Loading...
HomeMy WebLinkAboutRES2007-01394 1511 BLUEFIELD CT BUILDING PERMITPREPARED 12/03/07, 12:04:17 INSPECTION TICKET PAGE 2 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 12/03/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 1511 BLUEFIELD CT SUBDIV: SHENANDOAH PH 19 CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER ED FROEHLING BUILDER INC PHONE PARCEL 569500-1947-0050 APPL NUMBER: 07-00001394 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 6/08/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00 6/08/07 AP June 8, 2007 9:09:00 AM kwolfe. B120 01 7/03/07 OC 7/03/07 AP B115 01 7/31/07 RH 7/31/07 AE B130 01 8/28/07 OC AP B125 01 1 /03/0 BI BLDG, FRAMING -PARTIAL TIME: 17:00 July 3, 2007 8:18:58 AM acarter. INSPECT GARAGE AREA FOR APA BRACING BLDG, FRAMING TIME: 17:00 July 30, 2007 5:02:11 PM glsouth. TUES. AFTERNOON 07/31/2007 04:23 PM RH PDA Add fireblocking at fireplace and install all windows by insulation inspection. BLDG, INSULATION TIME: 17:00 August 28, 2007 3:22:14 PM ACARTER. BLDG, FINAL TIME: 17:00 December 3, 2007 9:04:38 AM glsouth. -------------------------------------- COMMENTS AND NOTES -------------------------------------- Cpri NeJ pjj(l&�5,S per- I-,,✓ E4 AFco( fw,,-el V� O Date 12/3/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 1394 Address: 1511 BLUEFIELD CT Type Inspection Type Code Status Inspection Result Comments Description 13115 BLDG, FRAMING IC 07/31/2007 04:23 PM RH PDA B115 BLDG, FRAMING IC Add fireblocking at fireplace and install all windows by B115 BLDG, FRAMING IC insulation inspection. M100 MECH, ROUGH IN IC 07/27/2007 01:12 PM JGM PDA M100 MECH, ROUGH IN IC need to form 90 degrees at register boxes P105 PLBG, TOP OUT IC 07/24/2007 03:04 PM JGM PDA P105 PLBG, TOP OUT IC need nailguards on gastite by the fireplace Page 1 WF0906108 / 001 City of College Station PAGE 1 REQ. DATE: 05/22/07 ' 05/22/07 8:17:22 LOCATION: 1511 BLUEFIELD CT LOC ID: 204856 REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE: SWR 4" WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 05/22/07 SCHED COMPLETION: 05/22/07 ******************************************************************************** JOB ORDER RESULT COMMENTS (12/4/2007) Gina Southerland - Re: Calling for CO for 1511 Bluefield Ct Page 1 From: Terry Boriskie To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G... Date: 12/4/2007 9:05 AM Subject: Re: Calling for CO for 1511 Bluefield Ct Contacted Ed Froehling Homes at 776-8266 and told them of needed repairs. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Mitchell Carson 12/3/2007 3:43 pm >>> Box on sewer clean out is broke needs to be replaced. Mitch >>> Amber Carter 12/03/07 12:18 PM >>> by 07-1394 any issues? BUILDING PERMIT CITY OF COLLEQE'ST�,TION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00001394 Date 5/21/07 Application pin number . . . 655704 Property Address . . . . . . 1511 BLUEFIELD CT Property ID: 569500-1947-0050 R #: R304106 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SHENANDOAH PH 19 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 143880 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDER INC ED FROEHLING BUILDERS 3887 HIGH LONESOME 3887 HIGH LONESOME RD COLLEGE STATION TX 778459443 COLLEGE STATION TX 77845 (979) 776-8266 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID YES FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2181.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 5.00 SEWER TYPE PUBLIC TAZ 427.00 ---------------------------------------------------------------------------- Permit BUILDING PERMIT Additional desc GS Permit pin number 503524 Permit Fee . . . . 592.00 Plan Check Fee .00 Issue Date . . . . 5/21/07 Valuation . . . . 143880 Expiration Date . . 11/17/07 Qty Unit Charge Per Extension BASE FEE 460.00 44.00 3.0000 THOU BLDG, VAL 100001-500000 132.00 ---------------------------------------------------------------------------- Special Notes and Comments Kitchen Island Needs GFI Plug ------------------------------------------ -�- -&WOZ� --------------- BUILDING DEPT REPRESENTATIVE; APPLICANT: BUILDING PERMIT CITY OF COLLEGE ST:-r-,TION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00001394 Application pin number . . . 655704 Page 2 Date 5/21/07 Special Notes and Comments Narrow Wall Bracing Fully Sheathed with APA Garage Framing ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 30") WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT OR A ZSS Y nAV TO BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE ST.7,),TION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 07-00001394 Date 5/21/07 Application pin number . . . 655704 ---------------------------------------------------------------------------- Special Notes and Comments BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ------------------------------------------------- -A ----- - !! ------------- BUILDING DE PT /�/V�EE: APPLICANT: �jPRESENTAT Q/y�I.�/// //�/ , A-i BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 4 Application Number . . . . . 07-00001394 Date 5/21/07 Application pin number . . . 655704 ---------------------------------------------------------------------------- Special Notes and Comments ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged ---------- Paid ---------- Credited -------------------- Due Permit Fee Total 592.00 592.