HomeMy WebLinkAboutRES2007-01370 1601 LEOPARD CT BUILDING PERMITWFO898124 / 001 City of College Static,,n , I PAGE 1
REQ. DATE: 05/08/07 05/08/07 15:14:57
LOCATION: 1601 LEOPARD CT LOC ID: 189720
REQUESTOR: LOUIS GASTON CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/4113
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 05/08/07 SCHED COMPLETION: 05/08/07
********************************************************************************
JOB ORDER RESULT COW4ENTS
PREPARED 10/12/07, 11:59:21 INSPECTION TICKET PAGE 1 4
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/12/07
------------------------------------------------------------------------------------------------
ADDRESS . : 1601 LEOPARD CT SUBDIV: CAT HOLLOW PH 2
CONTRACTOR LOUIS GASTON CUSTOM HOMES PHONE (979) 731-1734
OWNER ARROYO, RUBEN B & LILIA C PHONE
PARCEL 184500-0203-0120
APPL NUMBER: 07-00001370 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 5/24/07 DS BLDG, FOUNDATION -SLAB TIME: 17:00
5/24/07 AP May 24, 2007 12:44:59 PM glsouth.
B115 01 7/11/07 DS BLDG, FRAMING TIME: 17:00
7/11/07 AP July 10, 2007 1:04:09 PM kwolfe.
B130 01 7/18/07 BH BLDG, INSULATION TIME: 17:00
7/18/07 AP July 18, 2007 8:40:29 AM acarter.
July 18, 2007 8:40:38 AM acarter.
B125 01 10/12/07 BI BLDG, FINAL TIME: 17:00
0/c6 or1 &P ac-- October 12, 2007 9:45:39 AM glsouth.
-------------------------------------- COMMENTS AND NOTES --------------------------------------
4 e161 1 TrJta e' % S i�n3ta'/lect W----
Date. 10/12/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1370
Address: 1601 LEOPARD CT
Type
Inspection Type Code
siat�s
Inspection Result Comments
Description
B130
BLDG, INSULATION
IC
July 18, 2007 8:40:38 AM acarter.
Ell
ELEC, ROUGH IN
IC
07/06/2007 04:08 PM JGM PDA
Ell
ELEC, ROUGH IN
IC
box for jacuzzi
Page 1
- - -- - - - - -- - - -- - -- - - - - ------ -----
Amber Carter - Re. Calling for CO @ 1601 Leopard Ct
Page 1
From: Paul Schoenfeld
To: Amber Carter; Benjamin McCarty; Chris Haver; ...
Date: 10/12/2007 3:37 pm
Subject: Re: Calling for CO @ 1601 Leopard Ct
NO for CO.
Sewer manhole buried flagged.
Sewer cleanout buried flagged.
Water ok at this time. Yard not graded yet.
Paul
>>> Kim Wolfe 10/12/2007 12:25 PM >>>
any issues?
BP # 07-1370
Thanks
Kimberly Wolfe, CPS/CAP
City of College Station
Planning & Development Services
(979) 764-3570
www.cstx.gov
Amber Carter - Insulation request inspection result, 1601 Leopard Ct. #07-1370 Page 1
From: Brian Henry
To: Southerland, Gina
Date: 7/17/2007 3:15 pm
Subject: Insulation request inspection result, 1601 Leopard Ct. #07-1370
CC: Carter, Amber; Wolfe, Kim
Print for file
Inspected insulation, 1601 Leopard Ct. #07-1370, Louis Gaston Custom Homes, 7-17-07
Inspection result: Inspected OK for Good Cents
Notes:
Insulate top of window boxes.
Secure insulation batts above back door at vaulted ceiling.
(7/17/2007) Kim Wolfe - Insulation request inspection result, 1601 Leopard Ct. #07-1370 Page 1
From: Brian Henry
To: Southerland, Gina
Date: 7/17/2007 3:15 PM
Subject: Insulation request inspection result, 1601 Leopard Ct. #07-1370
CC: Carter, Amber; Wolfe, Kim
Print for file
Inspected insulation, 1601 Leopard Ct. #07-1370, Louis Gaston Custom Homes, 7-17-07
Inspection result: Inspected OK for Good Cents
Notes:
Insulate top of window boxes.
Secure insulation batts above back door at vaulted ceiling.
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 07-00001370 Date 5/03/07
Application pin number
. . . 576800
Property Address . .
. . . . 1601 LEOPARD CT
Property ID:
184500-0203-0120
R #:
R107441
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . CAT HOLLOW PH 2
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 135000
Owner
Contractor
------------------------
ARROYO, RUBEN B & LILIA
------------------------
C LOUIS GASTON CUSTOM HOMES
149 CHAPPELL RD
5830 EASTERLING DR.
HOLLISTER
CA 95023 BRYAN TX 77808
(979) 731-1734
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1876.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 226.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
GS
Permit pin number .
