HomeMy WebLinkAboutDEMO2007-01337 2305 TEXAS AVE S DEMO PERMITDEMOLITION PERMIT
CITY OF COLLEGE STATION
1101 TEXAS ' AVE
COLLEiGE .SjATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00001337 Date 4/27/07
Application pin number . . . 019788
Property Address . . . . . . 2305 TEXAS AVE S
Property ID: 365000-0101-0010
R #: R30326
Tenant nbr, name . . . . . . PAWN SHOP
Application type description DEMOLITION, COMMERCIAL
Subdivision Name . . . . . . K F 0 #1
Property Use . . . . . . . .
Property Zoning . . . . . . . GENERAL COMMERCIAL
Application valuation . . . . 12000
Owner Contractor
------------------------ ------------------------
FIRST NATIONAL BANK OF BRYAN ALBO CONSTRUCTION
PO BOX 833 3888 DILLY SHAW TAP RD
BRYAN TX 778050833 BRYAN TX 77808
(979) 575-9423
--- Structure Information 000 000 DEMO PERMIT FOR PAWN SHOP BUILDING
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . BUSINESS
Other struct info . . . . . TAZ 285.00
----------------------------------------------------------------------------
Permit . . . . . . DEMOLITION PERMIT
Additional desc . . KW
Permit pin number . 498824
Permit Fee . . . . 25.00 Plan Check Fee .00
Issue Date . . . . 4/27/07 Valuation . . . . 12000
Expiration Date . . 10/24/07
Qty Unit Charge Per Extension
BASE FEE 25.00
----------------------------------------------------------------------------
Special Notes and Comments
CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND
7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA)
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 25.00 25.00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 25.00 25.00 .00 .00
------------------------------------------- --- ---------
BUILDING DEPTT REPRESENTTIVE:
APPLICANT: , 1I0 Q 0 /1-- 2�_
DEMOLITION PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLFcGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00001337
Application pin number . . . 019788
Page 2
Date 4/27/07
----------------------------- ---- --_ _ --- - - ---------
BUILDING DEPT REPRESENTATIVE:
n n
APPLICANT:
4For Office Use Only
APPLICATION FOR BUILDING PERMIT DATE 6 ' -ri,;� CC REG
1101 TEXAS AVENUE " APPLICATION # + -
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX TEMP POLE #
CITY OF COLLEGE STATION WWW.CSTX.GOV
planning d Dsvtlopmmt Sminr 2� �Ave—,ADDRESS/LOCATION: �60- —r"&s v
LOT BLOCK SUBDIVISION
BUSINESS/OWNER NAME: kyua �A.b .
CONTRACTOR/HOMEOWNER
SEC/PH
PHONE: `7 �-! -�3/ 86T4
PHONE:O-Iel 5-74 302CP
CONTRACTOR ADDRESS: 0 ( 1t-1 5VkLJ ( I` I —n�iU�S
ELECTRICIAN:
HVAC:
PLUMBER:
_ GOOD CENTS (Residential only):
CLASS OF WORK
KO
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK: r-6mo\16 t .06h no commQe-ift.a-C _rlawn s4tA�
PROPOSED USE:
HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
o VALUATION: $ I Z I oo0 -
TOTAL AREA: HEATED AREA: �51-r4
p (Cost of Labor and Materials)
PUBLIC SEWER
NUMBER OF BEDROOMS:
❑ SEPTIC/TREATMENT SYSTEM
NUMBER OF BATHROOMS:
SEWER TAP:
INTERIOR WALL TYPE:
SIZE
❑ WATER TAP:
EXTERIOR WALL TYPE:
SIZE
❑ OTHER TAP:
FOUNDATION TYPE:
SIZE
❑ TEMP POLE
ROOF TYPE:
GARAGE TYPE: SINGLE F]
DOUBLE F__] TRIPLE
ATTACHED F__1
DETACHED F—] CARPORT
SIGNATURE OF APPLICANT:
*If proposed work involves new commercial construction o facade improvements/renovations to an existing
commercial property, building elevations are required.
