HomeMy WebLinkAboutADDN2007-01560 1425 HARPER'S FERRY RD BUILDING PERMITGY
oa (�(g/og ---Ac,
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS. AV'E
CO jLEGE STATION,, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number
Application pin ruinber
Property Address . . . . . .
Property ID:
R #
Application type description
Sohdivieion Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation _
Owner
------------------------
KRACHT, CHARLES & 14EATHER
1425 HARPERS .TERRY
COLLEGE STATION TX 77945
--- Structure Information 000 000
Construction Type
Occupancy Type . . . . . .
Other struct info .
07-00001560 Date 5/24J07
796240
1425 HARPER' S FERRY RE
578500-0001-0040
R93987
RESIDENTIAL, ADCITICN
SNUG T4ARBOR PHS 1
RURAL RESIDENTIAL SUB.
50000
Contractor
------------------------
CROWLEY CONSTRUCTION
2033 RAVENSTONE LOOP
COLLEGE STATION TX 77845
(979) 177-0285
ADDITION
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
EXTERICR WALL TYPE PLANK
IMPACT/PRORATA FEES PAID N/A
FOUNDATION TYPE SLAB
TYPE OF GARAGE (ATT/DET) N/A
HEATED AREA 834.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BAT14RCOMS 1.00
NUMBER OF BEDROOMS 1.00
SEWER TYPE PUBLIC
TAZ 444.00
-----Permit . . . . . . BUILDING PERMIT
Additional desc . . MA
Permit pin number 504274
Permit Fee 260.00 Plan Check Fee .00
Issue Date . . . . 5/23/07 Valuation 50000
Expiration Date . . 11/19/07
Qty Unit Charge Per Extension
BASE FEE 15.00
49.00 5.0000 THOU 2LDG, VAL 1001-50000 245.00
----------------------------------------------------------------------------
Special Notes and Comments
Narrow Wall. Bracing Fully Sheathed entire exterior.
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED B AN ARC- AULT CIRCUIT
----------------------------------- ----- -----�------------
BUILDING DEPTEpyRESENTATIVE:
APPLICANT:
ti'd SZS£0696L6 N011omiSN00 A3B MO210
3UILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONR� (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 07-00001560 Date 5/24/07
Application pin number . . . 796240
----------------------------------------------------------------------------
Special Notes and Comments
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
SORACA.RE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL P:,ATES. PRooF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE of OCCUPANCY WILL BE
ISSUED.
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lota Shall Have a Grade Fall Minimum of 6"
inches Within the First 1D' feet Away From the Foundation.
Walls.
ELECTRXCAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
M,LECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
➢iIT4 THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
RAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
Assure Proper GF1 Locations, Including One Within 25, Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL TEE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MOST INnICATE METHODS ON 'FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If bEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe o U.V-------------------------------------------
.
BUILDING DEPT REPREScNTATIVE:
APPLICANT:
£'d 9Z9£0696L6 NOIionbiSNOO X3B MO210
r
TEMPORARY DOLE PERMIT
CITY OF COLLEGE STATION
1101. TEXAS AVE
COLLEGE STATION, TY 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00001571 Date 5/24/07
Application pin number . . . 003091
Property Address . . . . . . 1425 HAR.PER'S FERRY P-D
Property ID: 578500-0001-0040
R #: R939$7
Application type description. TEMP POLE
Subdivision Name . . . . . . SNUG HARBOR PHS 1
Property Use _ . . . . . . .
Property Zoning . . . . . . . RURAL RESIDENTIAL SUB.
Application valuation - 0
Owner
Contractor
-
KRACKT, CHARLES &HEATHER
CROWL,EY CONSTRUCTION
1425 HARPERS FERRY
2033 RAVENSTONE LOOP
COLLEGE STATION
TX 17845
COLLEGE STATION
TX 77845
(979) 777-0285
-
J_-_---.J.-• . .
