HomeMy WebLinkAboutRES2007-01393 4405 HEARST CT BUILDING PERMITPREPARED 12/12/07, 7:56:09 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 12/12/07
------------------------------------------------------ :
. : 4405 HEARST CT SUBDIV: CASTLEGATE PH 5 SEC 2
CONTRACTOR ED FROEHLING BUILDERS PHONE : (979) 776-8266
OWNER GREENS PRAIRIE INVESTORS LTD PHONE
PARCEL 184200-2503-0520
APPL NUMBER: 07-00001393 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 6/21/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00
6/21/07 AP June 21, 2007 10:22:08 AM acarter.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 9/13/07 OC BLDG, FRAMING TIME: 17:00
9/13/07 AP September 12, 2007 11:58:04 AM glsouth.
B130 01 9/20/07 RH BLDG, INSULATION TIME: 17:00
9/20/07 AP September 20, 2007 9:09:53 AM acarter.
B135 01 11/26/07 OC BLDG, CEILING COVER UP TIME: 17:00
11/26/07 CA November 21, 2007 1:11:04 PM acarter.
asked for a lay in ceiling cover inspection
November 26, 2007 10:19:51 AM acarter.
inspection entered at the wrong address
B125 01 12/06/07 RH BLDG, FINAL TIME: 17:00
12/06/07 DP December 6, 2007 12:08:34 PM glsouth.
12/06/2007 04:04 PM RH PDA
Need address on both sides of mailbox or one on the house.
Need to install hardware. Post energy requirements
certificate on electrical panel.
B125 02 12/12/07 BR t�
BLDG, FINAL TIME: 17:00
December 12, 2007 7:54:01 AM kwolfe.
-------------------------------------- COMMENTS AND NOTES --------------------- --- ��4
N
bo-K srel,e8 w�
Date: 12/12/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1393
Address: 4405 HEARST CT
Insp.
Inspection Type Code
Description
Status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B125
BLDG, FINAL
IC
12/06/2007 04:04 PM RH PDA
B125
BLDG, FINAL
IC
Need address on both sides of mailbox or one on the
B125
BLDG, FINAL
IC
Need to install hardware. Post energy requirements
B125
BLDG, FINAL
IC
certificate on electrical panel.
B135
BLDG, CEILING COVER UP
IC
November 26, 2007 10:19:51 AM acarter.
B135
BLDG, CEILING COVER UP
IC
inspection entered at the wrong address
Page 1
Date. 12I6I2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1393
Address: 4405 HEARST CT
Insp.
Inspection Type Code
p.
status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B135
BLDG, CEILING COVER UP
IC
November 26, 2007 10:19:51 AM acarter.
B135
BLDG, CEILING COVER UP
IC
inspection entered at the wrong address
Page 1
WF0906236 / 001 City of Colletge Station
PAGE 1
REQ. DATE: 05/22/07 05/22/07 9:23:25
LOCATION: 4405 HEARST CT LOC ID: 204070
REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR' 3/4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 05/22/07 SCHED COMPLETION: 05/22/07
********************************************************************************
JOB ORDER RESULT COMMENTS
(12/18/2007) Gina Southerland - Re: Calling for CO for 4405 Hearst Ct ' Page 1
From: Terry Boriskie
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 12/6/2007 3:47 PM
Subject: Re: Calling for CO for 4405 Hearst Ct
Contacted Pam at Ed Froehling at 776-8266
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Mitchell Carson 12/6/2007 3:43 pm >>>
Need to replace sewer box and lid, it is missing Mitch
>>> Amber Carter 12/06/07 12:15 PM >>>
by 07-1393
Any issues?
BUILDING PERMIT
CITY OF COLLEGE 'STA-a'?DN
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00001393
Date 5/21/07
Application pin number . . . 504588
Property Address . . . . . . 4405 HEARST CT
Property ID: 184200-2503-0520
R #: R303684
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . CASTLEGATE PH 5 SEC 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 154440
Owner Contractor
------------------------ ------------------------
GREENS PRAIRIE INVESTORS LTD ED FROEHLING BUILDERS
4490 CASTLEGATE DR 3887 HIGH LONESOME RD
COLLEGE STATION TX 778453388 COLLEGE STATION
TX 77845
(979) 776-8266
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2340.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
5.00
SEWER TYPE
PUBLIC
TAZ
441.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . GS
Permit pin number . 503482
Permit Fee . . . . 625.00 Plan Check Fee
.00
Issue Date . . . . 5/21/07 Valuation . .
