HomeMy WebLinkAboutRES2007-01424 1024 CRESTED POINT DR BUILDING PERMITPREPARED 10/25/07, 11:58:14 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/25/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 1024 CRESTED POINT DR SUBDIV: CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER . . PHONE PARCEL . . 650730-0511-0110 APPL NUMBER: 07-00001424 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP-/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 6/12/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00 6/12/07 AP June 12, 2007 10:20:21 AM acarter. Strings On Setbacks O.K. Slab Ground Installed B115 01 7/13/07 OC BLDG, FRAMING TIME: 17:00 7/13/07 AP July 13, 2007 11:05:31 AM kwolfe. July 13, 2007 4:26:48 PM kwolfe. B130 01 7/18/07 OC BLDG, INSULATION TIME: 17:00 7/18/07 AP July 18, 2007 9:55:50 AM kwolfe. July 18, 2007 4:37:43 PM kwolfe. B132 01 7/20/07 OC BLDG, SHEETROCK FASTENER TIME: 17:00 7/20/07 AP July 20, 2007 9:24:52 AM acarter. B125 01 10/17/07 RE BLDG, FINAL TIME: 17:00 10/17/07 DA October 17, 2007 8:54:55 AM acarter. 10/17/2007 02:55 PM RH PDA Need to post energy requirement data in the door of electrical panel. B125 02 10///2��ff5/g7 BLDG, FINAL TIME: 17:00 to Iv (VN OC October 25, 2007 11:54:13 AM acarter. -------------------------------------- COMMENTS AND NOTES-------------------------------------- .,)k Trr'V) -1 to r I S I',,3hde0j (QV Date. 10/25/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 1424 Address: 1024 CRESTED POINT DR Type Inspection Type Code Description Status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed B115 BLDG, FRAMING IC July 13, 2007 4:26:48 PM kwolfe. B125 BLDG, FINAL IC 10/17/2007 02:55 PM RH PDA B125 BLDG, FINAL IC Need to post energy requirement data in the door of B125 BLDG, FINAL IC electrical panel. B130 BLDG, INSULATION IC July 18, 2007 4:37:43 PM kwolfe. Ell ELEC, ROUGH IN IC 07/06/2007 10:29 AM RH PDA E110 ELEC, ROUGH IN IC Need to connect slab ground. Light fixture in bathroom Ell ELEC, ROUGH IN IC needs 3ft from tubs edge. Page 1 Amber Carter - Re: Calling for C.O. @ 1024 Crested Point Dr. 1 From: Paul Schoenfeld To: Amber Carter; Benjamin McCarty; Chris Haver; Date: 10/18/2007 11:06 am Subject: Re: Calling for C.O. @ 1024 Crested Point Dr. ALL OK. PAUL >>> Gina Southerland 10/17/2007 12:32 PM >>> BP# 07-1424 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.cstx.gov Date: 10/17/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 1424 Address: 1024 CRESTED POINT DR Insp. Inspection Type Code status Inspection Result Comments Description B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed B115 BLDG, FRAMING IC July 13, 2007 4:26:48 PM kwolfe. B130 BLDG, INSULATION IC July 18, 2007 4:37:43 PM kwolfe. E110 ELEC, ROUGH IN IC 07/06/2007 10:29 AM RH PDA E110 ELEC, ROUGH IN IC Need to connect slab ground. Light fixture in bathroom E110 ELEC, ROUGH IN IC needs 3ft from tubs edge. Page 1 WF0899941 / 001 City of College Station _ . _► PAGE 1 REQ. DATE: 05/11/07 05/11/07 8:10:51 LOCATION: 1024 CRESTED POINT DR LOC ID: 203874 REQUESTOR: STYLECRAFT BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE: 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 05/11/07 SCHED COMPLETION: 05/11/07 ******************************************************************************** JOB ORDER RESULT COMMENTS - SHEET: G-1 AREA SUMMARY P,p.ww= � cn v) w Ml 00 00,0� U C� - UQ ¢wwwHv <w� ¢W¢¢¢ H>P4F. oO<Owwo 0 N O N z� �' o Wx W �F o Q �a W M paN 1024 CRESTED POINT � HW WESTFIELD VILLAGE k w o V � u� LOT- 11 u BLOCK - 11 PHASE-5 � a o a �� wCABINET IN KITCHEN H � _ Q Q oE-NWu M 0 �wc) FN 000000�� �wwa�z w�awa'�w Q U >Q 00000000 2FRONT ELEVATION B SCALE: 3/16"=1'-0" SHEET INDEX COVER SHEET G-1 SITE PLAN C-1 FLATWORK DETAILS C-2 FOUNDATION PLAN S-1 DIMENSION PLAN S-2 FRAMING PLAN S-3 ROOF FRAMING PLAN S-4 DECKING LAYOUT S-5 FRAMING DETAILS S-6 FLOOR PLAN A-1 DETAILS A-2 ELEVATIONS A-3 CABINET LAYOUT A-4 FLOORING PLAN A-5 [ELECTRICAL PLAN E-1 VERSION # DATE REVISION 0 12/28 APPROVED MASTER 1 /1 /0 ADDED OPT�zND SINKNN M. BATH CHANGED CABINET TO FIT 2 � 1n3/os CHANGED CABINETS -MASTER BATH 3 1y1/os DELETED RB'S IN GARAGE, ADDED CJ'S 4 ��� ���� CHANGED zx6 CEILING JOISTS TO 1� YELLOW PINE FINISHING NOTES 1. 2. 3. 4. 5. 