HomeMy WebLinkAboutRES2007-01374 135 WALCOURT LOOP BUILDING PERMITPREPARED 8/28/07, 11:59:08 INSPECTION TICKET PAGE 8
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/28/07
------------------------------------------------------------------------------------------------
ADDRESS . : 135 WALCOURT LOOP SUBDIV: EDELWEISS GARTENS PH 9
CONTRACTOR BENCHMARK - DBA G D T INC PHONE (979) 690-7117
OWNER EDELWEISS GARTEN VENTURE PHONE
PARCEL 244030-0928-0080
•APPL NUMBER: 07-00001374 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B10'0 01 5/15/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00
5/15/07 AP May 15, 2007 12:01:30 PM glsouth.
05/15/2007 04:35 PM RH PDA
Strings up, slab ground installed.
B115 01 6/19/07 OC BLDG, FRAMING TIME: 17:00
- 6/19/07 AP
June 19, 2007 1:04:09 PM kwolfe.
B130 01 6/26/07 BH BLDG, INSULATION TIME: 17:00
6/26/07 AP June 26, 2007 4:07:37 PM kwolfe.
June 26, 2007 4:07:53 PM kwolfe.
B125 01 / 8/ 7�% AI
BLDG, FINAL TIME: 17:00
M/0! Y � August 28, 2007 10:57:54 AM glsouth.
-------------------------------------- COMMENTS AND NOTES--------------------------------------
9 �
Date 8/28/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1374
Address: 135 WALCOURT LOOP
Type
inspection Type Code
p.
status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
05/15/2007 04:35 PM RH PDA
B100
BLDG, FOUNDATION -SLAB
IC
Strings up, slab ground installed.
B130
BLDG, INSULATION
IC
June 26, 2007 4:07:53 PM kwolfe.
E150
ELEC, FINAL
IC
08/24/2007 05:00 PM JGM PDA
E150
ELEC, FINAL
IC
missing gfi plug in island, counter plug in kitchen need
E150
ELEC, FINAL
IC
to be gfi protected, missing smoke detector in front
Page 1
(6/26/2007) Kim Wolfe - Insulation request inspection result, 135 Walcourt Loop, #07-1374 Page 1
From: Brian Henry
To: Southerland, Gina
Date: 6/26/2007 4:01 PM
Subject: Insulation request inspection result, 135 Walcourt Loop, #07-1374
CC: Carter, Amber; Wolfe, Kim
Print for file
Inspected insulation, 135 Walcourt Loop, #07-1374, Benchmark Homes, 6-26-07
Inspection result: Inspected OK for Good Cents
Date: 8/24/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1374
Address: 135 WALCOURT LOOP
Type
Inspection Type Code
status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
05/15/2007 04:35 PM RH PDA
B100
BLDG, FOUNDATION -SLAB
IC
Strings up, slab ground installed.
B130
BLDG, INSULATION
IC
June 26, 2007 4:07:53 PM kwolfe.
Page 1
WF0898257 / 001 City of College Station
PAGE 1
REQ. DATE: 05/08/07 05/08/07 16:56:12
LOCATION: 135 WALCOURT LOOP LOC ID: 203592
REQUESTOR: BENCHMARK - DBA GDT, INC ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
4" SWR TAP 3/4" WTR TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 05/08/07 SCHED COMPLETION: 05/08/07
********************************************************************************
JOB ORDER RESULT COMU24TS
(8/30/2007) Gina Southerland - Re: Calling for CO @ 135 Walcourt Loop
Pagel
From: Mitchell Carson
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 8/28/2007 2:06 PM
Subject: Re: Calling for CO @ 135 Walcourt Loop
This one is OK Mitch
>>> Kim Wolfe 08/28/07 12:05 PM >>>
any issues?
BP # 07-1374
Thanks
Kimberly Wolfe, CPS/CAP
City of College Station
Planning & Development Services
(979) 764-3570
www.cstx.4ov
BUILDING PERMIT
CITY OF COLLEGE STATION
110t1 TEAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
------------------------------------ I ----------------------------------------
Application Number .
. . . . 07-00001374 Date 5/08/07
Application pin number
. . . 439288
Property Address . .
. . . . 135 WALCOURT LOOP
Property ID:
244030-0928-0080
R #:
R303278
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . EDELWEISS GARTENS PH 9
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 115368
Owner
Contractor
------------------------
EDELWEISS GARTEN VENTURE
------------------------
BENCHMARK - DBA G
D T INC
311 CECILIA LOOP
1110 12TH MAN CIR
COLLEGE STATION
TX 778456310 COLLEGE STATION
TX 77845
(979) 690-7117
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1748.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
KW
Permit pin number .
501254
Permit Fee . . . .
508.00 Plan Check Fee
.00
Issue Date . . . .
5/08/07 Valuation . . .
. 115368
Expiration Date . .