. . 154440
Expiration Date . . 11/17/07
Qty Unit Charge Per
Extension
BASE FEE
460.00
55.00 3.0000 THOU BLDG, VAL 100001-500000
165.00
----------------------------------------------------------------------------
Special Notes and Comments
Narrow Wall Bracing Fully Sheathed with APA 18" Minimums
Garage Framing.
------------------------------------ -------- ----- X--
BUILDING DEPTRREPRESENTATIVE:
----------
APPLICANT: A I nI/%, IY) 441111A
BUILDING PERMIT
CITY OF COLLEGE'STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00001393
Application pin number . . . 504588
Page 2
Date 5/21/07
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR
ATTACHED GARAGES SHALL HAVE
PENETRATIONS SEALED
Assure Proper GFI Locations,
Outside A/C Unit
GARAGE DOOR HEADER
ALL TOP PLATE AND HEADER
Including One Within 25' Of
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULAT ON
----------------------------- ----`--- --.- -'---------
BUILDING DEPT REPRESENTATIVE:
r .AA I l _ An
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE 'STATI'ON
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00001393 Date 5/21/07
Application pin number . . . 504588
----------------------------------------------------------------------------
Special Notes and Comments
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT 0 ALL GLAZED
------------------------------------------------ -....
-------
BUILDING DEPT^REPRESENTATIVY:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE 'STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number . . . . . 07-00001393 Date
5/21/07
Application pin number . . . 504588
----------------------------------------------------------------------------
Special Notes and Comments
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------------------------------
-----------------
Permit Fee Total 625.00 625.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1375.00 1375.00 .00
.00
--------------------------------------- - -
- --- ------ ----------
BUILDING DEPT REPRESENTATIVE:
AA )9 _ ///
APPLICANT:
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION WWW.CSTX.GOV
P!a .4 D ! r S '
For O e6Use�Only
DATE: 515 7RCC REG
APPLICATION #
TEMP POLE #
nning rvr oprnen Se es ADDRESS/LOCATION: 4$O Jc
�4EAyJr Coug r "
LOT SZ�" BLOCK ��5UBDIVISION CASTI.GGry M '__ SEC/PH
BUSINESS/OWNER NAME:
PHONE:
Iv�
CONTRACTOR/HOMEOWNER: so U PHONE:
CONTRACTOR ADDRESS: 3�� ���� �Ai� �Q. ��'X7"1$ds
ELECTRICIAN: T S 1"8 PLUMBER: T;z)1PL.& 7
HVAC: GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION ` SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION" SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK:
PROPOSED USE: Sb6L& RM LLY Fdestp C�
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY ST NDARD (TAS) eBPJECT REGISTRATION# EABPRJ
VALUATION: $ WAM TOTAL AREA: HEATED AREA:
of Labor and Materials)
� .� 11%S? UBLICSEWER t 1S4/�.00 NUMBER OF BE
SEPTIC/TREATMENT SYSTEM
[Sj�<EWER TAP: 4,11
S E
&�GIATER TAP: 4
SIZE
OTHER TAP:
SIZE
❑ TEMP POLE
GARAGE TYPE: SINGLE F]
ATTACHED Fv�
NUMBER OF BATHROOMS: 3
INTERIOR WALL TYPE
EXTERIOR WALL TYPE
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE lie TRIPLE
DETACHED
SIGNATURE OF APPLICANT: / .UTAA/\ IVI
"If proposed work involves new commeltiarco structT dry
commercial property, building elevations are reNifise
Official Use
-S-7-oi
Plans Examiner
-✓ /` (✓1
CARPO
Zoning Official
ments:
CIE -4 rNO
mp
i
_ "Polk
i
ons to an existing
Fire Marshall
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER#
DATE:
BUILDING ADDRESS:
41Y 0 '.q.— /"T yr
I. Foundation Requirements- Minimum City Foundation Standards
NA/
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
OK
ll. Framing:
Floor, Wall, Ceiling and Roof Requirements
N NM
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
NA/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
K
IWOK
A. Stairway Details
OK
1.
Maximum riser height 7-3/4 inches
2.
Minimum tread width 10 inches
3.
