Downs residence located in College Station. We trust that this report is responsive to your project needs. Please contact us if you have any questions or if we can be of further assistance. We appreciate the opportunity to work with you on this phase of the project, and look forward to the opportunity to provide additional geotechnical engineering services, structural services, and construction materials testing services as the project progresses. Sincerely, GESSNER ENGINEERING Alton . ogers, k� ��„��a•E OF TF • i • • • 1s • AL:ON G. ROG 9RS•• P.E. p".. 50833 a e¢ a AL Copies Submitted: Ms. Stacy Downs (3) P Ay-�� Amanda Blackburn 1712 Southwest Parkway, Suite #105, College Station, Texas 77840 • P.O. Box 10763, 77842-0763 • 979.680.8840 • FAX 979.680.8811_ 2204 South Chappell Hill Street, Brenham, Texas 77833 • 979.836.6855 • FAX 979.836.6847 www.GessnerEngmeering.com Table of Contents Tableof Contents..............................................................................................................3 Introduction........................................................................................................................4 ProjectDescription...........................................................................................................4 Scopeof Services.............................................................................................................4 Site Investigation Procedures.........................................................................................5 LaboratoryTesting............................................................................................................6 SampleDisposal................................................................................................................6 SiteConditions..................................................................................................................6 SiteGeology.....................................................................................................................................6 SurfaceConditions........................................................................................................................... 6 SubsurfaceConditions..................................................................................................................... 7 Groundwater Conditions................................................................................................................... 7 Engineering Recommendations.....................................................................................8 Slab -on -Grade Foundation System..................................................................................................9 PierRecommendations..................................................................................................................10 PTIParameters...............................................................................................................................11 Foundation Construction................................................................................................................ I I Foundation Construction Monitoring ........................................................................................11 Earthwork........................................................................................................................................12 Drainage.........................................................................................................................................13 GeneralComments.........................................................................................................13 Limitations........................................................................................................................14 Appendix..........................................................................................................................15 Gessner Engineering -3- Introduction This report presents the results of our geotechnical engineering study for the proposed Downs residence, located in College Station. Gessner Engineering was selected to provide the subsurface investigation and report for this project. Project Description The project consists of the proposed construction of a Downs residence at the site located in 2081 Ravenstone Loop of the Castlegate Subdivision in College Station. Scope of Services In Recommended Practice for the Design of Residential Foundations, the Texas Section of the American Society of Civil Engineers defines an engineered foundation as one that includes a geotechnical engineering investigation. To act as this first phase of an engineered foundation, our scope of work for this project consisted of: 1. Drilling one (1) test bore hole at the selected location within the project site to evaluate the subsurface arrangement of strata and groundwater conditions. 2. Performing geotechnical laboratory tests on recovered samples to evaluate the physical and engineering properties of the strata observed. 