HomeMy WebLinkAboutRES2007-01355 815 PASLER ST BUILDING PERMITPREPARED
8/15/07, 11:37:46
INSPECTION TICKET
PAGE 15
City of
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 8/15/07
------------------------------------------------------------------------------------------------
ADDRESS
. : 815 PASLER ST
SUBDIV: PASLER
CONTRACTOR W R TUBBS CONSTRUCTION PHONE (979) 412-0674
OWNER
JAFFAR, SHABEER
PHONE
PARCEL
496500-0001-0110
APPL NUMBER: 07-00001355 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
5/22/07 DS
BLDG, FOUNDATION -SLAB TIME: 17:00
5/22/07 DP
May 22, 2007 11:30:22 AM malford.
05/22/2007 04:47 PM DS PDA
needs min 3 inch bellow grade beams need chairs
string
or
all 4 sides of slab some beams have cav in from
the rain
B100 02
5/23/07 DS
BLDG, FOUNDATION -SLAB TIME: 17:00
•
5/23/07 AP
May 23, 2007 10:23:00 AM acarter.
B115 01
6/15/07 DS
BLDG, FRAMING TIME: 17:00
6/15/07 DP
June 14, 2007 4:12:42 PM acarter.
06/15/2007 11:20 AM DS PDA
needs fireplace installed to for clearance and combustile
material need anchor bolts around frontdoor
needs
anchor bolts within 12" of sole plate ends
B130 01
6/15/07 BI
BLDG, INSULATION TIME: 17:00
6/15/07 CA
June 15, 2007 12:38:46 PM acarter.
B115 02 6/18/07 JGM
6/19/07 DP
B130 02 6/18/07 JGM
6/19/07 DP
B115 03 6/21/07 DS
6/21/07 AP
B130 03 6/21/07 DS
6/21/07 AP
B125 01 8/14/07 DS
8/14/07 CA
B125 02
BLDG, FRAMING TIME: 17:00
June 18, 2007 8:09:15 AM acarter.
06/19/2007 08:48 AM JGM PDA
need to sheetrock over fireplace, need
to fix overstuffed
areas on insulation
BLDG, INSULATION TIME: 17:00
June 18, 2007 8:09:30 AM acarter.
06/19/2007 08:48 AM JGM PDA
need to sheetrock over fireplace, need
to fix overstuffed
areas on insulation
BLDG, FRAMING TIME: 17:00
June 21, 2007 10:57:39 AM acarter.
C
BLDG, INSULATION TIME: 17:00
`
June 21, 2007 10:57:52 AM acarter.
BLDG, FINAL TIME: 17:00
August 10, 2007 11:11:19 AM kwolfe.
08/14/2007 05:08 PM DS PDA
ctric final red tagged
G, FINAL TIME: 17:00
fug
ust 15, 2007 10:18:55 AM glsouth.
PREPARED 8/15/07, 11:37:46 INSPECTION TICKET PAGE 16
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/15/07
------------------------------------------------------------------------------------------------
ADDRESS . : 815 PASLER ST SUBDIV: PASLER
CONTRACTOR W R TUBBS CONSTRUCTION PHONE (979) 412-0674
OWNER JAFFAR, SHABEER PHONE
PARCEL 496500-0001-0110
APPL NUMBER: 07-00001355 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: ELEN 00 NEW ELECTRIC PERMIT SUB: GLENN'S ELECTRIC
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
E110 01 6/13/07 DS ELEC, ROUGH IN TIME: 17:00
6/13/07 DP June 13, 2007 8:05:57 AM acarter.
June 13, 2007 11:43:27 AM kwolfe.
bond all metal boxes; panel can not be located in closet;
add outlet on left wall going into dinning/kitchen area
E110 02 6/14/07 DS ELEC, ROUGH IN TIME: 17:00
6/14/07 AP June 14, 2007 8:24:48 AM kwolfe.
E150 01 8/08/07 JGM ELEC, FINAL TIME: 17:00
8/09/07 DP August 8, 2007 3:07:21 PM acarter.
08/09/2007 04:53 PM JGM PDA
not hot not ready
E150 02 8/14/07 DS ELEC, FINAL TIME: 17:00
8/14/07 DP August 10, 2007 11:50:14 AM acarter.
August 14, 2007 5:01:32 PM acarter.
Closet lights too close to shelves in back two bedrooms.
Closet lights need to be on arc fault circuits
Back two bedrooms not on arc fault breakers
Meter height man 5' 6" to center
Seal around riser going through soffit
Finish labeling panel
E150 03 � / /07 I� � ELEC, FINAL TIME: 17:00
gust 15, 2007 8:33:59 AM kwolfe.
