HomeMy WebLinkAboutRES2007-01483 2904 HORSEBACK CT BUILDING PERMITAmber Carter - Re: Calling for C.O. for 2904 Horseback Ct
Page 1
From: Terry Boriskie
To: Amber Carter; Benjamin McCarty; Chris Haver;
Date: 10/22/2007 3:14 pm
Subject: Re: Calling for C.O. for 2904 Horseback Ct
JC Wall has been notified of the needed repairs.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Paul Schoenfeld 10/22/2007 3:04 pm >>>
NO for CO
Sewer needs to be raised.
Water meter box broken.
Paul
>>> Amber Carter 10/22/2007 12:08 PM >>>
by 07-1483
Any issues?
TREANY10
10/19/07,
12:04:49
INSPECTTON 7ICKET PAGE 5
City of
College Station
INSPECTOR: BUILDING INSPECTOR DATE 10/19/07
------------------------------------------------------------------------------------------------
Y
ADDRESS
2.9,04 HORSEBACK CT
SUBDIV: HORSE HAVEN PH 3
CONTRACTOR
NEW AMERICAN DREAM
PHONE (254) 853-2760
OWNER .
.
PHONE :
PARCEL .
. 336300-0302-0190
ABPL NUMBER: 07-00001483
RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
'
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
6/01/07
DS
BLDG, FOUNDATION -SLAB TIME: 17:00
6/01/07
DP
June 1, 2007 10:25:58 AM glsouth.
June 1, 2007 4:11:50 PM kwolfe.
permit needs to be posted and no strings up on set backs
B100 02
6/04/07
DS
BLDG, FOUNDATION -SLAB TIME: 17:00
6/04/07
CA
June 1, 2007 4:12:31 PM kwolfe.
B100 03
6/06/07
JGM
BLDG, FOUNDATION -SLAB TIME: 17:00
6/06/07
DP
June 5, 2007 12:09:09 PM kwolfe.
06/06/2007 11:13 AM JGM PDA
need to cean beams (cave-ins) raise beam steel, need front
and rear strings on setbacks not on property line
B100 04
6/07/07
JGM
BLDG, FOUNDATION -SLAB TIME: 17:00
6/07/07
AP
June 6, 2007 2:42:26 PM kwolfe.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01
7/10/07
JGM
BLDG, FRAMING TIME: 17:00
7/11/07
DP
July 10, 2007 10:05:39 AM acarter.
July 11, 2007 11:46:15 AM kwolfe.
need interior anchors & bracing
need 24" minimum on garage return, needs engineer design oor
panels
correct purling bracing issues
B115 02
7/16/07
JGM
BLDG, FRAMING TIME: 17:00
7/16/07
AE
July 13, 2007 3:47:35 PM kwolfe.
07/16/2007 11:16 AM JGM PDA
need to complete interior bracing
B130 02
7/24/07
RH
BLDG, INSULATION TIME: 17:00
7/24/07
DP
July 24, 2007 12:30:16 PM acarter.
07/24/2007 04:40 PM RH PDA
Install x-bracing properly with proper nails and nailing
pattern. Do not use roofing nails. Tyvek must be installed
and sealed as per manufacture requirements.
B130 01
7/24/07
DS
BLDG, INSULATION TIME: 17:00
7/24/07
DP
July 23, 2007 1:55:00 PM: acarter.
07/24/2007 12:24 PM DS PDA
�V
Q
X-bracing not installed per other inspections
B130 03 7/25/07 RH BLDG, INSULATION TIME: 17:00
7/25/07 AP July 25, 2007 10:16:45 AM acarter.
B125 01 10/19/ 7 BI BLDG, FINAL TIME: 17:00
October 19, 2007 12:02:44 PM kwolfe.
------------------------------- CONTINUED ONTO NEXT PAGE -----------------------------------
Date: 10/26/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1483
Address: 2904 HORSEBACK CT
Insp.
Inspection Type Code
Description
status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
June 1, 2007 4:11:50 PM kwolfe.
