HomeMy WebLinkAboutRES2007-01524 2407 STONE CASTLE CIR BUILDING PERMITPREPARED 9/28/07, 12:40:55 INSPECTION TICKET PAGE 6 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 9/28/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 2407 STONE CASTLE CIR SUBDIV: CASTLEGATE PH 1 SEC 7 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER . . PHONE PARCEL . . 184200-1730-0040 APPL NUMBER: 07-00001524 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B115 01 7/03/07 OC BLDG, FRAMING TIME: 17:00 7/05/07 DP July 3, 2007 11:30:39 AM kwolfe. Sheetrock Fireplace Chase, Firestopping 07/05/2007 08:30 AM OC PDA draft stop throughout . hangers throughout .cannot see nailling pattern for wind braced walls per plan.also need blocking on wind braced per plan. support needed under roof rafter splices. B115 02 7/09/07 OC BLDG, FRAMING TIME: 17:00 7/09/07 DP July 9, 2007 8:05:27 AM glsouth. Sheetrock Fireplace Chase, Firestopping 07/09/2007 03:22 PM OC PDA still need blocking on windbraced walls and still cannot see nailling pattern as per plan. B115 03 7/11/07 RH BLDG, FRAMING TIME: 17:00 ` 7/11/07 AP July 11, 2007 9:02:02 AM acarter. B130 01 7/13/07 JGM BLDG, INSULATION TIME: 17:00 7/13/07 AP July 13, 2007 9:58:28 AM kwolfe. B145 01 7/18/07 JGM BLDG, EXT. SHEATHING FASTENER TIME: 17:00 7/18/07 AP July 18, 2007 10:18:07 AM kwolfe. 07/18/2007 03:28 PM JGM PDA sheetrock fastener B125 01 �9/�a7B,I „ _ BLDG, FINAL TIME: 17:00 - Val P P September 28, 2007 11:06:51 AM acarter. -------------------------------------- COMMENTS AND NOTES -------------------- ------------------ �� � � �-� ► 9� ,IS f ,� }-� l r ec/ n� 0 Date: 9/28/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 1524 Address: 2407 STONE CASTLE CIR Insp. Inspection Type Code Description p. status 6115 BLDG, FRAMING IC 6115 BLDG, FRAMING IC 6115 BLDG, FRAMING IC 6115 BLDG, FRAMING IC 6115 BLDG, FRAMING IC 13115 BLDG, FRAMING IC 6115 BLDG, FRAMING IC 6115 BLDG, FRAMING IC 6115 BLDG, FRAMING IC 13115 BLDG, FRAMING IC B145 BLDG, EXT. SHEATHING FASTENER IC B145 BLDG, EXT. SHEATHING FASTENER IC E150 ELEC, FINAL IC E150 ELEC, FINAL IC E150 ELEC, FINAL IC P125 PLBG, FINAL IC P125 PLBG, FINAL IC Page 1 Date: 9/28/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 1524 Address: 2407 STONE CASTLE CIR Inspection Result Comments Sheetrock Fireplace Chase, Firestopping 07/05/2007 08:30 AM OC PDA draft stop throughout . hangers throughout .cannot see nailling pattern for wind braced walls per plan.also need blocking on wind braced per plan. support needed under roof rafter splices. Sheetrock Fireplace Chase, Firestopping 07/09/2007 03:22 PM OC PDA still need blocking on windbraced walls and still cannot see nailling pattern as per plan. 07/18/2007 03:28 PM JGM PDA sheetrock fastener 09/24/2007 03:40 PM RH PDA HAVE DAMP LOCATION FIXTURES BY TUBS BEFORE BLDG FINAL. WHAT IS FLOOR PLUG IN KITCHEN FLOOR? 09/25/2007 04:12 PM JGM PDA need minimum 5 psi Page 1 b AREA FINISHING NOTES SUMMARY � w � 1 Notes Q More Home, Less Money o o cd ¢a o a ¢ >�E+ F�a - --- - - '� I ------ -- -------I I LOCATION SUBDIV. G-7 \11 PHASE 01 BLOCK 03 I I �e r a xN,�w�u I ILOT � o QK � I I� NKae u,c,e I I Ulmf W b4 ` O Y 19=, I o IaWI lil L° J ° Ll V M U v 0 < a m; 0 �I W wm'w m olb4 W O W O I-- m-- COMMENTS U M Q F 0 O" PLAN PREVIEW a ax 1 SCALE:3/32"=1'-O" N Q NOTICE a t THIS SET OF DRAWINGS FOR A HOME IS THE COPYRIGHTED PROPERTY OF STYLECRAFT BUILDERS, INC. THIS SINGLE COPY IS LICENSED AND NO RIGHT TO REPRODUCE, COPY OR DUPLICATE ALL OR ANY PORTION OF THE LICENSED PLANS IS GRANTED, EITHER EXPRESSLY OR IMPLIED. ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THE DRAWING ARE OWNED BY AND THE PROPERTY OF THE DESIGNERS w AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE `n e SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE z Z USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF THE DESIGNERS. p U k SHEET AFRONT ELEVATION G_ 1 SCALE:3/32"=1'-0" COVER SHEET SHEET INDEX COVER SHEET G-1 GENERAL NOTES G-2 SITE PLAN C-1 FOUNDATION PLAN S-1 DIMENSION PLAN S-2 DETAILS S-3 BRACING PLAN S-4 FRAMING PLAN S-5 ROOF FRAMING PLAN S-6 DECKING LAYOUT S-7 ELEVATIONS S-8 FRAMING DETAILS S-9 ELECTRICAL PLAN E-1 FLOOR PLAN A-1 FLOORING PLAN A-2 CABINET LAYOUT A-3 PLAN APPROVAL APPROVED INITIALS DATE ADMINISTRATOR / SUPERINTENDENT / CUSTOMER / -AREA SUMMARY I 10' I I I , I I I I I I I I 1 I I I I I I , Is �y S 56"25'52" E —--—t%-2T—-- O I O U N [�+ � O � U cn w N I N I U I l 2407 STONE CASTLE CIRCLE j CASTLEGATE 7 ILOT -4 BLOCK - 3 PHASE - I vq 1 SITE PLAN SCALER "=20'-0" SHEET: C-1 SITE PLAN (10/3/2007) Gina Southerland - Re: Calling for C.O. @ 2407 Stone Castle Cir. Page 1 From: Paul Schoenfeld To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G... Date: 9/28/2007 4:01 PM Subject: Re: Calling for C.O. @ 2407 Stone Castle Cir. ALL OK. PAUL >>> Gina Southerland 9/28/2007 1:19 PM >>> BP# 07-1524 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.cstx.4ov BUILDING PERMIT CITY OF COLLEGE STATION 1101•-TEXAS AVE COLLEGE ST TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00001524 Date 5/24/07 Application pin number . . . 