Loading...
HomeMy WebLinkAboutRES2007-01482 2906 HORSEBACK CT BUILDING PERMIT6 City of College SLation INSPECTOR: BUILDING INSPECTOR DATE !C/25/07 ADDRESS . : 2906 HORSEBACK CT SUBDIV: HORSE HAVEN PH 3 CONTRACTOR NEW AMERICAN DREAM PHONE : (254) 853-2760 OWNER . . PHONE : PARCEL . . 336300-0302-0180 APPL NUMBER: 07-00001482 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT_ BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS _-Z --------------------------------------------------------------------------------------------- B100 01 6/01/07 DS BLDG, FOUNDATION -SLAB TIME: 17:00 6/01/07 CA June 1, 2007 10:25:43 AM glsouth. June 1, 2007 4:12:55 PM kwolfe. B100 02 6/04/07 DS BLDG, FOUNDATION -SLAB TIME: 17:00 6/04/07 CA June 1, 2007 4:13:11 PM kwolfe. B100 03 6/06/07 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 6/06/07 AP June 5, 2007 12:09:32 PM kwolfe. 06/06/2007 11:17 AM JGM PDA need to clean beams (cave-ins) raise beam steel, need rear and front string on setbacks B115 01 7/10/07 JGM BLDG, FRAMING TIME: 17:00 7/11/07 DP July 10, 2007 10:06:01 AM acarter. July 11, 2007 11:46:33 AM kwolfe. need interior anchors & bracing need 24" minimum on garage return, needs engineer design oor panels correct purling bracing issues B115 02 7/16/07 JGM BLDG, FRAMING TIME: 17:00 7/16/07 AE July 13, 2007 3:47:55 PM kwolfe. 07/16/2007 11:16 AM JGM PDA need to complete interior bracing B130 01 7/24/07 RH BLDG, INSULATION TIME: 17:00 7/24/07 DP July 24, 2007 12:37:51 PM acarter. 07/24/2007 04:36 PM RH PDA Did not install interior bracing as previously noted. Tyvek needs to be installed and sealed as per manufacture requirements. B130 02 7/25/07 RH BLDG, INSULATION TIME: 17:00 7/25/07 AP July 25, 2007 10:17:11 AM acarter. B125 01 10/19/07 JGM BLDG, FINAL TIME: 17:00 10/19/07 DP October 19, 2007 12:C4:01 PM kwolfe- October 19, 2007 4:22:50 PM kwolfe. tmp drain is below grade , L need prooer dra_nacre `,c stab /j^y�l�� ,UA B125 02 .C/25/C7 B'.DG, ItiA "TvD. :7, L j�✓- �(ih'�� Date 10/26/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 1482 Address: 2906 HORSEBACK CT Type Inspection Type Code Description Status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC June 1, 2007 4:12:55 PM kwolfe. B100 BLDG, FOUNDATION -SLAB IC 06/06/2007 11:17 AM JGM PDA B100 BLDG, FOUNDATION -SLAB IC need to clean beams (cave-ins) raise beam steel, need B100 BLDG, FOUNDATION -SLAB IC and front string on setbacks B115 BLDG, FRAMING IC July 11, 2007 11:46:33 AM kwolfe. B115 BLDG, FRAMING IC need interior anchors & bracing B115 BLDG, FRAMING IC need 24" minimum on garage return, needs engineer design oor 13115 BLDG, FRAMING IC panels 13115 BLDG, FRAMING IC correct purling bracing issues 13115 BLDG, FRAMING IC 07/16/2007 11:16 AM JGM PDA 13115 BLDG, FRAMING IC need to complete interior bracing B125 BLDG, FINAL IC October 19, 2007 4:22:50 PM kwolfe. B125 BLDG, FINAL IC tmp drain is below grade B125 BLDG, FINAL IC need proper drainage from slab B130 BLDG, INSULATION IC 07/24/2007 04:36 PM RH PDA B130 BLDG, INSULATION IC Did not install interior bracing as previously noted. B130 BLDG, INSULATION IC Tyvek needs to be installed and sealed as per manufacture B130 BLDG, INSULATION IC requirements. E150 ELEC, FINAL IC October 11, 2007 4:44:01 PM kwolfe. E150 ELEC, FINAL IC bond meter can E150 ELEC, FINAL IC short in panel E150 ELEC, FINAL IC clamp on A/C whip M110 MECH, FINAL IC October 19, 2007 4:18:50 PM kwolfe. M110 MECH, FINAL IC Primary drain needs to be properly installed Page 1 Amber Carter - Re. Calling for CO @ 2906 Horseback Ct From: Terry Boriskie To: Amber Carter; Benjamin McCarty; Chris Haver; Date: 10/22/2007 9:25 am Subject: Re: Calling for CO @ 2906 Horseback Ct IC Wall has been notified about the need to raise the sewer clean out box. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Paul Schoenfeld 10/19/2007 3:55 pm >>> NO for CO Water ok. Sewer buried. Paul >>> Kim Wolfe 10/19/2007 1:37 PM >>> any issues? BP # 07-1482 Thanks Kimberly Wolfe, CPS/CAP City of College Station Planning & Development Services (979)764-3570 www.cstx.4ov (10/22/2007) Gina Southerland - Re: Calling for CO @ 2906 Horseback CtT Page 1 From: Terry Boriskie To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; JC Wa... Date: 10/22/2007 9:25 AM Subject: Re: Calling for CO @ 2906 Horseback Ct JC Wall has been notified about the need to raise the sewer clean out box. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Paul Schoenfeld 10/19/2007 3:55 pm >>> NO for CO Water ok. Sewer buried. Paul >>> Kim Wolfe 10/19/2007 1:37 PM >>> any issues? BP N 07-1482 Thanks Kimberly Wolfe, CPS/CAP City of College Station Planning & Development Services (979)764-3570 www.cstx.gov WF0907549 / 001 City of College Station PAGE REQ. DATE: 05/23/07 05/23/07 14:06:46 LOCATION: 2906 HORSEBACK CT LOC ID: 208628 REQUESTOR: NEW AMERICAN DREAM ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 4" SWR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 05/23/07 SCHED COMPLETION: 05/23/07 ******************************************************************************** JOB ORDER RESULT COMMENTS City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . Owner . . . . . . . . . Contractor . . . . . . Application number Description of Work Construction type . Occupancy type . . . Flood Zone . . . . . Approved . . 11/05/07 336300-0302-0180 2906 HORSEBACK CT COLLEGE STATION TX 77845 HORSE HAVEN PH 3 HORSE HAVEN ESTATES PH 3, BLOC K 2, LOT 18, ACRES 0.17 SINGLE FAMILY RESIDENTIAL NEW AMERICAN DREAM LTD NEW AMERICAN DREAM 254 853-2760 07-00001482 000 000 RESIDENTIAL, 1 UNIT DETACHED NEW COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX B gilding Official VOID UNLESS SIGNED BY BUILDING OFFICIAL 1 � r ` � (� i BUILDING PERMIT CITY OF COLlnEGE �3TATION 1101 TEXAS= AVE r - COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- t Application Number . . . . . 07-00001482 Date 5/23/07 Application pin number . . . 381728 Property Address . . . . . . 2906 HORSEBACK CT Property ID: 336300-0302-0180 R #: Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . HORSE HAVEN PH 3 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 91476 Owner Contractor ------------------------ ------------------------ NEW AMERICAN DREAM PO BOX 390 MOODY TX 76557 (254) 8 5 3 - 2 7 6 0 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1386.00 INTERIOR WALL TYPE DRYWALL NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 285.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . MA Permit pin number . 504035 Permit Fee . . . . 428.00 Plan Check Fee .00 Issue Date . . . . 5/23/07 Valuation . . . . 91476 Expiration Date . . 11/19/07 Qty Unit Charge Per Extension BASE FEE 260.00 42.00 4.0000 THOU BLDG, VAL 50001-100000 168.00 ---------------------------------------------------------------------------- Special Notes and Comments Be Aware of 20' Rear P.U.E. ----------------------------------------------------------- BUILDINGAEPTnREPRESENTATIVE: IV• - APPLICANT- BUILDING PERMIT CITY OF COLLEGE UTATION 1101 TEXAS AVE' r COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 07-00001482 Date 5/23/07 Application pin number . . . 381728 ---------------------------------------------------------------------------- Special Notes and Comments No return air taken from garage Narrow Wall Bracing Fully Sheathed with Interior Anchors and Bracing to the Right of Front Door. ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MU BE ISSUED PRIOR ---------------------------------------------- ------------- BUILDING J\PT AEPRESEI�ATIVE APPLICANT BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE ' COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 07-00001482 Date 5/23/07 Application pin number . . . 381728 ---------------------------------------------------------------------------- Special Notes and Comments TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIEN OF AL GLAZED_ ----------------- BUILDIN EPTJIRE�RE�N��IJ� _ APPLI BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE ' COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 4 Application Number . . . . . 07-00001482 Date 5/23/07 Application pin number . . . 