HomeMy WebLinkAboutRES2007-01362 4343 SPRING GARDEN DR BUILDNG PERMIT(7/24/2007) Gina Southerland - Re: Calling for C.O. @ 4343 Spring Garden Dr. Page 1
From: Paul Schoenfeld
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 7/24/2007 3:37 PM
Subject: Re: Calling for C.O. @ 4343 Spring Garden Dr.
ALL OK.
PAUL
>>> Gina Southerland 7/23/2007 8:22 AM >>>
BP# 07-1362
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.csbc.gov
PREPARED
7/23/07,
7:56:51
INSPECTION TICKET
PAGE 9
City of
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 7/20/07
------------------------------------------------------------------------------------------------
ADDRESS
. : 4343 SPRING
GARDEN
DR SUBDIV: SPRING CREEK
GARDENS PH 2
CONTRACTOR NEW VISION
CUSTOM HOMES PHONE (979) 220-2325
OWNER
SPRING
CREEK CS DEVELOPMENT PHONE
PARCEL
582881-0201-0210
APPL NUMBER: 07-00001362
RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
5/10/07
OC
BLDG, FOUNDATION -SLAB TIME: 17:00
5/10/07
AP
May 9, 2007 2:06:11 PM kwolfe.
afternoon
Strings On Setbacks O.K.
Slab Ground Installed
B115 01
6/05/07
OC
BLDG, FRAMING TIME: 17:00
6/05/07
AP
June 4, 2007 1:29:47 PM kwolfe.
B130 01
6/06/07
OC
BLDG, INSULATION TIME: 17:00
6/06/07
AP
June 5, 2007 2:36:58 PM kwolfe.
afternoon
B125 01
7/20/07
BBII�
BLDG, FINAL TIME: 17:00
,.
July 20, 2007 4:13:21 PM glsouth.
-----------------------------------
r
COMMENTS AND NOTES --------------------------------------
Date. 7/23/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1362
Address: 4343 SPRING GARDEN DR
Type
Inspection Type Code
si ins
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
M110
MECH, FINAL
IC
July 19, 2007 11:56:27 AM kwolfe.
Page 1
WF0896389 / 001 City of College Station
0%
PAGE 1
REQ. DATE: 05/04/07 05/04/07 15:27:24
LOCATION: 4343 SPRING GARDEN DR LOC ID: 205134
REQUESTOR: NEW VISION CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: NCOCHRAN AUTH USER:NCOCHRAN WRK TYPE:
4" SWR TAP 3/4" WTR TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 05/04/07 SCHED COMPLETION: 05/04/07
********************************************************************************
JOB ORDER RESULT COMMENTS
BUILDING -PERMIT
CITY OF COLLEGE STATION
r 1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application'Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #:
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
07-00001362 Date 5/04/07
212164
4343 SPRING GARDEN DR
582881-0201-0210
R304247
RESIDENTIAL, 1 UNIT DETACHED NEW
SPRING CREEK GARDENS PH 2
RESIDENTIAL
PLANNED DEVL HOUSING
110500
Owner Contractor
SPRING CREEK CS DEVELOPMENT NEW VISION CUSTOM HOMES
LTD P.O. BOX 86
4490 CASTLEGATE DR WELLBORN TX 77881
COLLEGE STATION TX 778453388 (979) 220-2325
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1171.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 427.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . NC
Permit pin number . 500512
Permit Fee . . . . 493.00 Plan Check Fee .00
Issue Date . . . . 5/04/07 Valuation . . . . 110500
Expiration Date . . 10/31/07
Qty Unit Charge Per Extension
BASE FEE 460.00
11.00 3.0000 THOU BLDG, VAL 100001-500000 33.00
----------------------------------------------------------------------------
Special Notes and Comments
Narrow Wall Bracing Fully Sheathed with 8" mmum arag
BUILDING DEPT REPRESENTATePVEi
APPLICANT: ( V-
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00001362
Application pin number . . . 212164
Page 2
Date 5/04/07
Special Notes and Comments
Framing.
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR
ATTACHED GARAGES SHALL HAVE
PENETRATIONS SEALED
Assure Proper GFI Locations,
Outside A/C Unit
GARAGE DOOR HEADER
ALL TOP PLATE AND HEADER
Including One Within 25' Of
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
------------------------------------------
------,� -- -- --4e-------- - - - - --
BUILDING DEPT
APPLICANT:
REPRESENTATIVE:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00001362 Date 5/04/07
Application pin number . . . 212164
----------------------------------------------------------------------------
Special Notes and Comments
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
----------------------------------./_------
BUILDING DEPT REPRESENTATIVE: Awl, �__ �
APPLICANT: Q___,4V.