Permit
-
• TEMP POLE
PERMIT'
Additional desc .
. MA
Permit pin number
504266
Permit 'Fee
20.00
Issue Date . . .
. 5/23/07
Valuation--.---v-_----
- - -0-
Other-Feesy---___------___-____TEMP-ELECT-POLE-CONNECT-----_-45_00
__-.
-----
Fee summary
Charged
Credited
-----
Due
Permit Fee Total
.
---------
20.00
---Paid'
20.00 .00
00
Other Fee Total
45.00
45.00 .00
•00
Grand Total
65.00
65.00 .00
.00
-------------------------------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
6-d 9Z9C0696L6
N011omiSNOO A3WO0 JO
BUILDING PERMIT
CITY OF COLLEGE STATION
11011 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE_ (979)764-3570 FAX. (979)764-3496
Page 3
Application Number 07-0000166D Date 5/24/07
Application pin number
--- ---------796240-_----✓----------y------------V--
Special NOtee and Commente
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORIC IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
RECESSED LIG�ITING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE lC RATED AND SEALED TO PREVENT AIR LEAKAGE
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DLCTS, CEILING PANS AND RETURN AIR
SHOWERS AiM TUB/SHOWER COMBINATIONS SHALL BE EQCIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED In EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN' MATERIAL.
SIZNDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
ALL PLUMBING, ELECTRICAL, AINM HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Fee summary Charged Paid Credited Due
-
Permit Fee Total 260.00 260.00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 260.00 260.00 .00 .00
--------------------------------------- _1—';P44ZA� -----------
BUILDING DE
APPLICANT:
Z-d 9ZSE0696L6 N011mdiSN00 A3�MO210
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS'AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00001560 Date 5/24/07
Application pin number . . . 796240
Property Address . . . . . . 1425 HARPER'S FERRY RD
Property ID: 578500-0001-0040
R #: R93987
Application type description RESIDENTIAL, ADDITION
Subdivision Name . . . . . . SNUG HARBOR PHS 1
Property Use . . . . . . . .
Property Zoning . . . . . . . RURAL RESIDENTIAL SUB.
Application valuation . . . . 50000
Owner
Contractor
------------------------ ------------------------
KRACHT, CHARLES & HEATHER CROWLEY CONSTRUCTION
1425 HARPERS FERRY
2033 RAVENSTONE
LOOP
COLLEGE STATION
TX 77845 COLLEGE STATION
TX 77845
(979) 777-0285
--- Structure Information 000 000 ADDITION
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
PLANK
IMPACT/PRORATA FEES PAID
N/A
FOUNDATION TYPE
SLAB
TYPE OF GARAGE (ATT/DET)
N/A
HEATED AREA
834.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
1.00
NUMBER OF BEDROOMS
1.00
SEWER TYPE
PUBLIC
TAZ
444.00
----------------------------------------------------------------------------
Permit
BUILDING PERMIT
Additional desc
MA
Permit pin number
504274
Permit Fee . . . .
260.00 Plan Check Fee
.00
Issue Date . . . .
5/23/07 Valuation . .
. . 50000
Expiration Date . .
11/19/07
Qty Unit Charge
Per
Extension
BASE FEE
15.00
49.00 5.0000
THOU BLDG, VAL 1001-50000
245.00
----------------------------------------------------------------------------
Special Notes and Comments
Narrow Wall Bracing
Fully Sheathed entire exterior.
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
----------------------------------------------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS'AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 07-00001560 Date 5/24/07
Application pin number . . . 796240
----------------------------------------------------------------------------
Special Notes and Comments
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGL STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
3
Application Number . . . . . 07-00001560 Date
5/24/07
Application pin number . . . 796240
----------------------------------------------------------------------------
Special Notes and Comments
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
------------------------------
---------------------------
Permit Fee Total 260.00 260.00 .00
.00
Plan Check Total .00 .00 .00
.00
Grand Total 260.00 260.00 .00
.00
----------------------------------------------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE'STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00001571 Date 5/24/07
Application pin number . . . 003091
Property Address . . . . . . 1425 HARPER'S FERRY RD
Property ID: 578500-0001-0040
R #: R93987
Application type description TEMP POLE
Subdivision Name . . . . . . SNUG HARBOR PHS 1
Property Use . . . . . . . .
