Loading...
HomeMy WebLinkAboutADDN2007-01491 800 SOUTHERN HILLS CT BUILDING PERMITBUILDING PERMIT CITY OF COLLEGE STATION It O l 'fEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #. Tenant nbr, name . . . . . . Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . Owner ------------------------ LOCKETT, WILLIAM R & ANNE 800 SOUTHERN HILLS CT COLLEGE STATION TX 77845 --- Structure Information Construction Type . . Occupancy Type . . . Other struct info . . 000 07-00001491 Date 5/18/07 118864 800 SOUTHERN HILLS CT 497900-0009-0330 R92946 PLAYROOM OVER GARAGE RESIDENTIAL, ADDITION PEBBLE CREEK RESIDENTIAL SINGLE FAMILY RESIDENTIAL 60000 Contractor ------------------------ �FIidEF� oos 000 ADDITION COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX EXTERIOR WALL TYPE IMPACT/PRORATA FEES PAID FOUNDATION TYPE TYPE OF GARAGE (ATT/DET) BRICK NA JOIST NA HEATED AREA 700.00 INTERIOR WALL TYPE SHEETROCK SEWER TYPE PUBLIC TAZ 419.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit pin number . 503037 Permit Fee . . . . 300.00 Plan Check Fee .00 Issue Date . . . . 5/18/07 Valuation . . . . 60000 Expiration Date . . 11/14/07 Qty Unit Charge Per Extension BASE FEE 260.00 10.00 4.0000 THOU BLDG, VAL 50001-100000 40.00 ---------------------------------------------------------------------------- Special Notes and Comments Make sure that Floor and Ceiling joists are properly sized. Garage ceiling must have 5/8" Type X sheetrock when there is Habitable space above the garage. If keeping existing 1/2" on ceiling then you must add another layer of 1/211 - ----------------------------------------------- ------ ------------------- BUILDING DEPT REPRRE,SSEN ATIVE: APPLICANT: ���✓! % _ . BUILDING PERMIT CITY OF COLLEGE STATION 1,101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 07-00001491 Date 5/18/07 Application pin number . . . 118864 ---------------------------------------------------------------------------- Special Notes and Comments sheetrock. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS Interconnect new smoke detectors and existing detectors in the rest of the house. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC) ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING BUILDING DEPT REP„R�yNTJTIVE : APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1,101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 07-00001491 Date 5/18/07 Application pin number . . . ---------------------------------------------------------------------------- 118864 Special Notes and Comments DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid ---------- Credited Due -------------------- ----------------- Permit Fee Total 300.00 300.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 300.00 300.00 .00 .00 --------------------------------------------L --- ---- ---'-------------- BUILDING DEPT RE, jRE SENT,.ATIVE : 9 - APPLICANT: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning 6,DiwelapmentSerwes WWW CSTX.GOV For OBoe U" 0* DATE:�1-91 TRCC REG APPLICATION # TEMP POLE # ADDRESS/LOCATION: OO Sa64� �- - I `L, L LOT BLOCKS SUBDIVISION Pr N hIC (�o ! I SEC/PH--3 C BUSINESS/OWNER NAME: 6n I k� �-M.t�, lrc�C,L� PHONEj:�� ,55 S — J 27 CONTRACTOR/HOMEOWNER: C..c-i c bso I �PHOn1E' t CONTRACTOR ADDRESS: 't(Lbq ELECTRICIAN: C4, L c.It— PLUMBER: C�V 'Jof HVAC: M Oct(--S GOOD CENTS (Residential only): AAP CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ON O DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans EMODEL/RENOVATION* SWIMMING POO� r Required) / s DESCRIPTION OF WORK: �� kwC,��C �� Jrt q <,�r� r' 'G r✓� Cl STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHACTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: _�! /S__ TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ (,o� OC 6 TOTAL AREA: HEATED AREA: (Cost of Lab r and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: ❑ SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: SEWER TAP: WATER TAP: OTHER TAP: TEMP POLE GARAGE TYPE SIZE SIZE SIZE SINGLE ATTACHED n INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE D TRIPLE CARPORT f �%Yr•UdS i MI SIGNATURE OF APPLICANT: (' yi If proposed work involves new commercial construction or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only Comments: 47 --o 72 1 YES or NO Plans Examiner Zoning Official 4 it)40�+- Q 4J G� -- z� ram 000A, lie W Pry "A, 7a'-f+- 5, Le 4- s0.1 441, C*49 7- u ` �/ 1 Voj 4a & �e %Pi X d$, AOV / 14- 6✓'W t Xil TYrf� at/Am" �A Energy Code Compliance Information % Glazing of exterior walls 1 V 0/0 Insulation R value of exterior walls t '`13 Insulation R value of ceiling 1 (flat areas) � ` 3 D Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC , r Glazing U-Factor . 1,,C) R value of ductwork (L to A/C SEER Rating 13 r(5/11/2007) Kim Wolfe -800 Southern Hills Ct. - Page 1 " From: "chuckpye" <thepyes@verizon.net> To: <kwolfe@cstx.gov> Date: 5/11/2007 1:25 PM Subject: 800 Southern Hills Ct. Attachments: Front Elevation.tif; 3D View front.pdf CC: <thepyes@verizon.net> Kim, You can call me at 571-0250 if you have any questions. Chuck ----- Original Message ----- From: Bill Lockett To: chuckpye Sent: Friday, May 11, 2007 10:48 AM Subject: picture Sorry, I had to re -install Punch and reprint it to image. V-0" PLATE LINE_ — — SECOND FLOOR LINE q'-O" PLATE LINE FINISHED FLOOR LINE /07)i —8'-0" PLATE LINE QD QD SECOND FLOOR LINE A lD cn N w W m Lo W r q'-0" PLATE LINE o m FINISHED FLOOR LINE FRONT ELEVATION m D G) m m m low TOX&M t � ANY Io-fpt T Y l ,:� •`&�" M^t �•YT u 2.lrym. �-1+" 4 aOL .. $q d k r� ✓6 F f �w 27' -8" Z0/10 39dd 113>00-1 66866TS69P 61:90 900Z/0E/90 3'-7 1/2" 22'-II" -4 4,-8" 3'-7 I/2" _ 2'-4" 0 3046 RT I Ir I SHELF NC FLM4ngR-y 4d I UNHEATED SPACE 10 I I —_J I C �o -SHELF GAME foot - r I X 14'-1" CEILING, FLOOR: (Y Z Go N 11 -- I ° 90 �.� w� 1 I z IN z N I FieciQuj ri ZI- ., o LLI _.... cv° a m I m 0 WALL HEIGHT 41-011 R�g I .B — TWIN SH 1 -p" 7'-I 1/2u _ 11