-------- ----------------A-�COMMENTS AND NOTES --------------------------------------
�JA
0
5g' ��L
Date: 8/15/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1355
Address: 815 PASLER ST
Insp.
inspection Type Code
Description
Insp
Status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
05/22/2007 04:47 PM IDS PDA
B100
BLDG, FOUNDATION -SLAB
IC
needs min 3 inch bellow grade beams need chairs string
B100
BLDG, FOUNDATION -SLAB
IC
all 4 sides of slab some beams have cav in from the rain
B115
BLDG, FRAMING
IC
06/15/2007 11:20 AM IDS PDA
B115
BLDG, FRAMING
IC
needs fireplace installed to for clearance and combustile
B115
BLDG, FRAMING
IC
material need anchor bolts around frontdoor needs
B115
BLDG, FRAMING
IC
anchor bolts within 12" of sole plate ends
B115
BLDG, FRAMING
IC
06/19/2007 08:48 AM JGM PDA
B115
BLDG, FRAMING
IC
need to sheetrock over fireplace, need to fix overstuffed
B115
BLDG, FRAMING
IC
areas on insulation
B125
BLDG, FINAL
IC
08/14/2007 05:08 PM- DS PDA
B125
BLDG, FINAL
IC
electric final red tagged
B130
BLDG, INSULATION
IC
06/19/2007 08:48 AM JGM PDA
B130
BLDG, INSULATION
IC
need to sheetrock over fireplace, need to fix overstuffed
B130
BLDG, INSULATION
IC
areas on insulation
E110
ELEC, ROUGH IN
IC
June 13, 2007 11:43:27 AM kwolfe.
E110
ELEC, ROUGH IN
IC
bond all metal boxes; panel can not be located in closet;
E110
ELEC, ROUGH IN
IC
add outlet on left wall going into dinning/kitchen area
E150
ELEC, FINAL
IC
08/09/2007 04:53 PM JGM PDA
E150
ELEC, FINAL
IC
not hot not ready
E150
ELEC, FINAL
IC
August 14, 2007 5:01:32 PM acarter.
E150
ELEC, FINAL
IC
Closet lights too close to shelves in back two bedrooms.
E150
ELEC, FINAL
IC
Closet lights need to be on arc fault circuits
E150
ELEC, FINAL
IC
Back two bedrooms not on arc fault breakers
E150
ELEC, FINAL
IC
Meter height man 5' 6" to center
E150
ELEC, FINAL
IC
Seal around riser going through soffit
E150
ELEC, FINAL
IC
Finish labeling panel
Page 1
t_ '
WF0895763 / 001 City of 'College Station
PAGE 1
REQ. DATE: 05/03/07 05/03/07 14:34:27
LOCATION: 815 PASLER ST LOC ID: 131194
REQUESTOR: W R TUBBS CONSTRUCTION ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 05/03/07 SCHED COMPLETION: 05/03/07
********************************************************************************
JOB ORDER RESULT COMMT TrS
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
Owner . . . . . . . . .
Contractor . . .
Application number
Description of Work
Construction type . . .
Occupancy type . . . .
Flood Zone . . . . . .
Approved .
8/17/07
496500-0001-0110
815 PASLER ST
COLLEGE STATION TX 77840
PASLER
PASLER, BLOCK 1, LOT 11 THRU 1
4
SINGLE FAMILY RESIDENTIAL
JAFFAR, SHABEER
W R TUBBS CONSTRUCTION
979 412-0674
07-00001355 000 000
RESIDENTIAL, 1 UNIT DETACHED NEW
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
BuMding Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
6n'T�T
LEFT SIDE ELEVATION RIG14T SIDE ELEVATION REAR ELEVATION
SCALE: VC-l' SCALE v4'1' SCALE: 1W.1'
FLOOR PLAN
SCAN- 1W=1'
I
I
FOUNDATION PLAN
SCALE:
JOTS_ T AND RAFTER SPAN'TABLE
C00W.
AND
FLOOR .]0I3T5
RAFTERS
SR✓:
A4iW.
20, PSF
30 P3
W POF
W PSF
O PSF
W P8F
l240 V
I ljGO
/340 C
/-%0 V
I/W D
RICO D
tr 0C.
/a'i'
IF-y'
10'-T
T-A'
W-e
W-Y
24, 6
kl
T-a'
N-F'
11-r
-Y
Le OC.
$F-e
%'-T'
A-T
le-,e
2T-e
L1Y-0
M
IC OL,
LTA'
Lr2'
2'-W
f'-3F
W-W
IP.'r
2? O'L
W-Y
Q'.-s
9'4
.W-w
0,4,
IF 6
aE'
W-W
W-kt
W-ee
2W-e
2r-O'
24&
0 PC.
20'-Y
r'-D`
W,*
2d-e
r*-Y
24' O,C.
YT'4
W-W
0'-2'
M14.
IS'-r
n': 4C,
tk-2'
R,'-Y
w-v
tv PC,
'21-;!
W-W
r,41'
I
W O
.IT-;t' I
H"- e
k$PANS. IQiE ALA RFFVl FOR VSC M COVE $B6,Lf1Jr
W2R6 t
r ff wnNT. OOCS NOT MOM4Z MI FOR-Ar
txTLtIPF� P�i10D D* iMC
iDACauG COMSTLOI& APf H'b'� M FS' Hx1rLOG PE11 SWARS R.V`-}.