500108
Permit Fee . . . .
565.00 Plan Check Fee .00
Issue Date . . . .
5/03/07 Valuation . . . . 135000
Expiration Date . .
10/30/07
Qty Unit Charge
Per Extension
BASE FEE 460.00
35.00 3.0000
THOU BLDG, VAL 100001-500000 105.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTEDjBYAN ARC- AULT CIRCUIT
------------------------------- ---- A- - -----------------
BUILDING DEPT REPROENTATIVE:
APPLICANT:
BUILDING PERMIT
-- __CITY OF COLLEGE STATION
1101 TEXXS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00001370
Application pin number . . . 576800
Page 2
Date 5/03/07
----------------------------------------------------------------------------
Special Notes and Comments
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL ORISECIAL KNOWLEDGE/EFFORT
------------------------------------------------------�
BUILDING DEPT,.j�.EPREANT�T�E
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00001370 Date 5/03/07
Application pin number . . . 576800
----------------------------------------------------------------------------
Special Notes and Comments
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO IN ECTS AND DECAY.
------------------------------------------- ---- ) -�-----------
BUILDING DEPTEPENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number . . . . . 07-00001370 Date
5/03/07
Application pin number . . . 576800
----------------------------------------------------------------------------
Special Notes and Comments
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Narrow Wall Bracing Fully Sheathed with Simpson Panels at
each Garage Return.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
------------------------------
---------------------------
Permit Fee Total 565.00 565.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1315.00 1315.00 .00
.00
----------------------------------------------Y�J•- ---`------------
BUILDING DEPTPSENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101' TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
07-00001371 Date 5/03/07
Application pin number . . .
687440
Property Address . . . . . .
1601 LEOPARD CT
Property ID:
184500-0203-0120
R #:
R107441
Application type description
TEMP POLE
Subdivision Name . . . . . .
CAT HOLLOW PH 2
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
ARROYO, RUBEN B & LILIA C
------------------------
LOUIS GASTON CUSTOM
HOMES
149 CHAPPELL RD
5830 EASTERLING DR.
HOLLISTER CA 95023
BRYAN
TX 77808
(979) 731-1734
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . GS
Permit pin number . 500116
Permit Fee . . . . 20.00
Issue Date . . . . 5/03/07
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary Charged
Paid Credited
------------------------------
Due
---------------------------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
----------------------------------------------/LJ�- / ------+-----------
BUILDING DEPT REPRRSENTATIVE:
APPLICANT:
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION WWW.CSTX.GOV
Planning & Development Services
For Pffice Use Only
DATE. 0 1A I ()jCC REG ZSiS
APPLICATION #.()j
I ��
TEMP POLE # O
ADDRESS/LOCATION:
LOT /Z✓BLOCK _ SUBDIVISION �i¢ .11,oivt% SEC/PH
BUSINESS/OWNER NAME: . . PHONE:
CONTRACTOR/HOMEOWNER:,�L, � L (�IfiS+U nI PHONE: J/ z — / z z3
CONTRACTOR ADDRESS: SX.?V
ELECTRICIAN: PLUMBER:
HVAC: GOOD CENTS (Residential only):-4
r CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY ^ /�
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEURENOVATION* SWIMMING POOL v ,
TENT/CANOPY
DESCRIPTION OF WORK:
PROPOSED USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: �-
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ oa- TOTAL AREA: HEATED AREA: 14F74
(Cost of Labor and Materials) 3d�
21�PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
SEWER TAP: y es
SIZE
WATER TAP: 3�tF
SIZE
❑ OTHER TAP:
SIZE
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE
EXTERIOR WALL TYPE:
FOUNDATION TYPE
Z
FIRRININ
MEW
TEMP POLE ROOF TYPE:D.;��-�
GARAGE TYPE: SINGLE F__] DOUBLE ® TRIPLE a
ATTACHED 1,9 DETACHED F__j CARPORT
SIGNATURE OF APPLICANT:
*If proposed work involves new comme onstruction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
S- -
LjF
'P Plans Examiner
Zoning Official
Iy I!g �r e1 J ents:
v fit/ � � ES NOpl�vd-f e, C) �' 641e'ce
Fire Marshall
I*
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 6,7 13 D
DATE: S _ 3 — a'�
BUILDING ADDRESS:
Gar L�0
I. Foundation Requirements- Minimum City Foundation Standards
NA/
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
Aq410K
II. Framing: Floor, Wall, Ceiling and Roof Requirements
A/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
N
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
OK
8POK
A. Stairway Details
:rAOK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA'T
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N K
B. Plumbingaccess to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N AIOJg
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NAB
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NAQX
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N O
Maximum drive width for residence is 25' combined for circular and 12' minimum for —single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NAB
Does not block any water course or divert any flow
Elevation certificate needed
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
PL EXAMINER
.,-Z 01
"DATE