HomeMy WebLinkAboutRES2007-01524 2407 STONE CASTLE CIR BUILDING PERMITPREPARED 9/28/07, 12:40:55 INSPECTION TICKET PAGE 6
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 9/28/07
------------------------------------------------------------------------------------------------
ADDRESS . : 2407 STONE CASTLE CIR SUBDIV: CASTLEGATE PH 1 SEC 7
CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222
OWNER . . PHONE
PARCEL . . 184200-1730-0040
APPL NUMBER: 07-00001524 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B115 01 7/03/07 OC BLDG, FRAMING TIME: 17:00
7/05/07 DP July 3, 2007 11:30:39 AM kwolfe.
Sheetrock Fireplace Chase, Firestopping
07/05/2007 08:30 AM OC PDA
draft stop throughout . hangers throughout .cannot see
nailling pattern for wind braced walls per plan.also need
blocking on wind braced per plan. support needed under
roof rafter splices.
B115 02 7/09/07 OC BLDG, FRAMING TIME: 17:00
7/09/07 DP July 9, 2007 8:05:27 AM glsouth.
Sheetrock Fireplace Chase, Firestopping
07/09/2007 03:22 PM OC PDA
still need blocking on windbraced walls and still cannot
see nailling pattern as per plan.
B115 03 7/11/07 RH BLDG, FRAMING TIME: 17:00
` 7/11/07 AP July 11, 2007 9:02:02 AM acarter.
B130 01 7/13/07 JGM BLDG, INSULATION TIME: 17:00
7/13/07 AP July 13, 2007 9:58:28 AM kwolfe.
B145 01 7/18/07 JGM BLDG, EXT. SHEATHING FASTENER TIME: 17:00
7/18/07 AP July 18, 2007 10:18:07 AM kwolfe.
07/18/2007 03:28 PM JGM PDA
sheetrock fastener
B125 01 �9/�a7B,I „ _ BLDG, FINAL TIME: 17:00
- Val
P P September 28, 2007 11:06:51 AM acarter.
-------------------------------------- COMMENTS AND NOTES --------------------
------------------
�� � � �-� ► 9� ,IS f ,� }-� l r ec/
n�
0
Date: 9/28/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1524
Address: 2407 STONE CASTLE CIR
Insp.
Inspection Type Code
Description
p.
status
6115
BLDG, FRAMING
IC
6115
BLDG, FRAMING
IC
6115
BLDG, FRAMING
IC
6115
BLDG, FRAMING
IC
6115
BLDG, FRAMING
IC
13115
BLDG, FRAMING
IC
6115
BLDG, FRAMING
IC
6115
BLDG, FRAMING
IC
6115
BLDG, FRAMING
IC
13115
BLDG, FRAMING
IC
B145
BLDG, EXT. SHEATHING FASTENER
IC
B145
BLDG, EXT. SHEATHING FASTENER
IC
E150
ELEC, FINAL
IC
E150
ELEC, FINAL
IC
E150
ELEC, FINAL
IC
P125
PLBG, FINAL
IC
P125
PLBG, FINAL
IC
Page 1
Date: 9/28/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1524
Address: 2407 STONE CASTLE CIR
Inspection Result Comments
Sheetrock Fireplace Chase, Firestopping
07/05/2007 08:30 AM OC PDA
draft stop throughout . hangers throughout .cannot see
nailling pattern for wind braced walls per plan.also need
blocking on wind braced per plan. support needed under
roof rafter splices.
Sheetrock Fireplace Chase, Firestopping
07/09/2007 03:22 PM OC PDA
still need blocking on windbraced walls and still cannot
see nailling pattern as per plan.
07/18/2007 03:28 PM JGM PDA
sheetrock fastener
09/24/2007 03:40 PM RH PDA
HAVE DAMP LOCATION FIXTURES BY TUBS BEFORE
BLDG FINAL.
WHAT IS FLOOR PLUG IN KITCHEN FLOOR?
09/25/2007 04:12 PM JGM PDA
need minimum 5 psi
Page 1 b
AREA
FINISHING NOTES
SUMMARY
�
w �
1 Notes
Q
More Home, Less Money o o
cd
¢a
o
a ¢
>�E+
F�a
- --- - -
'� I
------ -- -------I
I
LOCATION
SUBDIV.