� DEAF LOStD AFA T1K �'FM 1,6LECTfOI TILE G1Ylr 4vR IdO� A O
SPAr54fC b"W ON TLC IfSE DP 15- OR arrr .
6ED' EOIIILCDS CF'SLA71T'lOR AVAtASEdT'( CF"LUlUL ?i ��
GFAT(2Y THAN 704. '
HEADlER SPANS (DOUBLE 2XYMr i/rPLYWDOD BPA[Q
51Z
n4le
I PAN
2 X 4
70 3`-f1'
2 X V
TO Y
2 X ;
1 TO G-O`
1 2 X 12
TO L.F -0
2 X e
1 TO e'-(r
I GENERAL NOTES (unr m OnOWSE &M' W m1, I
O ALL RW3-45 NT'"'A'-0' OF DRERIOR DOOR "TALL EE HAOE
or TETFERL',7GLA56"
m PCO25 %iALL w s',Y IN "EjQn fAxims mtferaamL 5mclPw<0.
a RCA0613 ON FIt3T Kam C2 &'TTi'} JIALL N ztr..
m TEQtvMCAL OR NATLRAL vuwrnATI is tEL11IRED AT ALL
a4TWOOM AM t l-" R0011k
05 NAU.5,M0 GE&L M W&L BE GTP&Wl BDtRP.
CE ,QW*1-r &HALL 0C A ev!iR',R1 OP T-4' Aa3YC AY^ ROW Lt*
EHTKN A IO'O' RAC.^
07 6EOr10OM NLNOOH"A AJLALL fe A tMX-%A-. Ar V-P' N}WR
F&/154'W FLOOR, A HMM" OF 70 W," y I'-W )," AND
NAW A fH-T 5011AR£ FWr WETCAMAR
&& MFMhb R TERIAL 5NALL DE n TV. Cw-pxle (KD. 4') OR
MTTEC.
OR. maFABRKATED FGtt FTKES *.41 w ILL, AND ,ZAA
APPRWED AND A COFT OF T MAN.FALTvRE5 w5TAuAT!]N
MMCLAL SLMLL F1k AVAHLAMV. A: T)f CLN15TFOX71 F1 WTE
AS WWM FOR llZMCTiOL.
U famr FLOOR CEILLVG YYsts SIALL a. dLS— ON 20 R7Urti5
PW SOLWM FOOT (P.&.F.) LAVE LOAD AM D POI--75 PER
bdXJARE FOOT CP.3,P) PeAD WAD Wk 4 WE' 31hPOFI*
A 6E2'l+D FLOOR PARTTTECm 14 SUCAi A "m '"AST FLCLR.
mewl A0,576 5"-L to BAsm ON A 4 ATIMYS TER 5OLIARE
1. FOOT {PR) LW LOAD AND A 10 PO(&.DS FOR MAW KKK
1 P,) DEAD LOAD IF T`f LK.OLD '.,OR PAATDT-PK 1%
R"W.. PUIPMDOC.Al TO TW CER_ACTICN OF T121R SPAN
OR W rOU10' PER bolixRE FOOT (P5.F.Y AM 13 POLM5
PLR SWAkF SOOT CPAi,) V -'TM &E441ND F-OCK r'AILTITIOL
4 RLW" PARA41 a TO THE RRDC7WO OF TWM SPAN.
tl 5EL *) FIQ'R Cp.NG .OdFS 7FJv1 LE BARED Or W FOL*03
"ER &WARE FOOT (►A.I) UV_- L04D-AND,".J PC4V m PEEL
DOLiARE Fe.T.T CP.a.F.} DEAD LOAD:.PRDVi= fRL 04 A+
MVSPAM ON ALL-ViSTTv AW RAFTVR5. -
I] A{ T= OMA L HAVC A rW U t TSRA DTRFKL— OF s&
caPS DER 90VARyi a1CN (e'3.R).
13 A MP4iaA1 OF 2-2-S 5RALL BE PR?,".OW FOR VERTICAL
3VPPORT UeDER P [NO OF ALL SIPLIMOtAL BIW" AND
'HRAIX'RS I04M -NAM S -tY,
Y IF VS WT NATw NEATER m TO BE USED AND IS NOT IN
ATTIC THM TLLF NOT NATER "NFATER %%ALL 1W R -ACW OM
A PEDESTAL 1'-S' ABOVE FlftL%'E'0 FLC
b :F PAS H]T AkTER NFATM Al LOCATED M A.TTIO T-M'THO
'L"T N<TIR WATIm sio— w MACI! Aa )E A 10-0 BtA -4
f'-K M W" O: A FAti, Wt UDE WE Kr MAIN LINE TO
Offux OF +ou-,F,
4 PW C4%)E41IOFG AND DATTOR DAGXLP REOARW FOR
W ME DETECTORS.
rT VENT ALL WAft* FA45 TO THE WT91PB_
0 OUTLETS NT" A 4'-0' RADW OF A MATLTT 50"RCE 'S44"
BE CAtD114'P FAMT WERRUPT C;U.I 3.
