HomeMy WebLinkAboutRES2007-01352 410 ROCK SPRING CT BUILDING PERMIT010
�t��ru c��ie rJ
PREPARED
1/10/08, 8:07:34
INSPECTION TICKET
PAGE 2
City of
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 1/09/08
------------------------------------------------------------------------------------------------
ADDRESS
. : 410 ROCK SPRING CT
SUBDIV: SPRING MEADOWS
PH 2
'TENANT,
NBR: PATIO HOME
!CONTRACTOR T-2 PROPERTIES, INC. PHONE (979) 846-8845
OWNER
T-2 PROPERTIES INC
PHONE
PARCEL
582830-0203-0330
APPL NUMBER: 07-00001352 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
5/23/07 RH
BLDG, FOUNDATION -SLAB TIME: 17:00
5/23/07 AP
May 23, 2007 8:44:42 AM malford.
05/23/2007 03:38 PM RH PDA
Strings up, slab ground installed.
B115 01
7/09/07 JGM
BLDG, FRAMING TIME: 17:00
7/09/07 AE
July 9, 2007 9:33:13 AM acarter.
07/09/2007 04:09 PM JGM PDA
need to sheetrock over fireplace
B13Q O1
7/13/07 JGM
BLDG, INSULATION TIME: 17:00
7/13/07 AP
July 13, 2007 8:21:13 AM kwolfe.
B125 01
1/09/08 BI
BLDG, FINAL TIME: 17:00
January 9, 2008 1:-18:_48-PM_acarter,. -
—
(key to front door-is.above,back porch door.
-------------------------------------- COMMENTS AND NOTES --------------------------------------
�- 1" f p'l
Date: 1/10/2008
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1352
Address: 410 ROCK SPRING CT
Type
Inspection Type Code
Description
status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
05/23/2007 03:38 PM RH PDA
B100
BLDG, FOUNDATION -SLAB
IC
Strings up, slab ground installed.
B115
BLDG, FRAMING
IC
07/09/2007 04:09 PM JGM PDA
13115
BLDG, FRAMING
IC
need to sheetrock over fireplace
E150
ELEC, FINAL
IC
10/19/2007 03:58 PM RH PDA
E150
ELEC, FINAL
IC
By building final all plugs in garage shall be GFI. If for
E150
ELEC, FINAL
IC
freezer make plug single outlet. All plugs in laundry room
E150
ELEC, FINAL
IC
shall be GFI , except washer and dryer plugs.
Page 1
t on
V,
-
.ubf'ATION: 410 ROCK SPRING CT -9 -7-,ty
RFQ`-JESTOR: T-2- PROPERTIES. INr-' ORIGIN: CljsT6ml�x- WA�,wc, na
REQ USER: NCOCHPAN AUTH 'USER: NCOCHRAN W--,-K- TYPE
411 SWP'TAP 3/,,4 Nlrl'kR T'A-P
iA
--
ExI--- FB---
--- ---- --
PL 60.0' N 41 51' 48'
ELEC.
i
�1-I x-R. �\
IO' PUE AND
w
j �•.`
DRAINAGE
I
\
EASEMENT
W;I
�-
I
I
o
"I
II
II
`U/G ELEC.
�
�iI
---
fit------ --
—'— ---------
]O MG LME LD
-----
; I
------------------'t—
I
\ O/O FOUNDATION
I
O i
4
-3 BAR *12'0.C.
u . NI PEtlo. 4
k.
i
PATIO:'
j .erviu
_1J
%I
= fl
-
10' ROOF
O Y
OVERHANG
~0.
[ TYP.
o O
V
O
LOT 33
BLK 3
2 r,�• 64 5F. -
OTAL AR
LOT 34
SINGLE STORY
ZERO LOT L
PATI
LL
GAS
�
-
ETEf2
BED
.t_I PICA
st
_
I
taros
- O
ea� �
/1
-------- ---- --
I W
ING LI I
I
I
- - -A
-
f
j
I
.'
V2 ° CONIC.arrR 1
WE
X
PLAN
=tlTR
b
3 BAR t1YO.G.
SCALE
: I"• 20'
-
r
:.
- ------------------
-------------------
NOTE : UTILITY SERVICE LINE !-OCATIONS
j
-
ARE APPROxMATE -FlELD VERIFY
I
eRlac rulL6ox
ROCK SPRING COURT
i?
0
z
Q
s
r
p�
2
C WOW)
Z
iz
Q � `
Q
Z
O
O O
rt1 LOT 32
r
a
d)
uj
Q
Wlu-JQ
dw
0- Z W I-
� u r 0
0
W }
u �
Re
m v id .
tt1 � N
`r1UNZ
Ozo�
W N Ul N
wuzw
Da
W ik J
aato13
Z
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 07-00001352 Date 5/02/07
Application pin number . . . 370520
Property Address . .