G-7
\11
PHASE
01
BLOCK
03
I I
�e
r a
xN,�w�u
I
ILOT
� o
QK
�
I
I�
NKae u,c,e
I
I Ulmf
W b4
`
O
Y
19=, I o
IaWI
lil L° J °
Ll
V M
U v
0
< a
m;
0
�I
W
wm'w
m
olb4
W
O
W O
I--
m--
COMMENTS
U M
Q F
0
O"
PLAN PREVIEW
a
ax
1 SCALE:3/32"=1'-O"
N
Q
NOTICE
a
t
THIS SET OF DRAWINGS FOR A HOME IS THE
COPYRIGHTED PROPERTY OF STYLECRAFT
BUILDERS, INC. THIS SINGLE COPY IS LICENSED AND
NO RIGHT TO REPRODUCE, COPY OR DUPLICATE ALL
OR ANY PORTION OF THE LICENSED PLANS IS
GRANTED, EITHER EXPRESSLY OR IMPLIED.
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THE DRAWING ARE
OWNED BY AND THE PROPERTY OF THE DESIGNERS
w
AND WERE CREATED, EVOLVED AND DEVELOPED
FOR USE ON AND IN CONNECTION WITH THE
`n
e
SPECIFIED PROJECT. NONE OF SUCH IDEAS,
DESIGNS, ARRANGEMENTS OR PLANS SHALL BE
z
Z
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR
CORPORATION FOR ANY PURPOSE WHATSOEVER
WITHOUT THE WRITTEN PERMISSION OF THE
DESIGNERS.
p
U
k
SHEET
AFRONT ELEVATION
G_
1
SCALE:3/32"=1'-0"
COVER SHEET
SHEET INDEX
COVER SHEET
G-1
GENERAL NOTES
G-2
SITE PLAN
C-1
FOUNDATION PLAN
S-1
DIMENSION PLAN
S-2
DETAILS
S-3
BRACING PLAN
S-4
FRAMING PLAN
S-5
ROOF FRAMING PLAN
S-6
DECKING LAYOUT
S-7
ELEVATIONS
S-8
FRAMING DETAILS
S-9
ELECTRICAL PLAN
E-1
FLOOR PLAN
A-1
FLOORING PLAN
A-2
CABINET LAYOUT
A-3
PLAN APPROVAL
APPROVED
INITIALS
DATE
ADMINISTRATOR
/
SUPERINTENDENT
/
CUSTOMER
/
-AREA
SUMMARY
I
10'
I
I
I ,
I
I
I
I I
I
I
I
1 I
I
I
I
I
I ,
Is
�y
S 56"25'52" E
—--—t%-2T—--
O
I
O
U
N
[�+
�
O
�
U
cn
w
N
I
N
I
U
I
l 2407 STONE CASTLE CIRCLE
j CASTLEGATE 7
ILOT -4
BLOCK - 3
PHASE - I
vq
1 SITE PLAN
SCALER "=20'-0"
SHEET:
C-1
SITE PLAN
(10/3/2007) Gina Southerland - Re: Calling for C.O. @ 2407 Stone Castle Cir.
Page 1
From: Paul Schoenfeld
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 9/28/2007 4:01 PM
Subject: Re: Calling for C.O. @ 2407 Stone Castle Cir.
ALL OK.
PAUL
>>> Gina Southerland 9/28/2007 1:19 PM >>>
BP# 07-1524
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.cstx.4ov
BUILDING PERMIT
CITY OF COLLEGE STATION
1101•-TEXAS AVE
COLLEGE ST TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00001524 Date 5/24/07
Application pin number . . . 273812
Property Address . . . . . . 2407 STONE CASTLE CIR
Property ID: 184200-1730-0040
R #.
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . CASTLEGATE PH 1 SEC 7
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 145114
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
MASONRY
IMPACT/PRORATA FEES PAID
PAID ON SLAB
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2964.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TAZ
441.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
GS
Permit pin number .
504290
Permit Fee . . . .
598.00 Plan Check Fee
.00
Issue Date . . . .
5/24/07 Valuation . .
. . 145114
Expiration Date . .
11/20/07
Qty Unit Charge
Per
Extension
BASE FEE
460.00
46.00 3.0000
THOU BLDG, VAL 100001-500000
138.00
----------------------------------------------------------------------------
Special Notes and Comments
Slab and Plumbing done
under permit #07-975 Slab Only.
