HomeMy WebLinkAboutRES2007-01484 3923 LATINNE LN BUILDING PERMITWF0902399 / 001 City of College Station
PAGE 1
REQ. DATE: 05/15/07 05/15/07 11:24:12
LOCATION: 3923 LATINNE LN LOC ID: 208902
REQUESTOR: B A CATHEY ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 05/15/07 SCHED COMPLETION: 05/15/07
********************************************************************************
JOB ORDER RESULT COMMENTS
PREPARED 8/23/07, 8:07:17
INSPECTION TICKET PAGE 16
City of
College Station
INSPECTOR: BUILDING INSPECTOR DATE 8/22/07
------------------------------------------------------------------------------------------------
ADDRESS
. : 3923 LATINNE LN
SUBDIV: EDELWEISS GARTENS PH 7
CONTRACTOR B A CATHEY
PHONE (979) 255-7064
OWNER
. .
PHONE
PARCEL
. . 244030-0715-0380
APPL NUMBER: 07-00001484 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
5/23/07 OC
BLDG, FOUNDATION -SLAB TIME: 17:00
5/23/07 AP
May 23, 2007 1:10:45 PM glsouth.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01
6/18/07 RH
BLDG, FRAMING TIME: 17:00
6/18/07 DP
June 18, 2007 9:40:09 AM acarter.
06/18/2007 05:58 PM RH PDA
Need inte for bracing in front bedroom. Add more support
to valley and ridge at front bedroom. Joist hanger in
middle bedroom. Need support for back rafters, cannot
brace off of stiffback. Add support for valley at garage /
front entry. Splice for apa sheathing at garage must be
within 2ft of mid height.
B115 02
6/19/07 OC
BLDG, FRAMING TIME: 17:00
6/19/07 AP
June 19, 2007 8:27:50 AM acarter.
B130 01
6/22/07 OC
BLDG, INSULATION TIME: 17:00
6/22/07 AP
June 21, 2007 2:49:28 PM bkorthauer.
B125 01
8/22/07 B
BLDG, FINAL TIME: 17:00
August 22, 2007 4:28:02 PM acarter.
-------------------
----,f)------
----- COMMENTS AND NOTES --------------------------------------
�J
�l Olt acts f�l� c�
Date: 8/23/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1484
Address: 3923 LATINNE LN
Type
Inspection Type Code
Description
status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
06/18/2007 05:58 PM RH PDA
B115
BLDG, FRAMING
IC
Need inte for bracing in front bedroom. Add more support
B115
BLDG, FRAMING
IC
to valley and ridge at front bedroom. Joist hanger in
B115
BLDG, FRAMING
IC
middle bedroom. Need support for back rafters, cannot
B115
BLDG, FRAMING
IC
brace off of stiffback. Add support for valley at garage /
B115
BLDG, FRAMING
IC
front entry. Splice for apa sheathing at garage must be
B115
BLDG, FRAMING
IC
within 2ft of mid height.
E110
ELEC, ROUGH IN
IC
06/14/2007 11:04 AM RH PDA
E110
ELEC, ROUGH IN
IC
Wires for exterior plug at front door needs to be
E110
ELEC, ROUGH IN
IC
installed in appropriate box. Smoke detectors needed
E110
ELEC, ROUGH IN
IC
outside bedrooms.
Page 1
N51 11'22"E-61.34'
1 LOT 3 8, BLOCK 1 t
EVELWEISS GARTENS, PHASE I
9 9'-1 O"
i
5' UILDING LINE
1
I I 1
I I
1 � I
I � �
I I
I
I I I
1 II I
I I I
I I lift
I �
O
Y11 d I I la W
1't
W
0 all I Id)
a,
r I I 1
z II I I I
I I I I I
I I I I
I I I I
J
25 BUILDING LINE
1 �
WIDE JNALK
in
n � /
U
18' WIDE DRIVE
N 5 1 1 1' 22" E- 44.0'1'
LATINNE LANE
2
SITE PLAN
1.1. 1 O'-O"
i Amber Carter - Re: Calling for C.O. for 3923 Latinne Ln
From: Paul Schoenfeld
To: Amber Carter; Benjamin McCarty; Chris Haver; ...
Date: 8/23/2007 3:47:28 pm
Subject: Re: Calling for C.O. for 3923 Latinne Ln
All ok.
Paul
>>> Amber Carter 8/23/2007 8:26 AM >>>
by # 07-1484
Any issues?
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEX�r" E
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
07-00001484
545536
3923 LATINNE LN
244030-0715-0380
Date 5/15/07
RESIDENTIAL, 1 UNIT DETACHED NEW
EDELWEISS GARTENS PH 7
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
109164
Owner
Contractor
------------------------
------------------------
B A CATHEY
PO BOX 9517
COLLEGE STATION
TX 77842
(979) 255-7064
--- Structure Information
000 000 SINGLE FAMILY
Construction Type .
. . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . .
. . . . RESIDENTIAL-SFR/DUPLEX
Other struct info .
. . . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1634.00
INTERIOR WALL TYPE
GYPSUM
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
GS
Permit pin number .
502385
Permit Fee . . . .
490.00 Plan Check Fee
.00
Issue Date . . . .
5/15/07 Valuation . .
. . 109164
Expiration Date . .
11/11/07
Qty Unit Charge Per Extension
BASE FEE 460.00
10.00 3.0000 THOU BLDG, VAL 100001-500000 30.00
----------------------------------------------------------------------------
Special Notes and Comments
Narrow Wall Bracing Fully Sheathed with 16" Minimum APA
Garage Framing and Interior Anchors and Bring o h Right
------------------------------------------ ---------------------
BUILDING DEPT RE NTATIVE:
APPLICANT: �'
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS ANTE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00001484
Application pin number . . . 545536
Page 2
Date 5/15/07
Special Notes and Comments
of Front Door.
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT ST BE ISSUED PRIOR
-----------
-
------------------------------------------- ---
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00001484 Date 5/15/07
Application pin number . . . 545536
----------------------------------------------------------------------------
Special Notes and Comments
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFaICIT OF ALL GLAZED---------------------------------------------------------
BUILDING DEPT REP�SENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 4
Application Number . . . . . 07-00001484 Date 5/15/07
Application pin number . . . 545536
----------------------------------------------------------------------------
Special Notes and Comments
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP
4"
350.00
WATER TAP
3/4"
400.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid
----------
Credited
--------------------
Due
-----------------
Permit Fee Total
490.00
490.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1240.00
1240.00
.00
.00
-- --------------------- `�J -- --.--'------------
BUILDING DEPT REPRESENTATIVE:---` -
APPLICANT: rlel-z'
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
07-00001485
627440
3923 LATINNE LN
244030-0715-0380
Date 5/15/07
TEMP POLE
EDELWEISS GARTENS PH 7
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Owner
Contractor
------------------------
------------------------
B A CATHEY
PO BOX 9517
COLLEGE STATION
TX 77842
(979) 255-7064
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. GS
Permit pin number
. 502393
Permit Fee . . .
. 20.00
Issue Date . . .
. 5/15/07
Valuation . . .
. 0
-----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
-------------------------------------------- ---- -----------
BUILDING DEPT R SENTATIVE:
APPLICANT: .1.4
(*t/4"
CITY OF COLLEGE STATION
Planning er Development Seevicei
ADDRESS/LOCATION
LOT � BLOCK I
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
a3 I-g7-1AtAXr
For Office Use Only
DATE: 6_((I1 `1 TRCC REG
APPLICATION #' — WKk
TEMP POLE #
SUBDIVISION `���Z-�/✓� J SEC/PH
BUSINESS/OWNER NAME: �G.A-/C� PHONE: `5�-- �o
i
CONTRACTOR/HOMEOWNER: PHONE: 1�75—
CONTRACTOR ADDRESS: gat q -/ -7 6'O I/EL�
ELECTRICIAN.: DB PLUMBER:
HVAC: �A-IZlG�I�..� GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING LL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION " LAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL
/ TENT/CANOPY
DESCRIPTION OF WORK: /"�W 1*"6
PROPOSED USE: � CI5 ,T -__ �' - _ jj:�>'-
HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ TOTAL AREA: 22401' HEATED AREA: (403�
(Cost of Labor andMaterials)
PBLIC SEWER NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM
SEWER TAP: f
3IZE
WATER TAP:
SIZE
OTHER TAP:
(ESIZE
MP POLE
GARAGE TYPE: SINGLE
ATTACHED Fol,
NUMBER OF BATHROOMS
INTERIOR WALL TYPE
EXTERIOR WALL TYPE
FOUNDATION TYPE
ROOF TYPE:
DOUBLE FVJ TRIPLE
IETACHED F7 CARPO
Z
G' y/Sd'*-1
-�;,4 e:/e-
fie:.45
0 & r ct7 VA A1G L 9'
SIGNATURE OF APPLICANT: '� 'o
*If proposed work involves new comm rcial construction or facade improve s/renovations to an existing
commercial property, building elevati ns are required.
Official Use Only
/� �'`�1 Plans Examiner Zoning Official
GoaW
Fu'llY Si 'AOA &4+taier ES oreNO
Fire Marshall
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls PZ 13
Insulation R value of ceiling 1 (flat areas) 1
Insulation R value of ceiling 2 (vaulted areas/no attic)
2-1 �
Glazing SHGC 0 /
Glazing U-Factor
R value of ductwork f �-
A/C SEER Rating /3 'S gyp.,
f
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 07 _ / u
1
DATE:
BUILDING ADDRESS:
Loa
I. Foundation Requirements- Minimum City Foundation Standards
NA/qFIV
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
K
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N O
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
O
E.
Header sizes indicated on plans
A/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
MOK
K
A. Stairway Details
K
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
NA/
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening ? 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NOT
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
NAIQV
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NA/
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NAW
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NA/
Does not block any water course or divert any flow
Elevation certificate needed
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
PLANS EXAMINER DATE