11/04/07
Qty Unit Charge
Per
Extension
BASE FEE
460.00
16.00 3.0000
THOU BLDG, VAL 100001-500000
48.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
---------------------------------
BUILDING DEPT �RESPNTATI
----- -- - -
------------
APPLICANT
BUILDING PERMIT
CITY OF COLLEGE STATION
1161 TEkAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 07-00001374 Date 5/08/07
Application pin number . . . 439288
----------------------------------------------------------------------------
Special Notes and Comments
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
----------------------------------- - - - - -- 4 - - - - - h7-- .9---7--s-_-------------
BUILDING DEPT REPRESENTA'
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1161 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00001374 Date 5/08/07
Application pin number . . . 439288
----------------------------------------------------------------------------
Special Notes and Comments
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
------------------------------------------ L---- -------------
BUILDING DEPT REPTENT�TT
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
11 b l TEAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 4
Application Number . . . . . 07-00001374 Date 5/08/07
Application pin number . . . 439288
----------------------------------------------------------------------------
Special Notes and Comments
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
Narrow Wall Bracing Fully Sheathed with Interior Anchors and
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
Bracing to the left of Front door area.
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP
4"
350.00
WATER TAP
3/4"
400.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid
----------
Credited
--------------------
Due
Permit Fee Total
508.00
508.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1258.00
1258.00
.00
.00
BUILDING DE
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
07-00001375 Date 5/08/07
Application pin number . . .
541500
Property Address . . . . . .
135 WALCOURT LOOP
Property ID:
244030-0928-0080
R #:
R303278
Application type description
TEMP POLE
Subdivision Name . . . . . .
EDELWEISS GARTENS PH 9
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
EDELWEISS GARTEN VENTURE
------------------------
BENCHMARK - DBA G D
T INC
311 CECILIA LOOP
1110 12TH MAN CIR
COLLEGE STATION TX 778456310
COLLEGE STATION
TX 77845
(979) 690-7117
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . KW
Permit pin number . 501262
Permit Fee . . . . 20.00
Issue Date . . . . 5/08/07
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
-------------------
BUILDING DE
APPLICANT:
I ,
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION l, WWW.CSTX.GOV
Planning&De IopniintSetvices
ADDRESS/LOCATION: ' 55 WA �
LOT �`� BLOCK —as_t/SUBDIVISION
F 01fte Use Only
DATE. RCC REG
APPLICATION # ^i 3j
TEMP POLE # Q -- 1 � 55
�/PH /
BUSINESS/OWNER NAME: (SeT IN (a— 1 `�j,����� PHONE: q7q-wiq-7#/
CONTRACTOR/HOMEOWNER: b6T.X W' 1tA ` A 6 ►w PHONE:
CONTRACTOR ADDRESS:�1l
ELECTRICIAN: A, C 1 "- c— PLUMBER:
HVAC: C'm4A QOpl '� k3�' Ai R, GOOD CENTS (Residential only): �S
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) >< NEW CONSTRUCTION " SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION" SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK: L� NS _ ��,
ta�IPROPOSED USE: %r�JG,F- �"Ptm41,�n r ��n)`+�A
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: 46— 5
TEXAS ACCESSIBILITY STANDARD OJECT REGISTRATION# EABPRJ
VALUATION: $ flv TOTAL AREA: Z32C) HEATED AREA:
(Cost of Labor and Materials) (��j �j V
A PUBLIC SEWER " I " NUMBER OF BEDROOMS:
❑ SEPTIC/TREATMENT SYSTEM I
® SEWER TAP: t
SIZE
® WATER TAP: 3 t f
SIZE
OTHER TAP:
SIZE
1,24
TEMP POLE
GARAGE TYPE: SINGLE
ATTACHED 57<
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE
TRIPLE 71
ACHED F__] CARPORT F7
SIGNATURE OF APPLICANT:
"If proposed work involves new commercial co struction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
1 y0 Plans Examiner
U (9 — to eji 6'Vf
Zoning Official
Comments:
(T)orNO
Fire Marshall
6C&CI1he3 �- 41" w s
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# _ /3 L/
DATE:
SD - 3 - `7
BUILDING ADDRESS:
a I Go v44
I. Foundation Requirements- Minimum City Foundation Standards
NAB
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
N OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NAM
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
WA10K
E.
Header sizes indicated on plans
N AM
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing plan or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
Z
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within T of property line to have protected openings.
III. Stairway Requirements
OK
ffOK
A. Stairway Details
OK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less, than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N1Aqdq
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
T
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N K
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NA/
Does not block any water course or divert any flow
Elevation certificate needed
&tbK
"APPROVED PLANS PER IRC SECTION R106.3.1."