3. Engineering analysis to develop design and construction recommendations with respect to. - Site, subgrade, and fill preparation, and • Foundation design and construction. Gessner Engineering Location: -Brazos County -4- Site Investigation Procedures Subsurface conditions were evaluated by drilling one (1) test bore hole on May 10, 2007 to a depth of approximately fifteen (15) feet ten (10) inches below the Bore Hole: existing ground surface (at the time of our field activities) within the limits of the - I Bore Hole proposed Downs residence. The bore hole was located at the approximate center - Depth 15°10" of the proposed residence about forty (40) feet from Ravenstone Loop Street. The bore hole was drilled using trailer -mounted drilling equipment. The Log of Bore Hole, presenting the subsurface soil descriptions, type of sampling used, and additional field data, is presented on the bore hole log provided in the Appendix. The Symbol Key Sheet, which defines the terms and descriptive symbols used on the log, is also provided in the Appendix. Soil samples were generally recovered using thin -walled, open -tube samplers (Shelby tubes). Pocket penetrometer tests were performed on samples of cohesive soils in the field to serve as a general measure of consistency and to give a relative measure of the strength of the sample. The term consistency refers to the degree of adhesion between the soil particles and to the resistance offered against forces that tend to deform or rupture the soil aggregate. The consistency of clays and other cohesive soils is usually described as very soft, soft, firm, stiff, very stiff, and hard. The correlation between the pocket penetrometer results and these consistency terms are provided on the Figure, Symbols and Terms used on the Bore Hole Log in the Appendix. Additional consistency terms used on cohesive soils are plastic, lean and fat. The more closely a soil approaches the characteristics of a clay soil, the greater the variety of states of consistency in which it may be found. A plastic soil changes physical properties depending upon the moisture content of the soil. The degree of plasticity is sometimes expressed by the terms fat and lean. Lean sandy clay is only slightly plastic and typically contains a higher percentage of sand or silt. Fat clay has a higher percentage of clay. Samples of soil for which a good quality thin -walled tube sample could not be recovered were obtained by means of the Standard Penetration Test (SPT). This test consists of measuring the number of blows required for a 140-pound hammer free falling thirty (30) inches to drive a standard split -spoon sampler twelve (12) inches into the subsurface material after being seated six (6) inches. This blow count or SPT "N" value is used to evaluate the engineering properties of the stratum. Correlations between the unconfined compressive strength and the standard penetration number for the in situ soils have been developed to estimate the bearing capacity of the soils. The most direct qualitative measure of consistency is the load per unit area at Gessner Engineering -5. which unconfined samples of the soil fail in a simple compression test. This quantity is known as the unconfined compressive strength of the soil. The shear strength of cohesive soils can be estimated based upon the unconfined compressive strength of the soil. All samples were removed from samplers in the field, visually classified, and appropriately sealed in sample containers to preserve their in situ moisture contents. Laboratory Testing Samples obtained during the field program were visually classified in the laboratory by a geotechnical engineer or technician. A testing program was conducted on selected samples in accordance with the ASTM Standard Test Tes ti -ASTMTM Standard Procedures, as directed by the geotechnical engineer, to aid in classification and evaluation of engineering properties required for analysis. Results of the laboratory tests are presented on the Log of Bore Hole in the Appendix and are discussed in the following section. Sample Disposal All samples were returned to our laboratory in Brenham, Texas. Samples not tested in the laboratory will be stored for a period of thirty (30) days subsequent to submittal of this report and will be discarded after this period, unless Gessner Engineering is notified otherwise. Site Conditions Site Geology The site is located in the Wellborn Formation of the Eocene Age in the Tertiary Era as indicated on the Geologic Atlas of Texas, Austin Sheet as published by the Formation: University of Texas at Austin. The Wellborn Formation is composed of clay and -wenbom on sandstone. The clay is lignitic, chocolate in color and has interbedded fine to Austin Sheet medium grained sand. The sandstone is medium grained, forms ledges, indurated, locally silica cemented, and light gray in color. The thickness of the Wellborn Formation is in excess of 150 feet. Surface Conditions Based on visual observations, the area of the proposed Downs residence is located on a gentle slope with an elevation difference of approximately two (2) feet across the site. Ground cover for the proposed site consists of heavy grass and is partially wooded. The site for the proposed residence location is within an existing subdivision. Gessner Engineering -6- Surface: 2' Elevation Change Figure 2: Proposed Site Surface Condition Subsurface Conditions The generalized subsurface arrangement of strata at the site, as evaluated from Classification: our field and laboratory programs, generally consists of high plasticity clay to sandy soils. In Bore Hole One, very stiff to hard gray silty clay was noted at the existing ground surface. Hard sandstone with some clay layers was noted at two (2) feet below the existing ground surface. Very stiff tan and light gray silty fine sand -Bore Hole �: was noted at four (4) feet below the existing ground surface. Very stiff light gray Silty Clay and Clayey silty fine sand with some clay layers was noted at six (6) feet below the existing Sand ground surface. Very stiff light gray and tan silty fine clayey sand with iron seams was noted at eight (8) feet below the existing ground surface. Hard light gray clay and brown silty sandy clay with iron seams was noted at thirteen (13) feet and continued to the termination of the bore hole at fifteen (15) feet ten (10) inches. These soils generally exhibit a high to moderate potential for volumetric change due to moisture variations, as indicated by measured plasticity indices of thirty- three (33) to twenty-five (25). In situ moisture contents