HomeMy WebLinkAboutRES2007-01465 2208 CARLISLE CT BUILDING PERMITWF0901152 / 001 City ctf_"I lege Station
PAGE 1
REQ. DATE: 05/14/07 05/14/07 10:22:09
LOCATION: 2208 CARLISLE CT LOC ID: 199398
REQUESTOR: BENCHMARK - DBA GDT, INC ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
4" SWR TAP 3/4" WTR TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 05/14/07 SCHED COMPLETION: 05/14/07
********************************************************************************
JOB ORDER RESULT COMMENTS
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . . 8/20/07
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning
184200-0121-0310
2208 CARLISLE CT
COLLEGE STATION TX 77845
CASTLEGATE SEC 10,11,12,13
CASTLEGATE #12, BLOCK 1, LOT 3
1
PLANNED DEVL HOUSING
Owner . . . . . . . . . GREENS PRAIRIE INVESTORS LTD
Contractor . . . . . . BENCHMARK - DBA G D T INC
979 690-7117
Application number 07-00001465 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . .
Approved
Bu ding Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
PREPARED 8/20/07, 15:47:13 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/20/07
------------------------------------------------------------------------------------------------
ADDRESS . : 2208 CARLISLE CT SUBDIV: CASTLEGATE SEC 10,11,12,13
CONTRACTOR BENCHMARK - DBA G D T INC PHONE (979) 690-7117
OWNER GREENS PRAIRIE INVESTORS LTD PHONE
PARCEL 184200-0121-0310
APPL NUMBER: 07-00001465 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 5/24/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00
5/24/07 CA May 23, 2007 4:25:05 PM malford.
afternoon
Not Ready For Inspection
B100 02 5/29/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00
5/29/07 AP May 29, 2007 8:06:33 AM acarter.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 7/10/07 OC BLDG, FRAMING TIME: 17:00
7/10/07 AE July 9, 2007 3:11:58 PM kwolfe.
07/10/2007 10:17 AM OC PDA
anchors needed in master per plans.
B130 01 7/13/07 BH BLDG, INSULATION TIME: 17:00
7/13/07 AP July 13, 2007 10:03:57 AM kwolfe.
July 13, 2007 10:04:13 AM kwolfe.
B125 01 8/20/07 BI BLDG, FINAL TIME: 17:00
At CL, August 20, 2007 3:177:30 PMA ,nglsouth.
L(iLbC,1 l 1 _ A15 ` l� `ea�
----------------------------------- cola
O INUED ONTO NEXT PAGE-----------------------------------
(7/13/2007) Kim Wolfe - Insulation request inspection result,"2208 Carlisle, #07-1465 Page I
From: Brian Henry
To: Southerland, Gina
Date: 7/12/2007 4:05 PM
Subject: Insulation request inspection result, 2208 Carlisle, #07-1465
CC: Carter, Amber; Wolfe, Kim
Print for file
Inspected insulation, 2208 Carlisle, #07-1465, Benchmark Homes, 7-12-07
Inspection result: Inspected OK for Good Cents
Note:
Framing note was completed
BUILDING PERMIT ---
CITY OF COLLEGE STATION
6_-1-0'ii TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 07-00001465 Date 5/14/07
Application pin number
. . . 672370
Property Address . .
. . . . 2208 CARLISLE CT
Property ID:
184200-0121-0310
R #:
R116490
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . CASTLEGATE SEC 10,11,12,13
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . PLANNED DEVL HOUSING
Application valuation
. . . . 113916
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS
------------------------
LTD BENCHMARK - DBA G D T INC
4490 CASTLEGATE DR
1110 12TH MAN CIR
COLLEGE STATION
TX 778453388 COLLEGE STATION TX 77845
(979) 690-7117
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1726.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 441.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
KW
Permit pin number .
501999
Permit Fee . . . .
502.00 Plan Check Fee .00
Issue Date . . . .
5/14/07 Valuation . . . . 113916
Expiration Date . .
11/10/07
Qty Unit Charge
Per Extension
BASE FEE 460.00
14.00 3.0000
THOU BLDG, VAL 100001-500000 42.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
-------------------
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101' TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00001465
Application pin number . . . 672370
Page 2
Date 5/14/07
Special Notes and Comments
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 301-) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
FILL NOT ALLOWED IN SURFACE DRAINAGE EASEMENT
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
-------------------------------- --- ----- _--------
BUILDING DEPT R ZESEI�TA": ---- -
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
110f TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 07-00001465 Date 5/14/07
Application pin number . . . 672370
----------------------------------------------------------------------------
Special Notes and Comments
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
------------------------------------ --------- ---- -- ----------------------
BUILDING DEPT R ESEN AT
APPLICANT: �.JLA -or I -%--
BUILDING PERMIT
CITY OF COLLEGE STATION
+110f TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number . . . . . 07-00001465 Date
5/14/07
Application pin number . . . 672370
----------------------------------------------------------------------------
Special Notes and Comments
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Narrow Wall Bracing Fully Sheathed with APA Garage Framing
and Interior Anchors and Bracing at Front and Rear Doors.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited
------------------------------
Due
---------------------------
Permit Fee Total 502.00 502.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1252.00 1252.00 .00
.00
-------- ---- ----- ----------
BUILDING DEPT !$�VSENrTIM.