Offic/Aiall Use Only
Plans Examiner Zoning Official Fire Marshall
CpmTents:
VS
r NO
FAX TRANSMITTAL
KLUNKERT & ASSOCIATES, INC. Phone - 979-731-8584
1722 Broadmoor, Suite 102 Fax - 979-731-8579
Bryan, Texas 77802
ATTENTION: kl aoc
Fax Number: —77) 8 -Z�`c3 bi
Dale. � 0-2
SUBJECT:
FROM. M (aW q*
No. PagCS ram_
CON - 'Phia mm-age is intemk-d fM the ustl of the individtol "• rtduy auted ub-C, and n►ay otmtain informrlion thin 1b,
privilegcd, Confidential, and cxcmpl ftvm divclpsUIv under applicahic law. Slwuld you rmcrvC this facsimile transmission in nrrty,
pleww immediately notify ur ity teiq,iwnc (colicct It ticctssary) and n:lurn II,C original mtwsagc to Its by us Postai service. Thank
You.
t,Z/T'd 6020 RLL F1F:01 FJCRT.t'J fJA—CPIHT—C'r-eZ�1'tlN=]'nln'lv!tuo.aa acat,T JtlU7—CT—?IJH
oft
iW
V' ROTEST.,
nen, Quah1y rs the Priorio?
March 26, 2007
First National Bank of Bryan
C/o Mr. Matt Klunkert
Klunken and Associates, Inc.
1722 Broadmoor, Suite 102
Bryan, Texas 77802
RE: Limited Asbestos Inspection
Pawn Shop Building
2305 South Texas Avenue
College Station, Texas 77840
Envirotest Project Number. 1I0U 07 02141
Bear Mr. Klunkert:
Enclosed is the report for the Limited Asbestos Inspection performed at the Pawn Shop
Building located on 2305 South Texas Avcnuc in College Station Texas. The sampling
watt performed on March 20, 2007 by Mr. Michael Gaines of F.nvirotesi, Ltd. Mr. Gaines
is licensed by the Department of State Health Services as an Asbestos Inspector (#60-
2789).
WOPE OF WORK
The scope of this project was lirnited to suspect asbestos -containing materials associated
with the Pawn Shop Building on the above -referenced property. Twenty-four (24)
samples were collected during the inspection. Samples of the following material were
found to contain greater than one percent (1 Yo) asbestos:
1) Floor Tile Mastic
Suspect Materials Tested
During the inspection, sampled materials were assigned a sample number and a
homogenous Breit number. Samples were collected of each area and the friability and
condition of the suspect material was assessed.
Table I contains the homogenous area numbers, material types, material descriptions,
analytical results, and ha72rd assessments.
HOUSTON a CORPUS CM USTI( - PORT ARTHUIR
CtRtPnRATP OFTIC-Et 3902 Rra,daa Orin • I fouetott_ Tx 77W7 - WiM 711-M-4411 • Tpfl Ftrc 14W464-1736 • Fax 713-7&2.3428 . wwwxtkNJA,laxlltd com
IIOU 07 021 e
t71r2'd 6RPO Rl1 A)F;:O1 G1CRTCJ GJG , , — — ♦, —
ENV[ ST..
Wbon QualftV is the Priority
1J:COMMENDATTONS
Recommendations concerning the Asbestos -Containing Material (ACM) identified in this
limiter inspection are based on the following:
1. Condition
2. Friability
3. Potential for disturbance
Condition and Friability
The asbestos -containing floor tile mastic wws in good condition and considered non -
friable.
Res once Actions for Renovation
According to NESHAP.S 40 CFR 61 Subpart M, 61-145 and DSHS Texas Asbestos Health
Protection Rules. 295.60, friable or potentially friable ACM which will be disturbed, or
has the potential to be disturbed during renovation, must be removed. A licensed
asbestos eonsuhuni. should be consulted prior to any renovation operations in a building
or other structure containing ACM. In DSHS' regulated structures, a licensed asbestos
abatement contractor must be used. The project must be designed by a DSHS licensed
asbestos consultant and monitored by a DSHS licensed company.
Response Action for Demolition:
According to NESIMPS 40 CFR 61 Subpart M, 61.14,5 all asbestos containing material
must be removed from a building prior to demolition. Exceptions to this rule can be found
in 40 CFR 61.145(c)(1) and in some circumstances, includes (:alegory I and Category II
materials.
Envirotest recommends that all of the asbestos containing materials be removed prior to
demolition.
HOUSTON . CORPUS C'HRISTI . PORT ARTHUR
CORPORATE m E OFFI('N: !'1U2 Itnxron Drive Fkwanre, Tx 711163
1101 • Voicc 71379i-1411 • T4111=rse 1-RM1- Wi 736 • Fm 713-783-342N . www mwu vit-;1 it tlnen
n0107 07 O2
.I-
t7T /Z * d ARS'GI R1 1 F.1 r.: 0 1 G 1 COT(- ) c I c _cam
Aft
iv
ENVIROTEST..