Property Zoning . . . . . . . RURAL RESIDENTIAL SUB.
Application valuation . . . . 0
Owner
Contractor
- -----------------------
KRACHT, CHARLES &
HEATHER
------------------------
CROWLEY CONSTRUCTION
1425 HARPERS FERRY
2033 RAVENSTONE LOOP
COLLEGE STATION
TX 77845
COLLEGE STATION
TX 77845
(979) 777-0285
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. MA
Permit pin number
. 504266
Permit Fee . . .
. 20.00
Issue Date . . .
. 5/23/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
----------------------------------------------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
w
w
w
N
PROPOSED
ADDITION
•'� `�� ��
BUILDl! G--S-INE ----------------------- ------------------
- �\
ASEp=jERT----------
-
HARPER'S FERRY ROAD
01 SITE FLAN
REFER CEO aoNI! xw� r.ea-o' nortru
LOT: 4-R
I BLOCK: 01
SUBDIVISION:
SNUG HARBOR
PHASE I
COLLEGE STATION, TX
BRAZOS COUNTY
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION WWW.CSTX.GOV
Planning d' Develnpmmc Services
For Office Use Only
DATE:`-((�� WMUC REG
APPLICATION # 91— 6420
�
TEMP POLE # C4 - I ) I I
ADDRESS/LOCATION:NX
LOT q BLOCK SUBDIVISION
BUSINESS/OWNER NAME: PHONE:
CONTRACTOR/HOMEOWNER:
PHONE:
CONTRACTOR ADDRESS: �,sT� I �v"� Creek
ELECTRICIAN: �lJ PLUMBER: v�
HVAC:GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION" SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK: 1 �Q c2 11�
PROPOSED USE:
HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ Cd Cz::� 5091fidk TOTAL AREA: HEATED AREA
(Cost of Labor and Materials)
❑ PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
SEWER TAP:
SIZE
❑ WATER TAP: k
SIZE
❑ OTHER TAP:
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE
EXTERIOR WALL TYPE:
FOUNDATION TYPE
Sl�h
aEi4
SIZE
`®-TEMP POLE ROOF TYPE: C/or1
/ GARAGE TYPE: SINGLE F—] DOUBLE F__] TRIPLE
ATTACHED DETAC D CARPORT
SIGNATURE OF APPLICANT:
'If proposed work involves new commercial co Ion or facade imps ents/renovations t an exi.
commercial property, building elevations ara4equired.
Official Use Only
S-Z7-o7
Plans Examiner
KAY
Zoning Official
Comments:
S or 0
Fire Marshall
Energy Code Compliance Information
% Glazing of exterior walls Alk
Insulation R value of exterior walls ( 3
Insulation R value of ceiling 1 (flat areas) 30
Insulation R value of ceiling 2 (vaulted areas/no attic) 1
Glazing SHGC O
Glazing U-Factor 75
R value of ductwork to
A/C SEER Rating 1
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# D S & O
DATE:_ ` o
BUILDING ADDRESS: rq s
I. Foundation Requirements- Minimum City Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
O
Il. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
ACN
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, s acing, roof slo e & urlin bracin if re uired to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
OK
QqYOK
A. Stairway Details
OK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
OK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
A 4rn fm ilt nrntection for bedroom circuits
5. Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
NA/ K
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N K
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vlll. Energy Requirements
NA/
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NAIAW
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N K
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NA/
Does not block any water course or divert any flow
Elevation certificate needed
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
EXAMINER
S' L� `0
DATE