Loading...
HomeMy WebLinkAboutRES2007-01420 912 CRESTED POINT DR BUILDING PERMIT(11 /28/2007) Gina Southerland - Re: Calling for C.O. @ 912 Crested Point Dr w Page 1 From: Mitchell Carson To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G... Date: 11/28/2007 11:30 AM Subject: Re: Calling for C.O. @ 912 Crested Point Dr This one is OK Mitch >>> Gina Southerland 11/28/07 8:10 AM >>> BP# 07-1420 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.cstx.4ov PREPARED 11/28/07, 7:58:13 INSPECTION TICKET PAGE 2 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 11/27/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 912 CRESTED POINT DR SUBDIV: WESTFIELD VILLAGE PH 4 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER . . PHONE PARCEL . . 650730-0411-0140 APPL NUMBER: 07-00001420 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT z REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B1GD O1 6/19/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00 6/19/07 AP June 19, 2007 8:24:02 AM glsouth. Strings On Setbacks O.K. Slab Ground Installed B115 01 7/12/07 OC BLDG, FRAMING TIME: 17:00 7/12/07 AP July 11, 2007 1:14:34 PM kwolfe. B130 01 7/13/07 OC BLDG, INSULATION TIME: 17:00 7/13/07 AP July 12, 2007 3:47:58 PM acarter. afternoon July 13, 2007 4:26:05 PM kwolfe. B132 01 7/16/07 JGM BLDG, SHEETROCK FASTENER TIME: 17:00 7/16/07 AP July 16, 2007 8:51:10 AM GLSOUTH. B125 01 11 7�07 AO Q� BLDG, FINAL TIME: 17:00 November 27, 2007 4:26:43 PM kwolfe. ----------------------------------- CONTINUED ONTO NEXT PAGE------------- ---------------------- '�pj0 b� Date 11/28/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 1420 Address: 912 CRESTED POINT DR Type Inspection Type Code status Inspection Result Comments Description B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed B130 BLDG, INSULATION IC July 13, 2007 4:26:05 PM kwolfe. E150 ELEC, FINAL IC 08/24/2007 02:52 PM RH PDA E150 ELEC, FINAL IC Need to raise grade of yard by Building final. Page 1 WF0899933 / 001 City of College Station PAGE 1 REQ. DATE: 05/11/07 05/11/07 8:06:20 LOCATION: 912 CRESTED POINT DR LOC ID: 203828 REQUESTOR: STYLECRAFT BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE: 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 05/11/07 SCHED COMPLETION: 05/11/07 ******************************************************************************** JOB ORDER RESULT COMMENTS - SHEET G-I AREA SUMMARY wwa.w= N� w O� �C`�000000 O� O 00 (V 00 ¢www�v� ax�.awa oo�owwo N o � z� a o U QF a � z �o Q 912 CRESTED POINT W WESTFIELD VILLAGE wo W " LOT - 14 w o P ASE-4 H W ®® m a ------------------------------------- ¢ Q �QzQ EEO: IlTm onwu ¢�Qwz "-' C) P4osoon 11 win Q U) aQ MEN 70 3FRONT ELEVATION C SCALE: 3/16'=V-0' SHEET INDEX COVER SHEET G-1 SITE PLAN C-1 FLATWORK DETAILS C-2 FOUNDATION PLAN S-1 DIMENSION PLAN S-2 FRAMING PLAN S-3 ROOF FRAMING PLAN S-4 DECKING LAYOUT S-5 FRAMING DETAILS S-6 FLOOR PLAN A-1 DETAILS A-2 ELEVATIONS A-3 VERSION # DATE REVISION 0 11 /01 APPROVED MASTER 1 /1 /0 ADDED OPTIONAL 6 X 9 COVERED PORCH REMOVED CABINET OVER REFRIGERATOR 2 1 /10/07 CHANGED 2X6 CEILING JOISTS TO 1R3 YELLOW PINE FINISHING NOTES 1. 2. 3. 4. 5. 6. r �w� la I I I I I I ' I FENCE W/ GATE i m SHEET C-1 AREA UMMARY UE ' PC _ d NC. TRUCK WASHOUT 1 n _j HERE RIVE 17 x-1() CONC. PATIO I N ' FENCE O I ;wow I Lo I Z � I I I I ^ a I I I ^ {� I I I I I - - - I N — KI N' 1912 CRESTED POINT DRIVE Q-I �w WESTFIELD VILLAGE U 'LOT -14 w BLOCK -11 15_56 PHASE - 4 1 SITE PLAN SCALE: 1 "=20'-0" (11/29/2007) Gina Southerland -Re: Callin�gfor C.O. 0.912 Crested Point Dr - _ ---------Page 1 From: Mitchell Carson To: Gina Southerland Date: 11/28/2007 11:28 AM Subject: Re: Calling for C.O. @ 912 Crested Point Dr This one is OK Mitch >>> Gina Southerland 11/28/07 8:10 AM >>> BP# 07-1420 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.cstx.Qov BUILDING PERMIT CITY OF COLLEGE STATION i_ 101 i EXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00001420 Date 5/10/07 Application pin number . . . 088940 Property Address . . . . . . 912 CRESTED POINT DR Property ID: 005401-0411-0140 R #• Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD VILLAGE PH 4 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 75834 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE MASONRY IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1149.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit BUILDING PERMIT Additional desc KW Permit pin number 501791 Permit Fee . . . . 364.00 Plan Check Fee .00 Issue Date . . . . 5/10/07 Valuation . . . . 75834 Expiration Date . . 11/06/07 Qty Unit Charge Per Extension BASE FEE 260.00 26.00 4.0000 THOU BLDG, VAL 50001-100000 104.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY CIRCUIT --------------------------------------- BUILDING DEPT REPRESENT -----LARC-FAULT 1-1191� ----------- APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION �101 i EXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00001420 Application pin number . . . 088940 Page 2 Date 5/10/07 Special Notes and Comments INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SP CIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH ASURED AT T E - _ ---------------------------------------- -- -�- ------ ------------ BUILDING DEPT REPRESENTATIaVF:, APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00001420 Application pin number . . . 