273812 Property Address . . . . . . 2407 STONE CASTLE CIR Property ID: 184200-1730-0040 R #. Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE PH 1 SEC 7 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 145114 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE MASONRY IMPACT/PRORATA FEES PAID PAID ON SLAB FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2964.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 441.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number . 504290 Permit Fee . . . . 598.00 Plan Check Fee .00 Issue Date . . . . 5/24/07 Valuation . . . . 145114 Expiration Date . . 11/20/07 Qty Unit Charge Per Extension BASE FEE 460.00 46.00 3.0000 THOU BLDG, VAL 100001-500000 138.00 ---------------------------------------------------------------------------- Special Notes and Comments Slab and Plumbing done under permit #07-975 Slab Only. ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING --------------------------------------------- - --- �.1•-,l%9---------- BUILDING DEPT REP�TATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXA AVE COLLEGE SI'ATIO&, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 07-00001524 Date 5/24/07 Application pin number . . . 273812 ---------------------------------------------------------------------------- Special Notes and Comments UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH ME SURED AT THE l,= --------------------------------------------- ---- - - G---------- BUILDING DEPT REPRESENTA-TT'�E: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 07-00001524 Date 5/24/07 Application pin number . . . 273812 ---------------------------------------------------------------------------- Special Notes and Comments PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS WINDOWS ADJACENT TO TUBS WITHIN 60" ABOV DRAIN HALL BE BUILDING DEPT REPRESENT,4r?1`SkE : APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE S'1ATIOk, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 4 Application Number . . . . . 07-00001524 Date 5/24/07 Application pin number . . . 273812 ---------------------------------------------------------------------------- Special Notes and Comments TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 598.00 598.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 598.00 598.00 .00 .00 BUILDING DE APPLICANT: _ - APPLICATION FOR BUILDING PERMIT f*. CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX T7840 CriyOF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX P!' nin-d-D=1op.eSernica WINW.CSTX.GOV r�r 0Fs UM�c.,:� DATE-1� `r/RCC REG APPLICATION m l - TEMP POLE ADDRESS/LOCATION: —7�407 !G17Ne k i LC C I C- LOT 4 1/ BLOCK 3 V SUBDIVISION 6A5 i LE 67ATe d SEC/PH —7 BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR ADDRESS: _ 4090 State Highway 6 South ELECTRICIAN: _ Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Tema GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) H NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: Conventional Framing , LESS SL.. R STRUCTURE USE: Single Family Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ NIA VALUATION: S /y 5 / 114 .20 1010TOTAL AREA: 2q 6y HEATED AREA: 24 4 -5 (Cost of Labor and Materials) /q X PUBLIC SEWER NUMBER OF BEDROOMS: 7 f SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: �7 SEWER TAP: JA WATER TAP: cx- §&' SLZE OTHER TAP: Srz-�j^( *EVP POLE P Ar- ! . GARAGE TYPE: SINGLE ATTACHED INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE �d TRIPLE Siding and/or Masonry Slab on Grade Composition 0 0 SIGNATURE OF APPLICANT: L l O For Stylecraft *If proposed work involves new commercial co structiLa.cade proveme is enovations to an existing commercial property building elevations are required. 000000ee0000eaoe0000e.00ea00000000Officialy YE rNO l Plans Examiner I -I zVho Zoning Official S lc� oK,ly dk 0'1 — �I iS �Ge.�u tic W/N E-"0'0t&W Kt&'C.ring Jnergy Code Compliance In orma on % Glazing of exterior walls 211 Insulation R value of exterior walls R13 / Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .40 / Glazing U-Factor .65 R value of ductwork R6 A/C SEER Rating 13 .