HomeMy WebLinkAboutRES2007-01536 912 TURTLE DOVE TRL BUILDING PERMITPREPARED 8/08/07, 12:00:49 INSPECTION TICKET PAGE 18
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/08/07
------------------------------------------------------------------------------------------------
ADDRESS . : 912 TURTLE DOVE TRL SUBDIV:
CONTRACTOR BRANDON BERRY CONSTRUCTION PHONE (979) 690-8670
OWNER . . PHONE
PARCEL . . 230100-0209-0070
APPL NUMBER: 07-00001536 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 5/24/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00
5/23/07 AP May 23, 2007 4:53:19 PM malford.
STRINGS ON SETBACK OK AND SLAB GROUND INSTALLED
May 23, 2007 4:53:52 PM malford.
STRINGS ON SETBACKS OK ,,,, SLAB GROUND INSTALLED
B115 01 6/28/07 RH BLDG, FRAMING TIME: 17:00
6/28/07 AE June 27, 2007 11:34:35 AM glsouth.
06/28/2007 03:32 PM RH PDA
Need secondary drain line by insulation.
B130 01 6/29/07 OC BLDG, INSULATION TIME: 17:00
7/02/07 AP June 29, 2007 9:38:29 AM acarter.
July 2, 2007 9:02:52 AM glsouth.
B12E-01 8/ 8/97 BLDG, FINAL TIME: 17:00
0�9a'7 �C_ August 8, 2007 10:39:00 AM glsouth.
-------------------------------------- COMMENTS AND NOTES --------------------------------------
Date: 8/8/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1536
Address: 912 TURTLE DOVE TRL
Insp.
Inspection Type Code
Description
status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
May 23, 2007 4:53:52 PM malford.
B100
BLDG, FOUNDATION -SLAB
IC
STRINGS ON SETBACKS OK ,,,, SLAB GROUND
INSTALLED
B115
BLDG, FRAMING
IC
06/28/2007 03:32 PM RH PDA
B115
BLDG, FRAMING
IC
Need secondary drain line by insulation.
M100
MECH, ROUGH IN
IC
06/28/2007 03:33 PM RH PDA
M100
MECH, ROUGH IN
IC
Need secondary drain line by insulation.
P125
PLBG, FINAL
IC
August 6, 2007 4:26:13 PM kwolfe.
Page 1
WF0910892 / 001 City of College Station
PAGE 1
REQ. DATE: 05/30/07 05/30/07 15:49:00
LOCATION: 912 TURTLE DOVE TRL LOC ID: 204570
REQUESTOR: BRANDON BERRY CONSTRUCTION ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
4" SWR TAP 3/4" WTR TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 05/30/07 SCHED COMPLETION: 05/30/07
********************************************************************************
JOB ORDER RESULT COMMENTS
(8/10/2007) Gina Southerland - Re: Calling for CO @ 912 Turtle Dove Trl Page 11
From: Terry Boriskie
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 8/9/2007 2:12 PM
Subject: Re: Calling for CO @ 912 Turtle Dove Trl
Notified Brandon Berry at 255-4196.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Paul Schoenfeld 8/8/2007 4:07 pm >>>
Water ok.
Sewer needs to be raised.
Paul
>>> Kim Wolfe 8/8/2007 12:10 PM >>>
any issues?
BP # 07-1536
Thanks
Kimberly Wolfe, CPS/CAP
City of College Station
Planning & Development Services
(979)764-3570
www.cstx.00v
10
INTERIOR BEAM BARsaisO.C. EXTERIOR BEAM
brick NNNpppea���\\\
1!2' r--
4 #E or 4 #6
605 or
BARS a #s
BARS
Vapor Retarder a'
(m nA poy) N i jpoly)
Jr mil3'
STIRRUPS
4' 14' #3 BARS ® 48" O4 go. W WM ® 24' 14'
6 ga. WWM Q 1E'
INTERIOR SLAB DROP
.......... ... ....... .......... .... .. .... .. .. ....
6'min.
GENERAL NOTES:
1. Exterior beam shall extend a minimum of 6 inches into undisturbed soil or fill which is
compacted to 95 % Standard Proctor (ASTM D 698) within ( J 2 % of optimum
moisture content. All fill material shall have a Plasiticity, Index (P.I.) between
5 and 18.
2. Interior beams that exceed 60 f . In length must be a minimum of 30" deep.
3. Maximum beam spacing shall be 15 feet and shall be continuous over the length or
width of the foundation.
4. Steel to be set to clear bare earth minimum 3". wood or steel form 1 -112".
5. Minimum concrete specified compression strength shall be 3000 psi @ 28 days.
6. Masonry fireplace footings shall be a minimum of 30".deep with 2 mats of #5's @
12" O.C. both ways.
7. These minimum standards shall apply to all foundations.
Exceptions:
A. Foundations for temporary buildings and permanent buildings not exceeding
one story In height and 400' square feel in area.
B. Foundations designed by an Architect registered in the State of Texas or a
civil/structural Engineer registered in the State of Texas and approved for use
by the Building Official.
8. All foundations designed by an Architect or Engineer shall be installed
as designed. Revisions and exceptions must be submitted in writing by
the Architect or Engineer and approved by the Building Official.
9. Reinforcing steel shall be grade 60 (grade 40 allowed for stirrups only).
All deformations shall meet ASTM A615.