ranged from zero (0) to seven (7) percent wet of the corresponding plastic limits. This indicates that the soils were moist at the time of sampling. During the procurement of subsurface samples, pocket penetrometer tests were performed upon each soil sample retrieved with a Shelby tube. Groundwater Conditions The bore hole was dry augered to its completed depth in an attempt to observe groundwater conditions. No groundwater was observed in the bore hole at the time of drilling. We should note that groundwater at the site may occur in the form of "perched" water traveling along pervious seams or layers in the soils noted below two (2) feet. The frequency of such groundwater is expected to increase during and soon after periods of wet weather. A geotechnical engineer Gessner Engineering should be notified if water is encountered during construction. Engineering Recommendations The following recommendations are based upon the data obtained in our field and laboratory programs, information provided to Gessner Engineering by the client, and our experience with similar subsurface and site conditions and the proposed construction methods. Moderately expansive clay and sandy soils are present on this site. This report provides recommendations to help mitigate the effects of soil shrinkage and expansion. However, even if these procedures are followed, some movement and cracking in the structure should be anticipated. The potential for material cracking and other damage such as unlevel floor slabs will increase if modifications at the site during or after construction results in excessive wetting or drying of the expansive soils. Eliminating the risk of movement and distress may not be feasible, but it may be possible to further reduce the risk of movement if significantly more expensive measures are used during construction. We would be pleased to discuss other construction alternatives with you upon request. There are four (4) types of concrete foundations typically used to design for expansive soils: Option 1: A structural slab isolates the foundation from the soils through the use of cardboard forms or a crawl space. Similar separation can be accomplished with a traditional wooden pier and beam system. Option 2: A stiffened slab -on -grade, also known as a waffle slab, consists of a slab stiffened with beams spanning across the foundation in each direction. Option 3: A stiffened slab -on -grade can be supported on piers to help reduce structural risks associated with expansive soils, especially when the foundation will carry large concentrated loads. Piers should be isolated from a slab -on -grade foundation to avoid cracking from uplift pressure. Option 4: A post tensioned slab consists of a reinforced "ribbed" slab with stiffening beams in both directions and steel cables placed in tension after the slab is in place. Deciding the type of foundation system is a process that should involve the owner, architect, contractor/builder, and engineer. It is the opinion of Gessner Engineering that a structural slab is the best type of foundation to design for Foundation: highly expansive soils. Because a structural slab is very expensive and this site -Stiffened contains moderate expansive soil with a significant amount of sand, a structural Slab -on -Grade slab is not necessary for this project. Based on the field and laboratory data (Option 2) available, along with our previous experience, a stiffened slab -on -grade Gessner Engineering -8- foundation system (Option 2) is recommended by Gessner Engineering to support the proposed Downs residence provided the subgrade is prepared as stated below. Piers are not anticipated at this site. This system is optimal because it is economical for the type and scale of this project while still maintaining a low risk of damage from movement if properly designed. Recommendations for a slab -on - grade foundation system are presented in the following subsections, along with other geotechnical engineering considerations for this project. The final decision and responsibility is to be made by the owner based on the recommendations provided. It is the opinion of Gessner Engineering that a stiffened slab -on -grade (Option 2) is advantageous over the three (3) remaining types of foundations mentioned above. While a structural slab (Option 1) provides the best protection from soil movement, the materials and labor required make this type of foundation significantly more expensive and are most often not feasible for projects of this scale. Piers (Option 3) are not necessary for soils of moderate expansion potential like those found on this site, and while post tensioned slabs (Option 4) are generally the least expensive option, it is Gessner Engineering's opinion that this type of foundation is less reliable and does not adequately address the expansive potential of the onsite soil conditions and potential deflection from that expansion. Slab -on -Grade Foundation System (Option 2) Our primary foundation recommendation to support the proposed structure is a slab and grade beam foundation system. Presented below are the design parameters for the Building Research Advisory Board (B.R.A.B.) design method and the Wire Reinforcement Institute (W.R.I.) design method based upon the subsurface conditions observed at this project location. These design parameters are based on criteria published by the Building Research Advisory Board (B.R.A.B.) and the Wire Reinforcement Institute (W.R.I.). These methods are essentially empirical design techniques and the parameters provided are based on our interpretation of the project soil bore hole(s) and criteria published in the B.R.A.B. design manual and the W.R.I. design manual. Based on the existing soil, the effective plasticity index is calculated at thirty- three (33) which indicates