14 PQOV M- uO47 FIX`iRE AND & lk CE3'CTM AT EA04
WT i:ATER YFAT61 AND AIR CCNpT"4W, -b— L—TI
ATT+O.
20 •RONDE ELiCTRIC n4KCACY"T AT F Am CO4Dr10 w.
Mr.
AREA
TOTAL HEATED 1,373 S.F-
SLAB 1,379 S-F-
f L2' OG�N
a
CL,1 C
.rs!-�JcT
f.ps
TYPICAL EXTERIOR SECTION
WK ROWS SCALE; 1fZ =' 1'
)r, O.C,± c
2 !v TOP AND
TYPICAL.INTERIOR SECTION
M1N. RQMM SCALE:-li7 =1"'
TIML W fi r•1 Y �rYMr M[s.�lls i rrMMf If V M 1rrY�R b1 YMM/1S
arirrrwr�,Mderfrw,r�TAM rrir,.�r.l Plrr w..w...Farwrk rr
rlrMrsrar rMlrm]IrrsAlMrwA•i rpOrxAraretrrP.r�r Me]eierl
GLMM,L R. rww wr.rwlrs b mme 6-.ir]wMMa
1 Ttrh.lAetll,arrf.+tf+Y.]MTr.%rY.lrr,errrrr,etrrAr,fper,re
POYIWi1011
t"FftlRla+,iwiwelwt Wrrr r freYeeYa.PiRnwirti�ll.trATfreiliTrt
,r.r 1rrl�t/ I I I I ." Lriw J, 1r.EY -
r9�•extlfYlCtrrrrYRF1L
Mr�MMM.4rtM/w,IrtlMrrrMrNY.�.�.rr iiiilw 1A{r4Mo dS�iMnswr
.r1eMrlfYeferlsr wMIeU r.Nr i1I.E fi YFrrr1MAASrQrBMrrlrr
R� IwYr.%.If.rITR.FrfflYMbiePreeNHd lw Ir.1.L�MIwI1Y.& /..e b
.sri.e erw b..r IRwn�1. Lxlpr. rr r rtr M r Yf. r N.nr y M,etlH
arF a �.id re.w.w,r 41wr.e r.M. ryYq'i wKir� rb.�i. deq a
SRe1 trr11 rM r M1! ]Y w O.f rAF
L /fl]AAwMA'fwWAw'.w4.,M1'rA. FT.LMa.MMt.. wawarwl+t*Fw.lib
rYNtrf \ MOIItriHIW eurellrM erxM MlM frrrelyerr SFLR RL IrM.F
a.rrtawF•M+1M!!+Nw IPedM eay,roL - ..
CASTN RAR49eOETE
L Atww.M w,Err]w Mwrri.eF MF b EIFNFC bi. HtgdPwwtMFl►,ErP.d4w.
R
A.
.L,AIW, MIM!►rirrw,Hww'r 6.r w.4r►,ra1Ms, aw.A.Awrw..aF�r1
OYefIwlglrr r
L}r.uwltRl. s
ad.wwrer t5
w:eWe al,
SRAN.rrlir. rrrwe Miw T. wwi* ON raFStRrwr
2. ck"'
• OM, L\Lw.rs: L7iE^.!irbw4a.wY.�wljFurAai,ll4AtMOYP
.rltrrr[Iw(r IAr..we)fblVdflrE ]rMe: QrW o..r,r. rrrnYtrwr.yR,lp
.+dwewl w.Ma.rbr•tttaV bl,r wPtnf44.]d.rrr.rw+a•4M.rM,.r
Yrt rSYtr.rFYr.OFFM np/rrnrIARM O.tA.1WbRYlrr M.vh
te.�frYyAA.a�w4K►lwY..
E AlwMwrErnriwllr rtaM rwaaE/..werw w�4.4rAYMMNHLa.d.a0.
rrN bIRrM Mrlq Frtr{ MA.Ra., reMN)PIIrM QW aLper.rl.rrlr
F!rV.Arer /O.YCI4 WIi/,i. Wpi,r trFMn►AtIrAYL N.A4drpi.t4
tr r.rrr a. r u1r w niwr rw w per.
}- LyMyw/MewMwlslA..L�a l..s Mlw.wMHs.uIFsrFWrSI.nMOF.sre
AD stsa<aw nwe rn..w wewwa,r t.. SE rFswlwa.,.�tAnrlrxr.K a
M.Aer."w I:+rLf.F r.++nw. rTPF,A.Frry..FF+...A..rM
], IrMilflF..Tg11rwM1FEMrr'KMMIINMWYII&Y[Y fi K4rrrrf.