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
--------------------------------------------- - --- �.1•-,l%9----------
BUILDING DEPT REP�TATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXA AVE
COLLEGE SI'ATIO&, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 07-00001524 Date 5/24/07
Application pin number . . . 273812
----------------------------------------------------------------------------
Special Notes and Comments
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH ME SURED AT THE l,=
--------------------------------------------- ---- - - G----------
BUILDING DEPT REPRESENTA-TT'�E:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00001524 Date 5/24/07
Application pin number . . . 273812
----------------------------------------------------------------------------
Special Notes and Comments
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOV DRAIN HALL BE
BUILDING DEPT REPRESENT,4r?1`SkE :
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE S'1ATIOk, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 4
Application Number . . . . . 07-00001524 Date 5/24/07
Application pin number . . . 273812
----------------------------------------------------------------------------
Special Notes and Comments
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 598.00 598.00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 598.00 598.00 .00 .00
BUILDING DE
APPLICANT:
_ - APPLICATION FOR BUILDING PERMIT
f*. CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX T7840
CriyOF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
P!' nin-d-D=1op.eSernica
WINW.CSTX.GOV
r�r 0Fs UM�c.,:�
DATE-1� `r/RCC REG
APPLICATION m l -
TEMP POLE
ADDRESS/LOCATION: —7�407 !G17Ne k i LC C I
C-
LOT 4 1/ BLOCK 3 V SUBDIVISION 6A5 i LE 67ATe d SEC/PH —7
BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR ADDRESS: _ 4090 State Highway 6 South
ELECTRICIAN: _ Brazos Valley Electric PLUMBER: Bass Plumbing
HVAC: Control Tema GOOD CENTS (Residential only): No
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) H
NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: Conventional Framing , LESS SL.. R
STRUCTURE USE: Single Family Residence
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ NIA
VALUATION: S /y 5 / 114 .20 1010TOTAL AREA: 2q 6y HEATED AREA: 24 4 -5
(Cost of Labor and Materials)
/q X PUBLIC SEWER NUMBER OF BEDROOMS:
7
f SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: �7
SEWER TAP:
JA WATER TAP: cx- §&'
SLZE
OTHER TAP:
Srz-�j^(
*EVP POLE P Ar- ! .
GARAGE TYPE: SINGLE
ATTACHED
INTERIOR WALL TYPE: Sheet Rock
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE �d TRIPLE
Siding and/or Masonry
Slab on Grade
Composition
0
0
SIGNATURE OF APPLICANT: L l O For Stylecraft
*If proposed work involves new commercial co structiLa.cade proveme is enovations to an existing
commercial property building elevations are required.
000000ee0000eaoe0000e.00ea00000000Officialy
YE rNO
l Plans Examiner I -I zVho Zoning Official
S lc� oK,ly dk 0'1 — �I iS �Ge.�u tic W/N E-"0'0t&W Kt&'C.ring
Jnergy Code Compliance In orma on
% Glazing of exterior walls 211
Insulation R value of exterior walls
R13
/
Insulation R value of ceiling 1 (flat areas)
R30
Insulation R value of ceiling 2 (vaulted areas/no attic)
R19
Glazing SHGC
.40
/
Glazing U-Factor
.65
R value of ductwork
R6
A/C SEER Rating
13 .-
✓�
,4
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 0 07 — / q 7
DATE:
BUILDING ADDRESS: o.2 q 0 ToNe 1e Cl e .
I. Foundation Requirements- Minimum City Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
COOK
Il. Framing:
Floor, Wall, Ceiling and Roof Requirements
NA109
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
NA/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, rade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
&OK
WOK
A. Stairway Details
JN~
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NfiTJ
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
NAIMV
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NAO
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
f
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NArX
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NAW
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
"PLANS EXAMINER
- /7-a'7
DATE
REScheck Software Version 4.0.1
Compliance Certificate
Project Title: 2350 Plan
Report Date: 05/16/07
Data filename: \\STYLECRAFTI\Share\ACAD\RESCheck\2350.2443-2407 Stone Castle.rck
Energy Code:
2006 IECC
Location:
College Station, Texas
Construction Type:
Single Family
Conditioned Floor Area:
2443 ft2
Glazing Area Percentage:
21%
Heating Degree Days:
1788
Climate Zone:
2
Construction Site:
Owner/Agent:
Designer/Contractor:
College Station, TX 77845
Stylecraft Builders, Inc.
Stylecraft Builders, Inc.