B100
BLDG, FOUNDATION -SLAB
IC
permit needs to be posted and no strings up on set backs
B100
BLDG, FOUNDATION -SLAB
IC
06/06/2007 11:13 AM JGM PDA
B100
BLDG, FOUNDATION -SLAB
IC
need to cean beams (cave-ins) raise beam steel, need
B100
BLDG, FOUNDATION -SLAB
IC
and rear strings on setbacks not on property line
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
July 11, 2007 11:46:15 AM kwolfe.
B115
BLDG, FRAMING
IC
need interior anchors & bracing
B115
BLDG, FRAMING
IC
need 24" minimum on garage return, needs engineer
design oor
B115
BLDG, FRAMING
IC
panels
B115
BLDG, FRAMING
IC
correct purling bracing issues
B115
BLDG, FRAMING
IC
07/16/2007 11:16 AM JGM PDA
B115
BLDG, FRAMING
IC
need to complete interior bracing
B130
BLDG, INSULATION
IC
07/24/2007 12:24 PM DS PDA
B130
BLDG, INSULATION
IC
needs to insulate all portions of walls behind tubs
B130
BLDG, INSULATION
IC
X-bracing not installed per other inspections
B130
BLDG, INSULATION
IC
07/24/2007 04:40 PM RH PDA
B130
BLDG, INSULATION
IC
Install x-bracing properly with proper nails and nailing
B130
BLDG, INSULATION
IC
pattern. Do not use roofing nails. Tyvek must be installed
B130
BLDG, INSULATION
IC
and sealed as per manufacture requirements.
E150
ELEC, FINAL
IC
10/12/2007 04:43 PM JGM PDA
E150
ELEC, FINAL
IC
not ready
E150
ELEC, FINAL
IC
10/23/2007 11:49 AM JGM PDA
E150
ELEC, FINAL
IC
need disconnect for water heater, within appliance
M110
MECH, FINAL
IC
October 19, 2007 4:16:44 PM kwolfe.
M110
MECH, FINAL
IC
Primary drain needs to be properly installed
Page 1
WF0907544 / 001 City of College Sjation I IPAGE 1
REQ. DATE: 05/23/07 05/23/07 14:05:39
LOCATION: 2904 HORSEBACK CT LOC ID: 208626
REQUESTOR: NEW AMERICAN DREAM ORIGIN: CUSTOMER -WALK IN
REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE:
WTR 4" SWR 3/4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 05/23/07 SCHED COMPLETION: 05/23/07
********************************************************************************
JOB ORDER RESULT COM4ENTS
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
Owner . . . . . . . . .
Contractor . . . . . .
Application number
Description of Work
Construction type . . .
Occupancy type . . . .
Flood Zone . . . . . .
Approved
11/05/07
336300-0302-0190
2904 HORSEBACK CT
COLLEGE STATION TX 77845
HORSE HAVEN PH 3
HORSE HAVEN ESTATES PH 3, BLOC
K 2, LOT 19, ACRES 0.18
SINGLE FAMILY RESIDENTIAL
NEW AMERICAN DREAM LTD
NEW AMERICAN DREAM
254 853-2760
07-00001483 000 000
RESIDENTIAL, 1 UNIT DETACHED NEW
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
BujAlding Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
S761i
t q-3, iq
.L
J
2 SQL. , -.R
x
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION,,TX 7t1840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00001483 Date 5/23/07
Application pin number . . . 463632
Property Address . . . . . . 2904 HORSEBACK CT
Property ID: 336300-0302-0190
R 4:
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . HORSE HAVEN PH 3
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 105006
Owner
Contractor
------------------------
------------------------
NEW AMERICAN DREAM
PO BOX 390
MOODY
TX 76557
(254) 853-2760
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1591.00
INTERIOR WALL TYPE
DRYWALL
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TAZ
285.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
MA
Permit pin number .
504019
Permit Fee . . . .
478.00 Plan Check Fee
.00
Issue Date . . . .
5/23/07 Valuation . .
. . 105006
Expiration Date . .
11/19/07
Qty Unit Charge
Per
Extension
BASE FEE
460.00
6.00 3.0000
THOU BLDG, VAL 100001-500000
18.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN RC-FAU T CIRCUIT
BUILDINGrREPT REPRESEtL
ot
E:
APPLI
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION,,TX 7?1840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00001483
Application pin number . . . 463632
Page 2
Date 5/23/07
Special Notes and Comments
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
Be Aware of 20' Rear P.U.E.
