Loading...
HomeMy WebLinkAboutRES2007-01530 3708 DOVE HOLLOW LN BUILDING PERMITWF0906241 / 001 City of College Station t , PAGE 1 REQ. DATE: 05/22/07 05/22/07 9:26:04 LOCATION: 3708 DOVE HOLLOW LN LOC ID: 205460 REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE: SWR 4" WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 05/22/07 SCHED COMPLETION: 05/22/07 ******************************************************************************** JOB ORDER RESULT COMMENTS City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . 12/31/07 Parcel Number . . . . . 230100-0102-0050 Property Address . . . 3708 DOVE HOLLOW LN COLLEGE STATION TX 77845 Subdivision Name . . . Legal Description . . . DOVE CROSSING PH 1C BLK 2 LOT 5 Property Zoning . . . . SINGLE FAMILY RESIDENTIAL Owner . . . . . . . . . Contractor . . . . . . ED FROEHLING BUILDERS 979 776-8266 Application number 07-00001530 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . . . A, Approved . . . . . . . — By lding Official VOID UNLESS SIGNED BY BUILDING OFFICIAL Amber Carter- Re: Calling for C.O. @ 3708 Dove Hollow Ln 1 From: Terry Boriskie To: Amber Carter; Benjamin McCarty; Chris Haver; Date: 12/27/2007 10:41:18 am Subject: Re: Calling for C.O. @ 3708 Dove Hollow Ln Notified Froehling Builders at 776-8266. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Paul Schoenfeld Water lid broken. Sewer ok. Paul 12/26/2007 2:03 pm >>> >>> Gina Southerland 12/26/2007 10:48 AM >>> BP# 07-1530 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.cstx.gov ACE PEST CONTROL T.P.C.L. # 7120 PT PO BOX 4474 BRYAN, TX 77805 (979) 823-7777 (979) 774-4736 CERTIF CATF The following property O� • 1 O 'W built RUEHLINO HONSS State of Texas County of BRAZOS the city of COLLEGE JL4TION Mailing Address SAME , _ Zip code 77845 was treated for subterranean termites on this day SEF WER 29, 2W7 ^and has met with approval. Cost of initial treatment, S365A0, is payable upon completion of work. The treatment is guaranteed for 12 months from the date of treatment. Thereafter, this contract is subject to annual renewal (OPTIONAL) upon payment of annual inspection and renewal fee. of 1�30plus tax, for a period of, 4 years. ( see attached letter ) If at any time during this contract a 'reinfestation of subtmaneax termites should occur, the above said property will be treated at no additional cost to the owner. ACE PEST CONTROL does not accept any liability for any subterranean termite damage repair. Failure to pay the annual renewal fee within thirty days after the inspection date shall be construed as a cancellation of this contract. Any alteration or addition to the foundation of the above described property without proper termite treatment by ACE PEST CONTROL Services sball nullify this contract. Licensed and regulated by Structural Pest Control Board P.O. BOX 1927 Austin, TX 78767-1927 (512) 305-9250 TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT PropaM Owner-, IFROEHLIIVO HOMES 3M DOVE HOLLOW 9501 Type of Treatment, Full Partial XX yaja•l roc HorizontallPerlm0or d"m—XX— . I I - I I I ► e I ..� f, slzl I r o r A I ARI FOR ANY OTHER PEWnGDE RECOMMM OR USED HAS SEEN ATTACHED Al PART OF THIS DOCUMENT. WARRANTY e4q~TTON (IF ANY) MICLUOINO AREA COVERED. TM PERIOD OF WAISIANTY, PMMWAI OPTIDNEANO COST. THE 00"TOM OF THE PEST CONTROL OPERATOR TO RE- TRrAT FOR TERMITE OU WffATK" OR REPAIR bAmAda CAUSED NY TEIMMTE iNnITATIONS WITM THE WARRANTY PETUOD. AND THE CONDMONS THAT COULD DEVELOP A$ A ROMT OF THE OWNERS ACTION OR 01ACTION THAT WOULD VON) THE WM MY HAS AL$O KEN ATTACHER Charges for pretreat NOTES: Annual re-newal: $306.40 $130.00 32129 PT Cn or Tmewmi.n #DOS 0-6 =M PT u BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00001530 Date 5/21/07 Application pin number . . . 542830 Property Address . . . . . . 3708 DOVE HOLLOW LN Property ID: 005401-0102-0050 R #: R Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . DOVE CROSSING Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 116490 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDERS 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 --- Structure Information 000 000 SINGLE FAMILY RESIDENCE Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID DUE FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1765.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number . 503573 Permit Fee . . . . 511.00 Plan Check Fee .00 Issue Date . . . . 5/21/07 Valuation . . . . 116490 Expiration Date . . 11/17/07 Qty Unit Charge Per Extension BASE FEE 460.00 17.00 3.0000 THOU BLDG, VAL 100001-500000 51.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT ------------------------------------------------ ----- -- ---.- --------- BUILDING DEPT PRESENTA IVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 07-00001530 Date 5/21/07 Application pin number . . . 542830 =--------------------------------------------------------------------------- Special Notes and Comments INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. BUILDING DEPT nA�1/ 1 1 REPRESENTATIVE: /PPRnE�S/E�NT TIVE : APPLICANT: Y/I/IAW111, BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 07-00001530 Date 5/21/07 Application pin number . . . 542830 ---------------------------------------------------------------------------- Special Notes and Comments REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE BUILDING DEPT REPRESENTATIVE: APPLICANT: �_MA M � ,1' 114 - _ BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- i Page 4 Application Number . . . . . 