Loading...
HomeMy WebLinkAboutRES2007-01552 919 CRYSTAL DOVE AVE BUILDING PERMITPREPARED 8/07/07, 7:25:57 INSPECTION TICKET PAGE 12 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/06/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 919 CRYSTAL DOVE AVE SUBDIV: CONTRACTOR LEGEND BUILDERS PHONE (979) 774-4600 OWNER . . PHONE PARCEL . . 230100-0104-0320 APPL NUMBER: 07-00001552 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 6/08/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00 6/08/07 AP June 8, 2007 8:46:34 AM kwolfe. Strings On Setbacks O.K. Slab Ground Installed B115 01 7/10/07 JGM BLDG, FRAMING TIME: 17:00 7/10/07 AE July 2, 2007 11:16:46 AM glsouth. 07/10/2007 11:22 AM JGM PDA need to seal all seams on register boxes B130 01 7/10/07 DS BLDG, INSULATION TIME: 17:00 7/10/07 AP July 10, 2007 10:36:55 AM acarter. B125 01 W-01 /07 ft BLDG, FINAL TIME: 17:00 � i0Z0 August 6, 2007 2 : 17: 34 PM acarter. ----------------------------------- CONTINUED ONTO NEXT PAGE----------------------------------- r 1 n � o �(r v � �� Q�� Date: 8/7/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 1552 Address: 919 CRYSTAL DOVE AVE Type Inspection Type Code Description Status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed B115 BLDG, FRAMING IC 07/10/2007 11:22 AM JGM PDA B115 BLDG, FRAMING IC need to seal all seams on register boxes E150 ELEC, FINAL IC Not Ready For Inspection E150 ELEC, FINAL IC 08/06/2007 11:35 AM RH PDA E150 ELEC, FINAL IC Need light in middle bedroom. Outside GFI not working. M100 MECH, ROUGH IN IC 07/05/2007 02:44 PM RH PDA M100 MECH, ROUGH IN IC Make sure the furnace flue has min. 1" of clearance from M100 MECH, ROUGH IN IC combustibles. M110 MECH, FINAL IC 07/31/2007 03:11 PM OC PDA M110 MECH, FINAL IC per amber Page 1 w WF0910970 / 001 City of College Station PAGE 1 REQ. DATE: 05/30/07 05/30/07 16:42:40 LOCATION: 919 CRYSTAL DOVE AVE LOC ID: 203250 REQUESTOR: LEGEND BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE: SWR 4" WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 05/30/07 SCHED COMPLETION: 05/30/07 ******************************************************************************** JOB ORDER RESULT COMMENTS City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . 8/08/07 Parcel Number . . . . . 230100-0104-0320 Property Address . . . 919 CRYSTAL DOVE AVE COLLEGE STATION TX 77845 Subdivision Name . . . Legal Description . . . DOVE CROSSING SUBDIVISION PHASE 1B BLK 4 LOT 32 Property Zoning . . . . SINGLE FAMILY RESIDENTIAL Owner Contractor . . . . . . LEGEND BUILDERS 979 774-4600 Application number 07-00001552 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . . . Approved Buil ' 04. /-4 a Official VOID UNLESS SIGNED BY BUILDING OFFICIAL (8/8/2007) Gina Southerland- Re: Calling for CO @ 919 Crystal Dove Ave Page 1 From: Paul Schoenfeld To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G... Date: 8/7/2007 3:45 PM Subject: Re: Calling for CO @ 919 Crystal Dove Ave All ok. Paul >>> Kim Wolfe 8/7/2007 8:01 AM >>> any issues? BP # 07-1552 Thanks Kimberly Wolfe, CPS/CAP City of College Station Planning & Development Services (979) 764-3570 www.cstx.4ov 55'-6 1 /4" •4- I I I I I I I I I I O I b I N I I I I I I I I I 7'-10 1 /4" I I I I I I I I I . I I I I I I I I I I I I I I I . I I I I I • I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I CV O N I I I I I I I I I I I I I I I I I I I r-----------------I I I I I I I I I I I I - -------------- I I I I I I I I I I • I I I I I I I I I I I I -------- I I I I • I I I I I I I I I I I I I I .I .I .I .I �I .I �I I I I O I I I I I I I I I I I I CRYSTAL DOVE AVENUE I I I 7'-6 i 7,- I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I ------------I-------- I JL- I I I I I V I I I I I I I n I V I I I I I I I I I I I I O Lo T T si SITE PLAN SCALE 1 /8" - 1' - 0" BUILDING PERMIT '--'";'"CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 ' FAX`: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00001552 Date 5/30/07 Application pin number . . . 930208 Property Address . . . . . . 919 CRYSTAL DOVE AVE Property ID: 005401-0104-0320 R #: R13907 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . DOVE CROSSING Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 155000 Owner Contractor ------------------------ ------------------------ LEGEND BUILDERS P.O. BOX 9356 COLLEGE STATION TX 77842 (979) 774-4600 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID N/A FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1765.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number . 505289 Permit Fee . . . . 625.00 Plan Check Fee .00 Issue Date . . . . 5/30/07 Valuation . . . . 155000 Expiration Date . . 