a moderate expansion potential. Gessner Existing Engineering recommends a minimum of six (6) inches of the existing surficial soil surface be removed and replaced with a minimum of eighteen (18) inches of select fill Conditions: compacted in place to construct a level building pad. The exposed soil subgrade -Clay lady soils nd shall be proof rolled and all soft areas removed and replaced as directed by the geotechnical engineer prior to the placement of any fill material. A value of 3,000 pounds per square foot (psf) may be used as the resulting allowable Gessner Engineering -9- bearing pressure for the soils at one (1) to three (3) feet below ground surface once the building pad is in place. Other measures recommended to reduce moisture infiltration into the subgrade are presented later in this subsection and in the "Drainage" subsection. The effective design parameters after the removing and replacing of select fill are presented in the table below (Table 1). Effective Design Plasticity Index (PI) 33 Climatic Rating (CH,) 20 Soil Support Index (C) 0.84 Bearing Pressure 3,000 psf Table 1: Effective Design Parameters Gessner Engineering has calculated the potential vertical rise (PVR) of this site using the Texas State Department of Highways and Public Transportation method TEX 124-E. The PVR assuming dry in situ soils being hydrated to a fully saturated state at this site is equal to 2.34 inches. This value is calculated using the current moisture conditions and does not take into consideration weather variances or the moisture content at the time of construction. Due to assumptions and generalities required for the calculation of the potential vertical rise, it should only be taken as an approximation. We should note that moisture variations in the subgrade soils due to poor drainage, leakage of utilities, etc. could induce volumetric changes resulting in movements which are in excess of those estimated by the PVR procedure. We recommend that grade beams extend at least twelve (12) inches below final grade into properly compacted earth. This recommendation is to reduce surface water migration below the foundation elements and to develop proper end bearing and is not based on structural considerations. The grade beam width and depth should be properly evaluated by the structural engineer. Grade beams may be thickened and widened at column locations to serve as spread footings at these concentrated load areas. Based on the allowable bearing capacity calculated by Gessner Engineering, the amount of total and differential settlement of the proposed site is anticipated to be minimal if the design requirements are precisely followed as stated in this report. For a slab -on -grade foundation, we highly recommend that measures be taken whenever practical to increase the tolerance of the proposed Downs residence to post -construction foundation movements. An example of such measures would be to provide frequent control joints for masonry/brick/stucco veneer exteriors, if any, to control cracking across such walls and concentrate movement along the joints. Pier Recommendations Based on information from the soils investigated, Gessner Engineering does not anticipate that drilled piers are required to support a stiffened slab foundation. Gessner Engineering Design: -PI = 33 -BC =3, 000 psf -Remove 6" Replace 18" Of Select Fill PVR = 2.34 -10- However, if concentrated loads in excess of fifteen thousand (15,000) pounds are anticipated, or if the client so desires, the stiffened slab foundation may be supported on straight shaft piers. The piers shall be designed for an allowable bearing capacity of 9,000 psf based on total load and an allowable bearing capacity of 6,000 psf based on dead load only. The piers shall be supported in light gray sandy clay soil at a depth of thirteen (13) feet below the existing ground surface. For monolithically poured foundation slabs, the drilled piers should be isolated from the grade beams. Piers must be poured the same day they are drilled. Pier shafts shall not be left open overnight. Piers that are unable to be poured on the same day as they are drilled shall be backfilled as per the geotechnical engineer's recommendations. PTI Parameters A post -tensioned slab design is commonly used to support residences. However, Gessner Engineering encourages the use of a conventionally reinforced stiffened slab. Based upon experience, conventionally reinforced stiffened slabs have proven to be more reliable in resisting deflections which lead to cracking of finishes. However, the Post -Tensioned Institute (PTI) parameters are given below should the designer prefer to use a post -tensioned slab or design method: Thomthwaite 5 Soil Suction 3.4 Edge Moisture Variation Distance -em Center Lift = 4.9 ft Edge Lift = 4.6 ft Differential Soil Movement - ym Center Lift = 0.930 in Edge Lift = 0.589 in Subgrade Friction Coefficient - N: 0.75 Allowable Bearing Pressure: 3,000 psf Table 2: Post Tension Design Parameters Foundation Construction Grade beams for the slab -on -grade foundation system should be neatly excavated, if possible. If neat excavation is not possible, the foundation should be properly formed. If a toothed bucket is used, excavation with this bucket should be stopped six (6) inches above final grade and the footing excavation completed with a smooth -mouthed bucket or by hand labor. Debris in the bottom of the excavation should be removed prior to steel placement. The foundation excavation should be sloped sufficiently to create internal sumps for runoff collection and removal. If surface runoff water or groundwater seepage in excess of one (1) inch accumulates at the bottom of the foundation excavation, the geotechnical engineer shall be contacted for'recommend ations. Foundation Construction Monitoring The performance