1/_1 V � 4
PL INER
DATE
1b
REScheck Software Version 4.0.1
Compliance Certificate
Project Title: Benchmark Homes #293
Report Date: 05/03/07
Data filename: C:\Program Files\Check\REScheck\REScheck docs\293BM.rck
Energy Code: 20031ECC
Location: College Station, Texas
Construction Type: Single Family
Glazing Area Percentage: 14%
Heating Degree Days: 1788
Construction Site: Owner/Agent:
135 Walcort Loop Glenn Thomas
College Station, , TX 77845 GDT Inc. dba Benchmark Homes
Permit Date: May 3. 2007 1110 12th Man Court
College Station, TX 77845
979 690 7117 or 412 5171
benchmarkhomesbcs@hotmail.com
Maximum SHGC: 0.40 Your SHGC: 0.34
Designer/Contractor:
Glenn Thomas
GDT Inc. dba Benchmark Homes
1110 12th Man Court
College Station„ TX 77845
979 690 7117 or 412 5171
benchmarkhomesbcs@hotmail.com
Ceiling 1: Flat Ceiling or Scissor Truss: 1748 30.0 0.0
61
Wall 1: Wood Frame, 16" o.c.: 1672 13.0 3.4
99
Window 1: Metal Frame:Double Pane with Low-E: 177 0.570
101
SHGC: 0.34
Door 1: Solid: 21 0.630
13
Door 2: Glass: 54 0.630
34
SHGC: 0.34
Floor 1: Slab -On -Grade: Unheated: 209 0.0
218
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air: 14 SEER
Furnace 1: Forced Hot Air: 80 AFUE
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in
REScheck Version 4.0.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name - Title Signature Date
Project Notes:
Job 293
135 Walcort Loop
Lot 8 Block 28 Edelweiss Gartens 9
College Station, Texas 77845
Benchmark Homes
1110 12th Man Court
College Station, Tx 77845
Like Home at 4207 Walcourt
Benchmark Homes #293 Page 1 of 4
REScheck Software Version 4.0.1
Inspection Checklist
Date: 05/03/07
Ceilings:
❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
Above -Grade Walls:
❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity + R-3.4 continuous insulation
Comments:
Windows:
❑ Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.570
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? _
Comments:
Doors:
❑ Door 1: Solid, U-factor: 0.630
Comments:
❑ Door 2: Glass, U-factor: 0.630
Comments:
Floors:
❑ Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
❑ Air Conditioner 1: Electric Central Air. 14 SEER or higher
Make and Model Number:
❑ Furnace 1: Forced Hot Air: 80 AFUE or higher
Make and Model Number:
Yes No
Solar Heat Gain Coefficient:
❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values are determined in
accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed.
❑ Recessed lights are 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from
combustible materials. If non -IC rated, fixtures are installed with a 3" clearance from insulation.
Skylights:
❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-13.
Materials Identification:
❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions.
❑ Materials and equipment are identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
Benchmark Homes #293 Page 2 of 4
Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency are clearly marked on the building plans or
specifications.
❑ Insulation is installed according to manufacturers instructions, in substantial contact with the surface being insulated, and in a
manner that achieves the rated R-value without compressing the insulation.
Duct Insulation:
Supply ducts in unconditioned attics or outside the building are insulated to R-8.
Return ducts in unconditioned attics or outside the building are insulated to R-4.
Supply ducts in unconditioned spaces are insulated to R-6.
❑ Return ducts in unconditioned spaces (except basements) are insulated to R-2. Insulation is not required on return ducts in
basements.
❑ Where exterior walls are used as plenums, the wall is insulated to R-8.
Duct Construction:
Duct connections to flanges of air distribution system equipment are sealed and mechanically fastened.
Lj All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric,
or tapes. Tapes and mastics are rated UL 181 A or UL 181 B.
Exceptions:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa).
0 The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
❑ Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or
cooling input to each zone or floor is provided.
Service Water Heating:
Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat
trap or is part of a circulating system.
O Circulating hot water pipes are insulated to the levels in Table 1.
Circulating Hot Water Systems:
rl Circulating hot water pipes are insulated to the levels in Table 1.
Swimming Pools:
Lj All heated swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depletable
sources. Pool pumps have a time dock.
Heating and Cooling Piping Insulation:
Lj HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
Benchmark Homes #293 Page 3 of 4
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non -Circulating Runouts
Circulating Mains and Runouts
Heated Water
Up to 1"
Up to 1.25"
1.5" to 2.0"
Over 2"
Temperature (°F)
170-180
0.5
1.0
1.5
2.0
140-169
0.5
0.5
1.0
1.5
100-139
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes
Insulation Thickness in Inches by Pipe Sizes
Fluid Temp.
Piping System Types
Range ff)
2" Runouts 1" and Less
1.25" to 2.0" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
106-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant and
40-55
0.5
0.5
0.75
1.0
Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD: (Building Department Use Only)
Benchmark Homes #293 Page 4 of 4
I$f
..�- �O�i�� — cam= `�Si�c iS5 l ._ �'►�'J