11/26/07 Qty Unit Charge Per Extension BASE FEE 460.00 55.00 3.0000 THOU BLDG, VAL 100001-500000 165.00 ---------------------------------------------------------------------------- Special Notes and Comments Narrow Wall Bracing Fully Sheathed with Interior Anchors and Bracing to the left of Front Door Area -------------------------------------------------- BUILDING DEPT REPRE - -- - -�----------- E}�TATIVE: �- APPLICANT: BUILDING PERMIT ' CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 1 FAX: (979)764-3496 Application Number . . . . . 07-00001552 Application pin number . . . 930208 Page 2 Date 5/30/07 Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR ATTACHED GARAGES SHALL HAVE PENETRATIONS SEALED Assure Proper GFI Locations, Outside A/C Unit GARAGE DOOR HEADER ALL TOP PLATE AND HEADER Including One Within 25' Of PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE M THE NSI BUILDING DEPT -REPRESENTATIVE:/ APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 1 FAX: (979) 764-3496 Page 3 Application Number . . . . . 07-00001552 Date 5/30/07 Application pin number . . . 930208 ---------------------------------------------------------------------------- Special Notes and Comments WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WI H CONRETE MUST BE -----------------------------------------------------�J•----------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 Page 4 Application Number . . . . . 07-00001552 Date 5/30/07 Application pin number . . . 930208 ---------------------------------------------------------------------------- Special Notes and Comments TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ---------------------------------------- ----------------- Permit Fee Total 625.00 625.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1375.00 1375.00 .00 .00 ---------------------------------------- - '�----i-----YY---1,&---- ---- - - - - -- BUILDING DEPT REPRESF,,TATIVE: APPLICANT: �1 APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 Crry oi,' Cot.i.i,c,e S-rm ioN (979) 764-3570 (979) 764-3496 FAX 1'Ana:+iS eb (7rrvloprrerxrr ,YrrSero WWW.CSTX.GOV For Olfih Use Only DATE. .� If TRCC REG APPLICATION # TEMP POLE # ADDRESS/LOCATION: `� LOT " BLOCK V1 SUBDIVISION D QqC CQ C"_ SWCa J SEC/PH BUSINESS/OWNER NAME: �- PHONE: r--- CONTRACTOR/HOMEOWNER: LE'4Cw0 1&UXLOF2 " PHONE: 7 7 4 - 4 L 0v% CONTRACTOR ADDRESS: PO r_kpx `t r3 S (e C'OLL6 4.6 STui.,-Zow . Te 77W2 ELECTRICIAN: M4TH£;.j5 ItEt_•n ix PLUMBER: velow pf."%Mnwk HVAC: i✓lpS►4CP-tee. 6oa.i1,c GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) +l NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION" SWIMMING POOL Required) DESCRIPTION OF WORK: lbw ?,011 ktyCC STRUCTURE USE: t` eNlora'c HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ �5 OaU TOTAL AREA:.= HEATED AREA: (Cost of Lab r and Material FiCt PUBLIC SEWER NUMBER OF BEDROOMS: l i ❑ SEPTIC/TREATMENT SYSTEM gy�pp © SEWER TAP: !! " l FXJ WATER TAP: OTHER TAP: TEMP POLE GARAGE TYPE: SIZE SIZE SINGLE ATTACHED NUMBER OF BATHROOMS: 3 INTERIOR WALL TYPE: G`�PSNrn IiJf� EXTERIOR WALL TYPE: 9a13U. FASCIA FOUNDATION TYPE: SI44 On) 6P A'0 ROOF TYPE: Cpyngo'sy`T'zn') DOUBLE TRIPLE WACHED CARPORT SIGNATURE OF APPLICANT: 'If proposed work involves new commercial constru n o ade improvements/renovations to an existing commercial property, building elevations are requir6d. Official Use Only C ents: Plans Examiner Zoning Official ej Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) 30 Insulation R value of ceiling 2 (vaulted areas/no attic) 1 5 Glazing SHGC • 2 i Glazing U-Factor R value of ductwork A/C SEER Rating Cl 5 F I-t dwr'g�D � ,2 LF- y S Y PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# U _S DATE: BUILDING ADDRESS: I. Foundation Requirements- Minimum City Foundatioh Standards NAM A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated OK II. Framing: Floor, Wall, Ceiling and Roof Requirements A/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck A10K E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, rade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations I PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements OK V&D K A. Stairway Details K 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements K A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening ? 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: Ar 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location Sf PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) Vill. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NhM Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed K "APPROVED PLANS PER IRC SECTION R106.3.1." PLAN EXAMINER DATE