1C�hett Qualiijl fs the Prtoriip
Use of L eensmi Contractors
According to the DRIS Texas Asbestos health Protection Rules, 29.3.34, the removal of
asbestos in projects covered by the regulations require asbestos abatement spec cations
to be written by a DSI.18 licensed asbestos consultant and air monitoring be performed by
a MRS licensed air monitoring firm. Additionally, a DSHS licensed asbestos abatement
contractor must pertiirm the removal.
Analytical Methods
All analyses were performed at our Houston laboratory using standard oil immersion and
optical staining techniques. Envirotest, Ltd. is an American industrial IIygiene
Association (ATHA) accredited laboratory (ID #10643), a National institute cif Standards
and Technology NVLAP-accredited laboratory (tt101595), and licensed by the
Department of State Health Services (430-0005) for asbestos laboratory analysis.
Limitations—
'Phis sampling report does not guarantee that additional ACM is not present. The scope:
of this project was limited to the materials sampled within this report. Areas such as, but
not limited to, inside walls, inside dwrs, beneath existing floors, We areas, inaccessible
areas concealed by finishing materials, and all other portions of the buildings not
designated in the Scope of Work were specifically excluded.
'ne following analytical results pertain to only the sample analyzed and may not reflect
the actual composition of the entire homogeneous area. Envirotest, Ltd. assumes no
responsibility for any subsequent use or interpretations of these analytical results. This
report must not be used to claim product endorsement by NVLAP or any other state or
federal government agency.
HOUSTON • CORPUS CHRISTY . PORT A1tMUR _
CORPORATE 3'102 llraxlam Urivr • Himwim.'fx 77 MI • Voice 713782-4411 • T01I FF= 1-t K"6047:6 • Fax 713-7 34
HOU 07 -3428 ..www.aivnulrvihd amp
0 le
-3-
t7ZA7,c1 QRC'M R1J C.1G 7O1 cimTrj cic '--- -- '-...
ENVIROT� EST.,
Whim Quality is the Pnorih,
Tf you havc any questions regarding, the inspection report, please call. We appreciate the
opportunity to be of service to you.
Sincerely,
Michael Gaines
Asbestos Inspector (#60-2789)
Envirotest, Ltd.
Jason A. Hinford
Vice President of Environmental Serviecs
Asbestos Consultant (#10-5557)
Envirotest, Ltd.
By, ETI Alanagenleru, L/_C,
HOUSTON • CORPUS MUM + PORT ARTWJR
COR1IOU Y 0210 UFFICE: 39� Uraxtue Drive • Ha�157a1, Tx 77fIG3 . Vm a 711792-111 • Toll Ffw 1400460.t .16 . fax 71i.7112 :la2N • www.envirntest11docev
11[IL147 fl21fl
.4.
V`/q"d F.Crul R)) GJ r—:OI LICQTCI L1L I 1 -- -- r-T - —
w
When
i ANt of Definitions
Asbestos -Containing Material (ACMZ - any material containing more than one percent
asbestos (chrysotile, amositc, erocidolite, tremolite asbestos, anthophyllite asbestos,
actinolite asbestos).
Demolition - the wrecking or taking; out of any load -supporting structure member and any
related razing, removing, or stripping of asbestos products.
Disturbance - wntact which releases fibers from ACM or debris containing ACM
including activities which that disrupts the matrix of ACM, render ACM friable, or
generate visible debris.
Encapsulation - a method of control of asbestos fibers in which the surface of ACM is
penetrated by or covered with a liquid coating prepared for that purpose.
Enclosure - the construction of an airtight, impermeable, semi -permanent barrier
surrounding asbestos to prevent the release of asbestos fibers into the air.
Fiber - a particulate form of asbestos, 5 micrometers or longer, with a length -to diameter
ratio of at least 3 to 1.
Friable Materials - any material that when dry can be crumbled, pulverized, or reduced to
powder by hand pressure.
Homogeneous Area, - an area of surfacing material or thermal system that is uniform in
color and. texture.
Intact - means that the ACM has not crumbled, been pulverized, or otherwise deteriorated
till that it is no longer likely to be bound with its matrix.
Removal - all operations where ACM is taken out or stripped from structures or
substrates, and includes demolition operations.
Renovation - the modifying of any existing structure, or portion thereof.
