Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2007-01450 5310 BALLYBUNION CT BUILDING PERMIT
PREPARED 10/10/07, 7:42:=8 7\S?E17-7\ TIC{ET ?AGE 8 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/09/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 5310 BALLYBUNION CT SUBDIV: PEBBLE CREEK CONTRACTOR MARIOTT HOMES PHONE (979) 696-1787 OWNER . . PHONE : PARCEL . . 497900-0946-0600 APPL NUMBER: 07-00001450 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 5/25/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00 5/25/07 AP May 23, 2007 2:22:20 PM glsouth. FRIDAY AFTERNOON 05/25/2007 03:27 PM RH PDA Strings up, slab ground installed. B115101 7/26/07 RH BLDG, FRAMING TIME: 17:00 7/26/07 AE July 25, 2007 11:38:43 AM acarter. 07/26/2007 12:51 PM RH PDA Need to run fireplace flue through ceiling line into attic. Strap for apa at bay window needs to be installed properly. B130 01 7/27/07 RH BLDG, INSULATION TIME: 17:00 8/07/07 AP July 27, 2007 9:57:58 AM glsouth. 08/07/2007 02:36 PM RH PDA Was approved prior to this date. B125 01 10/09/ 7 Bl�_ BLDG, FINAL TIME: 17:00 0 07 — October 9, 2007 4:37:35 PM acarter. ------------------------- I --------- COMMENTS AND NOTES ---- ------------------------- ( Z,/1h.c Date: 10/10/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 1450 Address: 5310 BALLYBUNION CT Type Inspection Type Code Description status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC 05/25/2007 03:27 PM RH PDA B100 BLDG, FOUNDATION -SLAB IC Strings up, slab ground installed. 13115 BLDG, FRAMING IC 07/26/2007 12:51 PM RH PDA B115 BLDG, FRAMING IC Need to run fireplace flue through ceiling line into B115 BLDG, FRAMING IC attic. Strap for apa at bay window needs to be installed B115 BLDG, FRAMING IC properly. B130 BLDG, INSULATION IC 08/07/2007 02:36 PM RH PDA B130 BLDG, INSULATION IC Was approved prior to this date. E110 ELEC, ROUGH IN IC 07/26/2007 12:47 PM RH PDA E110 ELEC, ROUGH IN IC Need to bond GASTITE gasline as per manufacture. M100 MECH, ROUGH IN IC 07/26/2007 12:48 PM RH PDA M100 MECH, ROUGH IN IC Make sure tape on flue pipes is heat rated. P125 PLBG, FINAL IC August 27, 2007 3:19:09 PM kwolfe. P125 PLBG, FINAL IC wrong address Page 1 WF0901916 / 001 City of College Station PAGE 1 REQ. DATE: 05/14/07 05/14/07 16:28:59 LOCATION: 5310 BALLYBUNION CT LOC ID: 205894 REQUESTOR: MARIOTT HOMES, INC ORIGIN: CUSTOMER -WALK IN REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE: 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 05/14/07 SCHED COMPLETION: 05/14/07 ******************************************************************************** JOB ORDER RESULT COMY=S Service Treatment Invoice Route: < < Map Code: Start'!line: andpm Finish Time: atnlpm Type ofSersice: uili 'Regular Follow Up OncTime Charity® Service Address Name: t: eC/LrYr% Address:3/di���tJ•vr� Cite: TX 77,3yT Plione: EE ` I 1 "Shielding & Protecting Homes Against Pests" TPCLN!1486 �69F+� ' �1 Date: ~%�lr%�1`1 Appoint.Thne: J¢1 ate Frequency: N BN1 Q S Y . 1 Structure: I CriM P/B Combo `+ Pets: Dug(s) Cat(s) Bird(s) Kish Xb tiL Cost of Service "Ca Fax Total Due Payment Balance PEST PROBLEMS: it — DIRECTIONS / INSTRUCTIONS: EQUIP. IMETH. LOCATION(S) NVODESTROYING INSECTS GENERAL PESTS MICE, RODENTS, RATSAMONITORS OTHER PRODUCT QTY $jjjjjjVN2 _4786 S Payment by s Casil ❑ $ s Check ❑ # Credit Card ❑ TARGET PEST(S) leimidni SC-Flptonil.06% _ Sub(cn'ancan Termites, Ants Site orTanh____ Posted Tennldar ROW-Flprnn11.06% / SUblerranean Termites. Size ur Tank Puled Bom-care-DisodiumOctahoreteretrahsdate 50% �,_71Y?/ SublerrancanlFurmosanlDnssood-termites, Cut Ile titer Ants. Beetles, Posted CtY advance-Bait--Abaneclln.011 % C'urpentet-Ants lnsatder IIPB-Baygon 1% Demon MP-Cyano-Phenusyphen)I Uimcthycylcyclopropanccarbnt.late 1% Tempo ultra NNT-C) nuthrin.025 % (Rest) (gen. surface spray, spot, miu, cret:k S tree ice) latstar EZ Bifenthnn .2% MAxforce-t1\dramethrlon 1%-2.15% C) kick CS C Outhriu .05% 11hantom.5% Teri gard- Perin elbrin .5116 SuspuRl SC-Delttlncturin 4.751,i• (REST) \ygnard•MrlMlrtnnry 10°� (Rrtil ) Excite R Psrethrin .05% I'norac-Brnmettinlin .01% Raft Slatinn-Large/Small Glue Board+ Speckoz-Pyrocide.50% Hire[] Ill Bircudirin.06% Carpenter 1nts, Spiders, Crickets, AliIli pedes, Beetles, Termites. (.uckrnuches,:Nlill 1pedes, Smsbugs, Flies, Ticks, Musquitus, Pillbugs, Silverfish, nem, Ants, Carpenter ants, Scorpiuus, Spiders, .