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 4
Application Number . . . . . 07-00001362 Date 5/04/07
Application pin number . . . 212164
----------------------------------------------------------------------------
Special Notes and Comments
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP
4"
350.00
WATER TAP
3/4"
400.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid
----------
Credited
--------------------
Due
Permit Fee Total
493.00
493.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1243.00
1243.00
.00
.00
------------------------------------------- 4------4---,,4--- -,/ ------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION WWW.CSTX.GOV
u Planning c5 Development Snvns
ADDRESS/LCATION: / T, )—
LOT �-1 " BLOCK �_✓SUBDIVISION
BUSINESS/OWNER NAME:
CONTRACTOR/HOMEOWNER:
For Office Use Only
DATE. ' RCC REG -
APPLICATION #
TEMP POLE #
en_ art u-PJ
CV-q- en SEC/PH_
PHONE: (ob4-- n716
PHONE: og -a3D-
CONTRACTOR ADDRESS: `1'. wct( Qd' % f
ELECTRICIAN: L- PLUMBER: ` �I Umyl
HVAC: S6FJ± 7k/C GOOD CENTS (Residential only): —'
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION " SLAB ONL
DUPLEX (Landscape Plans) REMODEL/RENOVATION' SWIM P
+ T Y pv�
DESCRIPTION OF WORK:
PROPOSED USE:Ilk
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW C
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION#7
VALUATION: $ I `� 1 16, 5 ODJr OD r/ TOTAL AREA: � rl
(Cost of Labor and Materi Is)
D PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
191"SEWER TAP: `�i/"/I
SIZE
D4ATER TAP: 3 /)
SIZE
OTHER TAP:
SIZE
❑ TEMP POLE
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE
HEA
J
_r,:SrtaC__,
yak
c.
GARAGE TYPE: SINGLE DOUBLE TRIPLE a
ATTACHED DETACHED Q� CARPORT
SIGNATURE OF APPLICANT: /v
`If proposed work involves new commercial conAuction or facade improvements/renovations to an existing
commercial property, building elevations are re uired.
Official Use Only
S-a-o
Plans Examiner
�U y ski wt Na IV nil)
GAAAje f-t.Awt',l
EXTERIOR WALL TYPE
FOUNDATION TYPE:
ROOF TYPE:
Zoning Official
C ents:
ES r NO
Fire Marshall
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER#
0'7- 136a
DATE:
5 - 2--0'7
BUILDING ADDRESS: ....43' /3
`7r - 5012 �,,, 64.4.1.4.
I. Foundation Requirements- Minimum City Found ion StAndards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
K
II. Framing: Floor, Wall, Ceiling and Roof Requirements
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
Nq/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
6WOK
K
A. Stairway Details
K
1.
Maximum riser height 7-3/4 inches
2.
Minimum tread width 10 inches
3.
Stairway risers are uniform 3/8" Max. difference
4.
Stairway width not less than 36 inches
5.
Stairway headroom not less that six ft. eight 6-8
B. Winder details
1.
Treads a minimum of six 6 inches on narrow edge
2.
Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1.
Riser height less than nine and one-half 9-1/2 inches
2.
Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3.
Stairway width not less than thirty-six inches
4.
Headroom required not less than six ft six 6-6 inches
5.
All treads must be identical
D. Guards/handrail details
1.
Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2.
Handrails are required on stairways located two or more risers above floor/grade
3.
Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4.
Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5.
Guards must be a minimum of thirty-six 36 inches above finished floor
6.
Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
OK
A. Hearth extensions
1.
Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2.
Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry
fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NAqW
1.
Electrical fixtures & switches indicated
2.
Smoke detector locations indicated as required
3.
GFI circuits indicated where required
4.
Arc fault protection for bedroom circuits
5.
Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NAOW
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
_4
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
PLANS EXAMINER
5_-J,%-07
DATE
0
L0
i
in
w
-
o
I
I
I
z1
48'-51,
48'-I"
—w
Z-----
PROPER LINE: 127.00' - N
-- I --
DING SIFTBACK
-----------
e
20'-(o"
I
I
48'Iq'45" W I
-- —
LINE
---
w
-
o
NI
YI
I
Z
wl
QI
Z
o
�I
w
Iw
to
�I
NI
R tD'
CIE
�i
FI
oI
I o
L;
cal
I�
w
z
u1
fiI
�I
�
�I
w
of
.0 BUILDING SETBACK
LINE
Lu
al
PROPE LINE: 127.00' - N
48'Iq'45" W
0.
I
I
I
I
48' -1 "
20' -6"
ol SITE FLAN ,.. 20'�(o
REFERENCE -NONE 5CALE.
LOTi 21
BLOCKe 01
SUBDIVISIONt
SPRING CREEK GARDENS
PHASE 2
COLLEGE STATION, TX