. . . . 410 ROCK SPRING CT
Property ID:
582830-0203-0330
R #:
R116915
Tenant nbr, name . .
. . . . PATIO HOME
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . SPRING MEADOWS PH 2
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 146000
Owner
Contractor
------------------------
T-2 PROPERTIES INC
------------------------
T-2 PROPERTIES, INC.
1700 BARAK LN
DBA CLASSIC HOMES
BRYAN
TX 778023311 1700 BARAK LANE
BRYAN TX 77802
(979) 846-8845
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1934.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 410.00
----------------------------------------------------------------------------
Permit
BUILDING PERMIT
Additional desc
MA
Permit pin number
499814
Permit Fee . . . .
598.00 Plan Check Fee .00
Issue Date . . . .
5/02/07 Valuation . . . . 146000
Expiration Date . .
10/29/07
Qty Unit Charge
Per Extension
BASE FEE 460.00
46.00 3.0000
THOU BLDG, VAL 100001-500000 138.00
----------------------------------------------------------------------------
Special Notes and Comments
Narrow
Fullygar
-Wall -Bracing .Sheathedwi-16"nim
-----
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
Application Number . . . . . 07-00001352
Application pin number . . . 370520
Page 2
Date 5/02/07
Special Notes and Comments
Framing.
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS -
ELECTRIC STRI-P HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR
ATTACHED GARAGES SHALL HAVE
PENETRATIONS SEALED
Assure Proper GFI Locations,
Outside A/C Unit
GARAGE DOOR HEADER
ALL TOP PLATE AND HEADER
Including One Within 25' Of
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AN /OR ACCESS MAY;.HA _TO
------------------------------------------ -----•- -----------------
BUILDING DEPT REPR TATIVE:
APPLICANT: 1
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00001352 Date 5/02/07
Application pin number . . . 370520
----------------------------------------------------------------------------
Special Notes and Comments
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
COLLEGE STATION ELECTRICAL DIVISION REQUESTS THAT THE METER
CAN/ELECTRICAL SERVICE DISCONNECT BE LOCATED ON THE
STRUCTURE AS CLOSE AS POSSIBLE TO THE SECONDARY FEEDER
CONDUIT FROM THE TRANSFORMER.
(see site plan for location of conduit or contact
electrical division)
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other -means.
Also assureproperprotection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
------------------------------------- ------ ------ ----------------------
BUILDING
APPLICANT: 1
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00001352
Application pin number . . . 370520
Page 4
Date 5/02/07
Special Notes and Comments
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL- SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
Exterior walls located on property line shall have a one
hour fire resistance rating without openings. Overhangs
extending over the property line shall have a one hour fire
resistant construction on the under side, perforated
venting allowed,and shall extend a maximum of 18". Slab
edge shall be built on property line.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" 350.00
WATER TA 3/4" 400.00
------------------------------------------------�-- --•- --'------------
BUILDING DEPT REPRE
APPLICANT:
BUILDING PERMIT
• CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Page 5
Application
Number . . . . .
07-00001352
Date 5/02/07
Application
pin number . . .
370520
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid
----------
Credited
----------
Due
----------
-----------------
Permit Fee
Total 598.00
598.00
.00
.00
Plan Check
Total .00
.00
.00
.00
Other Fee Total 750.00
750.00
.00
.00
Grand Total
1348.00
1348.00
.00
.00
-------------------------- --- ..........................
BUILDING DEPT REPRESENTATIVE:
APPLICANT: 1 r
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
07-00001353 Date
5/02/07
Application pin number . . .
452155
Property Address . . . . . .
410 ROCK SPRING CT
Property ID:
582830-0203-0330
R #:
R116915
Application type description
TEMP POLE
Subdivision Name . . . . . .
SPRING MEADOWS PH 2
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
T-2 PROPERTIES INC
------------------------
T-2 PROPERTIES, INC.