%tits (Escept Phuraoh). Cockroaches, Crickets, Ean+igs, Millipedes, rile,, fruit rile%, Beeves, Pilibugs,Siberfish,Spidcrs,Gnats, Horncts,Wisps,lellon Jackets. Ants, (entipedes, Cockmaches, Crickets, Grasshoppers, Scorpinns,Ttcks, Silsei fish, Spiders. Phornnh Ants, Crickets, Carpenter Ants, l.g. Roaches, %ariety of Anls, Spiders, Scotpimic. Pharob.Utts,Variet)' ofAnts, Roaches. Fleas,'I icks, %tits, Centipedes, Carpenter -Ants. Carpenter Bees, Cockroaches. CI ckers, Flies.l:arssigs, ♦lillipetles, nettles, Pillbugs. Fleas. Bees. Bcctics, Roaches, Crickels, Lice, Flies. Scurpiuns,Ticks,R'asp, IGit-GroMh licgulalor-Fleas. Roaihcs. C rickets. FI) iti; Insects, Stilted Product tests. Fleas. Mice, Rodent%, Ram dice, Rodents, Rats. Bug Monitor'. Houseflies. Mnsquitns. Moths, Fleas, %\asps, Hornets, I icks, Cockruaches. Spiden,-kuts. Roaches. Sdser fish. g,lrssigs, rlcas, Seorpioni Equipment: A C'ontpreued Sprayer PAmer Sprayer R-Rait Dispenser BS-Bait Station BT-Bait Trap D-Aerosol Can G-Cilue Huard H-Hand Dtutcr S•Spreader F-Fo,,?er Other_ --..- Locations: I -kitchen 2-1.1uh(;) .3-Bedroom; 4-Dinintr Roost 5-1-Inhis 6-giontgc 7-Cuirmiun Arcas R-Gar:mc 9-P,•nm�lcrof Strucmic 10-Aui: I 1-l:ud R-Lnd,i Homo 13-Warehotiw 14-Otfice 15 Expo,.ed Wood -' up fruit) Slab Other - _Method ol'I'rertments: CC-C rack S Cres ice SS -Sub -Slab injection AT -Void Treattncut RP-13dit Placement M-Rrnadea;t Spray PB-Perimeter Barrier BV43rick Venire WT-!Good Tteaunt nt PRECAUTIONS, Do not touclf treated arras till dry. Do not tamper Ni Mt bait stations. Ventilate rooms after trealinent. Keep pets away until pesticides ha-te dried. Licenced by the Structural Pest Control Board - 333 Guadalupe, Suite 1-530 e Austin,'!'` 78701 - 512-305-8250 SERVICETECMIC1AN: - c� �&,�' CUSTO31ERS1GNt1'1-URF: DATE: Plcasc res (en the CUStOiller Infiirlilatinit on the other aide u( inrtiice P.O. Box 9423 - College Station, TX 77842 - (979) 690-8622 - Fax (979) 690-8840 (10/12/2007) Gina Southerland - Re: Calling for CO @ 5310 Ballybunion Ct" Page 1 From: Paul Schoenfeld To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G... Date: 10/12/2007 11:15 AM Subject: Re: Calling for CO @ 5310 Ballybunion Ct ALL OK. PAUL >>> Kim Wolfe 10/11/2007 8:04 AM >>> any issues? BP # 07-1450 Thanks Kimberly Wolfe, CPS/CAP City of College Station Planning & Development Services (979) 764-3570 www.cstx.gov BUILDING PERMIT CITY OF COLLEGE STATION '`3it) T' TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . 07-00001450 Date 5/14/07 Application pin number 975450 Property Address . . . . . . 5310 BALLYBUNION CT Property ID: 497900-0946-0600 R #: R Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . PEBBLE CREEK Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 304650 Owner Contractor ------------------------ ------------------------ MARIOTT HOMES 209 ROCK PRAIRIE RD COLLEGE STATION TX 77845 (979) 696-1787 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 3.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 3385.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 419.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit pin number . 502187 Permit Fee . . . . 1075.00 Plan Check Fee .00 Issue Date . . . . 5/14/07 Valuation . . . . 304650 Expiration Date . . 11/10/07 Qty Unit Charge Per Extension BASE FEE 460.00 205.00 3.0000 THOU BLDG, VAL 100001-500000 615.00 ---------------------------------------------------------------------------- Special Notes and Comments Make Sure Minimum Finished Floor is built to 229.6 because of City Requirement of being close to Alu Creek. ----------------------------------------------- BUILDING DEPT REPRESENTATIVE: ---- -- - - -------- APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION '1101'TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 07-00001450 Date 5/14/07 Application pin number . . . 975450 ---------------------------------------------------------------------------- Special Notes and Comments Make sure Island has GFI plug. Narrow Wall Bracing Fully Sheathed with Simpson Panel at Garage and APA Framing at Front wall areas per Plans. ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of BUILDING DEPT REPRESENTATIVE: A. - A/VI - APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION '1101'TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 Page 3 Application Number . . . . . 