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
No Return Air to be Taken from Garage.
Narrow Wall Bracing Fully Sheathed with Interior Anchors and
Bracing to the Left of Front Door Area.
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST E ISSU D PRIOR.
------------------------------------------------ A40"Zo --------
BUILDING D VPRES NT
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION,ITX 7'7840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00001483 Date 5/23/07
Application pin number . . . 463632
----------------------------------------------------------------------------
Special Notes and Comments
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF LL GLAZED
-------------------------------------------------------��------
BUILDING DFjXT PAPRESEN�TIy4
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION,°TX 7'7840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number . . . . . 07-00001483 Date
5/23/07
Application pin number . . . 463632
----------------------------------------------------------------------------
Special Notes and Comments
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
------------------------------
---------------------------
Permit Fee Total 478.00 478.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1228.00 1228.00 .00
.00
-------------------------------------------------- ------ - -----
BUILDINGrVEP'A REPRf $,FW-�AT'IqE :
APPLI
�j F-00—umQ*
1 APPLICATION FOR BUILDING, PERMIT DATE: ✓ TRCC REG
CITY OF COLLEGE STATION�f (�C�
1101 TEXAS AVENUE APPI (CATION#� 4
COLLEGE STATION, TX 77840 TEMP POLE #
CTyo'COLIXGcSTNI-ION (979) 764-3570 (979) 764-3496 FAX
W W W.CSTX.GOV
ADDRESS/LOCATION: 2109 140 9.6IIS14.K
LOT I9 afOCK A SUBDIVISION J A✓GA.1 64.11%r,L5 EC/PH
BUSINESS/OWNER NAME: .T, G . CJA Lj. PHONE.45-V 853- 270a
CONTRACTOR/HOMEOWNER: IJ-4. D . LT.D PHONE-. 251I/ 963- 274 e
CONTRACTOR ADDRESS: Pe Bob( 311,0, /(wavy lr-X- 745S7
ELECTRICIAN: Rjstw5n2Ljr�%G PLUMBER:
HVAC: RI GM,, am L oz jj s H (�j 12 GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: NrEa1 CaAJSTQIJGt/. _ 1�ESl.n�AlTI /�L
STRUCTURE USE: 51,j& &_
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
7PUBLIC
UATION: $ /o. �
Soe Ga Z TOTALAREA: 2� HEATEDAREA:(Cost of Labor and Materials)
SEWER NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: .Z
SEWER TAP: 14 I, INTERIOR WALL TYPE: woop/'a2yLn3LL.
SIZE
WATER TAP: 31q EXTERIOR WALL TYPE: WaaIQ /c,IL j11nMDI P4. f3A1s;
SIZE
OTHER TAP: FOUNDATION TYPE: C,► C.Ie C1 n
SIZE
TEMP POLE ROOF TYPE: (. a A>,P-S I fi a Ai SN 1AA-- L F_
GARAGE TYPE: SINGLE D BLE F—] TRIPLE
ATTACHE DEACHED V CARPORT F
SIGNATURE OF APPLICANT:
*If proposed work involves neweat
commercial property, buildinge
;ial construction or facade improvements/renovations to an existing
are required.