6. _ S 51026'13" W_ 50.00' 'REAR PUE +� I I I N 00 I I I I I E"° r, 12' x 10' I Y, CONC. I UI P IY I U < Q I m, �I I WI ICI w O ow I I � luc8 qu 2l I O 'co KiESD E 0 RENCE (LAM zl I 9. z I I I 17W I I I I I I I I I I I O CAR GARAGE I I I -A RON K a e=? �, w 1024 CRESTED POINT DRIVE , WESTFIELD VILLAGE LOT - 11 BLOCK - 11 5 .00' _ PHASE - 5 NC. TRUCK 51' 6'13" W WASHOUT 16 NC. HERE ° RIV BRICK RQX 1024 ISITE PLAN SCALE: 1'=20'-0" SHEET C-I AREA SUMMARY p TOOL EDGE E.J.T: 1/2" DIA. SMOOTH DOWEL 2'-0" LONG W/ PVC CAP - PLACE IN SLAB OR DRILL 9" INTO EXISTING GRADE BEAD. TAPE CAP TO LEAVE 1" O END OF ROD 4" THICK PAVING 3000 PSI REINF. W/ /3's O 18" O.C.E.W. MID DEPTH USE CHAIR SUPPORTS DISCONTINUE REINF. O E.J. IX REDWOOD DIVIDER D SECTION "D" NTS. CONTINUE REINFORCEMENT THROUGH KEYy(AY ONE CHAIR PER 4" THICK PAVING 3000 PSI 4 SO, FT. MIN. REINF. 1N/ #3's O 18" O.C.E.W. MID DEPTH USE CHAIR SUPPORTS C SECTION "C" N.T S. 3/8" DIA. DOWEL W/ SLEEVE. DRILL INTO EXISTING SIDEWALK �EXSTiNGSiDE is 1 X REDWOOD DIVIDER B SECTION "B" N.T.S. 3/8" DIA. DOWEL W/ SLEEVE. DRILL INTO EXISTING CURB 8" X 8" BEAM W/ 4 15 REBAR ASECTION "A" N.T.S. INSTALL EXPANSION JOINT, ® MID -DRIVE IF OVER 45 PROPERTY LINE 4" 0 REINFORCE W/P CBAS #3 R Q 18 O.C.E.W. VERIFY WIDTH .OF SIDE ELD CITY SIDE WALK MAIL BOX LAYDOWN CURB DETAILS SHEET C-2 AREA SUMMARY v�r�v�v�Qv� cn[0000�0 "000r•vrn�o M "1- DO ,--i 00 D BUILDIN Q LINE o CONTRACTION �OINT WHEN WI¢QwwH�i DRIVE < 16 DE w ° 4 4" THICK 3000 PSI CONC. 00¢0wo d C d REINFQRCE t/ #3 BARS E-u F-aF 18' O.C. WW 4 4 CONTRACTION JOINT ° O 4 d N INSTALL METAL KEY%kAY O = EXP. JOINT W/ 3/§ DIA. LICK DW LS. @ 18 O.C. U ° d W/ SLEEVES ONE SIDE .. Z a °4 Q x F 0 M W �w 0 B w0 O d x � a� 3 d Fi IA d ° 4 ° d o (V BUILDING PERMIT CITY OF COLLEGE STATION 11101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00001424 Date 5/10/07 Application pin number . . . 618768 Property Address . . . . . . 1024 CRESTED POINT DR Property ID: 005401-0511-0110 R #• Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 89958 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE MASONRY IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1363.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit pin number . 501833 Permit Fee . . . . 420.00 Plan Check Fee .00 Issue Date . . . . 5/10/07 Valuation . . . . 89958 Expiration Date . . 11/06/07 Qty Unit Charge Per Extension BASE FEE 260.00 40.00 4.0000 THOU BLDG, VAL 50001-100000 160.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLE S IN DWELLING UNIT BEDROOMS SHALL --------------------------------------- BE PROTECTED AN ARC FAULT CIRCUIT -- -- - --------------- BUILDING DEPT REPRESENTA''�E: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1161 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00001424 Application pin number . . . 618768 Page 2 Date 5/10/07 Special Notes and Comments INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. ------------------------------------------- ----�------------- BUILDING DEPT REPRESENTAT;I-V-k: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 07-00001424 Date 5/10/07 Application pin number . . . 618768 ---------------------------------------------------------------------------- Special Notes and Comments REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE ------------------------------------------ -� ----- A---A---=-s ------------- BUILDING DEPT REPRESENTA APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 4 Application Number . . . . . 07-00001424 Date 5/10/07 Application pin number . . . 618768 ---------------------------------------------------------------------------- Special Notes and Comments TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ------------------------------ --------------------------- Permit Fee Total 420.00 420.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1170.00 1170.00 .00 .00 ------------------------------------- - - - - -- ---------- - - - - -- BUILDING DEPT REPRESENTATZ\ APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00001425 Date 5/10/07 Application pin number . . . 751225 Property Address . . . . . . 1024 CRESTED POINT DR Property ID: 005401-0511-0110 R #. Application type description TEMP POLE Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KW Permit pin number . 501841 Permit Fee . . . . 20.00 Issue Date . . . . 