Loading...
HomeMy WebLinkAboutRMDL2007-01365 1215 ONEY HERVEY DR BUILDING PERMITCo^mF:CI"I .,5k foPQc�� V n J LDmmz)(�lu.l '4w, INry PREPARED 7/23/08, 12:07:24 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/23/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 1215 ONEY HERVEY DR SUBDIV: PECAN TREE ESTATES CONTRACTOR ACTION MAINTENANCE PHONE (979) 574-0800 OWNER HERVEY ONEY, LLC PHONE PARCEL 498500-0002-0150 APPL NUMBER: 07-00001365 RESIDENTIAL, REMODEL & RENOVATION ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B115 01 8/09/07 JGM BLDG, FRAMING TIME: 17:00 8/09/07 AP June 12, 2007 4:59:11 PM glsouth. AFTERNOON June 13, 2007 4:32:23 PM acarter. NEEDS ELEC AND MAYBE PLBG BEFORE FRAMING CAN BE DONE PER DAVID STONE B130 01 8/28/07 OC BLDG, INSULATION TIME: 17:00 8/28/07 AP August 26, 2007 11:35:50 AM kwolfe. August 28, 2007 1:25:09 PM ACARTER. B125 01 7/23/08 BI BLDG, FINAL TIME: 17:00 1ja3id- CO AP July 23, 2008 11:38:03 AM glsouth. -------------------------------------- COMMENTS AND NOTES -------------------------------------- BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS -.EVE 'U COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #• Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . Owner HERVEY ONEY, LLC 1209 MANHATTAN AVE 180 MANHATTAN BEACH CA 90266 07-00001365 Date 5/02/07 558990 1215 ONEY HERVEY DR 498500-0002-0150 R37542 RESIDENTIAL, REMODEL & RENOVATION PECAN TREE ESTATES RESIDENTIAL DUPLEX RESIDENTIAL 40000 Contractor ACTION MAINTENANCE 2151 HARVEY MITCHELL PKWY S 31 COLLEGE STATION TX 77840 (979) 574-0800 --- Structure Information 000 000 DUPLEX FIRE REBUILD Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . IMPACT/PRORATA FEES PAID NA HEATED AREA 1200.00 INTERIOR WALL TYPE VINYL NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 367.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number . 499863 Permit Fee . . . . 210.00 Plan Check Fee .00 Issue Date . . . . 5/02/07 Valuation . . . . 40000 Expiration Date . . 10/29/07 Qty Unit Charge Per Extension BASE FEE 15.00 39.00 5.0000 THOU BLDG, VAL 1001-50000 195.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQU PMENT AND WALKWAY ---------------------------------- ------ --.- ------------- BUILDING DEPT REPRESENTATIVE:"'d APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS .AVE r COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00001365 Application pin number . . . 558990 Page 2 Date 5/02/07 Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE 1 HOUR DUPLEX SEPERATION WALL MUST BE MAINTAINED FROM FLOOR TO ROOF DECKING. ALL PENETRATIONS MUST BE PROPERLY ADDRESSED AND MAINTAINED. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can he used if the a/c system has a SEER rating of 12 or more. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES - ------------------------------------ ----j6vi�r ---/r---------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE t COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00001365 Application pin number . . . 558990 Page 3 Date 5/02/07 Special Notes and Comments THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC) RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK All fire renovation must be done to current codes including 1 hour fire seperation wall between units, arc fault protection for bedrooms, smoke detector locations, framing including if stairs are rebuilt to meet 6" minimum rule, and any other code requirements not previously addressed. Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 210.00 210.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 210.00 210.00 .00 .00 -------------------------------------------- ----A.-�------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX CITY OF COLLEGE STATION WWW.CSTX.GOV Planning d Development Services For Office Use Only DATE 5 I Id OTRCC REG APPLICATION # TEMP POLE # NQ ADDRESS/LOCATION: cl/S 4?"ey � G/'t�e,ly LOT BLOCK SUBDIVISION SEC/PH BUSINESS/OWNER NAME: /�/l�/ kfAz y L C- PHONE: `' �! �'�O5o4 CONTRACTOR/HOMEOWNER: �iO� a�K�c'i��'J;IONE: JC/y/Z CONTRACTOR ADDRESS: ELECTRICIAN: ©�/y�i 1 PLUMBER: HVAC: "4 /' GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL l TENT/CANOPY /� DESCRIPTION OF WORK: / � &-4y� /� /� �"c 22—M 4!2 011 PROPOSED USE: HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ L%o2 < © TOTAL AREA: GC7 HEATED AREA: / Q (Cost of Labor and Materials) PUBLIC SEWER SEPTIC/TREATMENT SYSTEM ❑ SEWER TAP: SIZE ❑ WATER TAP: SIZE OTHER TAP: SIZE TEMP POLE GARAGE TYPE:, SINGLE ATTACHED NUMBER OF BEDROOMS NUMBER OF BATHROOMS INTERIOR WALL TYPE 3 EXTERIOR WALL TYPE: Vt ny FOUNDATION TYPE: o h G /G A— ROOF TYPE: GO> =P- DOUBLE F-1 TRIPLE IETACHED F—] CARPORT a SIGNATURE OF APPLICANT: *If proposed work involves new commer al construction or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only Plans Examiner Zoning Official 0- 40✓4;h0'v1 will ents: YES r NO - " Fire Marshall 0 ACTION MAINTENANCE 2151 Harvey Mitchell Pkwy. #315 COLLEGE STATION TX. 77840 Phone 979-574-0800 ESTIMATE DATE:4-19-2007 TO: FOR SERVICES AT: ATTN. CITY OF COLLEGE STATION 1215 ONEY HERVEY BUILDING INSPECTIONS -PERMITS DESCRIPTION AMOUNT WE WILL REMOVE ALL FIRE DAMAGED WALLS AND ROOF INCLUDING ANY DAMEGED FRAMING BETWEEN FLOORS. ALL NEW FRAMING WILL BE BROUGHT TO MOST RECENT CODE UPDATES. WIRING WILL BE REPLACED BY LICENSED ELECTRICIAL CONTRACTOR PLUMBING AND H.V.A.C. AS WELL WILL BE CONTRACTED TO LICENSED CONTRACTORS. ROOF IS CONTRACTED AS WELL. ALL SHEETROCK WILL BE REPLACED AS WELL AS TRIM CABINETS ETC. BY ACTION MAINTENANCE ALL DAMAGED WALLS AND ROOF ARE HIGHLIGHTED ON PLANS SUBMITTED WITH THIS LETTER. TOTAL Thank you for your business!