Official Use Only
r Plans Examiner
C_kws Add
w\A v! i-t v,j l 4f v" 01
Zoning Official
C ments-
ES r NO
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling I (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
/a o
T-l3
36 /
--
a
REScheck Software Version 4.0.1
Compliance Certificate
Project Title: Spec House
Report Date: 05/07/07
Data filename: C:\Documents and Settings\J C Wall Const\My DocumentsUudy\Reschek 4.1\2904 Horseback 1591 sq ft.rck
Energy Code:
2000 IECC
Location:
College Station, Texas
Construction Type:
Single Family
Glazing Area Percentage:
9%
Heating Degree Days:
1788
Construction Site:
Owner/Agent:
Designer/Contractor:
2904 Horseback Court
J.C. Wall
N.A.D. Ltd
College Station, TX 77845
PO Box 390
Moody, TX 76557
254 853-2760
o iian ass :ax mu 413 i 1 —259 34.9°o Bet R-AT an Cacf A}
Maximum SHGC: 0.40 r
.37
Gross Cavity Cont. Glazing UA
Assembl Area or R-Value R-Valu or Doo
Perimete U_F,�a_cto
Ceiling 1: Flat Ceiling or Scissor Truss: 1591
30.0
0.0 56
Wall 1: Wood Frame, 16" o.c.: 1706
13.0
0.0 124
Window 1: Metal Frame with Thermal Break:Double Pane with 132
0.530 70
Low-E:
SHGC: 0.37
Door 1: Solid: 38
0.230 9
Door 2: Glass: 18
0.550 10
SHGC: 0.37
Furnace 1: Forced Hot Air: 78 AFUE
Air Conditioner 1: Electric Central Air. 13 SEER
Compliance Statement. The proposed building design described her is consistent
th the building plans, specifications, and other
calculations submitted with the permit application. The proposed b d ng has been d signed to
et the 2000 IECC requirements in
REScheck Version 4.0.1 and to comply with the mandatory requir m is I� i th
RES a
nspection Checklist.
I -(.'- — .WALL ��- I M6 NT
Name - Title ature
Date
Project Notes:
Lot 19, Block 2, Horse Haven Estates, Phase III
Spec House
Page 1 of 1
REScheck Software Version 4.0.1
Inspection Checklist
Date: 05/04/07
Ceilings:
❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
Above -Grade Walls:
❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
❑ Wall 2: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
❑ Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.530
For windows without labeled 1-1-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Doors:
❑ Door 1: Solid, U-factor: 0.230
Comments:
❑ Door 2: Glass, U-factor: 0.550
Comments:
Heating and Cooling Equipment:
❑ Furnace 1: Forced Hot Air: 78 AFUE or higher
Make and Model Number:
❑ Air Conditioner 1: Electric Central Air: 13 SEER or higher
Make and Model Number.
Solar Heat Gain Coefficient:
❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values are determined in
accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed.
❑ Recessed lights are 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from
combustible materials. If non -IC rated, fixtures are installed with a 3" clearance from insulation.
Materials Identification:
❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions.
❑ Materials and equipment are identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
❑ Insulation R-values and glazing U-factors are clearly marked on the building plans or specifications.
❑ Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a
manner that achieves the rated R-value without compressing the insulation.
Duct Insulation:
Spec House Page 2 of 4
❑ Ducts in unconditioned spaces are insulated to R-5. Ducts outside the building are insulated to R-8.0
Duct Construction:
All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric,
or tapes. Tapes and mastics are rated UL 181A or UL 181B.
Exceptions:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa).
Ll The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or
cooling input to each zone or floor is provided.
Service Water Heating:
Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat
trap or is part of a circulating system.
Circulating hot water pipes are insulated to the levels in Table 1.
Circulating Hot Water Systems:
Circulating hot water pipes are insulated to the levels in Table 1.
Swimming Pools:
❑ All heated swimming pools have an ontoff heater switch and a cover unless over 20% of the heating energy is from non-depletable
sources. Pool pumps have a time clock.
Heating and Cooling Piping Insulation:
HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
Spec House Page 3 of 4
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non -Circulating Runouts Circulating Mains and Runouts
Temperature ("F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-169 0.5 0.5 1.0 1.5
100-139 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes
Insulation Thickness in Inches by Pipe Sizes
Piping System Types
Fluid Temp.
Range ff)
2" Runouts 1" and Less
1.25" to 2.0" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant and
40-55
0.5
0.5
0.75
1.0
Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD: (Building Department Use Only)
Spec House Page 4 of 4
a,
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# O ,7 _ 11183
y83
DATE:
BUILDING ADDRESS:
aqv'-1 go 21ebc. c,k Of -
I. Foundation Requirements- Minimum City Foundation Standards
NA/
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
VOK
II. Framing:
Floor, Wall, Ceiling and Roof Requirements
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
RNbK
E.
Header sizes indicated on plans
NAM
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, rade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
r
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
Ill. Stairway Requirements
OK
K
A. Stairway Details
OK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
K
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/
!7)
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
Cy
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/ I(
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NAVIg
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
- & 0-7
'PrANS EXAMINER DATE