Reyair - overhauling, rebuilding, reconstructing, or reconditioning of structures or
substrates, including encapsulation or other repair of ACM attached to structures or.
substrates.
HOUSTON • COMIUS CI1RiSTI . FORT AXft tlR
CORPORATF UF7ICL; 3M Bra%#. Drive - Murlim, Tv 7706' HpU 07 0210 •Voice 7177$2 d411 • 'i'o1i frae 1 a4(I4GO 173G • Faz 71 i l8_>-34?8 . zv w.mixu�dn llld,uuu�
-
4- 7 1O' J cr M n' . r I r . n . r . rr.Tr . r r ..-.r,-. .-._ .. .0
oft
When Quality is the Priority
Tables I & II
HOUSTON • CORPUS CUMSTI . PORT ARTHUR
CORPORATE OFFICK; SWI$ Un:tm Drive • Holnton, T% 710fil • Yoke 7117E2A411 • Td1 free I.YlNk4(A.t7;iV . F;m 7(3.78Z-73ZS • �—
HOI 107 UZ in
.6.
t71 C4 AR9,P1 R) ) r_)r-:01 L)COTC) L)L ie -• T Ju
E N VI FOTESus.
ti *11 Quano is the Prion6
TABLE 1- SAMPLE AI.ATERIAL SU_l+W WARY
MATERIAL
MATERIAL
ASBESTOS-
*H.A.
NAME
i DESCRIPTION
MATERIAL LOCATION
CONDITION
FRIABLE
CONTAIINING
MATERIAL
1
Cove Base
Gray/Yellow Mastic
Base Of Walls Throughout
Good
No
No
hbstic
2
Floor Tile
12"x12" Tan Tile / Black
Flooring Throughout
Good
No
Yes
And Mastic
Mastic % Tan Mastic
(Black Mastic
3
Ceiling Tile
2'x 2' White Tile With
Ceiling in Showroom Area
Good
Yes
No
Little Holes And Craters
4
Insulation
White Sheeting of Foam
Throughout Building
Good
No
No
Foam
Insulation
5
Texture
White Texture Wall
On All Painted Walls
Good
Yes
No
Coating
Throughout
6
Drywall
White Chalky Board
Walls Throughout
Good
Yes
Na
Material
7
Joint
White Joint Mud Located
'%"ells Throughout
Good
Yes
No
Com ound
of Sheetrock
8
Insulation
Brown Fibrous Insulation
Above Ceiling Throughout
Good
Yes
No
* = Homogeneous Area
HOUSTON • CORPUS CHRISTI e PORT ARTHUR
CORPORATE OFFICE. 390Z Braxton Drive • Hzusrcn, Tx 77063 • Wice 713732.441 ! • Toll Free I.800-4h0-1736 • Fs,, ?13-?8? •3428 • aw., :utiuuss{3rd cm�
Ifou 07 0210
.7.
oft
iv
ENVIR4TEST..
When Quality is the hlorisy
TABLE U.- SAMPLE NUMBER C* HOMOGENEOUS AREA
SAMPLE 4
*I1A.
SAMPLE LOCH TiON
HOU 07 0210- t
1
No Comer of. Showroom
HOU 07 0210-2
1
Southwest Corner of Showroom
HOU 07 0210-3
1
Diddle of West Wall of Showroom
HOU 07 0210-4
2
Northwest Comer of Showroom
HOU 07 0210-5
2
Southwest Comer of Showroom
I10U 07 0210-6
2
Middle of West Wall of Showroom
HOU 07 0210-7
3
Northeast Side of Showroom
HOU 07 0210-8
3
Middle of Showroom
HOU 07 0210-9
HOU 07 0210-10
3
4
Northwest Side of Showroom
Southwest Ceiling in Showroom
HOU 07 0210-11
4
Northwest Ceiling in Showroom
HOU 07 0210-12
4
Middle of Ceilina in Showroom
1401J 07 0210-13
5
East Wall of Hal l-way Outside Restroom
HOU 07 0210-14
5
West Wall of Hallway outside Restroom
HOU 07 0210-15
5
South Wall of Hallway Outside Restroom
IIOU 07 0210-16
6
South Wall in Storage Room
IIOU 07 0210-17
6
Earl Wall in Storage Room
HOU 07 0210-18
6
North Wall in Storage Room
HOU 07 0210-19
7
North Wall in Storage Roorn
HOU 07 0210-20
7
South Wall in Storage Room
IIOU 07 0210-21
7
East Wall in Sto a Room
HOU 07 0210-22
8
Center of Ceiling in Storage Room
HOU 07 0210-23
8
East End of Ceiling in Storage Room
HOU 07 0210-24
*=TT..