>lelRtlFr dRLt
,, A.wrrt.a.erwrw,.ar rreww]-s,za,zr. m..tr ltmwnMbmer
.awe MIe yeenH M
" rwrwe.w..na .awrM„
!. NrHAa r.ewrlwp MwIRIF.dm *4MrRO wAat
f Afwrar.ewerW rlrwrrrrrl
Peal. wwwgh.aMwr.lFw�FM EF NrHh.d MII.r.1 P",MP.A431N0
M,q. MFrtrMF.rryrwra N sl roerrr erlrr tTA„.nerU.,tr Mls'rII
•eaR w,Iw.e4wk r.+, rl.RsiJ r.VWP,I,ierr.�.vris
l NE1fL
• Aetrb+.r.i lrwt4�Y.ep.piw..twAT, r..r Mlrewcwl�nrw+
.W1.rYwrw9frr/ frwW W. re r rrr Mrrrr.r.
N.wwrr.rrr w+rrw�r..wAola►]Ln+ad.TT.ti
rIM1[,Ilre ree[MeyeYerewi.YA
tL ttiwgrip L.rF..tr14. P,wry, i4rrIP4 bYFiw Mrtlw.p Far. �..�
.Md.iq,awafrwrw�F i , .lrrn r... aa.�"aA H.+:4Me ratepwstaa
tMreYb rM rMa.D
Amber Carter - Re: Calling for C.O. @ 815 Pasler St. Page 1
From: Joe Garcia
To: Amber Carter; Benjamin McCarty; Chris Haver; ...
Date: 8/13/2007 8:29 am
Subject: Re: Calling for C.O. @ 815 Pasler St.
THIS ONE IS OK. JMG
>>> Gina Southerland 08/10/07 12:04 PM >>>
BP# 07-1355
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.cstx.gov
_s BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 07-00001355 Date 5/03/07
Application pin number
. . . 204600
Property Address . .
. . . . 815 PASLER ST
Property ID:
496500-0001-0110
R #:
R37219
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . PASLER
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 90618
Owner
Contractor
------------------------
JAFFAR, SHABEER
------------------------
W R TUBBS CONSTRUCTION
PO BOX 3135
P.O. BOX 11072
COLLEGE STATION
TX 778413135 COLLEGE STATION TX 77842
(979) 412-0674
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
TYPE OF GARAGE (ATT/DET) NA
HEATED AREA 1373.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 348.00
----------------------------------------------------------------------------
Permit
BUILDING PERMIT
Additional desc
GS
Permit pin number
500033
Permit Fee . . . .
424.00 Plan Check Fee .00
Issue Date . . . .
5/03/07 Valuation . . . . 90618
Expiration Date . .
10/30/07
Qty Unit Charge
Per Extension
BASE FEE 260.00
41.00 4.0000
THOU BLDG, VAL 50001-100000 164.00
----------------------------------------------------------------------------
Special Notes and Comments
Narrow Wall Bracing
Fully Sheathed with Fiberbrace.
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY ARC -FAULT CIRCUIT
--------------------------------------------
BUILDING DE%PT REPRESENTATIVE:
----� -----------
APPLICANT:` -
i
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 07-00001355 Date 5/03/07
Application pin number . . . 204600
----------------------------------------------------------------------------
Special Notes and Comments
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAUNLING PPATTERN,
--------------------------------��J•-- `-----------
BUILDING DEPTREPRESENTATIVE:
n
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00001355 Date 5/03/07
Application pin number . . . 204600
----------------------------------------------------------------------------
Special Notes and Comments
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROON AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIAT VICINI OF THa/G'/L�
------------------------------------------- - ---------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: e" E' 9 rt
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number . . . . . 07-00001355 Date
5/03/07
Application pin number . . . 204600
----------------------------------------------------------------------------
Special Notes and Comments
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited
----------------------------------------
Due
-----------------
Permit Fee Total 424.00 424.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1174.00 1174.00 .00
.00
10-
-------------------------------------------- -A - ------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
07-00001356 Date
5/03/07
Application pin number . . .
305120
Property Address . . . . . .
815 PASLER ST
Property ID:
496500-0001-0110
R #:
R37219
Application type description
TEMP POLE
Subdivision Name . . . . . .