381728 ---------------------------------------------------------------------------- Special Notes and Comments FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid ---------- Credited -------------------- Due ----------------- Permit Fee Total ---------- 428.00 428.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1178.00 1178.00 .00 .00 BUILDING PT r SEN TAPPLICANT TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 07-00001582 885002 2906 HORSEBACK CT 336300-0302-0180 Date 5/23/07 TEMP POLE HORSE HAVEN PH 3 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Owner Contractor ------------------------ ------------------------ NEW AMERICAN DREAM PO BOX 390 MOODY TX 76557 (254) 853-2760 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . MA Permit pin number . 504068 Permit Fee . . . . 20.00 Issue Date . . . . 5/23/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 --------------------------------------------- -- - +---------- BUILDINGNEPA RP} PRE �TT�IV,', APPLI r- Off— U" aNa •r ' APPLICATION FOR BUILDING PERMIT DATE:✓� I " I TRCC REG CITY OF COLLEGE STATION _1 a 1101 TEXAS AVENUE APPLICATION# COLLEGE STATION. TX 77840 TEMP POLE # 007 r CITI 01' 011111CL S'lNI'wN' (979) 764-3570 (979) 764-3496 FAX W W W.CSTX_GOV ADDRESS/LOCATION: :21.4 dogbGaRGC itfeu r LOT/BLOCK :2 `' SUBDIVISIONh(.oeSr /'/�✓G.t/ ►�Sial�LV SEC/PH lil BUSINESS/OWNER NAME: -?. G (J PHONE: ,15'/ 853- 2 -Ae, tjgvj ^neitIC46W CONTRACTOR/HOMEOWNER: D . Lr> PHONE:.2S'/ 963- 276 6 CONTRACTOR ADDRESS: Po Bob( 34d, MagV ELECTRICIAN: /1GN5n2t,t nJct PLUMBER: HVAC: awts J&or d 19 I(L GOOD CENTS (Residential only): CLASS OF WORK A CCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTIONSLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION` SWIMMING POOL Required) DESCRIPTION OF WORK: AJP—d4J STRUCTURE USE: 1_1ArnjLy HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL TEXAS ACCESSIBILITY STANDARD (TASOJECT REGISTRATION# EABPRJ VA UATION: $ 9) y ?G . �m ✓ TOTAL AREA-.° 23 HEATED AREA: 3 S% (Cost of Labor and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: ? 3 SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: SEWER TAP: L „ INTERIOR WALL TYPE' W e e D SIZE WATER TAP: 31q EXTERIOR WALL TYPE: We• D / 3 & i C K_ /%1IAR a1lpL (*Mk SIZE �— OTHER TAP: FOUNDATION TYPE C• NGIC am - SIZE �^ TEMP POLE ROOF TYPE: Ira R►P-Si Iri d wJ SFI Ill fG LF, GARAGE TYPE: SINGLE DOUBLE F—] TRIPLE ATTACHED DOETAHj& CARPORT SIGNATURE OF APPLICANT: 'If proposed work involves new corn rcial construction or facade Improvements/renovations to an existing commercial property, building elev ions are required. Official Use Only ( Cy{� or NO Plans Examiner Zoning Official 46 + G Fj Cow p Lo c4rvw, �A Fur 1Na CO� 2/A � Al C Fv 11w 5ke, a j / i;A . etx Awavas A-4,0",sr 4 V. o f QaA- Enemy Code Compliance Information ` % Glazing of exterior walls Insulation R value of exterior walls - 13 Insulation R value of ceiling I (flat areas) 12 - -3 Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor ° • S8 / R value of ductwork A/C SEER Rating 13 REScheck Software Version 4.0.1 Compliance Certificate Project Title: Spec House Report Date: 05/04/07 Data filename: C:\Documents and Settings\J C Wall Const\My Documents`ludy\Reschek 4.1\2906 Horseback 1386 sq ft.rck Energy Code: 20001ECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 11% Heating Degree Days: 1788 Construction.Site: Owner/Agent: Designer/Contractor: 2906 Horseback Court J.C. Wall NA.D. Ltd College Station, TX 77845 PO Box 390 Moody, TX 76557 254 853-2760 Maximum SHGC: 0.40 Your SHGC: 0.37 Gross Cavity Cant. Glazing UA Assembl rea o R-Value -Valu or�Doo Perimeter UyFacto Ceiling 1: Flat Ceiling or Scissor Truss: 1386 30.0 0.0 49 Wall 1: Wood Frame, 16" o.c.: 1400 13.0 0.0 99 Window 1: Metal Frame:Double Pane with Low-E: 138 0.530 73 SHGC: 0.37 Door 1: Solid: 38 0.230 9 Door 2: Glass: 18 0.550 10 SHGC: 0.37 Furnace 1: Forced Hot Air: 78 AFUE Air Conditioner 1: Electric Central Air: 13 SEER Compliance Statement: The proposed building design described here is consi with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been d igned to meet the 2000 IECC requirements in REScheck Version 4.0.1 and to comply with the mandatory requ' ents listed in the ESchec In ction Checklist. J.li. Gil Puagi IJ)E NT O5 0 2ea7 Name - Title n ture Dat Project Notes: Lot 18, Block 2, Horse Haven Estates, Phase III Spec House Page 1 of 4 ciREScheck Software Version 4.0.1 1$( Inspection Checklist Date: 05/04/07 Ceilings: ❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: ❑ Window 1: Metal Frame:Double Pane with Low-E, U-factor. 