Stairway risers are uniform 3/8" Max. difference
4.
Stairway width not less than 36 inches
5.
Stairway headroom not less that six ft. eight 6-8
B. Winder details
1.
Treads a minimum of six 6 inches on narrow edge
2.
Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1.
Riser height less than nine and one-half 9-1/2 inches
2.
Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3.
Stairway width not less than thirty-six inches
4.
Headroom required not less than six ft six 6-6 inches
5.
All treads must be identical
D. Guards/handrail details
1.
Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2.
Handrails are required on stairways located two or more risers above floor/grade
3.
Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4.
Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5.
Guards must be a minimum of thirty-six 36 inches above finished floor
6.
Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
NA/
A. Hearth extensions
1.
Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2.
Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry
fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/
1.
Electrical fixtures & switches indicated
2.
Smoke detector locations indicated as required
3.
GFI circuits indicated where required
4.
Arc fault protection for bedroom circuits
5.
Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
NOIC
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
No
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NA/
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NNQQ
Permitted use for district
77
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N Akb
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NAM
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
K
"APPROVED PLANS PER IRC SECTION R106.3.1."
/ 7,ol
LANS EXAMI ER DATE
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\l520BF.rck
TITLE: 4405 Hearst Court
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 04/30/07
DATE OF PLANS: 8/13/05
PROJECT INFORMATION:
Lot 52 Block 3
Castlegate Subdivision
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
NOTES:
Preacher Plan
5-BED WITH BOXED BAY WINDOWS
COMPLIANCE: Passes
Maximum UA = 747
Your Home UA = 571
23.6% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.38
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Front
Projection factor: 0.23
Door 1: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Left Side
Projection factor: 0.27
Wall 3: Wood Frame, 16" o.c.
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
2300
30.0
0.0
81
396
15.0
0.0
22
73
0.600 44
38
484 15.0 0.0
31
396 15.0 0.0
0.400 15
35
0.600 19
24
Window 3: Metal Frame:Double Pane with Low-E 68 0.600 41
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Back
Projection factor: 0.27
Door 2: Glass 18 0.580 10
SHGC: 0.78
Bldg. faces 180 deg. from North; Comp. orient.: Back
Projection factor: 1.02
Wall 4: Wood Frame, 16" o.c. 484 15.0 0.0 35
Window 4: Metal Frame:Double Pane with Low-E 27 0.600 16
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Right Side
Projection factor: 0.27
Floor 1: Slab-On-Grade:Unheated 220 0.0 229
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 13 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release lb (formerly MECchec4 and to comply with the mandatory requirements listed in
the RESchecklnspec ' ckli .
Builder/Designer,Date
r)0 "Y" 0c4l,ire 0 w " e t116!,urveIIng,
L3�'BEf iYXEE�G/ci f.RliUl�5U,4Y ylNG,AV-fff fkvbr aft Avhb W,CaftwSUM, rezu W-(YrWJ&VWd
Lot 52 Mock 03 S05.drq
%J f �
01��o'I`Qq• /�
Scale:
Jki
o1 �o f'
z
Lot 62
1ld q1' G Now or Formerly
Su v/ • Y
`tp G6st t +rAd /� ` Oovd I71 i Kathryn L�wim
t lJ 1 Vol.l. 7105, Pg. 178
po rf
P9
,.--
100
lot
00
13,g
4 4405 Heorsf Covet 6.s.
5L. �Ot 52 1 1
4 Bloak 49
Casthgato Sub V41on ,
,� ,Sed on A Phase 2 m 1 ! !
Now o� o3rn,.r1 tu I ; V N87, P.128 h 31 Lot 51
Ofura Pro-'riv Invest rya, Ltd. lot ! Now or Fom,wly
Yol. 71417, Pg. 120 1 Slorm Moto Constr. Inc.
4 Proposal 1 1 Vol. 77M, Pg. 35
� IPaxidenca �1
4 701 14.2' yJ
�.
5' P.U.E.
LOS f19c7/S!� G'pUlt` ~..�, L1NE T.ABtE
LINE BE06RING DISTANCE
Jar A0W. Lt N 8752';7' E 8.81'
OW 7187, Pg 128 L2 S 01'32'24" E 45.79'
CURIE ;TABLE
CURVE DELTA RADIUS LENarH CHORD. SAG.
cl 14'03'11' 225.W 55.19' N 72'16'2r w