of the foundation system for the proposed Downs residence Gessner Engineering Piers: -Not Required for typical slab - Straight Shaft -13' Depth -BC =9, 000 psf total and 6, 000 psf dead -11- will be highly dependent upon the quality of construction. Thus, we recommend that the foundation installation be monitored by Gessner Engineering to identify the proper bearing strata and depths and to help evaluate foundation construction. We would be pleased to develop a plan for foundation monitoring to be incorporated in the overall quality control program. Please contact Gessner Engineering for more information. Earthwork Construction areas should be stripped of all vegetation, loose topsoil, surficial concrete, etc. Roots of trees to be removed within construction areas should be excavated and removed from the construction area. Once final subgrade elevation has been achieved, exposed soil subgrade areas shall be proofrolled with a fifteen (15) ton roller (minimum) or equivalent equipment as approved by the engineer to detect weak zones. Weak areas detected during the proofrolling process, as well as zones containing debris and/or organics and voids resulting from removal of tree roots, etc., should be removed and replaced with soils exhibiting similar classification, moisture content, and density as the adjacent in situ soils. Proper site drainage should be maintained during construction so that ponding of surface runoff does not occur and cause construction delays and/or inhibit site access. Please note that subgrade preparation specific to the Downs residence foundation is located in the section of this report which addresses that topic. The above subgrade preparation refers to general site preparation only. Select fill to be utilized within the proposed Downs residence limits should consist of a low plasticity clayey soil with a plasticity index between five (5) and twenty (20), a maximum gravel content (percentage retained on No. 4 sieve) of forty (40) percent, and rocks no larger than two (2) inches in their largest dimension or a crushed limestone base material meeting the requirements of the Texas Department of Transportation (TxDOT) 1993 Standard Specifications Item 247, Type A, Grade 4. Alternatively, a low -plasticity granular fill material which does not meet these specifications may be utilized only if approved by Gessner Engineering. All structural fill should be placed on prepared surfaces in lifts not to exceed eight (8) inches loose measure, with compacted thickness not to exceed six (6) inches. Select fill should be compacted to at least ninety-five (95) percent of the Standard Proctor (ASTM D 698) density at a moisture content ranging within two (2) percent of optimum moisture content for depths of three (3) feet or less. If fill in excess of three (3) feet is required, all structural and select fill deeper than three (3) feet shall be compacted to ninety five (95) percent of Modified Proctor Density (ASTM D 1557). Four different methods may be utilized to successfully compact the soil. They include the processes of static weight, kneading action, impact, or vibration. The soil must be compacted using a compactor in accordance with the ASTM standards. A compactor is required to compact the soil to such a large degree. Track equipment such as bull dozers apply pressure across a large surface area and are therefore limited Gessner Engineering Contact Gessner Engineering for Quality Control Monitoring Select Fill: -5 < PI < 20 -Max 40% Gravel -Rocks smaller than 2" Compaction: -95% Standard Proctor -Within 2% optimum moisture -Compactor required -12- in their capabilities compared to a compactor. If the select fill is not compacted properly, the fill material and structures constructed on it are subject to significant settlement. Drainage The performance of the foundation system for the proposed Downs residence will not only be dependent upon the quality of construction, but also upon the stability of the moisture content of the near surface soils. Therefore, Gessner Engineering highly recommends that site drainage be developed so that ponding of surface runoff near the structure does not occur. Accumulation of water near the structure foundation may cause significant moisture variations in the soils Adiacentto Structure: adjacent to the foundation, thus increasing the potential for structural distress. -Pt < 30 Special care should be taken to insure that underground utilities do not develop -5% slope min leaks with time. Post construction expansion of the clayey soils placed around the exterior of a Downs residence for final grading can cause a condition to arise in which moisture becomes trapped against the structure. Therefore, it is imperative that proper grading around the structure with suitable materials be used to avoid this condition. General fill for final grading adjacent to and extending five (5) feet beyond the foundation shall have a Plasticity Index of thirty (30) or less. The upper portion of utility excavations should be backfilled with properly compacted clay soils to minimize infiltration of surface water. A clay "plug" should be provided in the trench on the exterior of the building to prevent water from gaining access along the trench to the subgrade beneath the structure. A minimum of five (5) percent slope is recommended within the first ten (10) feet of the proposed structure. General Comments The American Society of Civil Engineers recommends that an engineer should perform observations and testing during excavation grading, foundation, and construction phases of the project in Recommended Practice for the Design of Residential Foundations. Gessner Engineering would be pleased to provide foundation design review, foundation inspection prior to the concrete pour, and construction materials testing. The analysis