0.530 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes - No Comments: Doors: ❑ Door 1: Solid, U-factor: 0.230 Comments: ❑ Door 2: Glass, U-factor: 0.550 Comments: Heating and Cooling Equipment: ❑ Furnace 1: Forced Hot Air: 78 AFUE or higher Make and Model Number. ❑ Air Conditioner 1: Electric Central Air: 13 SEER or higher Make and Model Number: Solar Heat Gain Coefficient: ❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values are determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: ❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ Recessed lights are 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, fixtures are installed with a 3" clearance from insulation. Materials Identification: ❑ Materials and equipment are installed in accordance with the manufacturers installation instructions. ❑ Materials and equipment are identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. ❑ Insulation R-values and glazing U-factors are clearly marked on the building plans or specifications. ❑ Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: ❑ Ducts in unconditioned spaces are insulated to R-5. Ducts outside the building are insulated to R-8.0. Duct Construction: SpecHouse__.,.�,_.._.._._,_...___....._.�,._�..._�,...__..._-.�_�.._....-�.....__..,___w_.M�.._.....___.�._�.._....�_._.��._._....�_..._.�._._. Page 2 of 4 FI All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics are rated UL 181A or UL 1818 Exceptions. Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). The HVAC system provides a means for balancing air and water systems. Temperature Controls: Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor is provided. Service Water Heating: Li Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: All heated swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps have a time clock. Heating and Cooling Piping Insulation: HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Spec House Page 3 of 4 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non -Circulating Runouts Circulating Mains and Runouts Heated Water Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" Temperature (°F) 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Insulation Thickness in Inches by Pipe Sizes Fluid Temp. Piping System Types Range(°F) 2" Runouts 1" and Less 1.25" to 2.0" 2.5" to 4" Heating Systems Low PressurefTemperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) Spec House Page 4 of 4 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# O 7 J /y 8 � DATE: —/Y -'O% BUILDING ADDRESS: ®tZS lick c4 I. Foundation Requirements- Minimum City Foundation Standards N A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated K II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex K 1. One -hour rated extending to roof deck 4WUOK E. Header sizes indicated on plans N K F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing plan or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements OK K A. Stairway Details K 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements OK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N K B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NAB A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) Vill. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/415) Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N K Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 NAfOK Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed OK "APPROVED PLANS PER IRC SECTION R106.3.1." __�4L__L LANS EXAMINER 5 DATE