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1342.00 1342.00 .00 .00 - APPLICANT: CITY OF COLLEGE STATION d DevelopmentSeevieei A �7�C► LOCATION: APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CSTX.GOV LO BLOCK `t 7 BL/OWNER NAME: rFa 011l eUb�ly DATE- ` � l T REG APPLICATION # TEMP POLE # V SUBDIVISION (��(11y11jCLlG LL// SEC/PH_a_::-- PHONE: EOWNER: &61 W&"4 PHONE: 7760 -b�-7&Q ADDRESS: 77, ELRIrAN: PLUMBER: �— HV,t GOOD CENTS (Residential only): 0CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) I,, NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans) REMODEURENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: 0 (CIO\ PROPOSED USE: 1 HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN R VIEW COMMITTEE APPROVAL: ��I -D `q TEXAS ACCESSIBILITY STANDARD (TAS) P OJECT REGISTRATION# EABPRJ -`. VALUATION: $ �3, ��� 0U 7 TOTAL AREA: l7 HEATED AREA: (Cost of Labor and Materials) EJ/PUBLIC SEWER SEPTIC/TREATMENT SYSTEM ©SEWER TAP: 4 /' 22 SIZE JJ WATER TAP: 11 u SIZE OTHER TAP: WEQV�+���r.SIZE MP POLE t . f a NUMBER OF BEDROOMS: NUMBER OF BATHROOMS INTERIOR WALL TYPE: EXTERIOR WALL TYPE FOUNDATION TYPE:_ 1" or ROOF TYPE: U 51C k GARAGE TYPE: SINGLE F__1 DOUBLE a TRIPLE ATTACHED F_�71/ DETACHED a CARPORT SIGNATURE OF APPLICANT: *If proposed work involves new commercial constructiQh or facade commercial property, building elevations are required. ` Official Use Only Plans Examiner improvements/renovations to an existing Zoning Official N C ents: NO Fire Marshall �Ic s PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# D,7 _ 13 7 DATE: s_ y-0 -7 BUILDING ADDRESS: I Eltje4(�eflj I. Foundation Requirements- Minimum City Foundation Standards N A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated OK II. Framing: Floor, Wall, Ceiling and Roof Requirements NAIQV A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans WAM F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clearmidth_b _twent -four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements MMOK OOK A. Stairway Details OK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor _ 6. _Guards-&-handrails-along-open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening ? 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements- V. Electrical Service Requirements A. Electrical plan to include: N 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N K Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NAM Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed OK "APPROVED PLANS PER IRC SECTION R106.3.1." ,L- 1,� P ANS EXAMINER _5-61-o'7 DATE Permit Number REScheck Compliance Certificate Checked By/Date 2000 IECC REScheckSoftware Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\1501BF.rck TITLE: 1511 BLUEFIELD CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 05/02/07 DATE OF PLANS: SEPT 4, 2004 PROJECT INFORMATION: SPEC COMPANY INFORMATION: ED FROEHLING BUILDER, INC NOTES: NARROW 5-BED WITH ALLEY GARAGE COMPLIANCE: Passes Maximum UA = 715 Your Home UA = 552 22.8% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.36 Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 2181 30.0 0.0 76 Wall l: Wood Frame, 16" o.c. 471 15.0 0.0 28 Window 1: Metal Frame:Double Pane with Low-E 93 0.600 56 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Front Projection factor: 0.23 Door 1: Solid 20 0.400 8 Wall 2: Wood Frame, 16" o.c. 415 15.0 0.0 30 Window 2: Metal Frame:Double Pane with Low-E 31 0.600 19 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Left Side Projection factor: 0.27 Wall 3: Wood Frame, 16" o.c. 367 15.0 0.0 24 Window 3: Metal Frame:Double Pane with Low-E 40 0.600 24 SHGC: 0.40 s Bldg. faces 135 deg. from North; Comp. orient.: Back Projection factor: 0.27 Door 2: Glass 18 0.580 10 SHGC: 0.78 Bldg. faces 135 deg. from North; Comp. orient.: Back Projection factor: 1.02 Wall 4: Wood Frame, 16" o.c. 425 15.0 0.0 29 Window 4: Metal Frame:Double Pane with Low-E 43 0.600 26 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Right Side Projection factor: 0.27 Floor 1: Slab-On-Grade:Unheated 213 0.0 222 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 13 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in RES checkVersion 3.5 Release lb (formerly MECchec� and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Builder/Designerl�'y�� `� C� Date 5 I h! �G, [; �C4iarF tll;rrn: E?F! J 1', J ��G'LUIPI��F�iR�7'I�f7YEENGINEE/0M��URI�t77NG, /�VG'• IR�fS�F�arfc�a�I'lXir� Sa1M>D3•Ca�/�p�v.Sl��i, %rasTlB/3•%�11,��ffft3�� Lot 05 01.,Ck 47.dwg IIj r Lot 5 1 Lot 4 Now er Formerly Now or Formuly Mohamed t t:lano Hajj-'Ji Sntw 11 Chrletlno McGaral Vol, 2771, Pg. 129 _ _ _ r !' Vol. ^6799. Pg. 129 Reed40i+i��o^ s � stenand 7. Pg gO 20 Pub/ie A11e1' vet + N 45,v2'18 -- moo, LV n _ �7 r Note: -D000 irwj so ack Ur-m per C1ty of L`oNege S tlon Unified C DevK1G mot Ord! nce 12617 ' Scale' 1" 20' I 1511 B/uefilv/d Cpwf � drot 5, Block 47 W Now c OtFormerly I SbefMdoah Phase 19 r, I N„w a °tF rmcrly EC F�oerling Ou;lder, Inc. 10 reoehl'o�nqq pwlder, inc Vol. 7343. Pg. t 01 VOL 7.'.43, Pg. t 4, pn Proposed Residence I 7.7, 49 5' 7.e' 4 m ,S 45V211B4r w — 65. 00 Back/CLrb Bluefield Coult 50' R.0.W. M 27' Pammenf Vol. 7J4J, Pr 101