4090 SH 6 South
4090 SH 6 South
College Station, TX 77845
College Station, TX 77845
979-690-1222 x120
979-690-1222 x120
ewivagg@stylecraft-builders.com
ewivagg@stylecraft-builders.com
Maximum SHGC: Your SHGC: 0.40
0.40
Wall 1: Wood Frame, 16" o.c.:
2486
Window 1: Metal Frame:Double Pane with Low-E:
8
SHGC: 0.40
Window 2: Metal Frame:Double Pane with Low-E:
18
SHGC: 0.40
Window 3: Metal Frame:Double Pane with Low-E:
10
SHGC: 0.40
Window 4: Metal Frame:Double Pane with Low-E:
4
SHGC: 0 40
Window 5: Metal Frame:Double Pane with Low-E:
20
SHGC: 0.40
Window 6: Metal Frame:Double Pane with Low-E:
8
SHGC: 0.40
Window 7: Metal Frame:Double Pane with Low-E:
10
SHGC: 0.40
Window 8: Metal Frame:Double Pane with Low-E:
4
SHGC: 0.40
Window 9: Metal Frame: Double Pane with Low-E:
8
SHGC: 0.40
Window 10: Metal Frame: Double Pane with Low-E:
8
SHGC: 0.40
Window 11: Metal Frame:Double Pane with Low-E:
8
SHGC: 0.40
Window 12: Metal Frame:Double Pane with Low-E:
18
SHGC: 0.40
Window 13: Metal Frame:Double Pane with Low-E:
18
SHGC: 0.40
Window 14: Metal Frame:Double Pane with Low-E:
18
SHGC: 0.40
Window 15: Metal Frame:Double Pane with Low-E:
18
SHGC: 0.40
Window 16: Metal Frame:Double Pane with Low-E:
18
2350 Plan
13.0 0.0
159
0.670
5
0.670
12
0 670
7
0.670
3
0.670
13
0.670
5
0.670
7
0.670
3
0.670
5
0.670
5
0.670
5
0.670
12
0.670
12
0 670
12
0.670
12
0.670
12
Page 1 of 2
SHGC: 0.40
Window 17: Metal Frame:Double Pane with Low-E:
SHGC: 0.40
Window 18: Metal Frame:Double Pane with Low-E:
SHGC: 0.40
Window 19: Metal Frame -Double Pane with Low-E:
SHGC: 0.40
Window 20: Metal Frame:Double Pane with Low-E:
SHGC: 0.40
Window 21: Metal Frame:Double Pane with Low-E:
SHGC: 0.40
Window 22: Metal Frame: Double Pane with Low-E:
SHGC: 0.40
Window 23: Metal Frame:Double Pane with Low-E:
SHGC: 0.40
Window 24: Metal Frame:Double Pane with Low-E:
SHGC: 0.40
Window 25: Metal Frame:Double Pane with Low-E:
SHGC: 0.40
Window 26: Metal Frame:Double Pane with Low-E:
SHGC: 0.40
Window 27 Twin: Metal Frame:Double Pane with Low-E:
SHGC: 0.40
Window 27 Twin: Metal Frame:Double Pane with Low-E:
SHGC: 0.40
Window 28: Metal Frame:Double Pane with Low-E:
SHGC: 0.40
Window 29: Metal Frame:Double Pane with Low-E:
SHGC: 0.40
Window 30: Metal Frame: Double Pane with Low-E:
SHGC: 0.40
Door 1: Solid:
Door 2: Glass:
SHGC: 0.40
Ceiling 1: Flat Ceiling or Scissor Truss:
Floor 1: Slab -On -Grade: Unheated:
Insulation depth: 0.0'
Furnace 1: Forced Hot Air: 80 AFUE
Air Conditioner 1: Electric Central Air: 13 SEER
28
28
28
28
28
28
18
18
18
6
16
16
16
6
18
38
18
2443
223
30.0 0.0
0.0
0.670 19
0.670 19
0.670 19
0.670 19
0.670 19
0.670 19
0.670 12
0.670 12
0.670 12
0.670 4
0.670 11
0.670 11
0.670 11
0.670 4
0.670 12
0.500 19
0.440 8
86
232
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2006 IECC requirements in
REScheck Version 4.0.1 and to comply with the mandatory requirem d in the REScheck Inspection Checklist.
"iLAonzA Pj— r5v1&or.--Y2,S )Z-
Name - Title Signatu L
Dat
Project Notes:
All U-Factors and SHGC are at entered at higher than actual amounts.
Actual amounts are lower, but are entered higher to account for
differences in ratings per material.
2350 Plan Page 2 of 2