and recommendations presented in this report are based upon the data obtained from the boring performed at the indicated location and from other information discussed in this report. This report does not reflect variations that may occur across the site or due to the modifying effects of weather. The nature and extent of such variations may not become evident until during or after construction. If variations appear, Gessner Engineering should be immediately notified so that further evaluation and supplemental recommendations can be provided. Gessner Engineering aMe I imitatinm The scope of services for this project does not include, either specifically or by implication, any environmental or biological (e.g., mold, fungi, bacteria) assessment of the site or identification or prevention of pollutants, hazardous materials, or conditions. If the owner is concerned about the potential for such contamination or pollution, other studies should be undertaken. For any excavation construction activities at this site, all Occupational Safety and Health Administration (OSHA) guidelines and directives should be followed by the Contractor during construction to insure a safe working environment. In regards to worker safety, OSHA Safety and Health Standards require the protection of workers from excavation instability in trench situations. This report has been prepared for the exclusive use of Ms. Stacy Downs for the specific application to the project discussed and has been prepared in accordance with generally accepted geotechnical engineering practices. This report was written and recommendations were made based on the soil data collected on May 10, 2007. If construction is delayed or the proposed area experiences severe weather conditions please contact the geotechnical engineer prior to construction. No warranties, either expressed or implied, are intended or made. In the event that changes in the nature, design, or location of the project as outlined in this report are planned, the conclusions and recommendations contained in this report shall not be considered valid unless Gessner Engineering reviews the changes and either verifies or modifies the conclusions of this report in writing. Gessner Engineering SEE Appendix Recommendations Summary Log of Boring Symbol Key Sheet Glossary of Geological Terms Gessner Engineering -15- RECOMMENDATIONS SUMMARY*** Foundation Type o stiffened slab -on -grade Design Parameters o effective plasticity index (PI) equals 32 o climatic rating of twenty (20) o support index of 0.84 Subgrade Preparation o remove a minimum of six (6) inches of surficial soils o replace with a minimum of eighteen (18) inches of compacted select fill Grade Beams and Footings o subgrade bearing capacity of 3,000 pounds per square foot (psf) o grade beams and footings one (1) to three (3) feet below finished grade Piers o not anticipated unless concentrated loads exceed 15,000 pounds ***It should be noted that this summary simply outlines the recommendations made in the geotechnical engineering report. This summary is not intended to replace or supersede any part of these recommendations. The report shall be used for all design and construction procedures. Gessner Engineering LOG OF BORE HOLE PROJECT: Lot 6, Block 2 BORING NO. #1 2081 Ravenstone Loop LOCATION: Approx Center of House College Station, Texas CLIENT: Stacy Downs BORING TYPE: Core/Auger DATE: 05-10-07 DRILLER: Gessner Engineering SOIL TECHNICIAN: KN GROUND ELEV: Flat Heavy Grass Partially Wooded �^ a a E n° E °' co> rn ° 3 - : a C-o ) o 3 ,�, o pq ao .d o a ° °" a v ., a °p v w c m �� Q -a > y[ a' 0~' Mr. O L. a °"o L' m E- Coring Sample 0 Shelby Tube Sample Standard Penetration Test Sample Augering (Disturbed) Sample ® No Recovery p Initial Water Level ♦ Water Level After Description of Stratum 3.0 4.5+ 50 33 23.17 -- -- Very Stiff to Hard Gray Silty Clay (CH) 5.0 Hard Sandstone —w/ Clay layers 5 7/6/I1 Very Stiff Tan & Lt Gray Silty Fine Sand (SM-SP) 7/9/15 8/13/16 45/39/39 38 25 12.50 -- -- Very Stiff Gray Silty Fine Sand (SM-SP) -w/ Clay layers Very Stiff Lt Gray & Tan Silty Fine Clayey Sand(SC -w/ Iron Seams Hard Lt Gray Silty Sandy Clay (CL) —w/ Iron Seams 1 0 1 5 TERMINATED AT 15'10" Dry at completion 20 25 2204 South Chappell Hill Street Brenham, Texas 77834 (979) 836-6855 P.O. Box 10763 College Station, Texas 77842 (979) 680-8840 Gessner Engineering SYMBOLS AND TERMS USED ON BORING LOGS CLAY SILT SAND SANDSTONE GRAVEL ® ® E D LIMESTONE FILL ASPHALT CONCRETE SHALE SAMPLER TYPES 0 J AUGER SHELBY TUBE rWffl SAMPLE LOST SPLIT SPOON TERMS DESCRIBING CONSISTENCY OR CONDITION COARSE GRAINED SOILS (Major Portion Retained on No.200 Sieve): Includes (1) clean gravels and sands, and (2) silty or clayey gravels and sands. Condition is rated according to relative density, as determined by laboratory tests. Standard Penetration, N-Value, Blows/Ft. Relative Density 0-4 Very Loose 4-10 Loose 10-30 Medium Dense 30-50 Dense >50 Very Dense FINE GRAINED SOILS (Major Portion Passing No.200 Sieve): Includes (1) inorganic and organic silts and clays, (2) gravelly, sandy, or silty clays, and (3) clayey silts. Consistency is rated according to shearing strength, as indicated by penetrometer readings or by unconfined compression tests. Standard Penetration, N-Value, Blows/Ft. Consistency 0-2 Very Soft 2-4 Soft 4-8 Firm 8-15 Stiff 15-30 Very Stiff >30 Hard Unconfined Compressive Strenqth, tons/sq. ft. less than 0.25 0.25 to 0.50 0.50 to 1.00 1.00 to 2.00 2.00 to 4.00 4.00 and higher Note Slickensided and fissured clays may have lower unconfined compressive strengths than shown above, because of planes of weakness or cracks in the soil. EXPANSION POTENTIAL OF COHESIVE SOILS Plasticity Index Degree of Expansive Potential 0-5 Very Low 5-20 Low 20-30 Moderate 30-40 High >40 Very High TERMS CHARACTERIZING