Loading...
HomeMy WebLinkAboutRES2007-01553 926 TURTLE DOVE TRL BUILDING PERMITWF0910967 / 001 City of College Station PAGE 1 REQ. DATE: 05/30/07 05/30/07 16:39:28 LOCATION: 926 TURTLE DOVE TRL LOC ID: 204584 REQUESTOR: LEGEND BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE: SWR 4" WTR 3/411 ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 05/30/07 SCHED COMPLETION: 05/30/07 ******************************************************************************** JOB ORDER RESULT COMVM TrS PREPARED 8/22/07, 13:58:44 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/22/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 926 TURTLE DOVE TRL SUBDIV: CONTRACTOR LEGEND BUILDERS PHONE (979) 774-4600 OWNER . . PHONE PARCEL . . 230100-0209-0140 APPL NUMBER: 07-00001553 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 6/11/07 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 6/11/07 AP June 11, 2007 11:00:59 AM acarter. Strings On Setbacks O.K. Slab Ground Installed B115 01 7/31/07 RH BLDG, FRAMING TIME: 17:00 7/31/07 DP July 23, 2007 10:45:16 AM acarter. 07/31/2007 11:57 AM RH PDA Need anchors on backwall of garage as noted on prints. Need to bond gastite as noted on electrical rough -in. Installed insulation and brick prior to inspections. 9130 01 7/31/07 RH BLDG, INSULATION TIME: 17:00 1 7/31/07 DA July 26, 2007 3:47:26 PM acarter. Building accidently insulated. Dustin 324-3521 with Legend Builders says he will remove whatever or all insulation if needed. Call him if inspection can not be done and he will remove. July 30, 2007 10:34:43 AM tboriskie. 07/31/2007 11:58 AM RH PDA Need to complete framing issues. B115 02 8/01/07 RH BLDG, FRAMING TIME: 17:00 8/01/07 AP July 31, 2007 1:10:11 PM acarter. 08/01/2007 10:42 AM RH PDA Gastite gas line must be electricaly bonded by building final. B125 01 8/22/,07 BI BLDG, FINAL TIME: 17:00 i3 August 22, 2007 1:57:43 PM kwolfe. �J ------------------ -- --/--------- CONTINUED ONTO NEXT PAGE --o-,--------------------------------- ��'3 J(�� 55'-1 11 /16" BUILDINGI-PI'R fIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00001553 Date 5/30/07 Application pin number . . . 263559 Property Address . . . . . . 926 TURTLE DOVE TRL Property ID: 005401-0209-0140 R #: Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . DOVE CROSSING PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 155000 Owner Contractor ------------------------ ------------------------ LEGEND BUILDERS P.O. BOX 9356 COLLEGE STATION TX 77842 (979) 774-4600 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID N/A FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1765.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number . 505313 Permit Fee . . . . 625.00 Plan Check Fee .00 Issue Date . . . . 5/30/07 Valuation . . . . 155000 Expiration Date . . 11/26/07 Qty Unit Charge Per Extension BASE FEE 460.00 55.00 3.0000 THOU BLDG, VAL 100001-500000 165.00 ---------------------------------------------------------------------------- Special Notes and Comments Narrow Wall Bracing Fully Sheathed with Simpson Panels at Garage Returns and Interior Anchors and Bracing to Left of - --------------- ----- -------- BUILDING DEPT R.EPRESE ---------------- ---- -- -- TATIVE :� - ------------ Iiaw��, // BUILDING+PERMiT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 Application Number . . . . . 07-00001553 Application pin number . . . 263559 Special Notes and Comments Front Door. ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING Page 2 Date 5/30/07 UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 30") WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. ------------------------------------------- - --- z--------------- BUILDING DEPT„REPRESENTATIVE APPLICANT: BUILDING,PERMfT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 07-00001553 Date 5/30/07 Application pin number . . . 263559 ---------------------------------------------------------------------------- Special Notes and Comments REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT ITH CONRETE MUST BE ---------- - ---------------------------- ---------------- ---- BUILDING DEPT REPRESENTATIVE. �, i APPLICANT: BUILDING,PERMfT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 4 Application Number . . . . . 07-00001553 Date 5/30/07 Application pin number . . . 263559 ---------------------------------------------------------------------------- Special Notes and Comments TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ------------------------------ --------------------------- Permit Fee Total 625.00 625.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1375.00 1375.00 .00 .00 -----------------------------------------------�------------- BUILDING DEPT REPRESENTATIVE - - APPLICANT: a For Office Use Only I APPLICATION FOR BUILDING PERMIT DATE `TRC�REG 14111, CITY OF COLLEGE STATION Oq— (,W' 47/1 (SS 1101 TEXAS AVENUE APPLICATION # � COLLEGE STATION, TX 77840 TEMP POLE # CI rY ur• C+ sLI .G1. S NI ION (979) 764-3570 (979) 764-3496 FAX 1 LnnJ,g O' Un rkj>+nerrt �-n•x d WWW.CSTX.GOV ADDRESS/LOCATION: '� a1 I U?TLi'r DOME LOT /BLOCK SUBDIVISION DOVE CZOSSiW& SEC/PH_�_-�� BUSINESS/OWNER NAME: PHONE: v CONTRACTOR/HOMEOWNER: LEL.EWc-, SUTLO62s PHONE: 774-4boo CONTRACTOR ADDRESS: PO Boa 93546 . (ou.lF%L. STArTTIW` 4'C ?7AIA82 ELECTRICIAN: MATtf" F tc`=ie ic- PLUMBER: DEAuo ?u Me Lwc, HVAC: [ooLzwi, GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) IC NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: t`Is� R�'�I,DGw4F STRUCTURE USE: HOMEOWNER ASSOC IATION/ARC HITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL - TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ kc✓c, CIO � TOTAL AREA: 1_7�6� HEATED AREA: (Cost of Labor and Materials) 244 6 PUBLIC SEWER NUMBER OF BEDROOMS: -1 SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 3 © SEWER TAP WATER TAP ❑ OTHER TAP: TEMP POLE GARAGE TYPE: 4U SIZE 3 41 SIZE SIZE SINGLE ATTACHED INTERIOR WALL TYPE: EXTERIOR WALL TYPE FOUNDATION TYPE: ROOF TYPE: DOUBLE F�Wj TRIPLE DETACHED F—] CARPORT (iI?SAVrm 604R!) i 2SC,C VtA>-C-3W SLAB ©€►a C"Y2410 (_00%PC>5-x 'A) SIGNATURE OF APPLICANT- `z *If proposed work involves new commercial construct n cade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only pe .�' Z�Z � % YE rNO NO Plans Examiner / 0� /f-kaow -�v Zoning Official Energy Code Compliance Information % Glazing of exterior walls 8670 Insulation R value of exterior walls 3 Insulation R value of ceiling 1 (flat areas) 30 Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC 100 Glazing U-Factor R value of ductwork A/C SEER Rating . PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# O - !sS DATE: 5 - 2z -a7 BUILDING ADDRESS: �';zeo 7-UO4 bo bove 36d. I. Foundation Requirements- Minimum City Foundation Standards N A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated f4fiqOK II. Framing: Floor, Wall, Ceiling and Roof Requirements ffA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck ftXOK E. Header sizes indicated on plans N F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations Ui PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements OWOK OK A. Stairway Details OK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements K A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N K 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi NAMV B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units) T B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NA/ Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 NA/ Does not block any water course or divert any flow Elevation certificate needed K t�o "APPROVED PLANS PER IRC SECTION R106.3.1." LANS EXAMINER 5 �ZZ _D? DATE