07-00001450 Date 5/14/07 Application pin number . . . 975450 ---------------------------------------------------------------------------- Special Notes and Comments Outside A/C Unit PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES ---------------------------------------------- - - - - -- - -- - -.---------- BUILDING DEPT REPRESENTATIVE: ^A. , APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION ' 1101 ` TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 4 Application Number . . . . . 07-00001450 Date 5/14/07 Application pin number . . . 975450 ---------------------------------------------------------------------------- Special Notes and Comments THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ------------------------------ --------------------------- Permit Fee Total 1075.00 1075.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1825.00 1825.00 .00 .00 BUILDING DE APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION '1101'TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00001451 Date 5/14/07 Application pin number . . . 079571 Property Address . . . . . . 5310 BALLYBUNION CT Property ID: 497900-0946-0600 R #: R Application type description TEMP POLE Subdivision Name . . . . . . PEBBLE CREEK Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ MARIOTT HOMES 209 ROCK PRAIRIE RD COLLEGE STATION TX 77845 (979) 696-1787 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KW Permit pin number . 502195 Permit Fee . . . . 20.00 Issue Date . . . . 5/14/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due --------------------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------------- -------- - - -�-- ----- -'-------- BUILDING DEPT REPRESENTATIVE: - A - APPLICANT: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning err Development Services WWW.CSTX.GOV For Once Use Only DATE' �L TRRCC REEG� APPLICATION #\YJV TEMP POLE # l t2 ADDRESS/LOCATION: t-1 LOT S' BLOCK ►'SUBDIVISION'e��jf ,6zeh SEC/PH �� BUSINESS/OWNER NAME: RY'j�ltt &Ve6 &X, PHONE: �-"� f�'/ CONTRACTOR/HOMEOWNER: PHONE: CONTRACTOR ADDRESS: Xq�6��,�C l�� -e 11d , ELECTRICIAN: PLUMBER: L�%%% L-%/ io HVAC: GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION VING SHELL ONLY DEMOLITION (Asbestos Survey) EW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION" SWIMMING POOL Required) 11 -E,'r Ica_"Pn DESCRIPTION OF WORK: STRUCTURE USE: HOMEOWNER ASSOC IATI ON/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) ROJECT REGISTRATION# EABPRJ VALUATION: $ N 65© TOTAL AREA: HEATED AREA: (Cost of Labor and Materials) 19/PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM �SE R TAP: WATER TAP: OTHER TAP: �EMP POLE GARAGE TYPE y„ SIZE SIZE SIZE SINGLE ATTACHED Fd NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE F—] TRIPLE DETACHED F CARPORT w/ M-11'e-ml 7 6O6�1�9 Ci2r O SIGNATURE OF APPLICANT: bPI/� % /4&M *If proposed work involves new comma-rfi6re1`a cons rut ction 6� (facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only ents: L _��l'4 V 0% ES o NO IP P ans E aminer Zoning Official FYIF/owl 34 1 mIA�l4 Svice SsIF..J A*S GFt Pl"r1 wt s, Ghe,,e A" 4-NA �� Pam►+- � S S Energy Code Compliance Information � % Glazing of exterior walls (S 7 o Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) 3d Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating V PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# �S-b DATE: 0 BUILDING ADDRESS: S3 -oAi I. Foundation Requirements- Minimum Ci Foundation S ndards NWj A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated OK II. Framing: Floor, Wall, Ceiling and Roof Requirements A/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex K 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans KA/MO F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements OPOK E90K A. Stairway Details K 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NAT 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi NA/ B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements Nff A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units) T B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NNM Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed OK "APPROVED PLANS PER IRC SECTION R106.3.1." PLANS EXAMINER S"- /n __07 DATE LLY��NION S A Gou PROPERTY LINE• m