8
w_
West End of Ceiling in Storage Room
�-v.aavav�avVi{J /-11V4
HOUSTON tF CORPUS CEERIST1 • PORT ARTFRTR
CORPORA" F. t)FF'CE: 3M BrUten brae ! 1-ugon, Tx 77043 • V,,,, 7137R2.4411 - TO Frec 1-800-460-1716 • Far 711-71M14?x . yy u �RYj>ptcetlld.cym HOIJ 07 1RI0
1/6•G rAS:'GI R) ) r.)ri:o1 GJCQTC1 G1C , . -.- -- rat , .0
Polarized Light Microscopy Laboratory Analytical Results
HOUSTON . CORPUS MUM . PORT AlUMUR
CORPORATE OFFICE: M2 firamon Urivc • F mqw, Ta 77061 • Vace 7137E3.1411 . I'M hvm 140XP-060-1736 • Fax 713-792 442k . www an�irotceti{d, n
110U 07 0310
.g.
VT/oT ci ARI'GI RJ1 A)r,:01 C.ICRTCI G1Gu--S-T
Envirotest, Ltd. Polarized Light Microscopy Report - Job #107257
Analytical Method: EPA 6001 R-93 / 116 Analyst Name: Porch, Wanda Analysts Initials, AP
Client Name. Enviratesk Ltd.
Client Reference. Klunkert & Associates IncJPawn Shop Building
Envirotest Reference: HOU-07-0210
Client Sample s
(Lab Sample 0)
Layer #: Layer Description
Asbestos
Asbestos Type - %
Non -asbestos Fiber Type - %
Prs.nt
and/or Matrix Material. %
HOU-07-0210-1
(107267-1)
1: Grey Material
No
Cellulose - 02%
2: White Powder
No
Cellulose - 02%
3: Tan Mastic
No
Cellulose - 02%
4. Brown Fibrous Material
No
Cellulose- 05%
HOU-07-0210-2
(107257-2)
1: White Powder
No
Cellulose - 05%
2: White Fibrous Material
No
Cellulose - 20%
3: Ten Mastic
No
Cellulose - 02%
4: Grey Material
No
Cellulose - 02%
HOU-07-0210-3
(107257-3)
1: White Fibrous Material
No
Cellulose - 20%
2: Tan Mastic
No
Cellulose - 02%
3: White Powder
No
Cellulose - 02%
4: Grey Material
No
Cellulose - 02%
HOU-07-0210-4
(107257-4)
1: White Powder
No
Cellulose - 05%
2: Grey/White Floor rile
No
Cellulose - 02%
3: Tan Powder
No
Cellulose - 02%
4: Trace of Black Mastic
No
Cellulose - <1%
HOU-07-0210-5
1: Black Mastic
Yes
Chrysotile - 05%
(107257-5)
2: Yellow Mastic
No
Cellulose - 02%
3, White Floor Tile
No
Cellulose - 02%
HOU-07-0210-6
(107257-6)
1: White Powder
No
Cellulose - OSDA
2: White/Grey Floor Tile
No
Cellulose - 02%
HOU-07-0210-7
(107257-7)
1: White Paint/Grey Fibrous Material
No
Cellulose - 30%
Fiberglass - 15%_
Mineral / Glass Wool - 10%
NVLAPff, 101595 TDH T,icense # 30-000-S
t7T/TT'd FR9,A A)) AJr,:01 c1CCTC-I cis _CnIUTvrruo�.��nv--
Enviratest, Ltd. Polarized Light Microscopy Report - Job #107257
Analytical Method: EPA 900 J R-931116 Analyst Name: Poach, Wanda Analyst's Initials: APO
Client Name: Envirotest, Ltd.