SOIL STRUCTURE Parting - paper thin in size Seam - 1/8" to 3/8" thick Layer- greater than 3" Slickensided - having inclined planes of weakness that are slick and glossy in appearance Fissured - containing shrinkage cracks, frequently filled with fine sand or silt; usually more or less vertical. Laminated - composed of thin layers of varying color and texture Interbedded - composed of alternate layers of different soil types Calcareous - containing appreciable quantities of calcium carbonate Well graded - having wide range in grain sizes and substantial amounts of all intermediate particle sizes Poorly graded - predominantly of one grain size, or having a range of sizes with some intermediate size missing Flocculated - pertaining to cohesive slils that exhibit a loose knit or flakey structure Gessner Engineering GLOSSARY OF GEOLOGIC TERMS Aphanitic - dense, homogeneous rock with constituents so fine that they cannot be seen by the naked eye Argillaceous - containing, made of, or resembling clay; clayey Bentonitic - an absorbent aluminum silicate clay formed from volcanic ash and used in various adhesives, cements, and ceramic fillers Carbonaceous - consisting of, containing, relating to, or yielding carbon Chert - a siliceous rock of chalcedonic or opaline silica occurring in limestone Conchoidal - of, relating to, or being a surface characterized by smooth, shell-like convexities and concavities, as on fractured obsidian Crossbedded - intersecting layers of distinct soil deposits Fluviatile - produced by the action of a river or stream Fossiliferous - containing fossils Friable - readily crumbled, brittle Glauconitic - a greenish mineral of the mica group, a hydrous silicate of potassium, iron, aluminum, or magnesium found in greensand and used as a fertilizer and water softener Gypsiferous - containing gypsum; a widespread colorless, white, or yellowish mineral, used in the manufacture of various plaster products, and fertilizers Igneous - rocks formed by solidification from a molten state; pyrogenic Inclusion - a solid, liquid, or gaseous foreign body enclosed in a mineral or rock. Indurated - hardened soil that has been changed by extreme climate Laminated - a soil deposit divided into thin layers Lateritic - pertaining to red residual soil in humid tropical and subtropical regions that is leached of soluble minerals, aluminum hydroxides, and silica but still contains concentrations of iron oxides and iron hydroxides. Lenticular - lens -shaped grains of soil or rock Lignitic - pertaining to soft, brownish -black coal in which the alteration of vegetable matter has proceeded further than in peat but not as far as in bituminous coal; also called brown coal Marl - a loose and crumbling earthy deposit consisting mainly of calcite or dolomite; used as a fertilizer for soils deficient in lime Metamorphic - rocks changed in structure or composition as a result of metamorphism caused by chemical reaction or heat and pressure Micaceous - containing mica; any of a group of chemically and physically related aluminum silicate minerals, common in igneous and metamorphic rocks, characteristically splitting into flexible sheets used in insulation and electrical equipment Montmorillonitic - clays that are comprised mostly of montmorillonite; one of the three types of clay soil grains (illite, kaolinite, and montmorillonite) Morphology - refers to the geological characteristics, configuration, and evolution of rocks and land forms Porous - admitting the passage of gas or liquid through pores or interstices Pyrite - a brass -colored mineral occurring widely and used as an iron ore and in producing sulfur dioxide for sulfuric acid; also called fool's gold Scarp - a long steep slope or cliff at the edge of a plateau or ridge; usually formed by erosion Siliceous - containing, resembling, relating to, or consisting of silica; a white or colorless crystalline compound occurring abundantly as quartz, sand, flint, agate, and many other minerals and used to manufacture a wide variety of materials, especially glass and concrete Surficial - of, relating to, or occurring on or near the surface of the earth Tuffaceous - comprising rocks made of compacted volcanic ash varying in size from fine sand to coarse gravel; also called tufa Gessner Engineering STRUCTURAL ENGINEERING Steel • Cast in Place Concrete • Concrete Tilt Wall • Timber Foundation Design • Structural Inspections GEOTECHNICAL ENGINEERING Soil Sampling • Geotechnical Investigations CIVIL ENGINEERING Subdivision Layout and Design • Site Development Stormwater Pollution Prevention Plans • Municipal Compliance Pavement Design • Drainage Analysis CONSTRUCTION MATERIALS TESTING Soil Testing • Concrete Testing • Pier Monitoring Construction Monitoring and Inspections LEGAL SUPPORT AND EXPERT TESTIMONY ENVIRONMENTAL SITE ASSESMENTS 12 Southwest Parkway, Suite #105, College Station, Texas 77840 • P.O. Box 10763, 77842-0763 • 979.680.8840 • FAX 979.680.8841 2204 South Chappell Hill Street, Brenham, Texas 77833 - 979.836.6855 • FAX 979.836.6847 www.GessnerEngineering.com T CITY OF COLLEGE STATION 110 L.XE.Y-kS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00001563 Date 5/29/07 Application pin number . . . 584886 Property Address . . . . . . 2081 RAVENSTONE LOOP Property ID: 184200-1102-0060 R #: R109198 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE SEC 1 PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 158400 Owner ------------------------ Contractor ------------------------ GREENS PRAIRIE INVESTORS LTD KEITH DOWNS CUSTOM HOMES 4490 CASTLEGATE DR 602 OLD PLANTERSVILLE RD. COLLEGE STATION TX 778453388 MONTGOMERY TX 77316 (936) 597-4871 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID N/A FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2400.