PASLER
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
JAFFAR, SHABEER
------------------------
W R TUBBS CONSTRUCTION
PO BOX 3135
P.O. BOX 11072
COLLEGE STATION TX 778413135
COLLEGE STATION TX
77842
(979) 412-0674
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . GS
Permit pin number . 500157
Permit Fee . . . . 20.00
Issue Date . . . . 5/03/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT 45.00
----------------------------------------------------------------------------
Fee summary Charged
---------------------------
Paid Credited Due
------------------------------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
-------------------------- ----- --- -------------
BUILDING DEPT REPRESENTATIVE:APPLICANT:
APPLICANT: 1,,,D
r 'Ti
r For Offl- U- Ody
APPLICATION FOR BUILDING PERMIT DATE 111 DIRCC REG
CITY OF COLLEGE STATION
n 1101 COLLEGE APPLICATION #
STATION, TX 77840
TEMP POLE #
CITY 01: COLLFGF. STATInV (979) 764-3570 (979) 764-3496 FAX
PL n i�,r d-/%nr%Pmrnr 8m rr
W W W.CSTX.GOV
ADIRESS/LQCbTION: P _L K/t-_ �'
LOT lt' 12--FLOCK SUBDIVISION-Z�PASLJQAC PPJM*lSSEC/PH_
BUSINESS/OWNER NAME:
PHONE:
CONTRACTOR/HOMEOWNER: l.-�Z�-r�35 C�o�scr� . -G•c PHONE:
CONTRACTOR ADDRESS: P- o . P o.& 11,022, G•(�c .+• -�., T'C� '7-18 x -1-
ELECTRICIAN: LJrp--- IC F•�errs-sx— PLUMBER: P G • P L- - =-'�.
HVAC: Dx--L Ct,-ev_-�PTS- GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
��
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION* SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK:
STRUCTURE USE: �-�r-=W_—
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: _
TEXAS ACCESSIBILITY STAND RD ) PROJECT REGISTRATION# EABPRJ
VALUATION: $ - �
TOTAL AREA: LI- 7�
HEATED AREA:
_�
(Cost of Labor and Materials)
dPUBLIC SEWER
NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM
NUMBER OF BATHROOMS:
2
SEWER TAP: 4 r1
ERrt„r
INTERIOR WALL TYPE:
% o a a
SIZE
WATER TAP: 3 1, r"
EXTERIOR WALL TYPE:
SzE
OTHER TAP:
FOUNDATION TYPE:
5�43
SIZE
TEMP POLE
ROOF TYPE:
GARAGE TYPE: SINGLE F__1
DOUBLE F__1 TRIPLE
ATTACHED F_�
DETACHED F_� CARPORT
SIGNATURE OF APPLICANT: ( (-
*If proposed work involves new commercial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
S-,� - o 7----
Plans Examiner
�� S 6j_&ej (j/ r rb an d,e
Zoning Official
wwwrients:
E rNO
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
0
(3 -,*'
I,
_«
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# O S s
DATE: 2_ 7
O
BUILDING ADDRESS:
I. Foundation Requirements- Minimum City Foundation Standards
NNW
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
K
II. Framing:
Floor, Wall, Ceiling and Roof Requirements
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
WVOK
E.
Header sizes indicated on plans
NA/OM
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within T of property line to have protected openings.
III. Stairway Requirements
OK
ffK
A. Stairway Details
OK
1.
Maximum riser height 7-3/4 inches
2.
Minimum tread width 10 inches
3.
Stairway risers are uniform 3/8" Max. difference
4.
Stairway width not less than 36 inches
5.
Stairway headroom not less that six ft. eight 6-8
B. Winder details
1.
Treads a minimum of six 6 inches on narrow edge
2.
Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1.
Riser height less than nine and one-half 9-1/2 inches
2.
Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3.
Stairway width not less than thirty-six inches
4.
Headroom required not less than six ft six 6-6 inches
5.
All treads must be identical
D. Guards/handrail details
1.
Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2.
Handrails are required on stairways located two or more risers above floor/grade
3.
Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4.
Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5.
Guards must be a minimum of thirty-six 36 inches above finished floor
6.
Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
NA/ K
A. Hearth extensions
1.
Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2.
Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry
fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
Electrical plan to include:
N
ATA.
1.
Electrical fixtures & switches indicated
2.
Smoke detector locations indicated as required
3.
GFI circuits indicated where required
4.
Arc fault protection for bedroom circuits
5.
Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N K
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NAB
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
K
"APPROVED PLANS PER IRC SECTION R106.3.1."
ANS EXAMINER DATE
tA%
rt-z
r-
MECcheck Compliance Report
2000 IECC
MECcheck Software Version 3.2 Release lb
TITLE: Pasler
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 04/27/07
DATE OF PLANS: 04/27/07
PROJECT INFORMATION:
815 Pasler
COMPANY INFORMATION:
W.R. Tubbs Construction, Inc.
COMPLIANCE: Passes
Maximum UA = 520
Your Home = 320
38.5% Better Than Code
Ceiling 1: Cathedral Ceiling (no attic)
Ceiling 2: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame, Double Pane with Low-E
Door 1: Solid
Door 2: Glass
Slab 1: Unheated, 0.0' insul.
Furnace 1: Forced Hot Air, 78 AFUE
Air Conditioner 1: Electric Central Air, 14 SEER
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter R-Value R-Value
U-Factor
UA
98
1
0.0
7
831
:0
0.0
29
1254
13.0
0.0
88
139
0.065
9
20
0.440
9
18
0.650
12
159
0.0
166
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been
designed to meet the 2000 IECC requirements in MECcheck Version 3.2 Release lb.