Client Reference: K(unkert & Associates IncJPawn Shop Building
Envirote-st Reference: HOU-07-0210
Ghent Sample !t
Layer N: Layer t)escription
Asbestos
Asbestos Type - %
Non asbestos Fiber Type - %
(Lab Sample #)
Present
■tumor Msirix Material - %
HOU-07-0210-8
1' White Paint/Grey Fibrous Material
No
Cellulose - 20%
(107257-8)
Fiberglass - 10%
Mineral / Glass Wool - 10%
HOU-07.0210-9
1: White Paint/Grey Fibrous Material
No
Cellulose - 20%
(107257-9)
Fiberglass - 15%
Mineral / Glass Wool -10%
HOU-07-0210-10
1: Silver MateriaftNVhlte Glue
No
Cellulose - <1%
(101257-10)
2: White Plastic
No
Cellulose - �1%
Fiberglass - 02%
HOU-07-0210-11
1: Silver Material/White Glue
No
Cellulose - e1%
(107257-11)
2: White Plastic
No
Cellulose - <1%
HOU-07-0210-12
I'Silver Material/WMlhite Glue
No
Cellulose - <t%
(107257-12)
2: White Plastic
No
Cellulose - K1°�b
HOU--07-0210-13
1: Silver MateriaMlWhite Glue
No
Cellulose - <1%
(107257-13)
2: White Plastic
No
Cellulose - <1%
HOU-07-0210-14
1: White Paint/White Powder
No
Cellulose - <1%
(107257-14)
HOU-07-0210-15
1: White Paint/Mite Powder
No
Cellulose - 02%
(107257-15)
14OU-07-0210-18
1: White Paint/Tan Powder
No
Cellulose - 0204
(107257-16)
2, Brown Fibrous Material
No
Cellulose - 20%
3: Drywall Powder
No
Cellulose - 05%
HOU-07-0210-17
1: Brown Fibrous Material
No
Cellulose - 20%
(107257-17)
2: Drywall Powder
No
Cellulose - 05%
NVLAP# 101595 TDH License # 30-0005
V Y fit? 4 "LI r'Ag'171 P) ) r-,) r-! 0 1 C 1 C1OTC 1 L 1 G ) _. rr • it - - - -
Envirotest, Ltd. Polarized Light Microscopy Report - Job #107257
Analytical Method: EPA 6001 R-93 / 116 Analyst Name-, Porch, Wanda Analyst's Initials: An
Client. Name. Envirotwit, Ltd.
Client Reference: Kfunkert & Assoclatits InCJPawn Shop Building
Envirotest Reference; HOU-07-0210
Cliwrt Sample #
(t sb Sample #)
L.ay+er M Leyer Oescriiption
Asbestos
Asbeat� Type - %
Non,ssb9M" Fiber Type
Present
andlor Matrix Material - %
HOU-07-0210-18
1: White Powder
No
(107257-18)
Cellulose - 05%
Z: Brown Fibrous Material
No
Cellulose - 30.E
3: Drywall Powder
No
Cellulose - 02%
HOU-07-0210-19
(107257-19)
1: White PaintNVhite Powder
No
Cellulose - 02%
2: Brown Fibrous Material
No
Cellulose - 10%
3: Drywall Powder
Na
Cellulose - 05%
HOU-07-0210-20
(107257-20)
1: White Paint/White Powder
No
Cellulose - 02%
HOU-07-0210-21 1: White Paint/White Powder No
(107257-21)
Cellulose - 02%
2: Drywall Powder No
Cellulose - 05%
3: Brown Fibrous Material No
Cellulose - 15%
HOU-07-0210-22 1: Brown Fibrous Material No
(107257-22)
Fiberglass - 800A
Cellulose - 02%
14OU-07-0210-23 1: Brawn Fibrous Material No
(107257-23)
Fiberglass - 80%
Cellulose - 02%
HOU-07-0210-24 1: Brown Fibrous Material No
(107257-24)
Fiberglass - 80%
Asbestos content percentages are reported by area percent estimation_ < = less than, =
greater than. Conversion of
area percent to dry weight is not feasible unless the specific gravities and relative volumes
materials known_
of the different matrix
are Accuracy and precision of the analysis is dependent upon the following
analyzed, homogeneity of the sample, nature of matrix interference,
items: quantity of sample
sample preparation techniques,
type, and the percent of asbestos involved.
fiber size, material
Inhomogeneous samples are separated into sub -samples and each layer is analyzed and reported separately,
applicable.
where
Job notes / analytical problems / method departures: none
Reviewed ay:—{_
NVLAP# 101595 TDH License # 30-0005
VT/ET "a AAA P)) r-i r—,01 CIr`o TP/ C IC i -III-r-,rr-r-�,--„- -- -. ...
IT
-4
a
N
W E
S
Envirotest Ltd
Pawn Shop Building
College Station
x
18x 19x
21
23x 17x
22 x
x 13
14x
16 x x 115
x 7
12x
8x
x
5
PAWN SHOP FLOOR PLAN
Legend:
x Sample Location