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC ---------------------------------------------------------------------------- TAZ 441.00 Permit BUILDING PERMIT Additional desc MA Permit pin number 505008 Permit Fee . . . . 637.00 Plan Check Fee .00 Issue Date . . . . 5/29/07 Valuation . . . . 158400 Expiration Date . . 11/25/07 Qty Unit Charge Per Extension BASE FEE 460.00 59.00 3.0000 THOU BLDG, VAL 100001-500000 177.00 ----------------------------------------------------------------------- Special Notes and Comments Narrow Wall Bracing Fully Sheathed with Relocated Interior Garage Wall per Plans and Anchors and Bracing for Front Door - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - r- - - - - - - - - - - - - - - - - - - - - - 13UILDING DEPT REPRESENTATIVE: APPLICANT:�,t� BUILDING PERMIT,. CITY OF COLLEGE STATION 11 CIl . TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00001563 Application pin number . . . 584886 Page 2 Date 5/29/07 Special Notes and Comments Area. ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 30") WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO -------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT, CITY OF COLLEGE STATION 110,1 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 07-00001563 Date 5/29/07 Application pin number . . . 584886 ---------------------------------------------------------------------------- Special Notes and Comments BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER'PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 :-t ------------------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT, CITY OF COLLEGE STATION 110,1 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 07-00001563 Date 5/29/07 Application pin number . . . 584886 ---------------------------------------------------------------------------- Special Notes and Comments DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK -------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ------------------------------------------------------------- Fee summary Charged Paid Credited Due ---------- ---------- ---------- ---------- ---------- Permit Fee Total 637.00 637.00 .00 Plan Check Total .00 .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 Grand Total 1387.00 1387.00 .00 .00 .00 ------------------------------------------ L --- ----------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 11Q1 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 07-00001564 748408 2081 RAVENSTONE LOOP 184200-1102-0060 R109198 TEMP POLE CASTLEGATE SEC 1 PH 1 RESIDENTIAL PLANNED DEVL HOUSING 0 Date 5/29/07 Owner Contractor ------------------------ ------------------------ GREENS PRAIRIE INVESTORS LTD OWNER 4490 CASTLEGATE DR COLLEGE STATION TX 778453388 --------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . MA Permit pin number . 505016 Permit Fee . . . . 20.00 Issue Date . . . ----------------------------------------------------------------------- . 5/29/07 Valuation . . . . 0 Other Fees . . . ----------------------------------------------------------------------- . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary ----------------- Charged Paid Credited Due Permit Fee Total ---------- 20.00 ---------- 20.00 -------------------- .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ---- 1 ------------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: `� ALI For OKwe Use Only APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX CITY OF COLLEGE STATION WWW.CSTX.GOV Planning 6 Development Simko DATE. l � 24 _�o ITTRCC REG APPLICATION # 'M TEMP POLE # 01 ADDRESS/LOCATION: )eZ61,Fl Xqd.-%,71k4U oleljl LOT _,4�,ZBLOCK ..Ly/SUBDIVISION ell fT�L' _& SEC/PH BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: Cz/�y-► PHONE: t& e:::Elf f^ CONTRACTOR ADDRESS: 4�0Z ELECTRICIAN: HVAC: PLUMBER: _ GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) EW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: lVel-,✓ j►,o7-� PROPOSED USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR SIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJ YREGISTRATION# EABPRJ VALUATION: $ 1`7� `�„�,TOTAL AREA: efW HEATED AREA: (Cost of La r and Matenals) _j U?'_P`UBLIC SEWER ❑ SEPTIC/TREATMENT SYSTEM SEWER TAP: yjr SIZE 'WATER TAP: 3 u 11 SIZE ❑ OTHER TAP: NUMBER OF BEDROOMS NUMBER OF BATHROOMS INTERIOR WALL TYPE EXTERIOR WALL TYPE FOUNDATION TYPE: SIZE /l TEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE F7 DOUBLE TRIPLE ATTACHED F] DETACHED F-1 CARPORT SIGNATURE OF APPLICANT: *If proposed work involves new c mmercial construction or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only .5 -3. 3- o P-2 J�M Plans Examiner dock 01 Zoning Official Comments: ES r NO Fire Marshall Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating w I PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# D?_ / S 3 DATE: 67-a 3 V BUILDING ADDRESS: ao8 I. Foundation Requirements- Minimum City Foundation Standards N K A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated O II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck QK E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, rade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations A PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements OK K A. Stairway Details OK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening ? 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NAJ0 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi NA/ B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NA/ A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed OK "APPROVED PLANS PER IRC SECTION R106.3.1." S EXAMINER DATE LOT 5 BLOCK 2 ,- OPEN Y EASEM ENr co co o . o 0 0 ) N I-- W N o 0 Z W � J o U o R- 680. 00' D-06°06'43" L— 72.54' LC— 72.51 ' CB—S Ru° o v 0 o� Lom ;50) a LOJ55 BLOCK 2 -��d�,S' O o - o/1t�d (CALLED N 88'28'29I __j " W 85.07') N 88023'244' W 85.16