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
110f TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00001466 Date 5/14/07
Application pin number . . . 756788
Property Address . . . . . . 2208 CARLISLE CT
Property ID: 184200-0121-0310
R #: R116490
Application type description TEMP POLE
Subdivision Name . . . . . . CASTLEGATE SEC 10,11,12,13
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 0
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS LTD
------------------------
BENCHMARK - DBA G
D T INC
4490 CASTLEGATE DR
1110 12TH MAN CIR
COLLEGE STATION
TX 778453388
COLLEGE STATION
TX 77845
(979) 690-7117
----------------------------------------------------------------------------
Permit . . . . . .
TEMP POLE
PERMIT
Additional desc . .
KW
Permit pin number .
502005
Permit Fee . . . .
20.00
Issue Date . . . .
5/14/07
Valuation . .
. . 0
----------------------------------------------------------------------------
Other Fees . . . .
. . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid Credited
--------------------
Due
----------
-----------------
Permit Fee Total
----------
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
-----------------
BUILDING I
APPLICANT
�a
Few Office Use Onty
APPLICATI6N FOR BUILDING PERMIT DATE: 5 2_01 TRCC REG
1101 TEXAS AVENUE APPLICATION #
COLLEGE STATION, TX 77840 I
(979) 764-3570 (979) 764-3496 FAX TEMP POLE #
CITY OF COLLEGE STATION WINW.CSTX.GOV
.Ju _4 D ! Se '
nning eveo pmeW rvun I
ADDRESS/LOCATION: ZZD�, L° A►r��5 b� �Ve.�
LOT 31 /LOCK 'SUBDIVISION AS�1r - � SEC/PH
BUSINESS/OWNER NAME: G 1—.jwc- AA ��yy1�dK UmoPHONE: g712 d`!D -?// %
CONTRACTOR/HOMEOWNER: C(&,4JAJ--aP.444 S PHONE:'!7S-10�!Z-SI?l It
CONTRACTOR ADDRESS: 1 I 1 D 1 T JV A-V C c, Q.
ELECTRICIAN: ��� PLUMBER: S vS �t l�
u: r Q
HVAC: 0_A.'A It, V"'r- S GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION" SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK: iQle:t.J (7 ►A05 CAI
PROPOSED USE: 1 N Ckr__ 4,[A01ti : �•, _ Dry
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: _!j&,S
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION:$ — �I�:�I10 /TOTALAREA:Z?.-.—I HEATEDAREA: 1"771
(Cost of Labor and Mate Ir alt)
KPUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
11
SEWER TAP:
SIZE
WATER TAP: .514 t 1
SIZE
p OTHER TAP:
y TEMP POLE
GARAGE TYPE:
51ZE
SINGLE El
ATTACHED
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS
INTERIOR WALL TYPE
EXTERIOR WALL TYPE:
FOUNDATION TYPE
ROOF TYPE:
DOUBLE Fj4 TRIPLE
DETACHED, 71 CARPOR
3
2,
SIGNATURE OF APPLICANT: '%%�
`If proposed work involves new commercial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
-r,g 5' 11 3
F1/ Plans Examiner Zoning Official
pa
4 f 'aa�W1/T Y S r NO
Fire Marshall
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER#
0 %- lye S
DATE:
BUILDING ADDRESS: U cAk
I. Foundation Requirements- Minimum City Foundation Standards
NA/
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N O
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
N
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
tWOK
A/ K
A. Stairway Details
tff#1 OK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA�r
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N K
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NA/ K
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block an water course or divert an flow
Elevation certificate needed
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
-r� __0
L NS EXAMINER DATE
46.67'
SITE }��,�� FAR CASTLECATE SUBDI�2'
HEATED AREA: 726 so. Fr. BENCHMARK HOMES
LOT: 31 SECTION 12 PHASE GLENN THOMAS
SCALE: I' - 20' BLOCK: I ♦ SLAB AREA, 2 274 SO. FT. P$40w, FAX,
a r��<<s - ,� M-7117 ,I4 LqD-711E
REScheck Software Version 4.0.1
Compliance Certificate
Project Title: Benchmark Homes #297
Report Date: 05/09/07
Data filename: C:\Program Files\Check\REScheck\REScheck docs\297BM.rck
Energy Code: 2003 IECC
Location: College Station, Texas
Construction Type: le Family
Glazing Area Percentage: 110,v
Heating Degree Days: 8
Construction Site: Owner/Agent:
2208 Carlisle Court Glenn Thomas
Lot 31 Block 1 Castlegate Section12 Phase 2 GDT Inc. dba Benchmark Homes
College Station, , TX 77845 1110 12th Man Court
Permit Date: May 10. 2007 College Station, TX 77845
979 690 7117 or 412 5171
benchmarkhomesbcs@hotmail.com
Designer/Contractor:
Glenn Thomas
GDT Inc. dba Benchmark Homes
1110 12th Man Court
College Station„ TX 77845
979 690 7117 or 412 5171
benchmarkhomesbcs@hotmail.com
opliaoc Basses 5ooafe.—IT�8�4r-11 --- a"Coej4.�,Thnd(UA��
Maximum SHGC:
400.i
Ceiling 1: Flat Ceiling or Scissor Truss:
1726 30.0
0.0 60
Wall 1: Wood Frame, 16" o.c.:
1733 13.0
3.4 107
Window 1: Metal Frame:Double Pane with Low-E:
151
0.570 86
SHGC: 0.34
Door 1: Solid:
24
0.630 15
Door 2: Glass:
35
0.630 22
SHGC: 0.34
Floor 1: Slab -On -Grade: Unheated:
190
0.0 198
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air: 14 SEER
Furnace 1: Forced Hot Air: 80 AFUE
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in
REScheck Version 4.0.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name - Title Signature Date
Project Notes:
Job 297
2208 Carlisle Court
Lot 31 Block 1 Castlegate 12 Phase 2
College Station, Texas 77845
Benchmark Homes
1110 12th Man Court
College Station, Tx 77845
Like Home at 143 Walcourt Loop with modifications.
Benchmark Homes #297 Page 1 of 4
REScheck Software Version 4.0.1
Inspection Checklist
Date: 05/09/07
Ceilings:
❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
Above -Grade Walls:
❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity + R-3.4 continuous insulation
Comments:
Windows:
❑ Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.570
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Doors:
❑ Door 1: Solid, U-factor: 0.630
Comments:
❑ Door 2: Glass, U-factor: 0.630
Comments:
Floors:
❑ Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
❑ Air Conditioner 1: Electric Central Air: 14 SEER or higher
Make and Model Number:
❑ Furnace 1: Forced Hot Air: 80 AFUE or higher
Make and Model Number.
Solar Heat Gain Coefficient:
❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values are determined in
accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed.
❑ Recessed lights are 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" dearance from
combustible materials. If non -IC rated, fixtures are installed with a 3" clearance from insulation.
Skylights:
❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-13.
Materials Identification:
❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions.
❑ Materials and equipment are identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
Benchmark Homes #297 Page 2 of 4
Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency are clearly marked on the building plans or
specifications.
Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a
manner that achieves the rated R-value without compressing the insulation.
Duct Insulation:
Supply ducts in unconditioned attics or outside the building are insulated to R-8.
Return ducts in unconditioned attics or outside the building are insulated to R-4.
O Supply ducts in unconditioned spaces are insulated to R-6.
Return ducts in unconditioned spaces (except basements) are insulated to R-2. Insulation is not required on return ducts in
basements.
Where exterior walls are used as plenums, the wall is insulated to R-8.
Duct Construction:
Duct connections to flanges of air distribution system equipment are sealed and mechanically fastened.
All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric,
or tapes. Tapes and mastics are rated UL 181A or UL 181 B.
Exceptions:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa).
The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or
cooling input to each zone or floor is provided.
Service Water Heating:
Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat
trap or is part of a circulating system.
Circulating hot water pipes are insulated to the levels in Table 1.
Circulating Hot Water Systems:
Circulating hot water pipes are insulated to the levels in Table 1.
Swimming Pools:
All heated swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depletable
sources. Pool pumps have a time clock.
Heating and Cooling Piping Insulation:
Ej HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
Benchmark Homes #297 Page 3 of 4
•- l
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non -Circulating Runouts
Circulating Mains and
Runouts
Heated Water
Up to 1"
Up to 1.25"
1.5" to 2.0"
Over 2"
Temperature (°F)
170-180
0.5
1.0
1.5
2.0
140-169
0.5
0.5
1.0
1.5
100-139
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes
Insulation Thickness in Inches by Pipe Sizes
Fluid Temp.
Piping System Types
Range("F)
2" Runouts 1" and Less
1.25" to 2.0" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
106-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant and
40-55
0.5
0.5
0.75
1.0
Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD: (Building Department Use Only)
Benchmark Homes #297 Page 4 of 4