1700 BARAK LN
DBA CLASSIC HOMES
BRYAN TX 778023311
1700 BARAK LANE
BRYAN
TX 77802
(979) 846-8845
----------------------------------------------------------------------------
Permit TEMP POLE
PERMIT
Additional desc MA
Permit pin number 499822
Permit Fee . . . . 20.00
Issue Date . . . . 5/02/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary -Charged
---------------------------
Paid Credited
------------------------------
Due
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
-------------------------------------------------�-- - ------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
IN
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE, STATION, �TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STATION.TX.US
ADDRESS/LOCATION: RC�� (� cL�N
e,-
LOT BLOCK / SUBDIVISION �j�\ba
BUSINESS/OWNER NAME: Z �2oPEtL\C1ES — 1_IA�StC
CONTRACTOR/HOMEOWNER: I -1,
CONTRACTOR
ELECTRICIAN:
HVAC:
a
w onteum avy
DATE: ✓ ( , ' Dl �
APPLICATION # ,,U\ll - I L
TEMP POLE # -
PHONE: qL- p�94 (-
PHONE:
GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION
ADDITION VING
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION
DUPLEX (Landscape Plans Req) `` RE\MODEURE OVATION
DESCRIPTION OF WORK: 5v ct Wv1K- S�Tr— C1,64 c -
STRUCTURE USE:
RE -ROOF (Total/Partial)
SHELL ONLY
SLAB ONLY
SWIMMING POOL
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) F OJECT REGISTRATION# EABPRJ
VALUATION: $ 14(,.oQo od v TOTAL AREA: 7.� 6HEATED AREA:
(Cost of Labor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
"�SER TAP: I,
WATER TAP:Z (I -
SIZE
OTH TAP:
TEMP POLE
/d°j
`� • GARAGE TYPE:
1
SIGNATURE OF APPLICANT:
SIZE
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
SINGLE a OUBLE � TRIPLE
ATTACHED El
CARPORT
Nc
U&JMs �� -sWET a�
BIiL .- \wt �t�v�w•G —sViT Rrx-fit_
CAW(. �'� OW F, c1,Y�aptr
F]
a
�f Official Use Only Comments:
rNO—
------------- - - --- ----------- ----- — ---- ------ - --
Plans Examiner - Zoning Official
Lof Coot, w c4iov
�6 w j N
luny sU." V1,464 C.
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating
K of\,
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# Oq ` / 3 sa-
DATE:
BUILDING ADDRESS:
v
I. Foundation Requirements- Minimum City Foundation Sta dards
NAIIVJ
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
OUOK
II. Framing:
Floor, Wall, Ceiling and Roof Requirements
NA/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
K
1. One -hour rated extending to roof deck
K
E.
Header sizes indicated on plans
NA/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
NA/QW
NA/
A. Stairway Details
OK
1.
Maximum riser height 7-3/4 inches
2.
Minimum tread width 10 inches
3.
Stairway risers are uniform 3/8" Max. difference
4.
Stairway width not less than 36 inches
5.
Stairway headroom not less that six ft. eight 6-8
B. Winder details
1.
Treads a minimum of six 6 inches on narrow edge
2.
Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1.
Riser height less than nine and one-half 9-1/2 inches
2.
Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3.
Stairway width not less than thirty-six inches
4.
Headroom required not less than six ft six 6-6 inches
5.
All treads must be identical
D. Guards/handrail details
1.
Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2.
Handrails are required on stairways located two or more risers above floor/grade
3.
Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4.
Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5.
Guards must be a minimum of thirty-six 36 inches above finished floor
6.
Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N
A. Hearth extensions
1.
Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2.
Fireplace opening ? 6 s . ft. extensions: 12" side & 20" forward
B. Masonry
fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/
1.
Electrical fixtures & switches indicated
2.
Smoke detector locations indicated as required
3.
GFI circuits indicated where required
4.
Arc fault protection for bedroom circuits
5.
Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
—9OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
P A S EXAMINER
DATE
Permit Number
REScheck Compliance Certificate Checked By/Date
1995 MEC
REScheck Software Version 3.5 Release Id
Data filename: C:\Program Files\Check\REScheck\SPRING MEADOW -LOT 33.rck
PROJECT TITLE: NEW SINGLE FAMILY RESIDENCE- 410 Rock Spring Court
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 04/18/07
DATE OF PLANS: 4-01-07
PROJECT DESCRIPTION:
LOT 33 BLK 3
SPRING MEADOWS SUBDIVISION
COLLEGE STATION, TX.
DESIGNER/CONTRACTOR:
T-2 PROPERTIES INC, D.B.A.- CLASSIC HOMES
PROJECT NOTES:
ZERO LOT LINE PATIO HOME
COMPLIANCE: Passes
Maximum UA = 736
Your Home UA = 533
27.6% Better Than Code (UA
Gross
Glazing
Area or
Cavity
Cont. or Door
Perimeter
R-Value
R-Value U-Factor
UA
Ceiling 1: Flat Ceiling or Scissor Truss
1782
30.0
0.0
62
Ceiling 2: Cathedral Ceiling (no attic)
84
19.0
0.0
4
Ceiling 3: Cathedral Ceiling (no attic)
68
19.0
0.0
4
Ceiling 4: Flat Ceiling or Scissor Truss
126
19.0
0.0
6
Wall 1: Wood Frame, 16" o.c. AMC.
90
13.0
0.0
7
Wall 2: Wood Frame, 16" o.c.
1096
13.0
0.0
90
Wall 3: Wood Frame, 16" o.c.