5/10/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 BUILDING DEPT REPRESENT G e I1 APPLICANT: APPLICATION FOR BUILDING PERMIT (*. CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Plcnrsin� G�DcrcGpr `-nt Srrnica wWW.CSTX.GOV DATE TRCCIREG APPLICATION m TEMP POLE # ADDRESS/LOCATION: /oVi C2ESTE>7 /- e7y yi ✓ LOT11 '-BLOCK II SUBDIVISION W65T-F/E1-D \/ILLA�2ZE --SEC/PH S --- BUSINESS/OWNER NAME: STYLECRAFT BUILDERS INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS INC. PHONE: 690-1222 ext. 120 CONTRACTOR ADDRESS:_ 4090 State Highway 6 South ELECTRICIAN: _ Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temo GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) H NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: Conventional Framinq STRUCTURE USE: _ Single Family Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $_ 014 q56 TOTAL AREA: 1W HEATED AREA: 136-5 (Cost of Labor and Materials) 'p QX PUBLIC SEWER �u "J SEPTIC/TREATMENTSYSTEM SEWER TAP: nXX WATER TAP: ,_S THER TAP: X TgIP POLE �J GARAGE TYPE: SIZE %° SIZE SIZE SINGLE ATTACHED f NUMBER OF BEDROOMS: 5 NUMBER OF BATHROOMS: Z INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: Siding and/or Masonry FOUNDATION TYPE: Slab on Grade ROOF TYPE: Composition DOUBLE © TRIPLE a CARPORT SIGNATURE OF APPLICANT. c 5 LIo7 For Stylecr *If proposed work involves new commercial construc I or faca a improvements/renovations to an existing commercial property building elevations are required. 0000000ee00000ee000eeooe00000e000000aoe0000000a000a0000000ao Official Use Only ­7 b V-0 7 Co ems. S r NO Plns ExaminerN ,�Official �aG /hyion Ac•ei"5 Energy Coyle Compliance Information % Glazing of exterior walls Insulation R value of exterior vralls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A./C SEER Rating 1 0/O ✓ R13 / R30 R19 .40 .65 R6 13 - PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# DATE: _ �va BUILDING ADDRESS: 0 1 Y C-ad Po I. Foundation Requirements- Minimum City Foundation Standards NA/ A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated O KA II. Framing: Floor, Wall, Ceiling and Roof Requirements NNOW A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex K 1. One -hour rated extending to roof deck WJUOK>l E. Header sizes indicated on plans NAIgV F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roofcovering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements OK POK A. Stairway Details MNOK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi AlgIV B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NLUktj A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units) T B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements NAICK A. Compliance software worksheet MECcheck submitted, or AV B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NAJ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NA/ Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 NkPO Does not block any water course or divert any flow Elevation certificate needed K "APPROVED PLANS PER IRC SECTION R106.3.1." �-�7 PLANS EXAMINER DATE REScheck Software Version 3.7.3 Compliance Certificate Project Title: Plan # 1363-WV Report Date: 05/04/07 Data filename: S:\HCAD\Archived\Old REScheck\1363_1024 CRESTED.cck Energy Code: Location: Construction Type: Glazing Area Percentage: Heating Degree Days: Construction Site: Permit Date: 05-04-2007 2003 IECC College Station, Texas Single Family 11% 1788 Owner/Agent: Designer/Contractor: Permit # Permit Date ;Compliance: Passes MaxiffiGnTOA: 5341Your Home UA-448=,1671%,Bettei'iThan'Code'(UA). Maximum SHGC: -i -0 Ceiling 1: Flat Ceiling or Scissor Truss: Ceiling 2: Cathedral Ceiling (no attic): Wall 1: Wood Frame, 16" o.c.: Window 1: Metal Frame, Double Pane with Low-E: SHGC: 0.40 Door 1: Solid: Door 2: Glass: SHGC: 0.40 Floor 1: Slab -On -Grade: Unheated: , Insulation Depth: 0.0' Air Conditioner 2• Electric Central Air: 13 SEER Furnace 2: Forced Hot Air: 80 AFUE 1139 30.0 0.0 40 224 19.0 0.0 12 1399 13.0 0.0 99 132 0.670 88 38 0.500 19 18 0.440 8 175 0.0 182 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.7.3 and to comply with the mandat ry requirements listed in the REScheck Inspection Checklist. 51 Y4,569A-F 5 407 Builder/Designer Company Name Date Project Notes: Previously saved project information: SPEC 1024 CRESTED POINT COLLEGE STATION, Texas Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 Plan # 1363-WV Page 1 of 1