088940 Page 3 Date 5/10/07 Special Notes and Comments PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING OOM AND OUTSIDE EACH -------------------------------------------- -----�----------- BUILDING DEPT REPRESEN;T.A1f�VFF.,, APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 Page 4 Application Number . . . . . 07-00001420 Date 5/10/07 Application pin number . . . 088940 ---------------------------------------------------------------------------- Special Notes and Comments SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged ---------- Paid ---------- Credited -------------------- Due Permit Fee Total 364.00 364.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1114.00 1114.00 .00 .00 --------------------------------------------''j------A---.s--=- f-=---------- BUILDING DEPT REPRES APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1 101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00001421 Date 5/10/07 Application pin number . . . 221397 Property Address . . . . . . 912 CRESTED POINT DR Property ID: 005401-0411-0140 R #. Application type description TEMP POLE Subdivision Name . . . . . . WESTFIELD VILLAGE PH 4 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit TEMP POLE PERMIT Additional desc KW Permit pin number 501809 Permit Fee . . . . 20.00 Issue Date . . . . 5/10/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 J64A6 /J. Awp"A�� BUILDING DEPT REPRESENTAT-I3VE.;.� APPLICANT: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX T7840 Crn OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planing �Dcrelapnz�t Saviru WWW.CSTX.GOV Fx O.£= Uw OnP/ DATE: t/ T RCC REG APPLJCATION mCl— 149 TEMP POLE ADDRESS/LOCATION: 017 C rr ;, D )'�:olN r JtVZ/ LOT _,_�L_/BLOCK i I / SUBDMSION I,/�STT7�L,7 V iLL AG�I= + SEC/PH _9__� BUS INESSIOWNER NAME: STYLECRAFT BUILDERS INC PHONE: 690-1222 ext.120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS INC. PHONE: 690-1222 ext. 120 CONTRACTOR ADDRESS: _ 4090 State Highway 6 South ELECTRICIAN: —Brazos; Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS IResidentlal only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) H NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: Conventional Framinq STRUCTURE USE: Single Family Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ NIA VALUATION: $_ 75 834 TOTAL AREA: 15f)8 HEATED AREA: 1149 (Cost of Labor and Materials) oFx_ PUBLIC SEWER 3 U SEPTIC/TREATMENT SYSTEM 15 q SEWER TAP: 4" SIZE nX WATER TAP: %" SIZE OTHER TAP: EMP POLE 1 /''GARAGE TYPE: SIZE SINGLE 0 ATTACHED NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE ROOF TYPE: DOUBLE KI ET, CHED 2 Sheet Rock Siding and/or Masonry Slab on Grade Composition TRIPLE ED CARPORT 0 SIGNATURE OF APPLICANT: (_ //1 / ) _>_O� *If proposed work involves new commercial construc or acade t commercial property, building elevations are required. oe000eoee000000eoeooe.00000000e0000 0 Offrcial Use Only R .5"-y,-o-1 Plans Examiner 474A-w wl N — 9-4y,;►SOX/ Zoning Official to an existing 0000e0000000000000ao ments: E or NO jnerrgy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior,,jralls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating / Ll 0/0 '/ R13 i R30 R19 .40 .65 R6 / 13., 4 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# N Zo DATE: Jr ` O BUILDING ADDRESS: Z S Ai I. Foundation Requirements- Minimum City Foundation Standards NA/ A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated hkOK II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans A/ F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements 4WOK UOK A. Stairway Details N OK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1.. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements OK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi NAB B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N O A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) Vill. Energy Requirements NAAW A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NAfM Permitted use for district 17- Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NA/ Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 NA/ Does not block any water course or divert any flow Elevation certificate needed K "APPROVED PLANS PER IRC SECTION R106.3.1." AV,.'t - - PLANS EXAMINER s(�- E)7 DATE REScheck Software Version 3.7.3 Compliance Certificate Project Title: Plan # 1149C-WV Report Date: 05/04/07 Data filename: S:WCADWrchived\Old REScheck\1149C_912 CRESTED POINT rck Energy Code: 2003 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 14% Heating Degree Days: 1788 Construction Site: Permit Date: 05-04-2007 Owner/Agent: Designer/Contractor: Permit # Permit Date CompIiOc Passe's Maximum UA:_489MYourLHom UA!440 - ,10.0%113etteiiThan Code (UA)] Maximum SHGC: -i 0.40 Ceiling 1: Flat Ceiling or Scissor Truss: Ceiling 2: Cathedral Ceiling (no attic): Wall 1: Wood Frame, 16" o.c.: Window 1: Metal Frame, Double Pane with Low-E: SHGC: 0.40 Door 1: Solid: Door 2: Glass: SHGC: 0.40 Floor 1: Slab -On -Grade: Unheated: , Insulation Depth: 0.0' Air Conditioner 2: Electric Central Air: 13 SEER Furnace 2: Forced Hot Air: 80 AFUE 845 30.0 0.0 30 294 19.0 0.0 15 1186 13.0 0.0 81 132 0.650 86 38 0.500 19 33 0.580 19 182 00 190 Compliance Statement. The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.7.3 and to comply with the mand requirements listed in the REScheck Inspection Checklist. STYG�c2 a 5A47 Builder/Designer Company ame Date Project Notes: Previously saved project information: SPEC 912 CRESTED POINT College Station, Texas Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 Plan # 1149C-WV Page 1 of 1