580
13.0
0.0
27
Window 1: Metal Frame, Double Pane with Low-E
30
0.510
15
Window 2: Metal Frame, Double Pane with Low-E
63
0.510
32
WiQow 3: Metal Frame, Double Pane with Low-E
42
0.510
21
'Window 4: Metal Frame, Double Pane with Low-E
16
0.510
8
Window 5: Metal Frame, Double Pane with Low-E
24
0.510
12
Window: transom: Metal Frame, Double Pane with Low-E
15
0.510
8
Window: transom: Wood Frame, Double Pane with Low-E
3
0.510
1
1741r&Vj 6 11' Q Fmn'a Zi:r z.'v a
fo
O'Llo
3
Door: front: Glass
20
0.400 8
Door: porch: Glass
18
0.440 8
Door: garage: Solid
20
0.150 3
Floor 1: Unheated Slab -On -Grade
205
0.0 214
Insulation depth: 0.0'
Furnace 1: Forced Hot Air, 80 AFUE
Air Conditioner 1: Electric Central Air, 13 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 1995 MEC
requirements in RES check Version 3.5 Release Id (formerly MEC chec)4 and to comply with the mandatory requirements listed in
the REScheckInspection Checkjisr ,
Builder/Designer ` , Date Z--t - 10 -07
"Scheck Inspection Checklist
1995 MEC
REScheckSoftware Version 3.5 Release id
DATE: 04/18/07
PROJECT TITLE: NEW SINGLE FAMILY RESIDENCE- 410 Rock Spring Court
Bldg.
Dept.
Use I
Ceilings: ,
I. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation
Comments: at study and kit.
3. Ceiling 3: Cathedral Ceiling (no attic), R-19.0 cavity insulation
Comments: at master bath
4. Ceiling 4: Flat Ceiling or Scissor Truss, R-19.0 cavity insulation
Comments: pony walls facing attic r -
Above -Grade Walls:
1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments: gable walls - avg. 9' h
2. Wall 2: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments: 8' h walls
3. Wall 3: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments: 10' h walls
Windows:
1.
Window 1: Metal Frame, Double Pane with Low-E, U-factor: 0.510
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes (
] Nc
Comments:
2.
Window 2: Metal Frame, Double Pane with Low-E, U-factor: 0.510
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [
] No
Comments:
3.
Window 3: Metal Frame, Double Pane with Low-E, U-factor:
0.510
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ J Yes [
] No
Comments:
4.
Window 4: Metal Frame, Double Pane with Low-E, U-factor:
0.510
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [
] No
Comments:
5.
Window 5: Metal Frame, Double Pane with Low-E, U-factor: 0.510
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [
] No
Comments:
6.
Window: transom: Metal Frame, Double Pane with Low-E, U-factor:
0.510
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [
] No
Comments:
7.
Window: transom: Wood Frame, Double Pane with Low-E, U-factor:
0.510
For windows without labeled U-factors, describe features:
4 D-- Tram. T.—. Tl,o—.l n—P) r 1 V.. r
1 ATn
Comments: rear door transom
8. Window 6: Metal Frame, Double Pane with Low-E, U-factor: 0.510
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [
Comments: front door transom
Doors:
1. Door: front: Glass, U-factor: 0.400
Comments: ENTRY DOOR
2. Door: porch: Glass, U-factor: 0.440
Comments: REAR PORCH DOOR
3. Door: garage: Solid, U-factor: 0.150
Comments: DOOR FROM GARAGE
Floors: .
1. Floor 1: Unheated Slab -On -Grade, R-0 (uninsulated)
Comments. -
Heating and Cooling Equipment:
1. Furnace 1: Forced Hot Air, 80 AFUE or higher
Make and Model Number
2. Air Conditioner 1: Electric Central Air, 13 SEER or higher
Make and Model Number
] No
Air Leakage:
[ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] I Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
1 3" clearance from insulation.
Materials Identification:
[ ] I Materials and equipment must be identified so that compliance can be determined.
[ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] I Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly
marked on the building plans or specifications.
I
Duct Insulation:
[ ] Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
I
Duct Construction:
( ] I All ducts must be sealed with mastic and fibrous backing tape. Pressure -sensitive tape may be used
for fibrous ducts. Duct tape is not permitted.
[ ] I The HVAC system must provide a means for balancing air and water systems.
I
Temperature Controls:
[ ] I Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
I
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
I
Swimming Pools:
[ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
I
Heating and Cooling Piping Insulation:
OF or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
f
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water
Non -Circulating Runouts
Circulating Mains and Runouts
Temperature ( F)
Up to V
Up to 1.25"
1.5" to 2.0" Over 2"
170-180
0.5
1.0
1.5 2.0
140-160
0.5
0.5
1.0 1.5
100-130
0.5
0.5
0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness in Inches by
Pipe Sizes
Piping System Types
Range ( F)
2" Runouts
1" and Less
1.25"
to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)