INC/E$
Of !END$
BUILDING DMSION
- CITY OF COLLEGE STATION
MINIMUM
FOUNDATION
STANDARDS
!ILEA EPARE[1 72104 !MEET 1 OF 1
Rev. 03/05
Page 46 of 69
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE `j - l
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00001536 Date 5/21/07
Application pin number . . . 275968
Property Address . . . . . . 912 TURTLE DOVE TRL
Property ID: 005401-0209-0070
R #.
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . DOVE CROSSING PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 107712
Owner
Contractor
------------------------
------------------------
BRANDON BERRY CONSTRUCTION
3330 TRIPLE BEND
CIR
COLLEGE STATION
TX 77845
(979) 690-8670
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
N/A
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1632.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
MA
Permit pin number .
503318
Permit Fee . . . .
484.00 Plan Check Fee
.00
Issue Date . . . .
5/21/07 Valuation . .
. . 107712
Expiration Date . .
11/17/07
Qty Unit Charge Per Extension
BASE FEE 460.00
8.00 3.0000 THOU BLDG, VAL 100001-500000 24.00
----------------------------------------------------------------------------
Special Notes and Comments
Simpson Panels to be Placed at both sides of Garage Entry.
Could be braced prescriptively but bui der calls for Fully
----- 1- -45�
BUILDING DEPT REPRES TATIVE:
APPL I CANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS A' VE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 07-00001536 Date 5/21/07
Application pin number . . . 275968
----------------------------------------------------------------------------
Special Notes and Comments
Sheathed Method.
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away,From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR S CIAL tWL GE %T
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATON
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00001536 Date 5/21/07
Application pin number . . . 275968
----------------------------------------------------------------------------
Special Notes and Comments
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
------------
-------------
------------
�•- -----
BUILDING DEPT REPRESENTA�E
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE '
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 4
Application Number . . . . . 07-00001536 Date 5/21/07
Application pin number . . . 275968
----------------------------------------------------------------------------
Special Notes and Comments
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP
4"
350.00
WATER TAP
3/4"
400.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid
----------
Credited
--------------------
Due
-----------------
Permit Fee Total
----------
484.00
484.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1234.00
1234.00
.00
.00
J44461 - /J.
- /—� --- ----------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION yyyyyy CSTX GOV
For ORkee Use Only
DATE J TRCC t/--REG
APPLICATION # IV- I S SIO
TEMP POLE #
Planning 6 Development Stnitrr j
ADDRESS/LOCATION: 91 Z -T�..-t 0 r /
LOT _��OCK Cj SUBDIVISION\�`~� �'_ �-'> j i.a c --SEC/PH
TC n
BUSINESS/OWNER NAME: PHONE:
CONTRACTOR/HOMEOWNER: 5 - -L PHONE:
CONTRACTOR ADDRESS:
ELECTRICIAN: V14-3 4-1�3 PLUMBER: `� e
HVAC:, J «-6ti�. sir ✓� e-ei GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION' SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK: 4 -e_
PROPOSED USE: --'5 r,ti! � /z � .z; �y f,_— -.1 Pn c_ X_
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TA ROJECT REGISTRATION# EABPRJ
VALUATION: $ ID11-1I TOTAL AREA-7/6 o HEATED AREA: 14 3
(Cost of Labor and Materials)
DI'PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
SEWER TAP:
SIZE
a WATER TAP: -
SIZE
❑ OTHER TAP:
SIZE
TEMP POLE
GARAGE TYPE: SINGLE
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS
INTERIOR WALL TYPE
EXTERIOR WALL TYPE
FOUNDATION TYPE
ROOF TYPE:
DOUBLE 1� TRIPLE
ATTACHED E� DETACHED = CARPORT
IN
60 �_S
SIGNATURE OF APPLICANT:-u-z-�---
*If proposed work involves new commercial construction or facad VXn provements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
�--� -� -7
Plans Examiner
s %Y f o,%/ O�,ri� s Ca
Zoning Official
C events:
or NO
Fire Marshall
Energy Code Compliance Information
% Glazing
of exterior walls
Insulation R value of exterior walls
3
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
! I
Glazing SHGC
�p
Glazing U-Factor
/
R value of ductwork
/
A/C SEER Rating
1
I
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# n _ ! S 3
DATE:
BUILDING ADDRESS: ` I
Q
I. Foundation Requirements- Minimum Cit Foundation Sta ards
N K
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
O
II. Framing: Floor, Wall, Ceiling and Roof Requirements
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
K
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
NA/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
UOK
ffMOK
A. Stairway Details
OK
1.
Maximum riser height 7-3/4 inches
2.
Minimum tread width 10 inches
3.
Stairway risers are uniform 3/8" Max. difference
4.
Stairway width not less than 36 inches
5.
Stairway headroom not less that six ft. eight 6-8
B. Winder details
1.
Treads a minimum of six 6 inches on narrow edge
2.
Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1.
Riser height less than nine and one-half 9-1/2 inches
2.
Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3.
Stairway width not less than thirty-six inches
4.
Headroom required not less than six ft six 6-6 inches
5.
All treads must be identical
D. Guards/handrail details
1.
Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2.
Handrails are required on stairways located two or more risers above floor/grade
3.
Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4.
Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5.
Guards must be a minimum of thirty-six 36 inches above finished floor
6.
Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
A7PK
A. Hearth extensions
1.
Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2.
Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry
fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA'r
1.
Electrical fixtures & switches indicated
2.
Smoke detector locations indicated as required
3.
GFI circuits indicated where required
4.
Arc fault protection for bedroom circuits
5.
Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
NAB
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NA/011
Does not block any water course or divert any flow
Elevation certificate needed
t1K
"APPROVED PLANS PER IRC SECTION R106.3.1."
-5- _-I�--D�
S EXAMINER DATE