- ✓� ,4 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# 0 07 — / q 7 DATE: BUILDING ADDRESS: o.2 q 0 ToNe 1e Cl e . I. Foundation Requirements- Minimum City Foundation Standards N A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated COOK Il. Framing: Floor, Wall, Ceiling and Roof Requirements NA109 A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans NA/ F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, rade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements &OK WOK A. Stairway Details JN~ 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NfiTJ 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi NAIMV B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NAO A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units) f B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements NArX A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NAW Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed OK "APPROVED PLANS PER IRC SECTION R106.3.1." "PLANS EXAMINER - /7-a'7 DATE REScheck Software Version 4.0.1 Compliance Certificate Project Title: 2350 Plan Report Date: 05/16/07 Data filename: \\STYLECRAFTI\Share\ACAD\RESCheck\2350.2443-2407 Stone Castle.rck Energy Code: 2006 IECC Location: College Station, Texas Construction Type: Single Family Conditioned Floor Area: 2443 ft2 Glazing Area Percentage: 21% Heating Degree Days: 1788 Climate Zone: 2 Construction Site: Owner/Agent: Designer/Contractor: College Station, TX 77845 Stylecraft Builders, Inc. Stylecraft Builders, Inc. 4090 SH 6 South 4090 SH 6 South College Station, TX 77845 College Station, TX 77845 979-690-1222 x120 979-690-1222 x120 ewivagg@stylecraft-builders.com ewivagg@stylecraft-builders.com Maximum SHGC: Your SHGC: 0.40 0.40 Wall 1: Wood Frame, 16" o.c.: 2486 Window 1: Metal Frame:Double Pane with Low-E: 8 SHGC: 0.40 Window 2: Metal Frame:Double Pane with Low-E: 18 SHGC: 0.40 Window 3: Metal Frame:Double Pane with Low-E: 10 SHGC: 0.40 Window 4: Metal Frame:Double Pane with Low-E: 4 SHGC: 0 40 Window 5: Metal Frame:Double Pane with Low-E: 20 SHGC: 0.40 Window 6: Metal Frame:Double Pane with Low-E: 8 SHGC: 0.40 Window 7: Metal Frame:Double Pane with Low-E: 10 SHGC: 0.40 Window 8: Metal Frame:Double Pane with Low-E: 4 SHGC: 0.40 Window 9: Metal Frame: Double Pane with Low-E: 8 SHGC: 0.40 Window 10: Metal Frame: Double Pane with Low-E: 8 SHGC: 0.40 Window 11: Metal Frame:Double Pane with Low-E: 8 SHGC: 0.40 Window 12: Metal Frame:Double Pane with Low-E: 18 SHGC: 0.40 Window 13: Metal Frame:Double Pane with Low-E: 18 SHGC: 0.40 Window 14: Metal Frame:Double Pane with Low-E: 18 SHGC: 0.40 Window 15: Metal Frame:Double Pane with Low-E: 18 SHGC: 0.40 Window 16: Metal Frame:Double Pane with Low-E: 18 2350 Plan 13.0 0.0 159 0.670 5 0.670 12 0 670 7 0.670 3 0.670 13 0.670 5 0.670 7 0.670 3 0.670 5 0.670 5 0.670 5 0.670 12 0.670 12 0 670 12 0.670 12 0.670 12 Page 1 of 2 SHGC: 0.40 Window 17: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 18: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 19: Metal Frame -Double Pane with Low-E: SHGC: 0.40 Window 20: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 21: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 22: Metal Frame: Double Pane with Low-E: SHGC: 0.40 Window 23: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 24: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 25: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 26: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 27 Twin: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 27 Twin: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 28: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 29: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 30: Metal Frame: Double Pane with Low-E: SHGC: 0.40 Door 1: Solid: Door 2: Glass: SHGC: 0.40 Ceiling 1: Flat Ceiling or Scissor Truss: Floor 1: Slab -On -Grade: Unheated: Insulation depth: 0.0' Furnace 1: Forced Hot Air: 80 AFUE Air Conditioner 1: Electric Central Air: 13 SEER 28 28 28 28 28 28 18 18 18 6 16 16 16 6 18 38 18 2443 223 30.0 0.0 0.0 0.670 19 0.670 19 0.670 19 0.670 19 0.670 19 0.670 19 0.670 12 0.670 12 0.670 12 0.670 4 0.670 11 0.670 11 0.670 11 0.670 4 0.670 12 0.500 19 0.440 8 86 232 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2006 IECC requirements in REScheck Version 4.0.1 and to comply with the mandatory requirem d in the REScheck Inspection Checklist. "iLAonzA Pj— r5v1&or.--Y2,S )Z- Name - Title Signatu L Dat Project Notes: All U-Factors and SHGC are at entered at higher than actual amounts. Actual amounts are lower, but are entered higher to account for differences in ratings per material. 2350 Plan Page 2 of 2