07-00001530 Date 5/21/07 Application pin number . . . 542830 ---------------------------------------------------------------------------- Special Notes and Comments TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. Narrow Wall Bracing Fully Sheathed with 16" Minimum Dining and Garage Framing. I ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 -'--------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 511.00 511.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1261.00 1261.00 .00 .00 - APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US ADDRESS/LOCATION: 5 Fa Offl" Use Only DATE: APPLICATION # TEMP POLE # LOT f) ✓ BLOCK SUBDIVISION �/ ,� 9hSS 4 art SEC/PH I C / v b BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: &C� EOLIIA)i,, 91l'i l bF--R U�t'HONE: `7-%6 -%Ve (1' CONTRACTOR ADDRESS: ski 0,11,wjLw Too e :�i I �'1C `z Zss� 5 ELECTRICIAN:�.f= C-(t(C =� C PLUMBER: HVAC: 6 GOOD CENTS (Residential only): ACCESSORY/STORAGE ri ADDITION DEMOLITION (Asbestos Survey) DUPLEX (Landscape Plans Re4) ,DESCRIPTION OF WORK: r � f `1 STRUCTURE USE:y4I ELF I CLASS OF WORK LOCATION MOVING NEW CONSTRUCTION REMODEL/RENOVATION HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE -ROOF (Total/Partial) ONLY TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ 1,1,(p, � j 0 TOTAL AREA: JAq HEATED AREA: 176oS (Cost of and Materials) Q PUBLIC SEWER SEPTIC/TREATMENT SYSTEM a SEWER TAP: SIZE WATER TAP: -�L GI SIZE tJ OTHER TAP: SIZE TEMP POLE GARAGE TYPE: SINGLE ATTACHED NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE EXTERIOR WALL TYPE: �40.ZC'_X FOUNDATION TYPE: �( &e lk ROOF TYPE: DOUBLE 0 TRIPLE DETACHED F__] CARPORT a SIGNATURE OF APPLICANT: ' Official Use Only C ments: ES or NO P Plans Examiner Zoning Official aye W /H %n y s w� { ►��' (N. Dto 1'" 4 Gfttje A�_ &I Uw Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) _3O Insulation R value of ceiling 2 (vaulted areas/no attic)/ Glazing SHGC - 0 Glazing U-Factor • &4 , R value of ductwork A/C SEER rating 13 kc ,< PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# _ i 5 3o DATE: 5_ 18_0 BUILDING ADDRESS: 17dv ok\ow L.0 . I. Foundation Requirements- Minimum City Foundation Standards N A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated K II. Framing: Floor, Wall, Ceiling and Roof Requirements MAIM A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex K 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans NA/ F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations F PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements OK K A. Stairway Details OK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements NA/ A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N O 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi NAAK B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements NAPP A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window LI-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NARW Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 NA/ Does not block any water course or divert any flow Elevation certificate needed K "APPROVED PLANS PER IRC SECTION R106.3.1." JL A 'A PLANS EXAMINER S - .19" 01 DATE d REScheck Compliance Certificate 2000 IECC RES check Software Version 3.5 Release I b Data filename: C:\Program Files\Check\3708DH.rck TITLE: 3708 Dove Hollow Lane CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 05/16/07 DATE OF PLANS: 05/16/07 PROJECT INFORMATION: Lot 5 Block 2 Dove Crossing Subdivision Phase 1 C COMPANY INFORMATION: Ed Froehling Builder, Inc. COMPLIANCE: Passes Maximum UA = 657 Your Home UA = 607 7.6% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.36 Ceiling l: Flat Ceiling or Scissor Truss Wall l: Wood Frame, 16" o.c. Window l: Metal Frame, Double Pane with Low-E SHGC: 0.40 Bldg. faces 45 deg. from North; Comp. orient.: Front Projection factor: 0.19 Door 1: Solid Wall 2: Wood Frame, 16" o.c. Window 2: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 45 deg. from North; Comp. orient.: Left Side Projection factor: 0.27 Door 2: Glass SHGC: 0.78 Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1765 30.0 0.0 62 396 13.0 0.0 25 50 0.640 32 38 402 46 18 13.0 0.0 0.400 15 28 0.640 29 0.580 10 Bldg. faces 45 deg. from North; Comp. orient.: Left Side Projection factor: 0.81 Wall 3: Wood Frame, 16" o.c. 396 13.0 0.0 21 Window 3: Metal Frame:Double Pane with Low-E 134 0.640 86 SHGC: 0.40 Bldg. faces 45 deg. from North; Comp. orient.: Back Projection factor: 0.23 Wall 4: Wood Frame, 16" o.c. 402 13.0 0.0 32 Window 4: Metal Frame:Double Pane with Low-E 9 0.640 6 SHGC: 0.40 Bldg. faces 45 deg. from North; Comp. orient.: Right Side Projection factor: 0.27 Floor 1: Unheated 250 0.0 261 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 10 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release lb (formerly MECchec/ and to comply with the mandatory requirements listed in the RES check Inspection Checklist. Builder/Designer Date Dove Crossing Subdivision Scale 1" = 20' N 48 04' 39" W 126.04' ELEC BOX I o 20' P U E CI)1' FROM CORNER °' N d ^� r, J N n � }' 0 N Ve W. Cq 'Proposed Residence � � r-Lir����1� W! i��•4 _ 3'yI ,i Y��.`.•r • Concrete S _ Dnveway '• N C N ONd. m Lot 6 Block 2 `� 00 M W J 1 ' J 21 4923' 48.6476' / e CO Itc s / 1 Lot 4 Block 2 \ N Dove Hollow Lane 50 R.O.W. - 27' Pavement