Builder/Designer Date jy-q�'
MECcheck Inspection Checklist
2000 IECC
MECcheck Software Version 3.2 Release lb
DATE: 04/27/07 -
TITLE: Paster
Bldg.
Dept.
Use
Ceilings:
[ ] I 1. Ceiling 1: Cathedral Ceiling (no attic), R-14.0 cavity insulation
Comments:
[ ] I 2. Ceiling 2: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
I
Above -Grade Walls:
[ ] I 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
I
Windows:
[ ] I 1. Window 1: Metal Frame, Double Pane with Low-E, U-factor: 0.065
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
I
Doors:
[ ] I 1. Door 1: Solid, U-factor: 0.440
Comments:
[ ] 2. Door 2: Glass, U-factor: 0.650
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
I
Slab -On -Grade Floors:
[ ] I 1. Slab 1: Unheated, R-0 (uninsulated)
Comments:
I
Heating and Cooling Equipment:
[ ] I 1. Furnace 1: Forced Hot Air, 78 AFUE or higher
Make and Model Number
[ ] I 2. Air Conditioner 1: Electric Central Air, 14 SEER or higher
Make and Model Number
[ J The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
I
Air Leakage:
[ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate
air -tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation.
I
., _ I A
Materials Identification:
[ ] Materials and equipment must be installed in accordint to the manufacturer's installation instructions.
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R-values, glazing U-values, and cooling equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
[' ] Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
[ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at
less than 2 in. w.g. (500 Pa).
[ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] Air filters are required in the return air system.
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in
Inches by Pipe
Sizes
Heated Water
Non -Circulating Runouts
Circulating
Mains and Runouts
Temperature (F)
Up to 1"
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
00
�/
SCALE: 1 " = 30' / 6 /
LEGEND:
-0- UTILITY POLE
AERIAL ELECTRIC LINES
CONCRETE
SURVEYORS CERTIFICATE:
I, BRAD KERR, R.P.L.S. NO. 4502. DO HEREBY CERTIFY THAT ,TO THE BEST OF MY KNOWLEDGE THIS
5/8 INCH IRON PLAT IS A TRUE REPRESENTATION OF A SURVEY MADE ON THE GROUND UNDER MY SUPERVISION AND
ROD SET THAT THERE ARE NO VISIBLE ENCROACHMENTS ON THIS TRACT EXCEPT AS SHOWN HEREON.
THIS TRACT DOES NOT LIE WITHIN A DESIGNATED 100 YEAR FLOOD PLAIN ACCORDING TO
/ THE F.I.R.M. MAPS, COMMUNITY PANEL NO. 48041COl42 C, EFFECTIVE DATE: 07-02-1992.
�h
ORVA L. RUCKER �� k
N
/ CALLED LOTS 15 & 16 , \
/ 6159/109
).
BRAD KERR
REGISTERED PROFESSIONAL
LAND SURVEYOR NO. 4502
38.79 /43
/ \F `�/ 5/8 INCH IRON
\ / / / p< / ROD SET
5/8 INCH IRON
ROD SET —
SEE METES AND BOUNDS PREPARED JUNE,
2006. FOR MORE DESCRIPTIVE INFORMATION
BUILDING SETBACK LINES PER CITY OF
COLLEGE STATION U.D.O.
BLANKET EASEMENT TO CITY OF BRYAN,
98/219, DOES APPLY TO THIS TRACT.
CM - CONTROLLING MONUMENT FOUND AND
USED TO ESTABLISH PROPERTY LINES.
BEARING SYSTEM SHOWN HEREON IS BASED ON
GRID NORTH AS ESTABLISHED FROM CPS
OBSERVATION.
/ \ /
0.26 ACRE TRACT
sob
TIT Rr
GRAVEL / \fit PyOG00
15.44
�L OLD 4:GAS
g�) METERa
ou,,
OUT Gj / A. G SEARCY AND WIFE,
CORNEUUS WATSON SEARCY
S> )000 CALLED Lors s & 10
F 842/42 /
o • / /
/ 5/8 INCH IRON /
ROD SET /
s POINT OF /
*e. BEGINNING/
74• /
WATER e
METER 30 MAC NAIL FOUND
00, IN TIMBER
0 ao l
� co °ca eeeeeec ee �eccc cc�eu
6 R A D =RR
,oee �eesueaeeacfci,aereoee
f
�"3 45,021
'7 °ee fa °`'!' �,��'
uI
I
I
i
I
i
REVISED 07-13-06: INFORMATION IN TITLE BLOCK
BUYER !
I
SHABEER JAFFAR
TITLE
UNIVERSITY TITLE
COMPANY;
COMPANY
G.F. No.,
62179
i
LAND TITLE SURVEY PLAT
OF A 0.26 ACRE TRACT
PORTION OF LOTS 11, 12, 13, 14 AND 15
JOE PASLER'S PARTIAL SUBDIVISION
VOLUME 91, PAGE 583
COLLEGE STATION, BRAZOS COUNTY, TEXAS
KS
SCALE. 1 INCH = 30 FEET
�f I� SURVEY DATE: 06-21 —06
^1 I� PLAT DATE: 06-30-06
JOB NUMBER: 06-403
CAO NAME: 06-403
CR5 FILE: pasler (cont); 06-403 (job)
PREPARED BY: KERR SURVEYING, LLC
505 CHURCH STREET, P.O. BOX 269
COLLEGE STATION, TEXAS 77841
PHONE (979) 268-3195
' • f ' •• .- _ .. + .r-_. -•... _. rr1—� �_�_��._�.--��---..`....-..w.r r--w - / � �V �.• -ter.._ -. �r.....
a
Hut it is expressly agreed end stipulated that the Vendor's Lien is retained
.. i ;
"Ell again t the above described •property, premises and improvenimts, until the above des-
cribed n +s end all interest thereon .are 1"ully paid according to its .Pave end tenor,
A
effect -and r ding, when this dead shall become absolute. ;
t,. +sitness my d at B yen, Texas, this 2Cth day of August, A.D. 1936.
ls, :: t
$1.00 Revenue Stamp (fixed Isaiah tied aTrrite,
rid duly canoelled. (Isfsiah ?red White individually and'
-.
•„ ;• as sole surviving hoir of T.Wmard Tlhite and
:� ' his wife Sallie B. Wal ite, both deceased. j
COMITY OF BRAZOS 3370RR It". S. Ware, a Ilateryr Public in and for Brazos
,t;,- County, Texans, on this day personal nppea�red Isaiah 'fed White, knovm to me to be the
..•',;, rporson whose name is subscribed to the f egoing instrument, and aelmowledged to me
't 4Tthat ho-:executed the a=6 for ts:s purposes as con- iration therein_ sspreese�d, enc3__
in the capacities therein :Meted. 4
x.,;f Given under try hand and seal of office this 2a day of Auc;ust, A.D.- 1936. 3
1.4 �: A. S. Ware, Rotary blie in and for
;= .� , '
Brazos County, Texas.
The Pore�,oing is a true copy of the original instrument which a filed for record on
.+:
*, `•_Cr{t the .29th day of Aug. A.D. 1936 at 4:15 o'clock p.m. and duly racer d on the 31st day
zs -r of Auk. .i.D. 1936 at 4:15 o'clock pp, to which I certify
' ��• Frank Worsham, C. C. C. B. C.
Depu
. t
_ 660'
ZT03 PASLBR'S PARTIAL , •-�
J SQBDIIUSION OF LOTS TMt AND Lot 7' D. A. with' as
I.'I."V.M? OF D.A. SIZITIi'S ? "• Subdivisions,
SUBDIVISION OF 96 A07a TRACT
n; *UMIARD CARTIM 12SAGU3 +—�
4 III BRAZOS COUNTY, T U S f 4a�
414 J
!.._ Lot e D. A. Smit h* s ,
Map of D. A. Smith's Sub- � r Subdivision � Lot 13, D.A.Smith co�
division is recorded in Subdivision, #
¢� Voiuxie 49, page 106, - - - - -- - -- - _ - — - 4
records of Heeds of
.,,,,..records
County,,, Texas.
;�• _ Lot 9 D. A. Smith a +� Lot 12, D.A.Smithi
t subdivision Subdivision.
Lot 10 D. ii. Smith, Aubd , t Lot 11 D.X.S. Subd.
i
t I-
A�..-•
tt ..•S t �' ,I '
�m"•;��TB STAT3 OF T .LS4 -
-COMITY OF BRAMS I, Joe Pasler, of . Brazoe County, Te=s, hereby designate the ebove 4,
r and foregoing.map as the snap of a partial subdivision of lots numbers ten, (10) and eleven (11)
or D. A. SmIthla Subdivision of a 96 acre tract of land In the Richard Carter•league, in•
3: Brazos County, Texas, as shown by the map of. said subdivision recorded in V61ume 49, page 1069
. -.• S
records of deeds of 'Brazos County, Tcxaa, and I hereby dedicate the astr��t designated on ��
/ t
".' Said map as Puler Street to the use of the public.
4% +3 ' Witnesa my hand at Bryan, Texas, tAis the 29th day of August, A.D. 1936.
a - Toe raslor
tr TMSTATN OF TMA3Q
CDiITY OF BR=S $' Oiii I-%, T. G. Uinkert, a I:otary Fublio in and for trazoo County,
-IW.ar�.tvu 2+..:•vi.,L.l1 +n ,.�.e ,SL..... +........... r_, -� a-. ... � -.r v... .. +.w .u.. n.. .�-.,. .-a.a ...r _. -a ,. •-, s . ..I.w__{.=
..�._ J.r - - - .-. __ - ...». .«..... ...•P I"'7,."Jr, � -,. _ 'may—.•-.•�,....... �'-' i111.II�l�wllw.r
I